Tender For Repair/Maintenance To External Water Supply Mes Installations At Nad Depot, Nad Colony, Old Mo(V), Dega, Bv Yard, Viswakarma, Cqea, Dega(V), Abe Park, Naval Dockyard, installation Circar, Naval Park And Nausena Baugh And Adjacent Areas Wit
Tender Overview
Project Description
Tender for Repair/Maintenance To External Water Supply Mes Installations At Nad Depot, Nad Colony, Old Mo(V), Dega, Bv Yard, Viswakarma, Cqea, Dega(V), Abe Park, Naval Dockyard, installation Circar, Naval Park And Nausena Baugh And Adjacent Areas With Certain Water Supply Works Under Ge (Utility Ii) Visakhapatnam
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches, n exc 1.5 m wide or n exc 10 sq m on plan and n exc 1.5 m in depth for foundation etc and getting out in soft / loose soil for taking out pipe line, complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in Soft/loose soil, complete all as specified and directed. |
| 3 | Removing excavated materials not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed. |
| 4 | Cutting hard standing / road for laying of pipe, not exc 30 cms wide and not exc 30 cms deep, and getting out in hard/dense soil, etc, complete all as specified and as directed. |
| 5 | Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded aggregate) not exc 30 cms wide and not exc 30 cms for filling and making good of disturbed surfaces of road/hard standing etc, complete all as specified and as directed. |
| 6 | Supply and fix in repairs rubber insertion/gasket 6mm thick for 150mm dia pipe joints, complete all as specified and directed. |
| 7 | Taking out from trenches or taking down from wall GI steel tubing and connections, 20 mm bore, setting aside and cleaning the serviceable pipe for re-laying / re-fixing or removal of old unserviceable pipe from site, complete all as specified and directed. |
| 8 | All as per Srl item No 07.00 here in before but for 25 mm bore of pipe. |
| 9 | All as per Srl item No 07.00 here in before but for 40 mm bore of pipe. |
| 10 | All as per Srl item No 07.00 here in before but for 50 mm bore of pipe. |
| 11 | Relaying of old serviceable GI pipe 20mm bore with spigot and socket ends in new or old position in any length, laid in trenches after cleaning of inner surface and applying with two coats of black bituminous paint (sutiable for drinking water purpose) including testing, complete all as specified and directed. |
| 12 | All as per Srl item No 11.00 here-in-before but for 25 mm bore. |
| 13 | All as per Srl item No 11.00 here-in-before but for 40 mm bore. |
| 14 | All as per Srl item No 11.00 here-in-before but for 50 mm bore. |
| 15 | Supplying and fixing of 20 mm bore GI tubing, medium grade with all new fittings, fixed to walls and ceilings or laid in floors/trenches including necessary testing, complete all as specified and directed. |
| 16 | All as per Srl item No 15.00 here in before but for 25 mm bore of pipe. |
| 17 | All as per Srl item No 15.00 here in before but for 40 mm bore of pipe. |
| 18 | All as per Srl item No 15.00 here in before but for 50 mm bore of pipe. |
| 19 | M&L for Minor leakage rectification wk of water supply line for GI pipe of size ranging from 15 to 25mm complete within 4-6Hrs, complete all as specified and directed. |
| 20 | All as per Srl item No.19.00 above but for 40/ 50mm bore GI pipe. |
| 21 | Supply and fix in repair 20mm bore, gun-metal, gate valves, with iron wheel head, screwed both ends for iron pipe and fixed after taking down old unserviceable one, complete all as specified and directed. |
| 22 | All as per Srl item No. 21.00 above but for 25 mm bore. |
| 23 | All as per Srl item No. 21.00 above but for 40 mm bore. |
| 24 | All as per Srl item No. 21.00 above but for 50 mm bore. |
| 25 | Material and labour mild steel in form of bars /angles / pipe and welding works to fabricate net frame for roof shed / base channels of pump / supporting coloumns of rain pump delivery pipes, complete all as specified and directed. |
| 26 | Supply and fixing 80mm bore GI tubing, medium grade with all new fittings as required complete fixed to walls and ceilings or laid in floors/trenches including testing after taking down old unserviceable pipe, complete all as specified and directed. |
| 27 | Supply and fixing 100mm bore GI tubing, medium grade with all new fittings as required complete fixed to walls and ceilings or laid in floors/trenches including testing after taking down old unserviceable pipe, complete all as specified and directed. |
| 28 | M&L for brick work with Sub class B Brick straight or curved on plain exc 6 M mean radius build in cement mortor 1:6, complete all as specified and directed |
| 29 | Supply and fix in repair MS ERW 100 mm pipe, complete all as specified and as directed |
| 30 | Supply and Fixing in repair Air termination single pointed aluminium rod 12mm dia and 300 mm long single pointed at top and mounted on GI pipe with two numbers of MS clamp of sutiable size and connecting up with Aluminium strip complete with clamps and all accessories, complete all as specified and as directed. Note:- GI pipe for termination rods to be measured and paid separately. |
| 31 | Supply and fixing in repair of aluminium strip size 25x3.15 mm with saddles and fixing screws for roof conductors and down conductors above ground fixed to roof by means of stand of hold fast placed on PCC blocks/insulated blocks and fixed to walls/ parapet on insulated saddles, complete all as specified and as directed. Note:- Aluminium strip in roof conductors shall not be directely fixed/touching on roof surface. |
| 32 | Supply and fixing in repair Test point terminal block made of gun metal or phosphorous bronze size 75x75x25 mm grilled and screwed including 3 nos of 8 mm dia 25 mm long hexagonal head brass screw, complete all as specified and as directed |
| 33 | Supply and fixing in repair of GI strip 32x6mm burried in ground 150mm below normal ground level including connecting up with earth electrode plates of earthing on both ends with GI nuts, bolts and washers in addition to weilding and also including all excavation earth work and returing filling, compacting etc, complete all as specified and directed. Note:- Earthing strip shall not pass through or be enclosed/encased into any metallic pipe. |
| 34 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron strip 32x6mm, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways, complete all as specified and directed. |
| 35 | Materials & labour for earthing complete with galvanized earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below normal ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth lead wire 4.0 mm dia of by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe(light grade), alternate layers of charcoal and salt, including 20 mm bore GI tubing for watering to earth electrode, earth lead connected to test point/ distribution panel /feeder pillar etc as directed including necessary earth work, concrete pit with PCC (1:3:6) type C1, pre cast RCC(1:1:5:3) type A1 cover slab duly reinforced with 8 mm dia TMT bar 150mm c/c both way and two numbers lifting handle made of TMT bar and set in cement mortar (1:4), funnel, wire mesh, all as shown in electrical plate No 5 of SSR part-1 and testing on completion including taking out old earthing, complete all as specified and directed. |
| 36 | Supply and fixing in repair 40mm bore, galvanised steel water tubing, light grade for fixing up of the air termination rod including necessary clamps etc, complete all as specified and directed. |
| 37 | Supplying, fixing in repairs,chequer plate of 6mm thick for covering the duct of cable including cutting in required dimension duct, complete all as specified and directed.. |
| 38 | S&F wiring for circuit / submain wiring along with earth wire with the of size 4x 6sqmm + 1x 6 sqmm earth wire of FRLSH pvc insulated copper conductor single core cable in surface / recessed as reqd in pvc conduit, complete all as specified and directed. |
| 39 | S&F wiring for circuit / submain wiring along with earth wire with the of size 4x 10sqmm + 1x 10 sqmm earth wire of FRLSH pvc insulated copper conductor single core cable in surface / recessed as reqd in pvc conduit, complete all as specified and directed. |
| 40 | S&F wiring for circuit / submain wiring along with earth wire with the of size 4x 25sqmm + 1x 25 sqmm earth wire of FRLSH pvc insulated copper conductor single core cable in surface / recessed as reqd in pvc conduit, complete all as specified and directed. |
| 41 | M&L for preparation of old iron surface for painting over 10 cm in width or grith, complete all as specified and directed. |
| 42 | M&L for painting of old iron surface with red oxide zinc chrome primer over 10 cm in width or grith, complete all as specified and directed. |
| 43 | M&L for painting of old iron surface with synthetic enamel paint over 10 cm in width or grith, complete all as specified and directed. |
| 44 | Material and Labour for reparing/replacement of locking arrangement of LT Panel including necessary fixing arrangement including taking out unserviceable one, complete all as specified and directed. |
| 45 | Servicing of LT panel including replacement of burnt out lugs, scraping the bus bar chamber with ewary paper, cleaning the bus bar panel with CTC, remove the burnt out electrical wiring and replacement of bolt, nuts, washer and new wiring for metering eqpt, phase sequence RYB with bus bar insulation tapes, heating with blower, reconnecting, testing and commissioning, complete all as specified and directed.Note:- Cost of Nuts, bolts, washers, insulation tapes, wiring & other connecting items shall be included in unit rate. |
| 46 | Supply and fixing in repair connection and testing MCCB, 4 pole, 63 Amp capacity, 16 KA rupturing capacity, AC 415 volts with fixed thermal and magnetic settings including taking down old unserviceable MCCB, complete all as specified and directed.. |
| 47 | All as per Srl item No.46.00 above but for 100 Amp capacity MCCB. |
| 48 | Supplying, fixing, connection and testing MCCB, 4 pole, 160 Amp capacity, 36 KA rupturing capacity, AC 415 volts with with Microprocessor release including taking down old unserviceable MCCB, complete all as specified and directed. |
| 49 | All as per Srl item No.48.00 above but for 250 Amp capacity MCCB. |
| 50 | Supply and fix in replacement of old unserviceable aluminium busbar chamber/Junction box of capacity 63 A and 4 pole, complete all as specified and directed. |
| 51 | Supply and fix in replacement of old unserviceable aluminium busbar chamber/Junction box of capacity 100 A and 4 pole, complete all as specified and directed. |
| 52 | Supply and fix in replacement of old unserviceable aluminium busbar chamber/Junction box of capacity 200 A and 4 pole, complete all as specified and directed. |
| 53 | M & L for MS clamps, made out of FI, of adequate size and thickness, bend to shape as requited, drilling, bolting, etc complete, for fixing as in gi pipe, cables and the like, including preparing new steel and iron surfaces and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and directed. |
| 54 | Supply and fix, in repair LED street light fitting 90 watt 230 volt ac outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver lampbracket, with impact and corrosion resistant including thermal management in multiple optics in IP 65/66, complete all as specified and directed. |
| 55 | Supply and fix, in repair LED flood light fitting 200 watt 230 volt ac outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver with impact and corrosion resistant including thermal management in multiple optics in IP 66, complete all as specified and directed. |
| 56 | Supply & fix in repair, connect, testing and commissioning surface mounted modular type multifunctional digital type timer switch for street light for 24 hrs operation including connection with existing serviceable DB and programming, complete all as specified and as directed. |
| 57 | Supply and fixing in repair compact type Wall mounted Street light Timer Panel with power coated mild steel enclousure for 415 Volt to be fixed on pole/Wall with provision of bus bar, Power Contractor 65 Amp, MC 63 Amp TPN, Digital Timer switch complete fixed with mild steel clamp, nut & bolt and including taking down old unserviceable one, complete all as specified and directed. |
| 58 | Supply and fixing in repair LED post top lantern LED type 40 watt 230 volt ac outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp including taking out old unserviceable/broken light fittings, complete all as specified and directed. |
| 59 | Taking down carefully copper/ aluminium point wiring (light, fan, call bell, socket or power) complete, including fittings and fixtures such as switches, ceiling rose, pendants, holders, regulators, sockets, light fitting etc. & removing from site and making good the disturbed surfaces of wall, ceiling etc. complete all as specified and directed |
| 60 | M & L for concealed point wiring complete with 1.5 sq mm FRLSH,PVC insulated multi standard copper conductor single core cable 1100 volts grade,drawn into non metalic PVC rigid conduit medium grade of size not less than 20mm bore and conduit accessories fixed on wall roof etc, and including provn of PVC insulated 1.5 sq mm copper conductor cable for each continuity and connected to common earth dolly and pressed metallic modular box for housing the modular switches socket,outlet etc, completeall as specified and directed:- |
| 61 | One light point controled by one, one way 5 Amp switch |
| 62 | One fan point controlled by one, one way 5 Amp switch |
| 63 | One 5 pin socket outlet 05 Amp on independent board . |
| 64 | One 5 pin socket outlet 05 Amp on same board . |
| 65 | One bell/buzzer point controlled by one push button same board with other switch or independent |
| 66 | All as per item No 60 here-in-before but for one 15 Amps socket outlet but using 2.5 sq mm,copper conductor with 1.5 sq mm, PVC insulated single core cable for earth continuity conductor. |
| 67 | M & L concealed sub main wiring complete with 2 runs of 4 sq mm,single core, FRLS PVC insulated,unsheathed cable,1100 volts grade,multi standard with copper conductor drawn through and including PVC conduit pipe and accessories on surface wall/floors/concealed etc. with one run of PVC insulated 4 sq mm copper conductor for earth continuity conductor including taking down old unserviceble wiring, complete all as specified and directed Note :- Two runs of cable one run of conduit and one run of copper wire shall be measured as one unit length. |
| 68 | M & L concealed sub main wiring complete with 2 runs of 6 sq mm,single core,FRLS PVC insulated,unsheathed cable,1100 volts grade,multi standard with copper conductor drawn through and including PVC conduit pipe and accessories on surface wall/floors/concealed etc. with one run of PVC insulated 6 sq mm copper conductor for earth continuity conductor including taking down old unserviceable wiring, complete all as specified and directed Note :- Two runs of cable one run of conduit and one run of copper wire shall be measured as one unit length. |
| 69 | Supply & fix in repair Modular switch, one way, 6 Amp, 1 module, complete all as specified and directed. |
| 70 | Supply & fix in repair Modular switch, one way, 16 Amp, 1 module, complete all as specified and directed. |
| 71 | Supply & fix in repair Modular switch 2 way, 6A, 1 Module, complete all as specified and directed. |
| 72 | Supply & fix in repair Modular Bell push 6A,1 Module, complete all as specified and directed. |
| 73 | Supply & fix in repair Modular socket, 6A-2/3 pin combined 2 Module, complete all as specified and directed. |
| 74 | Supply & fix in repair Modular socket, 6A/16A-2/3 pin combined 2 Module, complete all as specified and directed. |
| 75 | Supply & fix in repair Modular fan steep regulator, 120 watt, 2 module, complete all as specified and directed. |
| 76 | Supply & fix in repair Modular white cover plate with frame- 1 Module, complete all as specified and directed. |
| 77 | Supply & fix in repair Modular white cover plate with frame- 2 Module, complete all as specified and directed. |
| 78 | Supply & fix in repair Modular white cover plate with frame- 3 Module, complete all as specified and directed. |
| 79 | Supply & fix in repair Modular white cover plate with frame- 4 Module, complete all as specified and directed. |
| 80 | Supply & fix in repair Modular white cover plate with frame- 6 Module, complete all as specified and directed. |
| 81 | Supply & fix in repair Modular white cover plate with frame- 8 Module, complete all as specified and directed. |
| 82 | Supply & fix in repair calling bell SP 230 volts and taking down U/S call bell, Musical type, complete all as specified and directed. |
| 83 | Supply & fix in repair ceiling rose, 3 terminals, surface bakelite / PVC / Polycarbonate, isolated body to be fixed on wall/ceiling, complete all as specified and directed. |
| 84 | Supply & fix in repair PVC poly carbonate round blocks 10 cm dia, complete all as specified and directed. |
| 85 | Supply & fix in repair LED tube light fitting, 1 x 20 watt with connector block etc. complete with all accessories and connecting the same to ceiling rose with using copper conductor flexible twisted twin core cable and fixing the light fitting to walls / roof, complete all as specified and directed. |
| 86 | Supply & fix in repair lamp Holder insulated body with back plate angle/straight type suitable for batten, complete all as specified and directed. |
| 87 | Supply & fix in repair LED Blub 10 watt Self Ballasted Retrofit type lamp with PBT body shell and DC Diffuser CCT 6500 K with fitting, complete all as specified and directed. |
| 88 | Supply & fix in repair single pole and neutral DB wall mounting type, 240 Volts,8 Way with 200 Amps rated bus bar,double door suitable for fixing MCB's including connecting etc and taking down old unserviceable DB, main switch, complete all as specified and directed. |
| 89 | Supply & fix in repair MCB SPN 6 Amps to 40 Amps 240 volts, complete all as specified and directed. |
| 90 | Supply & fix in repair MCB SP 6 to 40 Amps 240 volts, complete all as specified and directed. |
| 91 | Supply & fix in repair LED building security light fitting 35W new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having seperate driver compartment with IP65 protection and impact resistance of IK07 including mounting bracket of suitable size, complete all as specified and directed. |
| 92 | Supply & fix in repair LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size incl taking down old unserviceable fittings, complete all as specified and directed. |
| 93 | Taking down fan, sealing cable end, dismantling blades and removing fan and blades to stores, complete all as specified and directed. |
| 94 | M & L painting of ceiling fans complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc, complete all as specified and directed. |
| 95 | Hanging only ceiling fans (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and directed. |
| 96 | Supply & fix in repair exhaust fan made of steel body, 300 mm sweep, 230V, AC 50 Hz, copper winding, with blades frame and louvers and mounting accessories, complete all as specified and directed. |
| 97 | Supply & fix in repair exhaust fan made of steel body , 380 mm sweep, 230V, AC 50 Hz, copper winding, with blades frame and louvers and mounting accessories, complete all as specified and directed. |
| 98 | SCHEDULE OF CREDITNote :- Amount of Rs.1,17,081.00 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender