Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #57719060

Tender For Upkeep Of Outdoor Electric Substation And 11 Kv Power House Under Ge Hisar At Hisar Mil Station

Issued by Statutory Bodies & Commissions/Committees · Hisar, Haryana
Tender Value
20 Lakhs
Estimated cost
Bid Submission
15 Oct 2026
13 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hisar → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Upkeep Of Outdoor Electric Substation And 11 Kv Power House Under Ge Hisar At Hisar Mil Station

BOQ

Name of Work:- UPKEEP OF OUTDOOR ELECTRIC SUBSTATION AND 11 KV POWER HOUSE UNDER GE HISAR AT HISAR MIL STATION
Sl. No. Item Description
1M&L for construction of transformer plinth with PCC Block masonry platform of size 3m x 3m x 1.2 m hight, PCC(1:3:6) type C1 using 20mm graded stone aggregate built in CM 1:4 complete with and including necessary excavation & earth work, PCC 1:4:8 type D-2 as in foundation, rendering 15 mm thick in CM 1:6 on sides and top of the brick work, upto 300 mm below ground level, supply and fixing of 02 Nos MS Channels of size MC 100 for balancing of Transformer embedded in PCC (1:2:4) type B-1, top surface of plateform shall be provided with 100 mm Thick RCC (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 10 mm steel TMT bar, including provn of steps in one side of plateform and all the outer face of platform shall be given with two coat of white wash, complete all as specified and directed.
2M&L for shifting of transformer from 2/4 pole structure to plinth/plinth to MES store, Isolating 11 KV HT supply from the substation and earth the complete system properly, disconnecting complete electric system of the transformer from HT and LT side including earthing strips, disconnecting removing taking down out door transformer of capacity upto 400 KVA from 2/4 pole structure and refixing, installing, commissioning & testing the transformer on plinth complete all as specified directed by Engineer -in-charge.Note:- (a) The rates quoted is deemed to be included for hydra, T&P and manpower and other items required for shifting of transformer.
3Supplying and laying in replacement electrical insulation mat of size 5 mtr x 1 mtr x 2.5 mm thick specification as per IS 15652 2006 all as spefied and directed.
4Taking out the old unserviceable HT Underground XLPE insulated, screened PVC bedded galvanized steel strip armoured electric power cable (heavy duty) with aluminium conductor 11 KV grade (Earthed) of any Size from trenches/wall/floor/road/ culverts or pole etc complete all as specified and directed . Note : Excavation and earth work, duct work, GI pipe for laying of cable and sand cushing/cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately.
5Supply, laying, testing and commissioning in replacement of HT underground XLPE insulated, screened PVC bedded galvanized steel strip armoured electric power cable (heavy duty) with aluminium conductor 11 KV grade (Earthed) of sizes 3 Core 95 Sqmm cable comfirming to IS-7098 Pt-II laid in trenches / walls / ducts / poles complete all as specified and directed.
6All as per Item Sl No 5 above but size of cable 3 Core 120 Sqmm
7Disconnecting and taking down HT UG cable from HT pole / Transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, out door type fixed with and including suitable size of heat shrinkable new jointing kit 11000 voltage grade and aluminium lugs duly crimped with crimping tool for HT XLPE cable size 50 sqmm to 95 sqmm.
8All as per Item Sl No 7 above but size of cable 120 Sqmm to 185 Sqmm 3 Core.
9Disconnecting and taking down HT UG cable from HT pole / Transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, indoor type fixed with and including suitable size of heat shrinkable new jointing kit 11000 voltage grade and aluminium lugs duly crimped with crimping tool for HT XLPE cable size 50 sqmm to 95 sqmm.
10All as per Item Sl No 9 above but size of cable 120 Sqmm to 185 Sqmm 3 Core.
11M&L in replacement for cable jointing Kit for 11KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable HT XLPE cable of size 50 sqmm to 95 sqmm.
12All as per Item Sl No 11 above but size of cable 120 Sqmm to 185 Sqmm 3 Core Please Enable Macros to View BoQ information
13All as per Item Sl No 11 above but size of cable 120 Sqmm to 185 Sqmm 3 Core Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57719060
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20 Lakhs
LAST DATE 15-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Upkeep Of Outdoor Electric Substation And 11 Kv Power House Under Ge Hisar At Hisar Mil Station
Basic Detail
Tender No GE(H)-28/2026-27
Bidding Type Tender
Location
City Hisar
State Haryana
Key Dates
Publish Date 25 Sep 2026
Submission Date 15 Oct 2026
Open Date 17 Oct 2026
Finance
Tender Value 20 Lakhs
Tender Fee 500
EMD 40000
Exemption Available
Document List
58a363df-7d8d-4a89-b26c-9472248ad924.html
BOQ_886886.xls
TENDERGE28.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Oct 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

58a363df-7d8d-4a89-b26c-9472248ad924.html

xls

BOQ_886886.xls

pdf

TENDERGE28.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders