Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #57718064

Tender For Installation Of Compact Sub Station 315 Kva Transformers At Sri Ganganagar Mil Stn

Issued by Statutory Bodies & Commissions/Committees · Ganganagar, Rajasthan
Tender Value
43.53 Lakhs
Estimated cost
Bid Submission
09 Oct 2026
5 days left
EMD
87060
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganganagar → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Installation Of Compact Sub Station 315 Kva Transformers At Sri Ganganagar Mil Stn

BOQ

Name of Work:- INSTALLATION OF COMPACT SUB STATION 315 KVA TRANSFORMERS AT SRI GANGANAGAR MIL STN
Sl. No. Item Description
1Supply, installation, testing and commissioning of distribution netwrok, 11 KV outdoor compact Sub Station totally factory assembled consisting of 1 Way RMU type, 1 No, 11 KV/433V, 315 KVA with Oil type transformer, 1 Set of LT device as under. Compartment 11 KV, 630A, 25KA/1 Sec indoor type non-extensible, SF6 gas insulated Ring Main unit sealed pressure system criterion in accordance with the IEC : 60298, 62271-202. IAC category IAC-AFL. The switchgear includes the following HV cubicles.1. The indoor non-extensible SF6 insulated RMU fully motorised consist of 1 No Load Break Switch with self powered relay for protection of transformer as ICOG. Rated for Voltage 12 KV, 400A, 25 KA for 1 sec.(a) Rated voltage should be 12 KV.(b) Rated power frequency voltage 28 KV.(c) Rated lightening withstand voltage 75 KV.(d) Rated current for Ring Main Feeder 630 Amps.(e) Rated current for LBS feeder 400 Amps.(f) Rated short time current-25 KA/1 Sec.(g) Rated Short time making current - 50 KA.(h) Ambient temp (0 deg C to +40 deg C).(j) Rated internal arc rating 21 KA for 1 sec for tank and cable box category IAC-AFL.(k) RMU shall be provided with protection CTs rated for 30/1 Amps, Class-10P10 accuracy, 2.5 VA burden for circuit breaker.(l) The feeder shall be self powered/powered by external source and shall be provided with OC+EF protection for transformer and shall have serial port for communication on modbus protocol.(m) Dead short Circuit life of VI - 40 Nos.2. Transformer (Oil type) Three phase.(a) Standard IS : 2026, IS 1180.(b) Vector Group : Dyn11.(c) Rating : 315 KVA(d) Cooling System : ONAN(e) Winding : Copper(f) Magnetic Core : Prime grade of M4 or better(g) High voltage : 11 KV - 50 Hz(h) System highest Voltage : 12 KV at the HV side. Please Enable Macros to View BoQ information
2Supply, installation, testing and commissioning of distribution netwrok, 11 KV outdoor compact Sub Station totally factory assembled consisting of 1 Way RMU type, 1 No, 11 KV/433V, 315 KVA with Oil type transformer, 1 Set of LT device as under. Compartment 11 KV, 630A, 25KA/1 Sec indoor type non-extensible, SF6 gas insulated Ring Main unit sealed pressure system criterion in accordance with the IEC : 60298, 62271-202. IAC category IAC-AFL. The switchgear includes the following HV cubicles.1. The indoor non-extensible SF6 insulated RMU fully motorised consist of 1 No Load Break Switch with self powered relay for protection of transformer as ICOG. Rated for Voltage 12 KV, 400A, 25 KA for 1 sec.(a) Rated voltage should be 12 KV.(b) Rated power frequency voltage 28 KV.(c) Rated lightening withstand voltage 75 KV.(d) Rated current for Ring Main Feeder 630 Amps.(e) Rated current for LBS feeder 400 Amps.(f) Rated short time current-25 KA/1 Sec.(g) Rated Short time making current - 50 KA.(h) Ambient temp (0 deg C to +40 deg C).(j) Rated internal arc rating 21 KA for 1 sec for tank and cable box category IAC-AFL.(k) RMU shall be provided with protection CTs rated for 30/1 Amps, Class-10P10 accuracy, 2.5 VA burden for circuit breaker.(l) The feeder shall be self powered/powered by external source and shall be provided with OC+EF protection for transformer and shall have serial port for communication on modbus protocol.(m) Dead short Circuit life of VI - 40 Nos.2. Transformer (Oil type) Three phase.(a) Standard IS : 2026, IS 1180.(b) Vector Group : Dyn11.(c) Rating : 315 KVA(d) Cooling System : ONAN(e) Winding : Copper(f) Magnetic Core : Prime grade of M4 or better(g) High voltage : 11 KV - 50 Hz(h) System highest Voltage : 12 KV at the HV side. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57718064
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.53 Lakhs
LAST DATE 09-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Installation Of Compact Sub Station 315 Kva Transformers At Sri Ganganagar Mil Stn
Basic Detail
Tender No CA NO CWE SGNR/TOKEN-26 OF 2026-27
Bidding Type Tender
Location
City Ganganagar
State Rajasthan
Key Dates
Publish Date 25 Sep 2026
Submission Date 09 Oct 2026
Open Date 10 Oct 2026
Finance
Tender Value 43.53 Lakhs
Tender Fee 500
EMD 87060
Exemption Available
Document List
ba5be5f9-658f-4b52-a95e-2de2c11dd43c.html
BOQ_887061.xls
Tendernotice_1.pdf
Tender_26.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Oct 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

ba5be5f9-658f-4b52-a95e-2de2c11dd43c.html

xls

BOQ_887061.xls

pdf

Tendernotice_1.pdf

pdf

Tender_26.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders