Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57718058

Tender For Provn Of Power Supply To Arrester Barriers At Afs Yelahanka.

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
43.21 Lakhs
Estimated cost
Bid Submission
16 Oct 2026
19 days left
EMD
86420
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Power Supply To Arrester Barriers At Afs Yelahanka.

BOQ

Name of Work:- PROVN OF POWER SUPPLY TO ARRESTER BARRIERS AT AFS YELAHANKA.
Sl. No. Item Description
1Fabricate, supply, install testing and commissioning of LT panel indoor type 415 Volts, 50 Hz, 3 phase, 4 wire suitable for accommodating the following accessories totally enclosed self supporting structure fully compartmentalized suitable for indoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 2mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for aluminium bus bars 400 Amps capacity, hinged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following accessories suitable for incoming/outgoing arrangements complete all as specified and directed:- (a) MCCB 4 P 200 Amps ,25 KA, 415 Amps (thermal and magnetic settings ) (ICS= 100% ICU), Incomer -1 No(b) 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA (thermal and magnetic settings ) (ICS= 100% ICU),-01 Nos(c) 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity 25 KA,(thermal and magnetic settings ) (ICS= 100% ICU)-01 Nos(f) Digital VAF Meter-01 Nos (g) CT's 200/5- set of 3 No(h) LED type Indication lamps (RYB)-one set(for each incoming and outgoing) Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr In Charge /GE before commencement of work. (ii) Switch gear and connected items should be of approved make. (iii) Bottom portion of panel should be 30 CM above from the ground level.
2Fabricate, supply ,install testing and commissioning of LT panel outdoor type 415 Volts, 50 Hz, 3 phase, 4 wire Suitable for accommodating the following accessories totally enclosed self supporting structure fully compartmentalized suitable for outdoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable monting arrangement for aluminium bus bars 200 Amps capacity, hinged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following accessories suitable for incoming/outgoing arrangements complete all as specified and directed:-(a) 4 Pole MCCB 125Amp, 50 Hz, 415 V with rupturing capacity 25 KA with thermal and magnetic settings ,-01 No , Incomer (c) Bus bar of capacity 200 Amps (RYBN) with 04 Nos of outgoing (d)Multifunctional VAF meter -01 Nos (f) CT's 200/5- set of 3 No(g) LED type Indication lamps (RYB)-one set(for each incoming and outgoing) Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr In Charge /GE before commencement of work. (ii) Switch gear and connected items should be of approved make. (iii) Bottom portion of panel should be 30 CM above from the ground level.
3Fabricate, supply ,install testing and commissioning of LT panel Outdoor type 415 Volts, 50 Hz, 3 phase, 4 wire for accommodating the following accessories totally enclosed self supporting structure fully compartmentalized suitable for outdoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable monting arrangement for aluminium bus bars 400 Amps capacity, hinged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following accessories suitable for incoming/outgoing arrangements complete all as specified and directed:- (a) MCCB 4 Pole 315 Amps 25 KA , Incomer -1 No(b) 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 25 KA,(thermal and magnetic settings ) (ICS= 100% ICU) -1 No(c) 4 Pole MCCB 160 Amps 50 Hz , 415V with rupturing capacity 25 KA, (thermal and magnetic settings ) (ICS= 100% ICU) -01(c) 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity25 KA,(thermal and magnetic settings ) (ICS= 100% ICU) -01 No(d) MCB TPN 63 Amps 16 KA -03 Nos (d) Multifunctional VAF Meter -01 No(e) Digital Ammeter-01 No(f) CT's 315/5- set of 3 No(g) LED type Indication lamps (RYB)-one set (For each incoming and outgoing ) Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr In Charge /GE before commencement of work. (ii) Switch gear and connected items should be of approved make. (iii) Bottom portion of panel should be 45 CM above from the ground level.
4Fabricate, supply ,install testing and commissioning of LT panel outdoor type 415 Volts, 50 Hz, 3 phase, 4 wire for accommodating the following accessories totally enclosed self supporting structure fully compartmentalized suitable for indoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable monting arrangement for aluminium bus bars 300 Amps capacity, hinged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following accessories suitable for incoming/outgoing arrangements complete all as specified and directed:- (a) 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA,(thermal and magnetic settings ) (ICS= 100% ICU) Incomer -1 No(b) 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA(thermal and magnetic settings ) (ICS= 100% ICU)-02 Nos (c) 4 Pole MCB 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA,(thermal and magnetic settings ) (ICS= 100% ICU) -01 No(d) Digital Multifunctional VAF Meter -01Nos (e) CT's 100/5- set of 3 (g) LED type Indication lamps (RYB)-one set of 03 (for each incoming and outgoing)Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr In Charge /GE before commencement of work. (ii) Switch gear and connected items should be of approved make. (iii) Bottom portion of panel should be 30 CM above from the ground level.
5Supply and laying in trenches, LT underground cable of size 25 Sqmm 4 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as specified and directed.
6All as per item No 6 here-in-before but 70 Sqmm 3.5 core
7All as per item No 6 here-in-before but 95 Sqmm 3.5 core
8Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil all as specified and as directed.
9Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, leveling, watering and well ramming in layers complete all as specified and as directed.
10Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.
11Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm all as specified and as directed.
12Supply and laying GI tubing light grade 80mm dia in trenches/fixing on pole /wall/crossing in drain etc.for protection of UG cable all as specified and as directed.
13M & L for boring of holes under runway (minimum 3.5 Mtrs depth), pavement, hardstanding by trenchless technology and necessary machine including GI pipe of 50/80/100mm dia suitable for 0.4mpa working pressure all as specified and as directed. Please Enable Macros to View BoQ information
14M & L for boring of holes under runway (minimum 3.5 Mtrs depth), pavement, hardstanding by trenchless technology and necessary machine including GI pipe of 50/80/100mm dia suitable for 0.4mpa working pressure all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57718058
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.21 Lakhs
LAST DATE 16-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Power Supply To Arrester Barriers At Afs Yelahanka.
Basic Detail
Tender No 8588/E8
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 25 Sep 2026
Submission Date 16 Oct 2026
Open Date 23 Oct 2026
Finance
Tender Value 43.21 Lakhs
Tender Fee 500
EMD 86420
Exemption Available
Document List
Binder1.pdf
BOQ_887055.xls
cb742efb-38b1-47cb-bd32-f9af0f7f5bf0.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
pdf

Binder1.pdf

xls

BOQ_887055.xls

html

cb742efb-38b1-47cb-bd32-f9af0f7f5bf0.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders