| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning of distribution netwrok, 11 KV outdoor compact Sub Station totally factory assembled consisting of 1 Way RMU type, 1 No, 11 KV/433V, 315 KVA with Oil type transformer, 1 Set of LT device as under. Compartment 11 KV, 630A, 25KA/1 Sec indoor type non-extensible, SF6 gas insulated Ring Main unit sealed pressure system criterion in accordance with the IEC : 60298, 62271-202. IAC category IAC-AFL. The switchgear includes the following HV cubicles.1. The indoor non-extensible SF6 insulated RMU fully motorised consist of 1 No Load Break Switch with self powered relay for protection of transformer as ICOG. Rated for Voltage 12 KV, 400A, 25 KA for 1 sec.(a) Rated voltage should be 12 KV.(b) Rated power frequency voltage 28 KV.(c) Rated lightening withstand voltage 75 KV.(d) Rated current for Ring Main Feeder 630 Amps.(e) Rated current for LBS feeder 400 Amps.(f) Rated short time current-25 KA/1 Sec.(g) Rated Short time making current - 50 KA.(h) Ambient temp (0 deg C to +40 deg C).(j) Rated internal arc rating 21 KA for 1 sec for tank and cable box category IAC-AFL.(k) RMU shall be provided with protection CTs rated for 30/1 Amps, Class-10P10 accuracy, 2.5 VA burden for circuit breaker.(l) The feeder shall be self powered/powered by external source and shall be provided with OC+EF protection for transformer and shall have serial port for communication on modbus protocol.(m) Dead short Circuit life of VI - 40 Nos.2. Transformer (Oil type) Three phase.(a) Standard IS : 2026, IS 1180.(b) Vector Group : Dyn11.(c) Rating : 315 KVA(d) Cooling System : ONAN(e) Winding : Copper(f) Magnetic Core : Prime grade of M4 or better(g) High voltage : 11 KV - 50 Hz(h) System highest Voltage : 12 KV at the HV side. Please Enable Macros to View BoQ information |
| 2 | Supply, installation, testing and commissioning of distribution netwrok, 11 KV outdoor compact Sub Station totally factory assembled consisting of 1 Way RMU type, 1 No, 11 KV/433V, 315 KVA with Oil type transformer, 1 Set of LT device as under. Compartment 11 KV, 630A, 25KA/1 Sec indoor type non-extensible, SF6 gas insulated Ring Main unit sealed pressure system criterion in accordance with the IEC : 60298, 62271-202. IAC category IAC-AFL. The switchgear includes the following HV cubicles.1. The indoor non-extensible SF6 insulated RMU fully motorised consist of 1 No Load Break Switch with self powered relay for protection of transformer as ICOG. Rated for Voltage 12 KV, 400A, 25 KA for 1 sec.(a) Rated voltage should be 12 KV.(b) Rated power frequency voltage 28 KV.(c) Rated lightening withstand voltage 75 KV.(d) Rated current for Ring Main Feeder 630 Amps.(e) Rated current for LBS feeder 400 Amps.(f) Rated short time current-25 KA/1 Sec.(g) Rated Short time making current - 50 KA.(h) Ambient temp (0 deg C to +40 deg C).(j) Rated internal arc rating 21 KA for 1 sec for tank and cable box category IAC-AFL.(k) RMU shall be provided with protection CTs rated for 30/1 Amps, Class-10P10 accuracy, 2.5 VA burden for circuit breaker.(l) The feeder shall be self powered/powered by external source and shall be provided with OC+EF protection for transformer and shall have serial port for communication on modbus protocol.(m) Dead short Circuit life of VI - 40 Nos.2. Transformer (Oil type) Three phase.(a) Standard IS : 2026, IS 1180.(b) Vector Group : Dyn11.(c) Rating : 315 KVA(d) Cooling System : ONAN(e) Winding : Copper(f) Magnetic Core : Prime grade of M4 or better(g) High voltage : 11 KV - 50 Hz(h) System highest Voltage : 12 KV at the HV side. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender