Tender For Comprehensive Maintenance Of B/R And E/M Works Like Repair, Replacement, Maintenance Of Lt Ug Cables, Mccbs, Lt Outdoor/Indoor Panels, Change Over Switch And Connected Misc Works In Navy Nagar, Otm Accn, installation Sandhani And Ayudh Vih
Tender Overview
Project Description
Tender for Comprehensive Maintenance Of B/R And E/M Works Like Repair, Replacement, Maintenance Of Lt Ug Cables, Mccbs, Lt Outdoor/Indoor Panels, Change Over Switch And Connected Misc Works In Navy Nagar, Otm Accn, installation Sandhani And Ayudh Vihar-Ii At Naval Station Karanja
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE KARANJA NAME OF WORK: Comprehensive maint of B/R and E/M works like repair, replacement, maint of LT UG Cables, MCCBs, LT outdoor/indoor Panels, change over switch and connected misc works in Navy Nagar, OTM accn, INS Sandhani and Ayudh Vihar-II at Naval Station Karanja CONTRACT AGREEMENT No: CWE KJ(K)- OF 2026-2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | Supply and fix in repair manual on load change over switch 415V, 50Hz, 4 Pole of capacity 63 Amp. Make: L&T/C&S/Schneider/Havells |
| 3 | Supply and fix in repair manual on load change over switch in sheet steel enclosure 415V, 50Hz, 4 Pole of capacity 63 Amp. Make: L&T/C&S/Schneider/Havells |
| 4 | Supply and fix in repair manual on load change over switch 415V, 50Hz, 4 Pole of capacity 100 Amp. Make: L&T/C&S/Schneider/Havells |
| 5 | Supply and fix in repair manual on load change over switch in sheet steel enclosure 415V, 50Hz, 4 Pole of capacity 100 Amp. Make: L&T/C&S/Schneider/Havells |
| 6 | Supply and fix in repair manual on load change over switch 415V, 50Hz, 4 Pole of capacity 125 Amp. Make: L&T/C&S/Schneider/Havells |
| 7 | Supply and fix in repair manual on load change over switch in sheet steel enclosure 415V, 50Hz, 4 Pole of capacity 125 Amp. Make: L&T/C&S/Schneider/Havells |
| 8 | Supply and fix in repair manual on load change over switch 415V, 50Hz, 4 Pole of capacity 160 Amp. Make: L&T/C&S/Schneider/Havells |
| 9 | Supply and fix in repair manual on load change over switch in sheet steel enclosure 415V, 50Hz, 4 Pole of capacity 160 Amp. Make: L&T/C&S/Schneider/Havells |
| 10 | Supply and fix in repair manual on load change over switch 415V, 50Hz, 4 Pole of capacity 200 Amp. Make: L&T/C&S/Schneider/Havells |
| 11 | Supply and fix in repair manual on load change over switch in sheet steel enclosure 415V, 50Hz, 4 Pole of capacity 200 Amp. Make: L&T/C&S/Schneider/Havells |
| 12 | Supply and fix in repair manual on load change over switch 415V, 50Hz, 4 Pole of capacity 250 Amp. Make: L&T/C&S/Schneider/Havells |
| 13 | Supply and fix in repair manual on load change over switch in sheet steel enclosure 415V, 50Hz, 4 Pole of capacity 250 Amp. Make: L&T/C&S/Schneider/Havells |
| 14 | Supply and fix in repairs ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps. Make: C&S/Schneider/L&T/ Indoasian/GE/Havells |
| 15 | Supply and fix in repairs ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1000 Amps. Make: C&S/Schneider/L&T/ Indoasian/GE/Havells |
| 16 | Supply and fix in repairs ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1250 Amps. Make: C&S/Schneider/L&T/ Indoasian/GE/Havells |
| 17 | Supply and fix in repairs MCCBs of following current carrying capacity. Make: Legrand/C&S/Schneider/L&T/ Indoasian/GE/Havells/HPL |
| 18 | 3 Pole MCCB 400 Amps, Adjustable type,415V, with breaking capacity 36KA rating |
| 19 | 3 Pole MCCB 250 Amps, Adjustable type, 415 V, with breaking capacity 36KA rating |
| 20 | 3 Pole MCCB 200 Amps, Adjustable type, 415 V, with breaking capacity 36KA rating |
| 21 | 3 Pole MCCB 160 Amps, Adjustable type, 415 V, with breaking capacity 36KA rating |
| 22 | 3 Pole MCCB 125 Amps, Adjustable type, 415 V, with breaking capacity 16KA rating |
| 23 | 3 Pole MCCB 100 Amps, Adjustable type, 415 V, with breaking capacity 16KA rating |
| 24 | 4 Pole MCCB 630 Amps, Adjustable type,415V, with breaking capacity 50KA rating |
| 25 | 4 Pole MCCB 500 Amps, Adjustable type,415V, with breaking capacity 36KA rating |
| 26 | 4 Pole MCCB 400 Amps, Adjustable type,415V, with breaking capacity 36KA rating |
| 27 | 4 Pole MCCB 350 Amps, Adjustable type,415V, with breaking capacity 36KA rating |
| 28 | 4 Pole MCCB 250 Amps, Adjustable type,415V, with breaking capacity 36KA rating |
| 29 | 4 Pole MCCB 200 Amps, Adjustable type,415V, with breaking capacity 36KA rating |
| 30 | 4 Pole MCCB 100-160 Amps, Adjustable type,415V, with breaking capacity 36KA rating |
| 31 | 4 Pole MCCB 630 Amps, 415 V, Microprocessor release with breaking capacity 50 KA |
| 32 | 4 Pole MCCB 400 Amps, 415 V, Microprocessor release with breaking capacity 36 KA |
| 33 | 4 Pole MCCB 250 Amps, 415 V, Microprocessor release with breaking capacity 36 KA |
| 34 | 4 Pole MCCB 160 Amps, 415 V, Microprocessor release with breaking capacity 36 KA, 160 A rated |
| 35 | Supply and fix in repairs Isolator 415 Volts of following current carrying capacity. Make: HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells |
| 36 | 4 Pole 63 Amps |
| 37 | 4 Pole 100 Amps |
| 38 | Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in soft/loose soil all as directed. |
| 39 | Returning and filling in of excavated soil including spreading,levelling, watering and well ramming in layers not exceeding 25 cm each. |
| 40 | Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point. |
| 41 | M&L for Sand cushioning/sand covering for underground cable protection complete all as specified. Note: Punned thickness only will be measured and paid. |
| 42 | Supply & laying un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed. |
| 43 | M&L for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection . |
| 44 | M&L for GI pipe light grade 80 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection . |
| 45 | Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable all as directed. |
| 46 | M&L for PCC type C2, 1:3:6 using (40 mm gradded stone aggregate) in foundations complete all as specified &directed. |
| 47 | Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade 3.5/4 core XLPE , armoured, electric power cables (heavy duty) with aluminium conductor of the following size including dismantling old one. |
| 48 | 25 Sqmm 4 core |
| 49 | 35 Sqmm 3.5 core |
| 50 | 50 Sqmm 3.5 core |
| 51 | 70 Sqmm 3.5 core |
| 52 | 95 Sqmm 3.5 core |
| 53 | 120 Sqmm 3.5 core |
| 54 | 150 Sqmm 3.5 core |
| 55 | 185 Sqmm 3.5 core |
| 56 | 240 Sqmm 3.5 core |
| 57 | 300 Sqmm 3.5 core |
| 58 | 400 Sqmm 3.5 core |
| 59 | M&L for detecting LT UG cable faults located in any stretch/ depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave reciever, cable indentification instrument , cable tracer for exact location of under ground cable routes. Note: The rate quoted deemed to be inclusive of transportation of equipment and charges for service engineer . Note : The fault locator will be arranged by Contractor Only |
| 60 | Disconnecting incoming and outgoing connections, taking out and overhauling of manually operated, draw out type air circuit breaker/gaseous circuit breaker of any make 3/4 pole, including cleaning/ oiling/ greasing all mechanical moving parts, replacement of defective accessories, racking in and connecting incoming/ outgoing cables complete all as specified and directed. Note :Accessories required for replacement shall be measured & paid separately under respective item of this schedule. |
| 61 | Supply and fixing following accessories suitable for air circuit breaker/gaseous circuit breaker of any make 3/4 pole of any make and capacity :- |
| 62 | a)Auxiliary contact |
| 63 | b)motor |
| 64 | c)Trip alarm contact |
| 65 | d)Under voltage release |
| 66 | e)Shunt realease |
| 67 | f)Insulation barrier |
| 68 | g)Earth fault release |
| 69 | h)Racking interlock |
| 70 | M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 25 to 50 sq.mm.Make :- M-SEAL / BIRLA 3 M LTD / RAY CHEM |
| 71 | All as per Item No.31 herein before but for cable of size 3.5 core 95 to 120 sq.mm. |
| 72 | All as per Item No. 31 herein before but for cable of size 3.5 core 150 to 185 sq.mm. |
| 73 | All as per Item No. 31 herein before but for cable of size 3.5 core 240 to 300 sq.mm |
| 74 | All as per Item No. 31 herein before but for cable of size 3.5 core 400 sq.mm |
| 75 | M&L for heat shrinkable End Termination Kit (with colour limbs of Red, Yelllow, Blue & Black) for LT UG cable complete for making serviceable for aluminium conductor cable of size 3.5/ 4 core 50 to 95 sq.mm.Make :- M-SEAL / BIRLA 3 M LTD / RAY CHEM |
| 76 | All as per Item No.36 herein before but for cable of size 3.5 core 120 to 185 sq.mm. |
| 77 | All as per Item No.36 herein before but for cable of size 3.5 core 240 to 300 sq.mm. |
| 78 | All as per Item No.36 herein before but for cable of size 3.5 core 400 sq.mm. |
| 79 | Supply and fix in repair LED indicating lamp of 230 volts AC to show R, Y & B phase with RED, YELLOW and BLUE in colour complete all as specified and directed by Engr-in-Charge. |
| 80 | Supply and fix in repair current transformer of CT ratio 100/5A to different capacity LT Panels complete all as specified and directed by Engr-in-Charge. |
| 81 | Supply and fix in repair digital multifunctional meter having LCD displays showing single and three phase current and voltages for different capacity of LT Panels complete all as specified and directed by Engr-in-Charge. |
| 82 | M&L in repair for control wiring to existing LT Panel with 1/2/2.5/4 Sqmm FRLS wires as required at site with necessary cable duct, Volt meter, Ammeter, alluminium Bus bars, selector switch etc as required at site and connectors with suitable wire lugs complete all as specified and directed by Engr-in-Charge. |
| 83 | M&L for maintenance of LT panels by providing necessary hinges, nuts & bolts, welding and painting at site to electric control panel/LT Panel/Feeder Piller box /Bus bar panel any type and any size of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthatic enamel paint of approved shade over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 84 | M&L Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size |
| 85 | S & F aluminium bus bar red,yellow,blue and black colour coded heat shrinkable sleeve of size 25 x 5 mm fixed with suitable ss nut bolts etc in LT Panel complete all as specified and directed |
| 86 | S & F aluminium bus bar red,yellow,blue and black colour coded heat shrinkable sleeve of size 40 x 10 mm fixed with suitable ss nut bolts etc in LT Panel complete all as specified and directed |
| 87 | S & F aluminium bus bar red,yellow,blue and black colour coded heat shrinkable sleeve of size 60 x 10 mm fixed with suitable ss nut bolts etc in LT Panel complete all as specified and directed |
| 88 | Supply and fixing MS nut bolts,SS nut bolts ,clamp ,screw of different size and sample complete all as specified and directed. |
| 89 | M & L for testing of Lightning Conductor & earthing except new earthing 52 to 55 here-in-after of various EM installation in the presence of Engineer-in-Charge & maintaining record of tests for lightning conductor as per IAFW -2215 by removing all connection and the resistance of earthing & lightning protection network should not exceed 5 Ohm in every building/Panel showing the details of defective earthing & lightening protection system. Items to be repaired/renewal during record of sets for lightening conductors as per IAFW 2215 & also test results to be recorded after repair/renewal. Note :- (i) The earthing showing result beyond 10 ohm to be renewed and shall be measured & paid for separately under relevant item of Sch 'A'. (ii) The test result after renewal of earthing and replacement of defective conductor also be recorded in earthing test book as per IAFW-2215 for lightening conductor & cost for the same is deemed to be included in unit rate of above item. (iii) The unit rate quoted shall be deemed to be included for the test results of all existing earthing point, date of testing and renewal etc to be written on wall of each building as per direction from engr-in-charge with out any extra cost. (iv) The testing of new earthing covered under item Nos 52 to 55 are not covered in this item. |
| 90 | M & L in repair Earthing with galavanised steel earth plate elctrode 600mm x 600mmx6mm thick buried directley in ground, (earth pit not less than 2.25m below ground level), with the top edge of the plate not less then 1.5 m below the normal ground level, connected to 4 mm GI wire and riveted to earth plate,GI earth wire will be protected by using 40mm bore GI pipe (light grade) from earth plate to equipment and watering pipe 20mm bore (light grade), chamber and coping shall be made in PCC (1:3:6) type C1 using 20mm graded stone aggregate, RCC pit cover 50mm thick in 1:2:4 type B1 using 20mm graded stone aggregate reinforeced with 8mm dia TMT bar @ 80mmc/c both way with lifting hook made out of 8mm dia TMT bar duly embedded in RCC cover in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No 3 of SSR Part I and as specified including charcoal dust, common salt complete and earth lead connected to earthing test point/main point and testing of earthing complete as directed.(Note:- Main earthing lead from earth plate to test point & upto 7.5mtr to be provided and the cost of the same shall deemed to be included in the quoted rate). |
| 91 | M & L in repair Earthing with galavanised steel earth plate elctrode 600mm x 600mmx6mm thick buried directley in ground, (earth pit not less than 2.25m below ground level), with the top edge of the plate not less then 1.5 m below the normal ground level, connected to 4 mm GI wire and riveted to earth plate,GI earth wire will be protected by using 40mm bore GI pipe (light grade) from earth plate to equipment and watering pipe 20mm bore (light grade), chamber and coping shall be made in PCC (1:3:6) type C1 using 20mm graded stone aggregate, RCC pit cover 50mm thick in 1:2:4 type B1 using 20mm graded stone aggregate reinforeced with 8mm dia TMT bar @ 80mmc/c both way with lifting hook made out of 8mm dia TMT bar duly embedded in RCC cover in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No 3 of SSR Part I and as specified including charcoal dust, common salt complete and earth lead connected to earthing test point/main point and testing of earthing complete as directed.(Note:- Main earthing lead from earth plate to test point & upto 7.5mtr to be provided and the cost of the same shall deemed to be included in the quoted rate). |
| 92 | M & L in repair earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point all as specified and indicated including testing on completion |
| 93 | -Ditto- all as per srl item No. 54 hereinbefore, but with copper earth electrode of size 60 cm x 60 cm x 3.15 mm thick & earth continunity lead of size 20 mm x 3 mm copper strip, complete all as specified and directed 'Note :-for item No. 52 to 55 :- (i) copper/Aluminium strip upto 7.5 m will be deemed to be inluded in quoted rate of item No. 54 to 57 respectively. (ii) The earth chamber shall be constructed 50 cm away from the edge of earth pit & the cost of the same is deemed to be included in rate quoted for above items. |
| 94 | Supply & fix in repairs GI funnel suitable for GI/ Copper earthing complete all as specified and directed. |
| 95 | M&L for Raw salt with mixiing with water and pouring in existing earthing complete all as specified and directed. |
| 96 | M & L for PCC (1:2:4) type B1, using (20 mm graded stone aggretgate) for earth chambers as in repairs, coping for GI pipe post including necessary form work, excavation in soft loose soil, returning in filling and removing surplus soil to a distance n. exc 50 mtr and deposing where directed. |
| 97 | Removing existing worn out CI cover with angle iron frame of earth chamber and supply and fix new CI cover of size 30 cm x 30 cm x 6 mm thick fixed in frame made out of mild steel angle iron 40 mm x 40 mm x 6 mm thick with and including locking and lifting arrnagement, painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed |
| 98 | Supply and lay 20 mm dia, GI pipe, medium grade, burried in trenches as earth continuity protection as in repairs, including necessary excavation and earth work in hard/dense soil, returining & filling in, watering and well ramming, removal of surplus soil to a distance not exc 50 mtrs complete all as specified and directed. |
| 99 | Supply and lay 40mm dia, GI pipe, light grade, burried in trenches as earth continuity protection as in repairs, including necessary excavation and earth work in hard/dense soil, returining & filling in, watering and well ramming, removal of surplus soil to a distance not exc 50 mtrs complete all as specified and directed. |
| 100 | S & F in repair GI or steel wire 4mm on wall/surface for conductors or as earth continuity conductor all as specified and directed. |
| 101 | S & F in repair GI strip of 25x4mm on wall/surface for conductors or as earth continuity conductor all as specified and directed. |
| 102 | S & F in repair GI strip of 32x6mm on wall/surface for conductors or as earth continuity conductor all as specified and directed. |
| 103 | S & F in repair copper strip of 20x3mm on wall/surface for conductors or as earth continuity conductor all as specified and directed. |
| 104 | M&L for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, Outdoor type, of Suitable to accomodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :(A) INCOMING -(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 630 Amps – 01 No.Make : L&T/ABB/SIEMENS(B) OUTGOING-(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 400 Amps – 01 No.Make : L&T/ABB/SIEMENS(ii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 315 Amps – 01 Nos .Make : L&T/ABB/SIEMENS(iii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 200 Amps - 01 Nos .Make : L&T/ABB/SIEMENS(iv) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 125 Amps – 02 Nos .Make : L&T/ABB/SIEMENS(v) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 100 Amps- 01 Nos Make : L&T/ABB/SIEMENS(vi) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No(vii) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. MAKE AE/NSDA/PRINZ(viii) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each, Make TEKNIK/SELECT/L&T(ix) Aluminium bus bar of Rating 800 Amp R-Y-B phases and Neutral.(x) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted.(xi) Foundation for the panel should provided with PCC 1:4:6 at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables. |
| 105 | Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. |
| 106 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 107 | Material and labour for cement concrete type D-2 1:4:8 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete etc as specified and directed. |
| 108 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra including dismentling of old tiles complete all as specified & directed . |
| 109 | Taking down old paver blocks any shape, size and thickness from the existing surface and refixing at the same place after levelling the ground by using sand caushion for maintaing camber and slope all as per directed by Engr-In Charge Note:- Sand Cushion will be paid under Item No 71 |
| 110 | Material and labour for sand cushioning for laying interlocking paver block complete all as specified and directed. |
| 111 | Material and labour for 100mm thick cement concrete type B-2 1:2:4 using 20mm graded crushed stone aggregate as in path/floor finished fair even and smooth without using extra cement, laid in alternate panels of size not exc 4 sqm each including bitumen filling in joints complete all as specified and as directed by Engr-in-Charge. |
| 112 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. |
| 113 | Demolition of stone/brick masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings dressed stone work and pre cast concrete articles complete all as specified and directed. |
| 114 | M&L brickwork with sub class 'B' bricks , straight or curved on plan exc 6m mean raidus built in cement mortar 1:6 complete all as specified and directed |
| 115 | All as per srl item No. 75 here in before but except bricks Note:- Serviceable bricks obatined from srl item No. 08 shall be re-used in srl item No. 76 after cleaning etc complete all as specified and directed by Engr-in-Charge. |
| 116 | M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick/concrete surfaces with two coats i.e (10 mm thick backing coat and 5mm thick finishing coat) , finished even and smooth complete all as specified and directed. (Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.) |
| 117 | M&L for preparation of new or previously untreated plastered surfaces of walls/Ceiling and applying two coats of acrylic antifungal paint exterior grade paint CAMOUFLAGE PATTERN on one coat of primer complete all as specified and as directed. |
| 118 | M&L for PCC (1:2:4) type B0 (using 12.5mm graded aggregate) in coping bed black etc including nessesary form work complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender