Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #57719054

Tender For Special Rep To Earthing And Lt Panels Other Connected Items And Provn Of Deficient Geysers In Or Qtrs At Sector A Eme School,Vadodara.

Issued by Statutory Bodies & Commissions/Committees · Vadodara, Gujarat
Tender Value
42.71 Lakhs
Estimated cost
Bid Submission
15 Oct 2026
11 days left
EMD
85420
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Vadodara → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Rep To Earthing And Lt Panels Other Connected Items And Provn Of Deficient Geysers In Or Qtrs At Sector A Eme School,Vadodara.

BOQ

Name of Work:- SPECIAL REP TO EARTHING AND LT PANELS OTHER CONNECTED ITEMS AND PROVN OF DEFICIENT GEYSERS IN OR QTRS AT SECTOR A EME SCHOOL,VADODARA.
Sl. No. Item Description
1Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 630 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-(A) INCOMING MCCB adjustable thermal and magnetic of 350 Amps, 4pole, 415 Volts, 36 KA, with rotary macanism - 01 Nos (B) OUTGOING (i) MCCB adjustable thermal and magnetic of 250 Amps, 4pole, 415 Volts, 36 KA, with rotary macanism - 02 Nos (ii) Blank space for MCCBs of same capacity - 01 Nos(ii) Digital Multifuction meter with selector switch and three CT/PT site program of suitable ratio and capacity -01 Set(iv) LED Type Phase indicator lamps for three phases set of three -01 Nos(v) Selector switch - 03 Nos(vi) Busbar chamber having insulated aluminium busbar, each suitable for 630 Amps for three phases and neutral -01 Set
2Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 450 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-(A) INCOMING (i) MCCB, 4 Pole,415V, 50HZ 250 Amps 36 KA adjustable thermal and magnetic with rotary macanism -01 Nos(B) OUTGOING (i) MCCB adjustable thermal and magnetic of 100 Amps, 4pole, 415 Volts, 1 KA - 04 Nos (ii) Blank space for MCCBs of same capacity - 01 Nos(iii) Digital Multifuction meter with selector switch and threeCT/PT of suitable ratio and capacity -01 Set(iv) LED Type Phase indicator lamps for three phases set of three -01 Nos(v) Selector switch - 08 Nos(vi) Busbar chamber having insulated aluminium busbar, each suitable for 450 Amps for three phases and neutral -01 Set
3Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 750 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-(A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ,400 Amps 36 KA micro processor -01 No. (B) OUTGOING (i) MCCB, 4 Pole,415V, 50HZ 250 Amps 36 KA adjustable thermal and magnetic -01 Nos (i) MCCB, 4 Pole,415V, 50HZ 160 Amps 16 KA adjustable thermal and magnetic -02 Nos(ii) MCB, TPN 'C' Series,240V, 50HZ 40 Amps 10KA -03 Nos (iii) MCB, SPN 'C' Series,240V, 50HZ 40 Amps 10KA -02 Nos (iv) Digital Multifuction meter with selector switch and threeCT/PT of suitable ratio and capacity -01 Set(v) LED Type Phase indicator lamps for three phases set of three - 01 set (vi) Busbar chamber having insulated aluminium busbar, each suitable for 750 Amps for three phases and neutral -01 Set (vii) Spare space for MCCB of same capacity -01 Nos
4Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 750 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-(A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ,400 Amps 36 KA micro processor -01 No. (B) OUTGOING (i) MCCB, 4 Pole,415V, 50HZ 250 Amps 36 KA adjustable thermal and magnetic -03 Nos(ii) Digital Multifuction meter with selector switch and threeCT/PT of suitable ratio and capacity -01 Set(ii) LED Type Phase indicator lamps for three phases set of three - 01 set (iv) Busbar chamber having insulated aluminium busbar, each suitable for 750 Amps for three phases and neutral -01 Set (v) Spare space for MCCB of same capacity -01 Nos
5Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 750 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-(A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ,400 Amps 36 KA micro processor -01 No. (B) OUTGOING (i) MCCB, 4 Pole,415V, 50HZ 250 Amps 36 KA adjustable thermal and magnetic -01 Nos (ii) MCCB, 4 Pole,415V, 50HZ 200 Amps 36 KA adjustable thermal and magnetic -02 Nos(iii) MCCB, 4 Pole,415V, 50HZ 100 Amps 36 KA adjustable thermal and magnetic -03 Nos(iv) Change over switch 4 pole,415V,50Hz,200 Amp ,manual with handle(v) MCB, TPN 'C' Series,240V, 50HZ 63 Amps 10KA -10 Nos (vi) MCB, SPN 'C' Series,240V, 50HZ 63 Amps 10KA -06 Nos (vii) MCB, SPN 'C' Series,240V, 50HZ 32 Amps 10KA -06 Nos (viii) Digital Multifuction meter with selector switch and threeCT/PT of suitable ratio and capacity -01 Set(ix) LED Type Phase indicator lamps for three phases set of three - 01 set (x) Busbar chamber having insulated aluminium busbar, each suitable for 750 Amps for three phases and neutral -01 Set (xi) Spare space for MCCB of same capacity -01 Nos
6Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 750 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-(A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ,400 Amps 36 KA micro processor -01 No. (B) OUTGOING (i) MCCB, 4 Pole,415V, 50HZ 250 Amps 36 KA adjustable thermal and magnetic -04 Nos (ii) MCB, TPN 'C' Series,240V, 50HZ 63 Amps 10KA -2 Nos (iii) Digital Multifuction meter with selector switch and threeCT/PT of suitable ratio and capacity -01 Set(iv) LED Type Phase indicator lamps for three phases set of three - 01 set (v) Busbar chamber having insulated aluminium busbar, each suitable for 750 Amps for three phases and neutral -01 Set (vi) Spare space for MCCB of same capacity -01 Nos
7Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using galvanized earth lead wire 32 x 6 mm dia by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron medium grade pipe 40mm bore in wall/floor/and GI Pipe 20 mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I).Notes (a) The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made.(b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.(c) If the testing result of earthing is not found below 3 Ω then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account.(d) Earthing work will be carried out in presence of MES representative.(e) Testing Meggar with calibration report shall be provided by the contractor. (f) Earth Test report will be submitted to AGE Sub Div for record.
8Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using galvanised earth strip 4 mm by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron medium grade pipe 40mm bore in wall/floor/and GI Pipe 20 mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I).Notes :(a) The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made.(b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.(c) If the testing result of earthing work is not found below 3 Ω then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account.(d) Earthing work will be carried out in presence of MES representative. (e) Testing Meggar with calibration report shall be provided by the contractor. (f) Earth Test report will be submitted to AGE Sub Div for record.
9Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using galvanized earth lead wire 25 x 4 mm dia by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron medium grade pipe 40mm bore in wall/floor/and GI Pipe 20 mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I).Notes (a) The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made.(b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.(c) If the testing result of earthing is not found below 3 Ω then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account.(d) Earthing work will be carried out in presence of MES representative. (e) Testing Meggar with calibration report shall be provided by the contractor. (f) Earth Test report will be submitted to AGE Sub Div for record.
10M & L in repair for fabrication of bus bar chamber of size 80cmx60cmx40cm for 415 volts 3 phase 4 wire system with MCCB 250A ,25 KA ,4 pole, out going MCCB 63 Amps - 02 Nos ,outdoor type, with digital volt amp meter ,double door, withpedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 1.2 mtr above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge .Note :- Comprising of 4 nos. Aluminium bus bar 200 Amp for phases & 100 Amp for neutral mounted on DMC/ porcelain insulator support complete all as specified and directed.
11M & L in repair for fabrication of bus bar chamber of size 80cmx60cmx40cm for 415 volts 3 phase 4 wire system with MCCB 100A 16 KA 4 pole, outdoor type, double door, withpedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 1.2 mtr above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge .Note :- Comprising of 4 nos. Aluminium bus bar 200 Amp for phases & 100 Amp for neutral mounted on DMC/ porcelain insulator support complete all as specified and directed.
12Supply and Laying including jointing and testing electric under ground LT cable PVC/XLPE insulated armoured aluminium conductor cable 1100 volts grade in trenches , ducts, pipe on walls, poles of following sizes:-
1310 Sqmm 2 core
1425 sq mm 3.5 core
1535 Sq mm 3.5 core
1650 Sqmm 3.5 core.
1770 Sqmm 3.5 core
1895 sqmm 3.5 core.
19120 Sqmm 3.5 core.
20Taking out existing LT under ground cable 1100 volts grade PVC insulated armoured aluminium conductor from tranches/ducts/pipe, on wall, poles of following size and removing unserviceable cable from site to store :-
2110 Sqmm 2 core
2225 sq mm 3.5 core
2335 Sq mm 3.5 core
2450 Sqmm 3.5 core.
2570 Sqmm 3.5 core
2695 sqmm 3.5 core.
27120 Sqmm 3.5 core.
28Excavation in trenches nexc 1.5 mtr in depth for taking out cable / pipe line n.exc 10 sq mtr on plan and n.exc 1.5 mtr depth and getting out in soft/loose soil.
29Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm.
30Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point.
31M & L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable all as specified.
32M & L well burnt bricks sub class 'B' as in protection of cable laid dry, flat abutting each other width wise all as directed
33M&L for GI tubing light grade fixed on wall/pole laid in trenches/under road of the following sizes :-
3440 mm dia bore
3550 mm dia bore
36M&L Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
37M&L Galvanised iron strip 25 x 3.15mm with saddles and fixing screws etc. for inter connected conductors
38M&L for Air termination, single pointed aluminium rod 12mm dia and 300mm long with complete fittings.
39M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified
40M&L sub main wiring in casing caping with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLSH, 02 runs of 01 Single core of size 2.5 sqmm (for main current) drawn in & incl PVCcasing caping not less than 20 mm ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 2.5 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green Note : Two runs of single core 2.5 sqmm and one run of 2.5 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
41S&F Switch socket combination 3 pin 16A, flush type
42S&F Surface Mounting Plastic Boxes 4 M Box (14.5x8.9) cm / (5X3)
43Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe ,plug top etc .
44S & F 16 mm outer dia CPVC pipes SDR 11 & plain CPVC SDR11 including all fittings on wall/ceiling or laying in floors complete all as specified and directed.
45S & F CP bib Tap fancy type 15 mm bore cast copper alloy with round operating knob screw down for CPVC pipe complete all as specified .
46M & L for cutting existing steel tubing for alterations or additions (Each cut measured) and inserting new Tee, bend, elbow etc up to 15 mm dia includingCPVC tee size 15x15x15mm
47S & F CP Stop valve fancy type 15 mm bore cast copper alloyscrewed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57719054
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42.71 Lakhs
LAST DATE 15-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Rep To Earthing And Lt Panels Other Connected Items And Provn Of Deficient Geysers In Or Qtrs At Sector A Eme School,Vadodara.
Basic Detail
Tender No 8133
Bidding Type Tender
Location
City Vadodara
State Gujarat
Key Dates
Publish Date 25 Sep 2026
Submission Date 15 Oct 2026
Open Date 16 Oct 2026
Finance
Tender Value 42.71 Lakhs
Tender Fee 500
EMD 85420
Exemption Available
Document List
5639969b-2ac3-4893-8922-c4c6ffbd565f.html
BOQ_886948.xls
Tendernotice_1.pdf
Tenderpages8133.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Oct 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

5639969b-2ac3-4893-8922-c4c6ffbd565f.html

xls

BOQ_886948.xls

pdf

Tendernotice_1.pdf

pdf

Tenderpages8133.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders