Tender For Repair/Maint Of Path Lights, Garden Lights, Gate Lights And High Mast Lights Installed At Tech And Domestic Area And Repair/Maintenance Of Power Factor Correction Panel, Amf Panels,Electric Chimneys And Misc E/M Works At Installation At Af
Tender Overview
Project Description
Tender for Repair/Maint Of Path Lights, Garden Lights, Gate Lights And High Mast Lights Installed At Tech And Domestic Area And Repair/Maintenance Of Power Factor Correction Panel, Amf Panels,Electric Chimneys And Misc E/M Works At Installation At Afs Yelahanka.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil all as specified and directed. |
| 2 | Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, levelling, watering and well ramming in layers complete all as specified and directed. |
| 3 | Returning filling in excavated soil with left over normal excavated soil including spreading, levelling, watering and well ramming in layers complete all as specified and directed. |
| 4 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed. |
| 5 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 flat, size 250 mm x 150 mm x 40 mm all as specified and directed. |
| 6 | M&L for Plain Cement Concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) in foundation complete all directed. |
| 7 | M&L for Plain Cement Concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) for stay and coping for poles including necessary form work to exposed surface finished smooth and even complete all as specified and directed. |
| 8 | Supply and laying in trenches, LT underground cable, XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross sectional area 6 Sqmm, 2 core multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all directed. |
| 9 | All same as per item No 8 here-in-before but cross-sectional area 10 Sqmm, 4 Core. |
| 10 | All same as per item No 8 here-in-before but cross-sectional area 16 Sqmm, 4 Core. |
| 11 | All same as per item No 8 here-in-before but cross sectional area 25 Sqmm, 3.5 Core.Note : For Ser No 8 to 10, necessary excavation shall be measured and paid under respective items of the same schedule separately. |
| 12 | Supply and fix in repair LED street light fitting 35-Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed. |
| 13 | All same as per item No 12 here-in-before but capacity 60 Watt. |
| 14 | All same as per item No 12 here-in-before but capacity 70 Watt. |
| 15 | All same as per item No 12 here-in-before but capacity 90 Watt. |
| 16 | Supply and fix in repair energy saving rectangular LED flood light fitting 150 Watts, 240 volts AC, cool white colour, CCT 5700°K, CRI>70, THD<10%, system lumens not less than 100 lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, aluminium die cast housing, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing on High mast pole/Buildings/TARMAC poles etc. by means of clamps, nuts, bolts and any other accessories complete all as specified and directed |
| 17 | All same as per item No 16 here-in-before but capacity 200 Watts. |
| 18 | All same as per item No 16 here-in-before but capacity 250 Watts. |
| 19 | All same as per item No 16 here-in-before but capacity 100 Watts. |
| 20 | All same as per item No 16 here-in-before but capacity 70 Watts. |
| 21 | Supply and fix in repair energy saving rectangular LED flood light fitting 50 Watts, 240 volts AC, Colour changing light (RGB) controlled by smart application facility of OEM , CCT 5700°K, CRI>70, THD<10%, system lumens not less than 100 lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, aluminium die cast housing, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing by means of clamps, nuts, bolts and any other accessories complete all as specified and directed |
| 22 | Repair and maintenance of all type Street/Security light fittings 45/60/70/90 watt capacity and flood light fittings 150/170/200/250 watt, solar street light fittings 10/12 watt capacity including cleaning of perplex cover where ever required and tightening of loose connection or brought it down for repair and fix it back after repair on the same pole/place complete all as specified and directed. |
| 23 | Supply and fix in repair of terminal box made out of made up of FRP/ Polycarbonate and locking arrangements of size 200 x 140 x 95 mm Including, Backlite 4 way connector, M S Clamps suitable for pole, PCC/MS/GI/rail etc. with bolt, nut and washer, electrical connections including MCB SP 6-32 Amps complete all as specified and directed. |
| 24 | S&F in repair pole mounted junction box (Street light box) made up of FRP/ Polycarbonate with sliding type doors fits to base by 3 phase busbar insulator - 04 Nos for street lighting system with nuts and bolts with fixing arrangement outdoor type of dimension 240 x 130 x 110 mm for with suitable screen printed skull and bones for danger notice on middle and top cover of the box complete all directed. |
| 25 | Supply and fix in repair three single core PVC insulated and sheathed copper conductor cable 2.5 Sqmm nominal size and one single core PVC insulated and sheathed copper conductor cable 2.5 Sqmm nominal size for earth continuity from main lines to the street light fittings after removing unserviceable one complete all as specified and directed. |
| 26 | Supply and fix in repair three core PVC cable, FRLS with copper conductor round cable 1.5 Sqmm for connection from junction box to street light fittings complete all as specified and directed. |
| 27 | Supply and fix in repair 415 V 10 KA 'B' curve miniature circuit breaker (MCB) of 40 to 100 Amps rating triple pole and neutral in the DB complete with connection testing and commissioning all as specified and directed |
| 28 | Supply and fixing in repair 230 V 10KA 'B' curve miniature circuit breaker (MCB) of 6 to 32 Amps rating single pole in the Junction box/DB complete with connection testing and commissioning all as specified and directed |
| 29 | M&L for boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 75mm dia suitable for 0.4 mpa working pressure complete all as directed. |
| 30 | Supply & lay GI tubing light grade 50 mm bore intrenches/fixing on pole/wall/crossing in drain etc. for protection of UG cable complete all directed. |
| 31 | Supply & lay GI tubing light grade 40 mm bore intrenches/fixing on pole/wall/crossing in drain etc. for protection of UG cable complete all directed. |
| 32 | Supply and fix in repair driver suitable for 45-Watt LED light fittings and testing complete all as specified and directed. |
| 33 | Supply and fix in repair driver suitable for 60-Watt LED light fittings and testing complete all as specified and directed. |
| 34 | Supply and fix in repair driver suitable for 70/72-Watt LED light fittings and testing complete all as specified and directed |
| 35 | Supply and fix in repair driver suitable for 90-Watt LED light fittings and testing complete all as specified and directed. |
| 36 | Supply and fix in repair driver suitable for 150-Watt LED flood light fittings and testing complete all as specified and directed. |
| 37 | Supply and fix in repair driver suitable for 200/250-Watt LED flood light fittings and testing complete all as specified and directed. |
| 38 | Supply and fix in repair LED Aviation light luminaries Integral LED aviation light 12 W comprising of aluminium housing with polycarbonate enclosure complete all as specified and directed |
| 39 | Supply and fix LED Decorative multicolour light DIY Spike light of capacity 5 Watt , IP66 , 240 V , suitable for mounting on the ground as well as wall , offering enhanced aesthetic design possibilities and with momentary switch can be set at multiple colours as per requirement, The heat sink is made up of high pressure die cast aluminium suitable to mount on ground (with spike) and on wall (without spike) , a monomentary switch made up of SS 304 having IP67 is provided offered with system lumen efficacy of 300 lm/ watt at Correlated Colour Temperature (CCT) of colour white / warm white , ANSI Tolerance , colour temp rendering index (CRI) > 70 and L70 rated lifetime of 35000 hours , electrical class I. AC power factor > 0.95, offered with BIS certified potted driver having internal surge protection of 4KV the luminaire shall emit colour in cyclic rotation (red, blue, orange , yellow , pink, cool white and then warm white) dimensions of fixture shall be minimum 310 x 88.6 x 70mm. Make : Orient / Havells/ Halonix/ Crompton. Please Enable Macros to View BoQ information |
| 40 | Supply and fix LED Decorative multicolour light DIY Spike light of capacity 5 Watt , IP66 , 240 V , suitable for mounting on the ground as well as wall , offering enhanced aesthetic design possibilities and with momentary switch can be set at multiple colours as per requirement, The heat sink is made up of high pressure die cast aluminium suitable to mount on ground (with spike) and on wall (without spike) , a monomentary switch made up of SS 304 having IP67 is provided offered with system lumen efficacy of 300 lm/ watt at Correlated Colour Temperature (CCT) of colour white / warm white , ANSI Tolerance , colour temp rendering index (CRI) > 70 and L70 rated lifetime of 35000 hours , electrical class I. AC power factor > 0.95, offered with BIS certified potted driver having internal surge protection of 4KV the luminaire shall emit colour in cyclic rotation (red, blue, orange , yellow , pink, cool white and then warm white) dimensions of fixture shall be minimum 310 x 88.6 x 70mm. Make : Orient / Havells/ Halonix/ Crompton. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender