Tender For Provn Of Chain Link Fencing, Ug Sump, Sheds, Groom Bath Room And Addn / Altn To Certain Bldgs And Certain Other Works In Eqtn Sec At Ima Dehradun
Tender Overview
Project Description
Tender for Provn Of Chain Link Fencing, Ug Sump, Sheds, Groom Bath Room And Addn / Altn To Certain Bldgs And Certain Other Works In Eqtn Sec At Ima Dehradun
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Oct-2026 | Date Amendment as on 22 Oct 2026 | Date | 10-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE 'A' PART - I (BUILDING WORK) |
| 2 | Construction of Groom bath room (Single story) complete all as specified and shown on drawings. |
| 3 | Construction of Buggy store (Single story) complete all as specified and shown on drawings. |
| 4 | Construction of RCC UG water sump 20000 ltrs capacity complete all as specified and shown on drawings. |
| 5 | SCHEDULE 'A' PART - II (Internal Water Supply) for details refer Sch A in pdf folder |
| 6 | SCHEDULE 'A' PART - III A (Internal Electrification) for details refer Sch A in pdf folder |
| 7 | SCHEDULE 'A' PART - III B (Internal Electrification) |
| 8 | M & L for point wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade, two single core multistran-ded (FRLS-H) copper conductor cable in and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed / surface, sunk cast iron or 1.2 mm thick pressed steel terminal box duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire upto common earth and connected to common earth dolly incl cutting and chases pinning in |
| 9 | for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: - |
| 10 | (a) One light point, bulb, call bell controlled by one, one way 5/6 Amp switch. |
| 11 | (b) One exhaust fan point controlled by one, one way 5/6 Amp switch. |
| 12 | (c) One 3 pin 5/6 Amp socket on independent board |
| 13 | All as per item No 4.01 & 4.02 above, but point wiring with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sq mm for one 3 pin socket outlet 15 Amp independent |
| 14 | S&F LED bulb 10W, 220 volts AC complete all as specified and directed. |
| 15 | S&F GI pipe bracket made out of GI pipe light grade 32 mm dia and bent to shape 1.5 m long including two Nos of MS clamps made out of MS FI 32 x 4 mm size with nuts, bolts & washers complete all as specified and directed. |
| 16 | SCHEDULE 'A' PART - IV (Site Clearance and Earth work) for details refer Sch A in pdf folder |
| 17 | SCHEDULE 'A' PART - V A (Sewage Disposal) for details refer Sch A in pdf folder |
| 18 | SCHEDULE 'A' PART - V B (Sewage Disposal) |
| 19 | M&L for construction of conventional RCC Septic tank 50 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in walls, base slab, baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter complete all as specified and directed and as shown on drawings. |
| 20 | M&L for soakage well of size 1.80 m dia and 3.00 m effective depth, excavation in any type of soil, foundation in PCC 1:3:6, brick walls of honeycomb masonary and solid using sub class B bricks in CM 1:4, including RCC cover slabs in M-25 and filling with brick bats etc, returning filling and removing excavated material, interconnecting pipes of RCC / DWC complete all as specified and directed and as shown on drawings. |
| 21 | M&L for factory made precast heavy duty RCC drain cover 80 mm thickwith using 10mm dia reinforcement TMT bars @150 mm c/c both ways including 1.00mm thick MS black sheet frame on edges with two coats of ante corresive paint over primer complete all as specified and directed. |
| 22 | SCHEDULE 'A' PART - VI (Area Drainage)for details refer Sch A in pdf folder |
| 23 | SCHEDULE 'A' PART - VII A (FENCING)for details refer Sch A in pdf folder |
| 24 | SCHEDULE 'A' PART - VII B (FENCING) |
| 25 | S&F 4 mm dia PVC coated chain link fencing of weight not less than 3.5 Kg/ Sqm made up into matresses or cages, lapped, wired and laid in position including closing after filling complete all as specified and directed.Note :- Mesh size shall be approved by Engr-in Charge as per site requirement. |
| 26 | SCHEDULE 'A' PART - VIII A (External Water Supply) for details refer Sch A in pdf folder |
| 27 | SCHEDULE 'A' PART - VIII B (External Water Supply) |
| 28 | M&L drilling existing CI pipe of any size dia for fixing the GI clamps suitable for GI pipe 50 mm dia using clamps, other fittings/fixtures etc including excavation upto any depth complete all as specified and directed by Engr-in-Charge. |
| 29 | M&l for brick masonry valve chamber of size 450 x 450 x 450 mm (internal dimension) PCC foundations, plastering and necessry excavation and earth work in hard/dense soil, MS sheet cover 3.15 mm thickness alongwith angle iron frame of size 40x40x6 mm with locking arrangment with ncessary fixing materials like hinges, nuts, bolts etc. (Valve chamber cover shall be opened in two havels) and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed. |
| 30 | Supply and installation of high presuure water gun ISI approved made of brass, stainless steel,flamingo styled having dimension 140 x 30 x 25 Centimeters, inlet connection threaded type of size 50 mm, outlet connection flange type of size 2\\" BSP Female threaded Connection, available in both Full Circle & Part circle design, heavy duty brass nut, tube and nozzles, stainless steel Pivot Pin, springs and part circle mechanism, jet breaker screw to change the water jet from heavy droplets to fine spray, recommended Pressure : 2.0 - 5.0 kg/cm 2 or 30 - 70 Psi, recommended spacing not less than 36 m radius for higher distribution uniformity, trajectory Angle: 27 degree, maximum pressure 70 pound per square inch complete with 1 type (C) adapter rubber washer 50 mm, 18 ft ISI GI riser pipe with 3 leg height adjustable stand, 1 type (C) end cap 50 mm, complete with foundation all as specified and directed. Make: Jalkipari rain gun set with Automat HT 44G 2\\" Flamingo Raingun |
| 31 | S&F monoblock pump set suitable for 415 Volts, 3 phase system having capacity 3 HP complete all as specified and directed. |
| 32 | S&F Foot Valve CI conforming to IS 4038, 50 mm (2”) dia complete all as specified and directed. |
| 33 | S&F DOL motor starter 3 phase for 3 HP motor complete all as specified and directed. |
| 34 | SCHEDULE 'A' PART - IX A (EXTERNAL ELECTRIFICATION)for details refer Sch A in pdf folder |
| 35 | SCHEDULE 'A' PART - IX B (EXTERNAL ELECTRIFICATION) |
| 36 | M&L for installation, commissioning and testing factory made CPRI approved out door cubical type panel board over all size not less than 750 x 600 x 750 mm fabricated with 3.15 mm thick CRCA sheet (Heavy duty) over a frame of 60 x 40 x 6 mm angle iron and mounted on platform all around and dust & vermin proof, IP-65 protection, back side openable, fixed with nuts & bolts and front side openable with hinged shutter and locking arrangement by operate alen key individuals for MCCBs and over all front panel double door shutter with powder coated finished both internally and externally suitable for 415 V, AC, 50 HZ, 3 Phase, 4 wire system by means of aluminium bus bar of size 50 x 5 mm (Main) duly wrapped with coloured insulating tape/ sleeves mounted on porcelain insulators including fixing MCCB 40 amp 4 pole and astronomical timer switch necessary inter connections with aluminium strips of size 30 x 5 mm duly wrapped with coloured insulating tape/ sleeves mounted on porcelain insulators and providing following equipments including connection with all in coming/out going cables of size 16 / 25 sqmm duly crimping with suitable size lugs complete. |
| 37 | M&L in position new Pole box made of thermoplastic Polycarbonate having IP65/IP66 degree of protection (shock proof, dust proof, jet water proof and acid resistive). The gasket should be internally embedded, and made of Polyeutherene. The boxes shall be tested as per IEC 60670-2/ 60670-22. The boxes shall have self threaded holes & provision for mounting din rail. The lid should be hinged type with sealing screw. The screw should be of stainless steel so that there is no corrosion. The boxes should withstand temperature of -40c to +120c. The glow wire test should be conducted at 960 c or 750 c and material should be flame retardant & self extinguishing. UL subject 94, V-0. The boxes should be free from toxic substances like hal ogen and silicon. The boxes should have suitable pre-moulded knock out /or plan wall depending on requirement. Box dimension shall not be |
| 38 | less than 155 X 210 X92 MM (LXBXH). Box shall be suitable for 16/25 Sqmm cables including one no. MCB SP 230 volts 6 amps,10 KA, C Curve of make Havells / Legrand / ABB and connecting the bus bars to cables with using suitable GI nut, bolts and washers and aluminum lugs etc fixed on pole using 30x5 mm FI clamps, nuts, bolts & washers complete all as specified and directed. Make: Hensel/GE/Legrand. |
| 39 | S&F LED street light fitting 90 watts made up of pressure die cast aluminium housing with toughened glass and high power LEDs with IP66 IK 07 protection and integrated driver with 5KV inbuilt surge protection suitable for fixing on walls, warm / natural / cool white as per requirement at site. LEDs should be surrounded with aluminium reflector complete all as specified and directed by Engr-In-Charge. Make: Eveready / Bajaj / Philips / Havells / Halonix |
| 40 | S&F 1.5 sqmm three core FRLS-H PVC insulated copper multistranded conductor cable drawing into existing / new PVC rigid conduit in surface / concealed as required complete all as specified and directed. Make: L&T / Havells / Polycab |
| 41 | SCHEDULE 'A' PART - X (LIGHTNING CONDUCTOR)for details refer Sch A in pdf folder |
| 42 | SCHEDULE 'A' PART - XI (DEMOLITION / DISMANTLING)for details refer Sch A in pdf folder |
| 43 | ADDITION / ALTERATION (E/M) |
| 44 | Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed. |
| 45 | M&L modular point re-wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH having multi stranded copper conductor of 1.5 sq mm nominal cross sectional area drawn in and including non rigid PVC Conduit concealed in wall with all fitting not less than 25 mm dia and fixing accessories and 1.5 sq mm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including modular metal flush box of required size factory made for mounting Modular switch, regulators etc with and including Modular cover and frame, ISI marked for the following-Make of wire: Havells / Polycab / Anchor |
| 46 | One light point controlled by one, one way switch 5 Amps |
| 47 | One ceiling fan/exhaust fan point controlled by one, one way switch 5 Amps |
| 48 | All as above for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches complete all as specified and directed. |
| 49 | All as above for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board complete all as specified and directed. |
| 50 | All as above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete. |
| 51 | M&L new modular point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH having multi stranded copper conductor of 1.5 sq mm nominal cross sectional area drawn in and including non rigid PVC Conduit concealed in wall with all fitting not less than 25 mm dia and fixing accessories and 1.5 sq mm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including modular metal flush box of required size factory made for mounting Modular switch, regulators etc with and including Modular cover and frame, ISI marked for the following-Make of wire: Havells / Polycab / Anchor |
| 52 | One light point controlled by one, one way switch 5 Amps |
| 53 | One ceiling fan/exhaust fan point controlled by one, one way switch 5 Amps |
| 54 | All as above for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches complete all as specified and directed. |
| 55 | All as above for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board complete all as specified and directed. |
| 56 | All as above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete. |
| 57 | S&F Modular switch single pole one way 6/10 amp white in colour complete all as specified and directed by Engr-In-Charge.Make: Havells ORO (White) / Legrand Lyncus / Schneider Zencelo |
| 58 | S&F Modular switch single pole one way 16 amp white in colour complete all as specified and directed by Engr-In-Charge.Make: Havells ORO (White) / Legrand Lyncus / Schneider Zencelo |
| 59 | S&F Modular socket outlet 2/3 pin combined 2 module 16 amp white in colour complete all as specified and directed by Engr-In-Charge. Make: Havells ORO (White / Legrand Lyncus / Schneider Zencelo |
| 60 | S&F Modular socket outlet 2/3 pin combined 2 module 6 amp white in colour complete all as specified and directed by Engr-In-Charge. Make: Havells ORO (White) / Legrand Lyncus / Schneider Zencelo |
| 61 | S&F modular fan step regulator 120 W 2 module white in colour complete complete all as specified and directed by Engr-In-Charge. Make: Havells ORO (White) / Legrand Lyncus / Schneider Zencelo |
| 62 | S&F in replacement of LED tubelight batten fitting 20 Watt made of aluminium housing suitable for fixing on walls/ceiling, warm / natural / cool white as per requirement at site complete all as specified and directed by Engr-In-Charge. Make: Eveready / Bajaj / Philips / Havells |
| 63 | S&F new LED tube light batten fitting 20 Watt made of aluminium housing suitable for fixing on walls/ceiling, warm / natural / cool white as per requirement at site complete all as specified and directed by Engr-In-Charge. Make: Eveready / Bajaj / Philips / Havells |
| 64 | S&F in replacement of LED tubelight batten fitting 40 Watt made of aluminium housing suitable for fixing on walls/ceiling, warm/natural/cool white as per requirement at site complete all as specified and directed by Engr-In-Charge. Make: Eveready / Bajaj / Philips / Havells |
| 65 | S&F new LED tubelight batten fitting 10 Watt made of aluminium housing suitable for fixing on walls/ceiling, warm /natural / cool white as per requirement at site complete all as specified and directed by Engr-In-Charge. Make: Eveready / Bajaj / Philips / Havells |
| 66 | S&F new LED 36 Watts, 2'x2' recessed ceiling light fitting,warm /natural/ cool white as per requirement at site with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make: Eveready / Bajaj / Philips / Havells |
| 67 | S&F ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate/ isolated body complete all as directed. Make: Anchor / Crabtree / Ess Ess Kay |
| 68 | S & F in replacement sub main wiring with 2 run of 6 sqmm PVC insulated unsheathed FRLSH cable 1100 Volt grade, with multi stranded copper conductor drawing in existing concealed conduit including one run of 6 sqmm PVC insulated unsheathed cable with multi stranded copper conductor as a earth continuity and connected upto DB complete all as specified and directed.Note: Two run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. Make of wire: Havells / Polycab / Anchor |
| 69 | S & F new sub main wiring with 2 run of 4 sqmm PVC insulated unsheathed FRLSH cable 1100 Volt grade, with multi stranded copper conductor drawing in existing concealed conduit including one run of 4 sqmm PVC insulated unsheathed cable with multistranded copper conductor as a earth continuity and connected upto DB complete all as specified and directed.Note: Two run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. Make of wire: Havells / Polycab / Anchor |
| 70 | S&F in replacement MCB DB complying with IEC 61439 -1&3, sheet metal enclosures double door with provision for 01 x 32 amp SPN MCB as incoming and MCB SP 6 to 32 amp as outgoing as per way of DB. The DBs should be supplied with tin platted insulated copper bus bar rated for 200 amp, 240 volts 2 in 1 shutter (Metal Door) with IK-09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site. The DB door shall have overhang, to gel with wall properly. The DB shall be supplied with all insulated N. Bar riveted on Din channel frame |
| 71 | and should not restrict cable entry from top or bottom. The DB shall have plastic knobs on shield to hold complete all as directed of following capacity:-Make: Havells / HPL / Indo asian |
| 72 | 4 way SPN DB |
| 73 | 8 way SPN DB |
| 74 | 12 way SPN DB |
| 75 | S&F new MCB DB complying with IEC 61439 -1 & 3, sheet metal enclosures double door with provision for 01 x 32 amp SPN MCB as incoming and MCB SP 6 to 32 amp as outgoing of 8 way SPN DB. The DBs should be supplied with tin platted insulated copper bus bar rated for 200 amp, 240 volts 2 in 1 shutter (Metal Door) with IK-09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site. The DB door shall have overhang, to gel with wall properly. The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom. The DB shall have plastic knobs on shield to hold complete all as directed.Make: Havells / HPL / Indo asian |
| 76 | S & F in replacement VTPN Distribution boards 4 way of module (4 + 12) epoxy powder coated fabricated from minimum 1.6 mm thick CRCA sheet and fixed/ flush to wall and suitable for universal mounting with fully insulated 250 Amps copper bus bar for each phase and 02 neutral shrouded bar, 2 earth bar and cable tie for cable management with reversible door for IP-43, IK -09, 415 volt with provision of rating upto 125 Amp MCCB FP as incomer and SP MCBs or TP MCBs as per site requirement (or any combination of SP/TP MCBs) outgoing. Make: Havells / Legrand / Schneider / Indo asian |
| 77 | S&F in replacement MCB SPN 'B' curve 6 to 32 Amp complete all as specified and directed by Engr-In-Charge. Make: Havells / Indo asian / HPL |
| 78 | S&F new MCB SPN 'B' curve 6 to 32 Amp complete all as specified and directed by Engr-In-Charge. Make: Havells / Indo asian / HPL |
| 79 | S&F in replacement MCB SP 'B' curve 6 to 32 Amp complete all as specified and directed by Engr-In-Charge. Make: Havells / Indo asian / HPL |
| 80 | S&F new MCB SP 'B' curve 6 to 32 Amp complete all as specified and directed by Engr-In-Charge. Make: Havells / Indo asian / HPL |
| 81 | S & F in replacement MCCB 100 Amp 4 pole lcs=50% Icu at 415 volts of breaking capacity 16 KA fixed type with thermal magnetic release and overload setting with enclosure complete all as specified and directed. Make:- Havells / Indo asian / HPL |
| 82 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, 5 star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 83 | S&F in replacement LED flood light fitting 50 Watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs with IP66 IK 07 protection and integrated driver with 5KV inbuilt surge protection suitable for fixing on walls, warm/natural/cool white as per requirement at site.LEDs should be surrounded with aluminium reflector complete all as specified and directed by Engr-In-Charge. Make: Eveready / Bajaj / Philips / Havells |
| 84 | S&F new LED flood light fitting 50 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs with IP-66, IK 07 protection and integrated driver with 5 KV inbuilt surge protection suitable for fixing on walls, warm/natural/cool white as per requirement at site. LEDs should be surrounded with aluminium reflector complete all as specified and directed by Engr-In-Charge. Make: Eveready / Bajaj / Philips / Havells |
| 85 | S&F in replacement batten holder, insulated polycabonate body with back plate white in colour suitable for batten fittings including one number inverter LED lamp 15 watt complete all as specified and directed by Engr-In-Charge. Make of holder: Cona / Orient / Anchor Make of Bulb: Havells / Crompton / Philips / Bajaj |
| 86 | Supply and fix new exhaust fan 250 mm sweep, 1200 RPM, made up of Sturdy Engineering Plastic complete, voltage 230 Volts, 50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, box type louvers etc including taking down old unsv exhaust fan complete all as specified and directed. Make: Havells / Crompton / Usha |
| 87 | S&F plug and socket metal enclosure box of module (2P+E- SP), IK 08, supplied with Neutral links complete with one MCB SP 20 amp, 240 Volts recess mounted with chained metal cover for the socket outlet complete all as specified and directed by Engr-In-Charge. Make: Legrand / Siemens / L&T |
| 88 | Supply and fix electric water heater 25 ltr, 5 star rated, 2000 wattage power, pressure 8 bar, storage type made of rust proof metallic body powder coated, storage tank made of durable Nano Poly Bond Technology that ensures excellent Corrosion Resistance and Excellent Oxidation Resistance, ISI marked nickel coated special element to provide resistance against scale formation, specially designed sacrificial magnesium anode rod which has stainless steel core that is designed to protect the inner tank from corrosive elements,Temperature Control Knob, advanced 3-level safety Capillary Thermostat, automatic thermal cut-out & multi-functional valve to provide higher safety that keeps all parameters in check for protection against electric shocks and auto-off function in case of malfunction alongwith special features like auto restart and fast heating white in colour complete with all accessories all as specified and directed by Engr-In- Charge. Make: Jaquar / Crompton / Havells |
| 89 | M&L in replacement of earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish,internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh,80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No. 5 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20 mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. |
| 90 | M&L new earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish,internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM jalli and charcoal dust and common salt all as shown in electrical plate No. 5 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20 mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. |
| 91 | ADDITION / ALTERATION (B/R) |
| 92 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified. |
| 93 | M & L Brick work using sub class “B” bricks straight or curved on plan exc 6 metre mean radius built in CM 1:6 (Old size brick) complete all as specified and directed. |
| 94 | M & L for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in coping, benching, hold fast etc including weathering sliglitely rounded or chamfered including necessary use and waste of form work complete all as specified and directed. |
| 95 | Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and directed. |
| 96 | M&L for rendering 15 mm thick in cement mortar 1:6 on fair face of brick work of walls, finished even & smooth without using extra cement, complete all as specified and directed. |
| 97 | M & L rendering 15mm thick on cement mortar 1:4 mixed with water proofing compound finished fair faces of brick/concrete surfaces even and smooth. Note:-WPC will be measured and paid separately. |
| 98 | Supply only integral water proofing compound, ISI Marked. |
| 99 | M&L for preparation of newly plastered surfaces of wall and applying three coat of white wash on walls complete all as specified and directed. |
| 100 | M&L for preparation of newly plastered surfaces of wall applying two coats of oil bond distemper over a coat of primer over a coat of wall care putty (2 mm thick) to make surface even and smooth, and complete all as specified and directed. |
| 101 | Complete removal of existing treatment from wall applying two coats of oil bond distemper over a coat of primer over a coat of wall care putty (2 mm thick) to make surface even and smooth, and complete all as specified and directed. |
| 102 | Complete removing of existing treatment from walls by using sanding machine complete all as specified and directed. (work to be carried upto a height of 7.50m height) |
| 103 | M&L for preparation of scrapped / new surface of wall and applying 1 to ½ mm thick Asian acrylic damp proof wall care putty as per manufactur instruction complete all as specified and directed. |
| 104 | M&L for applying two coats of weather proof exterior emulsion paint (Apex of Asian, weather coat of Berger) of ant tint over a priming coat on wall, chajjas, facia etc with mechanical spray machine complete all as directed. Note : The work will be carried out upto double storey building.The rate of scaffolding, spray machine and other T&P is included) |
| 105 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed. |
| 106 | M&L for preparation of old painted wooden surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint with approved shade complete all as specified and directed. |
| 107 | M&L for preparation of old painted steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint with approved shade complete all as specified and directed. |
| 108 | Dismantling framed timber scantlings 40 sq. cm and over in section, in any position |
| 109 | S&F MS Rolled sections conforming to Fe 410 -W (GdeE- 250) quality A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates |
| 110 | S&F MS Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw including bending and welding angles, as necessary, gusset plates, riveting etc. n exc 10 kg each brackets, conforming to Fe-290 Gde-E-165 |
| 111 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the othe other , or screwed both ends, each screwed ends to be fitted with washers and one hexagonal or square nut exc 15 cm but n.exc 22.5 cm long and dia of neck 11 to 15 mm complete. |
| 112 | S & F Pre- painted galvalume aluminium Zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges fixed with self tapping screws etc complete all as directed. |
| 113 | S & F Pre- painted galvalume aluminium Zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as directed. |
| 114 | S & F Pre- painted galvalume aluminium Zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges fixed with self tapping screws etc complete all as directed including dismantling existing AC/GI/PVC sheets. |
| 115 | S & F Pre- painted galvalume aluminium Zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as directed including dismantling existing AC/GI/PVC sheets. |
| 116 | S&F 4mm thick E-board false ceiling (Classic) including galvanised colour coated snap grid frame for false ceiling, size of grid 605 X 605mm fixed with 1.6 mm dia GI wire suspenders one end tied to roof members and other end connected to main tee of grid framework by means of 4mm dia adjustable \\"J\\" hook consisting of two Nos washers and two nuts at 1.2 mtr centres, size of main tee 38mm X 25mmX 1.4mm, cross tee 38 mm X 25 mm X 1.4mm, angle along walls 38 mm X 25mm X 2.0 mm complete all as directed. |
| 117 | M & L Rolled structural mild steel work Fe 410-W (Gde-E-250) quality B, rectangular tubing/angle as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed. |
| 118 | S&F 40 mm thick first class hard wood (teak wood) in flooring skirting planed on side with butt joints and fixed with nails with and including 2 coats of cresoting on back side of wooden surface and two or more coat of french polishing on exposed surface complete all as specified & directed including dismantling existing wooden flooring complete all as specified and directed. |
| 119 | S & F 15mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete including taking up or down existing steel tubing pipe complete all as directed. |
| 120 | S & F 20mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete including taking up or down existing steel tubing pipe complete all as directed. |
| 121 | S & F 15mm bore gun metal globe/gate valves, with iron wheel head, screwed both ends for iron/GI pipe fixed in repair complete all as directed. |
| 122 | S & F 20mm bore gun metal globe/gate valves, with iron wheel head, screwed both ends for iron/GI pipe fixed in repair complete all as directed. |
| 123 | S&F long body 15mm bore bib tap, fancy type, chromium plated, cast copper alloy, with capstan head, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified & directed. |
| 124 | S&F CP angle valve, fancy type long body for 15 mm bore pipe with capstan head long screwed shank including cp cover plate complete all as specified & directed. |
| 125 | Supply only metallic hardener in top layer of PCC floor as per manufacturer instructions complete all as specified & directed. |
| 126 | M&L for 100 mm thick Cement concrete type B-2 1:2:4 (40mm graded aggregate) as in flooring and Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified & directed. |
| 127 | S&F Mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing and similar work conforming to Fe.290 Gde-E-165 complete all as specified and directed |
| 128 | S&F MS Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. conforming to Fe 410 -W (GdeE- 250) quality A complete all as specified and as directed. |
| 129 | S&F Welded steel wire fabric weight not exc 4 Kg/Sqm complete and fixed to wood or steel members complete all as specified & directed. |
| 130 | S&F MS Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified & directed. |
| 131 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed |
| 132 | M&L RCC 1:2:4 type B1 (using 20 mm graded aggrigate) as in slab, chajjas, beam etc and similar suspended works complete all as specified and directed. |
| 133 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth for foundation etc and getting out in soft/loose soil complete all as specified and as directed. |
| 134 | Returning filling including spreading, levelling, watering and well ramming in layers n exc. 25cm (soft / loose soil). |
| 135 | Removing excavated material (soils) not exc 50 m and depositing, where directed at a level n. exc 1.5 m above the starting point complete all as specified and as directed. |
| 136 | Removing excavated material (soils) exc 250 m and not exc 500 m and depositing, where directed at a level n. exc 1.5 m above the starting point complete all as specified and as directed. |
| 137 | M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed. |
| 138 | M&L RCC Design Mix M-25 (using 20 mm graded aggregates) as in columns, pillars, piers etc complete all as specified and as directed. |
| 139 | M&L RCC Design Mix M-25 (using 20 mm graded aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 140 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, plinth beams or similar works vertical or to batter for rough finished surface of concrete |
| 141 | Use and waste of formwork to sides of pillars, posts, struts, columns for rough finished surface of concrete. |
| 142 | Form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exc 200mm thick, flat rough finished surface of concrete complete, all as specified and directed. |
| 143 | M&L for TMT bars 10mm dia and over cut to length, bent to shape required including cranking and binding with Mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 144 | M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking and binding with Mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 145 | Material & Labour for providing and fixing stainless steel (Grade 304) structure made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. |
| 146 | Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as directed. |
| 147 | M&L for 20 mm thick Screed bed or bedding layer in cement mortar 1:4, for laying floor finishes complete all as specified. |
| 148 | Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubish off the premises complete all as specified and directed. |
| 149 | M & L Glazed ceramic coloured tiles of size 450x300/600x300x7 to 8 mm, as in vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick rendering in CM (1:6) finished rough surface to receive tiles complete all as directed. |
| 150 | M & L Non skid ceramic coloured tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in CM 1:6 complete all as directed. |
| 151 | M & L PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregate as in surface channels and drains complete all as specified and directed. |
| 152 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. |
| 153 | Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto |
| 154 | Taking down chowkhats or frame with shutters (without taking off shutters from the frames) area n exc 1.5 Sqm each complete all as specified and directed |
| 155 | Taking down chowkhats or frame with shutters (without taking off shutters from the frames) area .exc 1.50 Sqm and n exc 4.00 sqm each complete all as specified and directed |
| 156 | S&F Steel window factory made with side hung shutter including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded complete all as specified and directed as per drg No TD 088 Sheet 1/17 to 17/17. |
| 157 | S&F Steel window factory made with side hung shutter including box type hinges with steel handle and steel peg stay complete with out glazing bars dovetailed or welded complete all as specified and directed as per drg No TD 088 Sheet 1/17 to 17/17. |
| 158 | S&F Steel ventilator factory made with centre hung shutter including hinges and steel peg stay complete with glazing bars dovetailed or welded complete all as specified and directed as per drg No TD 088 Sheet 1/17 to 17/17. |
| 159 | S&F Pressed steel frame of 105x60 mm section for doors with one or more rebates including necessary fixing lugs, hinges, lock strikes plates etc including PCC 1:3:6 type C-0 using 12.5mm graded crushed stone aggregate as in back filling complete all as directed. |
| 160 | S&F Pressed steel frame of 125 x 60mm section for doors with one or more rebates including necessary fixing lugs, hinges, lock strikes plates etc including PCC 1:3:6 type C-0 using 12.5mm graded crushed stone aggregate as in back filling complete all as directed. |
| 161 | S&F 35mm thick flush shutter solid core construciton with block board core and plywood face panels commercial type on both sides complete all as directed. |
| 162 | S&F 35mm thick IInd class hard wood factory made glazed and skeleton shutter open rebated and prepared to receive glass gauge/(with sash bar) edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass or gauge etc size of members of shutters as specified in SSR Part I section 8 clause 8.24(a) completed all as directed. |
| 163 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire & average width of aperture 1.18mm & fixed with tinned tacks, or galvanished wire staples |
| 164 | S&F 3mm thick sheet glass ordinary quality & glazing with oil putty or wooden beads in square area not exc 0.5 Sqm in each pane, complete, all as specified and directed. |
| 165 | S&F 250mm long aluminium anosized sliding door bolt with hasp staple (bolt type) and fixing clips to sheet cast or extruded section of cast aluminium complete all as directed. |
| 166 | S&F 150 mm extruded aluminium alloy handles, fabricated type complete all as specified and directed. |
| 167 | S&F 200 mm long aluminium anodized, barrel tower bolts of extruded section complete all as specified and directed |
| 168 | S&F 300 mm mild steel ordinary rat tail rod pattern spring including roller and roller plate fixed to wooden/mild steel chowkhat complete all as specified and directed. |
| 169 | Preparation of new wooden surface of any description over 10 cm width and girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 170 | NOTE:- Tenderers may please note that amount of Schedule of Credit as given on Page No. 85 shall be deducted at the time of acceptance of tender to arrive the contract sum. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 12 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender