Tender For Repairs To Boundary Wall, Hard Standing, Storm Drain, Kerb Stone, Parking Sheet And Other Misc Works In Aor Of Age B/R (West) Under Ge (West) Colaba, Mumbai.
Tender Value
1.50 Crore
Estimated cost
Bid Submission
24 Oct 2026
20 days left
EMD
2.25 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs To Boundary Wall, Hard Standing, Storm Drain, Kerb Stone, Parking Sheet And Other Misc Works In Aor Of Age B/R (West) Under Ge (West) Colaba, Mumbai.
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brickwork or stone/ boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework complete all as specified and as directed by Engr-in-charge. |
| 2 | Material and Labour for Brick work with sub class 'B' brick straight or curved on plan exc 6 mtr mean raddius built in CM 1:6 complete all as specified and directed. |
| 3 | All as per item No-2 mentioned here in above but except bricks. (Serviceable bricks obtained from Item No- 01 above to be reused.) |
| 4 | M&L for precast cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in block masonry with solid blocks exceeding 10cm width and setting in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge. |
| 5 | Material and labour for providing cement concrete type C2 (1:3:6) 40 mm graded aggregate as in surface channels and drains finished even and smooth complete all as specified and directed. |
| 6 | Taking down cement plaster on brick walls/ceiling, including racking out Joints, hacking for key, scrubbing down with water etc. |
| 7 | M&L rendering 15mm thick in 1:4 cement plaster on fair faces of stone masonary surface is to be finished even and smooth (without using extra cement) complete all as specified and directed. Note : WPC will be paid separately |
| 8 | S & F Liquid water proofing compound complete all as specified and directed. |
| 9 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and directed. |
| 10 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in deep for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil all as specified and directed by Engineer-in-Charge. |
| 11 | Returning, filling including spreading leveling watering and well ramming in layers n. exc 25 cm in any type of soil complete all as directed. |
| 12 | Removing excavated soil to outside of MoD land and depositing where directed at a level not exc 1.5 m above the starting point complete all as directed. |
| 13 | Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150 mm bore set in cement mortar including demolition of packing under and hauching against sides of pipes complete all as directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.) |
| 14 | Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 200 mm bore set in cement mortar including demolition of packing under and hauching against sides of pipes complete all as directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.) |
| 15 | Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 450 mm bore set in cement mortar including demolition of packing under and hauching against sides of pipes complete all as directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.) |
| 16 | M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 150mm bore pipe all as specified & directed by Engineer-in-charge. |
| 17 | M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 200mm bore pipe all as specified and directed by Engineer-in-charge. |
| 18 | M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 450mm bore pipe all as specified and directed by Engineer-in-charge. |
| 19 | M&L for 150mm bore reinforced concrete pipes, class NP-2 (ISI marked) with collars, laid in trenches and jointed complete all as specified and directed by Engineer-in-charge. |
| 20 | M&L for 200mm bore reinforced concrete pipes, class NP-2 (ISI marked) with collars, laid in trenches and jointed complete all as specified and directed by Engineer-in-charge. |
| 21 | M&L for 450mm bore reinforced concrete pipes, class NP-2 (ISI marked) with collars, laid in trenches and jointed complete all as specified and directed by Engineer-in-charge. |
| 22 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition of any description and in any position not otherwise specifically provided for incl removing debris from MoD land complete all as specified and directed. |
| 23 | M&L for RCC (Nominal mix ) 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete |
| 24 | M&L for Mild steel bars TMT 8mm dia in stirrups, spacers and binders and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to complete all as directed. |
| 25 | M&L for Mild steel bars TMT 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to complete all as directed. |
| 26 | M & L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter fair finished surface complete all as specified and as directed. |
| 27 | M & L for formwork to soffits of suspended slabs such as roof slabs,, floor slabs, landings , and similar work; not exceeding 200mm thick fair finished surface complete all as specified and as directed. |
| 28 | S&F in repairs of heavy duty cast iron manhole cover including frame of suitable size all as specified and as directed. |
| 29 | S & F in repairs 900mm x 600mm FRP manhole cover of 10 ton loading capacity with frame over manhole coping concrete complete all as specified and directed. |
| 30 | S&F factory made SFRC (Steel Fibre Reinforced Concrete) drain cover of size 900 x 600 x 75 frame dimention 800 x 1100x100 mm and fixed to drain in CM (1:4) complete all as specified and directed. |
| 31 | Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground level). |
| 32 | M&L 75 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate (using 40mm graded stone aggregate) in sub base of flooring. |
| 33 | M&L for M&L 25 mm thick Cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) in hard standing complete all as specified and directed by Engineer-in-charge. |
| 34 | M&L for PCC 75mm thick type B1 1:2:4 (20 mm graded stone aggregate) laid in alternative as in plinth protection including finished the surface even and fair without using extra cement |
| 35 | M & L for glazed / matt finish chequred cement concrete coloured tiles of area exc 0.04 Sqm but not exc 0.09 Sqm and 25 mm thick, set, jointed and pointed in neat cement slurry (with grey cement and pigment) after and including 20 mm thick in cement plaster in CM (1:6) for fixing tiles complete all as directed. |
| 36 | M&L for any coloured digital ultra strong / heavy duty outdoor anti skid vitrified tiles 14-16 mm thick (Square / Rectangular) polished area of each tile exc 0.09 Sqm and not exc 0.36 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles and including 20 mm thick in cement plaster in CM (1:4) for fixing tiles complete incl dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises all as directed and specified. |
| 37 | M & L for outdoor Elevation glazed / matt finish Ceramic tiles area of each tile exc 0.09 Sqm and not exc 0.36 sqm, in wall 7-10 mm thick (square/ rectangular) set and jointed in neat cement slurry including 10 mm backing coat in CM (1:4) and pointed in white coloured cement etc. complete incl dismantling wall tiling including cement backing coat removing and rubbish off the premises all as directed and specified. |
| 38 | M&L Machine pressed precast concrete rubber moulded interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushioning complete all as specified and directed by Engineer-in-charge. Note :- (i) Pattern of interlocking tile to be rubber moulded or equivalent as approved by GE. (ii) Rate quoted by the contractor shall deemed inclusive of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) packing and finished even and fair to the sides of pavement. |
| 39 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 40 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar |
| 41 | M & L 20mm thick Granite (of any type) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed. |
| 42 | M & L 20mm thick Granite Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to matchwith shade of granite complete all as specified and direceted all as specified and directed. |
| 43 | Material and labour for precast cement concrete louvers and jallies 40 mm thick, fixed over boundary walls using two Nos vertical members of size 100 x 90 x 800 mm height and one Nos member surmounted over vertical members of jalli (like ropes of the same materials) including all moulding and including demolition of old Trellis work (Jafri), including taking as under of battens in trellis (posts and rails measured separately) all as directed by Engr in charge. |
| 44 | S & F in repairs of RCC M30 Grade approved Design Precast concrete post of size 150mm x 150mm x 2100 mm height , having two grooves of size 55 x 28 mm so as to receive 7 Nos of panels having size of 1500 mm x 300 mm x 50 mm thickness ( 2 Panel at Top and bottom + 4 Design Panel bottom to top +1 Jafari type panel at top as approved by Engr-in Charge/GE). The post shall be reinforced with 4 Nos of 8 mm dia bars with 4 mm dia stirrups @ 150 mm C/C, panels shall be reinforced with 4 Nos of longitudinal bars of 6mm dia plain steel and 6mm plain MS Stirrups @ 150 C/C all welded. The post shall be fixed to the ground by digging a hole of 300mm x 300mm x 600 mm and filled with PCC 1:3:6 after the post should be aligned in these holes, including removal of excavated earthwork outside MoD land. The post will be erected @1.615m C/C. Height of the pillar shall be 2700mm (600mm below the ground and 2100 mm above the GL) with any approved design by Engr-In-Charge complete all as specified and directed . |
| 45 | Dismantling wrought iron or mild steel work of any description specifically provided for gates, railings, framed truss or any other misc work etc complete all as specified and directed. |
| 46 | S & F in repair for Steel work in tubular trusses including bending and cutting special shaped by machine washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 47 | S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 48 | S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed. |
| 49 | S&F for ornamental and intricate design Framed work such as doors with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 50 | S & F MS plate (CHEQUERED) 5mm and over as in manhole cover fixed to angle iron frame with three Nos of hinges and 150 mm handle complete all as specified and directed. |
| 51 | S&F Pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet/ semi corrugated 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws including dismantling (AC corrugated , semi corrugated/ PPGI sheets in roof coverings complete all as specified and directed by Engineer in charge. |
| 52 | S&F Pre painted Galvalume aluminium zinc coating GI based Plain steel sheet/ semi corrugated 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws including dismantling (AC corrugated , semi corrugated/ PPGI sheets in roof coverings complete all as specified and directed by Engineer in charge. |
| 53 | M&L for Preparation of new steel surfaces of any description over 10cm width or girth and application of two coats of synthetic enamel paint over one coat of red oxide primer etc, complete all as specified and directed. |
| 54 | M&L for 06-10 mm thick stone cladding gang saw cut with machine cut edges, uniform colour of each stone size not exceeding 0.25 sqm fixed with andetc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over and including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete incliding dismantling of the old stone cladding all as specified and directed by Engineer in charge. |
| 55 | S&F in repair Aluminium anodised frame for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc complete all as specified. |
| 56 | S & F In repairs of 3mm thick panel of any type, pattern and shape Aluminium Composite Panel (ACP), aluminium thickness of 0.5mm, Front side finish of aluminum roll coated with Plain / coloured / wooden texture PE / PVDF, Core material of Non-toxic polyethylene, Macromolecular lamination film, Rear side of Aluminum coated with primer and including frame work using of Fasteners, including concealed screws, nuts, bolts and other items required for connecting aluminium to aluminium / steel / wooden / ply board, Blind rivets all fixing anchors, brackets and similar attachments used in the erections, shall be of aluminium, non-magnetic stainless steel, zinc coated steel, for fixing in both internal / external wall cladding complete weather proofing sealant of a polyurethane elastic joint / structural silicone sealant / pre-formed gaskets to the Horizontal and Vertical Joints in the Aluminium cladding / facade as per manufacturer's instructions complete all as specified and directed. Note : 1. The unit rate quoted is deemed to be inclusive of all necessary fixing accessories mentioned in the description of work and scaffolding works at any height for installation. 2. For payment purpose panels areas will be measured on one side only. |
| 57 | S & F in repairs of SS 304 Grade metal letters of height 200mm with PU paint to match the logo colors, mirror polish finish, anti rust and including necessary arrangements to fixing in walls, using scaffolding at any height complete all as specified and directed. |
| 58 | Material & Labour in repairs for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement for Stainless Steel grade 304 decorative designer railings, staircase, covers, sitting place, shed etc including taking down of old railing complete. (design and pattern as approved) made out o complete all as directed by Engineer-in-Charge Make : Jindal stainless Ltd., SAIL, TISCO, POSCO etc. |
| 59 | M & L for preparing old surfaces of walls by scrapping / rubbing and applying one coats of weather proof acrylic exterior paint (100% Acrylic) Base coat of Apex ultima protek duralife and top coat of Apex Ultima protek, Make : Asian Paints) over a coat of alkali resistent primer through authorized applicator only including use of scaffoldings from Ground floor upto 06 storeys bldgs complete all as specified and directed. Make: Asian Paints / Berger Paints / Nerolac / Shalimar paints as approved by GE complete all as specified and directed. |
| 60 | M&L preparing old painted brick or conc surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of floor coat emulsion paint complete all as specified and directed. Make : INDIGO / Equivalent |
| 61 | S&F in repairs 75mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls or laid in floors etc complete. |
| 62 | S&F in repairs PVC (SWR) bends 75 mm dia any radius with access door all as specified and directed |
| 63 | S&F in repair 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified. |
| 64 | S&F in repair 110 mm bore PVC (SWR) bends/shoes any radius complete all as specified. |
| 65 | Supply & Fixing PVC coated chain link fencing wire gauge 4mm and wire thickness 4 mm including line wires, and mesh size type of stadards, rail straining bolts etc size of mess 50x 50 mm including dismantling complete all as specified and directed. |
| 66 | S&F PVC tensile fabric structure with PVDF (polyvinyl-idene-fluoride) coating with all necessary fixtures, of any size and shape for making canopies, shed fixed with mild steel structural frame work, weight of the fabric is considered, with fabrics ranging from 600 gsm to 900 gsm all as specified and directed. Note : (a) The shape/ design of the sheds will be as approved by GE. (b) Cost of structural steel used will be measured and paid separetly under relevant items in this schedule. Make:Mehler Texnologies (Germany) – The \\"Valmex\\" Brand / Serge Ferrari or equivalent as approved by GE. |
| 67 | Dismantling/Demolition of existing roof terracing of cement/brick concrete(un-reinforced) and existing water proofing treatment of any thickness in any position on top of roof of building, cleaning surface of roof with brush/mechanical brush and with water throughly to romove all dust/dirt and loose particles to expose bare concrete roof slab and romoval of rubbish/demolished material out side MD land complete all as specified Note : Demolition should be done by chiselling. |
| 68 | M&L for PCC (1:2:4) Bo using 12.5 mm graded stone aggregate as in levelling padding course over RCC roof surface including rounded or chamferred on edges etc., with approved water proofing compound all as per manufacturer's instructuions on the roof surface to achieve requisite slope all as specified and directed. (Note :- Supply only water proofing compound shall be measured and paid separately). |
| 69 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified(a) Cleaning existing surface properly. (b) Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density of 0.87 -0.89 Kg/Lit at 25 Degree Centigrade on the prepared dry roof surface. (c) Providing and Laying APP modified water proofing membrane reinforced with non wooven polyster matt with physical propertities as under :-(i) Membrane weight >3.6 Kg/Sqm .(ii) Net wooven polyster weight >160 gm/Sqm(iii) Softening point of membrane > 150o C(iv) Joint Tensile strength Longitudiual > 650 Sq Cm at 230o C & Transverse > 450/ Sq cm (v) Tear strength - Longitudual > 300 N & Transverse > 250 N Direction(vi) Elongation > 30 %(vii) Impermeability under water pressure > 3 Kg/Sq cm Note:- APP membrane shall be laid using butane torch by Torch application with minimum 10 cm side overlap and 15 cm end lap. The laying of membrane shall be got done through authorised applicator of manufacturer of membrane.(d) Over the membrance provide a finishing with solar reflective bituminous aluminium paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane |
| 70 | S&F LED building security light fitting 45 Watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency minimum 100 luman per watt after all losses, pressure die-cast aluminium housing LED Street light complete with GI clamp including connected accessories and bracket made of GI pipe 50mm dia light grade 1.25 m long, bend to shape with two sets of MS flat iron clamps, nuts, bolts, washers all as directed by Engineer-in-Charge.Make Havells/ Crompton/ Bajaj. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 71 | S&F LED building security light fitting 60 Watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency minimum 100 luman per watt after all losses, pressure die-cast aluminium housing LED Street light complete with GI clamp including connected accessories and bracket made of GI Pipe 50mm dia light grade 1.25 m long, bend to shape with two sets of MS flat iron clamps, nuts, bolts, washers all as directed by Engineer-in-Charge.Make Havells/ Crompton/ Bajaj. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 72 | S&F LED intelligent smart sensor based auto dimmable LED building security light fittings with brightening / dimming options of 30 % to 100 % of the rated wattage on sensing of movement / occupancy, with in 8 meter radius fitting of capacity 45 watt, luminaire fixture in IP 66 protection level with aluminum pressure die cast reflector with heat shrink LM 6, dedicated optics with precise light distribution SDMC not less than 5 uniform lighting quality and UV stabilized, output of LED lamp efficiency 120 luman per watt after all losses, protection against biological eye safety certification and UV, and including suitable bracket MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers all as specified and directed.Make Havells/ Crompton/ Bajaj.Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 73 | S&F LED intelligent smart sensor based auto dimmable LED building security light fittings with brightening / dimming options of 30 % to 100 % of the rated wattage on sensing of movement / occupancy, within 8 meter radius fitting of capacity 60 watt, luminaire fixture in IP 66 protection level with aluminum pressure die cast reflector with heat shrink LM 6, dedicated optics with precise light distribution SDMC not less than 5 uniform lighting quality and UV stabilized, output of LED lamp efficiency 120 luman per watt after all losses, protection against biological eye safety certification and UV, and including suitable bracket MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers all as specified and directed.Make Havells/ Crompton/ Bajaj.Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 74 | Supply and fixing Solar street/ Bldg Security light 40 watt with 3 meter pole sensor based auto dimmable LED street lights warm / warm white fitting with built in Dynamic Power Saving Device - DPSD that automatically switches off to 50% of the rated wattage on pre-set time interval of capacity 45 watt, luminaire fixture in IP 66 protection level with aluminum pressure die cast reflector with heat shrink LM 6, dedicated optics with precise light distribution SDMC not less than 5 uniform lighting quality and UV stabilized, output of LED lamp efficiency 100 luman per watt after all losses, protection against biological eye safety certification and UV, and including suitable bracket MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers, warm / warm white and including suitable bracket MS clamps, complete all as specified and directed.Make Havells/ Crompton/ Bajaj. |
| 75 | Supply and fix LED street light fitting of capacity 90 watt, luminaire fixture in IP 66 protection level with aluminum pressure die cast reflector with heat shrink LM 6, dedicated optics with precise light distribution SDMC not less than 5 uniform lighting quality and UV stabilized, output of LED lamp efficiency 100 luman per watt after all losses, protection against biological eye safety certification and UV, and including suitable bracket MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers all as specified and directed. Make Havells/ Crompton/ Bajaj. Note: Contractor should arrange all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 76 | Supply and fix LED flood light fitting of capacity 200 watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency 100 luman per watt after all losses, driver with 4KV surge high and low voltage protection, power factor not less than 0.97, life of LED 50,000 burning hours at L 70, protection against biological eye safety certification and UV and including suitable bracket and fixed to pole/ wall with two Nos. MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers etc. of 6000k/3000k as per requirment on site all s specified and directed.Make Havells/ Crompton/ Bajaj. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 77 | Supply and fix LED flood light fitting of capacity 150 watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency 100 luman per watt after all losses, driver with 4KV surge high and low voltage protection, power factor not less than 0.97, life of LED 50,000 burning hours at L 70, protection against biological eye safety certification and UV and including suitable bracket and fixed to pole/ wall with two Nos. MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers etc. of 6000k/3000k as per requirment on site all s specified and directed. Make Havells/ Crompton/ Bajaj. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 78 | Supply and fix LED flood light fitting of capacity 100 watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency 100 luman per watt after all losses, driver with 4KV surge high and low voltage protection, power factor not less than 0.97, life of LED 50,000 burning hours at L 70, protection against biological eye safety certification and UV and including suitable bracket and fixed to pole/ wall with two Nos. MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers etc. of 6000k/3000k as per requirment on site all s specified and directed .Make Havells/ Crompton/ Bajaj. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 79 | Supply and fix LED flood light fitting of capacity 50 watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency 100 luman per watt after all losses, driver with 4KV surge high and low voltage protection, power factor not less than 0.97, life of LED 50,000 burning hours at L 70, protection against biological eye safety certification and UV and including suitable bracket and fixed to pole/ wall with two Nos. MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers etc. of 6000k/3000k as per requirment on site all s specified and directed. Make Havells/ Crompton/ Bajaj. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 80 | Taking down old unserviceable building security light/ street light/ flood light fitting of any type and any capacity and remove from its location all as specified and directed. |
| 81 | Supply and fixing in repairs LED inverter Batten 18 watt works warm / warm white on AC supply in normal mode and DC supply in inverter mode with inbuilt battery back up of upto 4 hours, high efficilceeiny, high lumes output, including taking out old fittings, complete all as specified and directed. |
| 82 | M&L for point wiring (concealed type) with 1.5 sq mm, PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including rigid non-metallic PVC heavy duty conduit (ISI mark), 19/ 20 mm dia suitable size including cutting chases for conduits, sinking for boxes for concealed conduit wiring with all fittings and accessories including with and fix concealed 1.2 mm thick pressed steel sunken box along with cover plate and frame, suitable for fixing moduler switch/ socket and unsheathed (FRLSH) single core multi-stranded copper conductor cable of size 1.5 sqmm green in colour as earth continuity conductor connected to common earth dolly and making good to the disturbed surfaces to match the existing surfaces complete (fill up cement in gaps, finishing with putti and apply two coats of paint, match with existing colour in disturbed surface area), as per IS specification and as specified in SSR Part-I complete for one light point / bell point/ Ex Fan point / wall fan point controlled by one modular switch, 1 way 6/10 amps, 1 module. Make of Cable : Anchor / Havells / Finolex / Polycab Make of Conduit : Precision/ Prestoplast/ Polycab |
| 83 | M&L for point wiring with PVC insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLSH, passing through PVC casing caping including modular PVC Gang box of suitable module for mounting of modular Switches & Sockets as required at site along with one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) FRLSH as earth wire connected to earth dolly all as specified & as directed by engr-in-charge for one light/ Exhaust fan/ Wall Fan point controlled by one switch Make of Cable : Anchor / Havells / Finolex / Polycab Make of Conduit : Precision/ Prestoplast/ Polycab |
| 84 | Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete encluding all fittings and fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings, etc. and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed. |
| 85 | S&F in repairs ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified. Make : Cona , Plaza, Anchor . |
| 86 | S&F in repairs Moduler Switch single pole, one way 6/10 Amp with all fittings and accessories including with and fix concealed 1.2 mm thick pressed steel sunken box along with cover plate and frame all as specified and directed. |
| 87 | S&F in repairs sheet metal enclosures double door, for DBs when MCBs to be used 240 volts 8 way with 200 Amps rated bus bar for single pole and neutral fixed on wall by cutting chasing and making good to the disturbed surfaced board in and including copper lugs/thimbles duly crimped for connection all as specified and directed. Make : Havells / Legrand / Schneider / Indo Asian |
| 88 | S&F in repairs sheet metal enclosures double door, for DBs when MCBs to be used 240 volts 12 way with 200 Amps rated bus bar single pole and neutral fixed on wall by cutting chasing and making good to the disturbed surfaced board in and including copper lugs/thimbles duly crimped for connection all as specified and directed. Make : Havells / Legrand / Schneider / Indo Asian |
| 89 | S&F in repairs MCB SP 240 volt, 8 to 40 Amps, C series all as specified and directed. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. |
| 90 | S&F in repairs MCB SPN 240 volt, 40 to 63 Amps, C series all as specified and directed. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. |
| 91 | Supply and lay cable insulated screened PVC bedded, unarmoured, sheathed, electric power cables 1100 volts grade with stranded copper conductor of size 1.5 Sqmm X 3 core for connecting up to post top lantern, garden light and looping box all as specified and directed . |
| 92 | Supply and lay cable insulated screened PVC bedded, unarmoured, sheathed, electric power cables 1100 volts grade with stranded copper conductor of size 2.5 Sqmm X 3 core for connecting up to post top lantern, garden light and looping box all as specified and directed . |
| 93 | Taking down old UNSV burnt cable 1.5 sqmm to 6 sqmm size all as directed . |
| 94 | Supply and fix for decorative pole antiquely designed aesthetically appealing landscape cum street light (3.0 metres long) along with single arm hanging braket of suitable size made out from ERW pipe with base plate, finial taper plug, bolts, nuts, screws and top cover, suitable for fixing one Nos hanging light and testing all as specified and directed. |
| 95 | Supply and fix for octagonal pole antiquely designed aesthetically appealing landscape cum street light made out from hot deep galvanised (7.00 metres long) along with double arm bracket of suitable size made out from galvenised pipe complete with base plate having holes for mounting on foundation finial taper plug, bolts, nuts, screws and top cover, suitable for fixing street light and testing all as specified and directed. |
| 96 | Taking down old broken unserviceable, damaged/rusted swaged steel tublar poles/ cement poles of any size and remove from site all as specified and directed. |
| 97 | M&L PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) for making foundation of poles and pillars for gate light fixing all as specified and directed. |
| 98 | M&L PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) for making coping of Street light poles all as specified and directed. |
| 99 | S&F LED Hanging light Aluminium housing polymer defuser and pleasant lumin output IP -65 of capacity 40 watt LED 0f 6000k/3000k as per requirment on site including neccesary brakets made out from GI pipe of suitable size and shape complete testing on ground all as specified and directed. |
| 100 | S&F LED Post top lantern fitting of capacity 25 watts, 100 lumen per watt capacity of 6000k/3000k as per requirment on site including GI Pipe in wall and all necessary fixing arrangement all as specified and directed. |
| 101 | S&F for LED Post top gate light fitting of capacity 50 watts, 100 lumen per watt capacity 0f 6000k/3000k as per requirment on site including GI Pipe in wall and all necessary fixing arrangement all as specified and directed. |
| 102 | S&F LED Post top lantern heritage light fitting of capacity 20 watts, 100 lumen per watt IP 65 of 6000k/3000k as per requirment on site including GI Pipe in wall and all necessary fixing arrangement all as specified and directed. |
| 103 | S&F LED BOLLARD mushroom type light fitting of capacity 9 watts, 100 lumen per watt IP 65 0f 6000k/3000k as per requirment on site including necessary fixing arrangement all as specified and directed. |
| 104 | S&F LED BOLLARD camper type light fitting of capacity 9 watts, 100 lumen per watt IP 65 0f 6000k/3000k as per requirment on site including necessary fixing arrangement all as specified and directed. |
| 105 | S&F LED spot decorative spike light fitting of capacity 9/10 watts, IP 65 0f 6000k/3000k as per requirment on site including necessary fixing arrangement all as specified and directed. |
| 106 | Supply and fix 6 watt fountain light, IP-66, in warm white colour, of 6000k/3000k as per requirement on site of 6000k/3000k as per requirment on site all as specified and directed. |
| 107 | Supply and fix 9 watt wall light, IP-66, in warm white colour, of 6000k/3000k as per requirement on site of 6000k/3000k as per requirment on site all as specified and directed. |
| 108 | Taking down old unserviceable post top lantern, decorative outdoor fitting of any capacity and any type and remove from its location all as specified and directed. |
| 109 | Supply and fix LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly , IS-7098 Part-II, with stranded aluminum conductor LT 1100 volts grade of size 35 Sqmm X 4 core with lugs and ferruls of suitable size all as specified and directed. |
| 110 | Supply and fix LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly , IS-7098 Part-II, with stranded aluminum conductor LT 1100 volts grade of size 25 Sqmm X 4 core with lugs and ferruls of suitable size all as specified and directed. |
| 111 | Supply and fix LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly , IS-7098 Part-II, with stranded aluminum conductor LT 1100 volts grade of size 16 Sqmm X 4 core with lugs and ferruls of suitable size all as specified and directed. |
| 112 | Supply and fix LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly, IS-7098 Part-II, with stranded aluminum conductor LT 1100 volts grade of size 10 Sqmm X 4 core with lugs and ferruls of suitable size all as specified and directed. |
| 113 | Supply and fix cable LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly, IS-7098 Part-II, with stranded aluminum conductor LT 1100 volts grade of size 10 Sqmm X 2 core with lugs and ferruls of suitable size all as specified and directed. |
| 114 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 4 sq. mm X 2 Core in service connections all as specified and as directed. |
| 115 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 6 sq. mm X 2 Core in service connections all as specified and as directed. |
| 116 | Taking down and up old unsereviceable XLPE underground cable of any size from pole wall/roof/trenches all as specified and directed. |
| 117 | Labour only for taking out and checking of underground cable and relaying /rerouting the same cable of any size and any capacity including making servicable electric connections all as specified and directed. |
| 118 | Material and labour GI tubing 50 mm dia light grade galvanized for cable protection and fixing of post top lantern with all connecting items (like suitable size of clamps, angle, nut & bolts) for holding of pipe with pole all as specified and directed. |
| 119 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in hard/dense soil/RCC/PCC for laying of cable/ GI pipe all as specified and directed. |
| 120 | Supply and providing sand/stone dust for sand cushioning for cable protection or filling in trenches of sand in cable ducts after cleaning of ducts all as directed and specified Note:. for the purpose of payment punned thickness will be measured. |
| 121 | Supply and laying Double Wall Corrugated (DWC) High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 40mm dia for laying of cable protection complete to walls/ trenches/floor/ceilings, complete all as specified and directed by Engineer-in-Charge. |
| 122 | Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25cm thick each layer all as specified and directed. |
| 123 | Removing surplus soil to a distance outside MD land and depositing n exc. 50m where directed at a level not exceeding 1.5m above the starting point all in including removing balance debries from MD land all as specified and directed. |
| 124 | M&L cement concrete 1:2:4 type B1 using 20mm graded aggregate in width for Feeder panel foundation/road filling including including rafts, footings, foundation beams plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 125 | S&F GI clamp including connected accessories and bracket made of GI Pipe 50mm dia light grade 1.25 m long, bend to shape with two sets of MS flat iron clamps, nuts, bolts, washers etc including two coats of synthetic enamel paint over a coat of red-oxide primer all as directed and specified. |
| 126 | S&F street light single arm bracket made out of GI pipe 40 mm bore light grade 1.50 metre long bend to shape including welding etc and two sets of clamps made out of MS 40mm x 5mm bent to required shape and necessary nut bolt washer, including two coats of synthetic enamel paint over a coat of red-oxide primer all as directed and specified. |
| 127 | S&F street light double arm brackets made out of GI pipe 40 mm bore light grade 1.50 metre long bend to shape including welding etc and two sets of clamps made out of MS 40mm x 5mm bent to required shape and necessary nut bolt washer, including two coats of synthetic enamel paint over a coat of red-oxide primer all as directed and specified. |
| 128 | Taking down/out old unserviceable rusted GI pipe light grade street light brackets building security light brackets and remove from its location all as specified and directed. |
| 129 | Taking down/out old unserviceable rusted GI pipe light grade of 50mm/40mm/25 mm bore and remove from its location all as specified and directed. |
| 130 | Supply and fix in repairs looping box made out from fiber of size 300X200X112mm, out door type weather proof with locking arrangement & comprising of three phase connector and MCB SPN 10 Amp, with suitable bus bar arrangements and fix on pole with and including suitable size MS clamps, MS flat iron, cable glands, nut bolts, washers all as specified and directed. |
| 131 | Supply and fix in repairs looping box made out from fiber of size 175X150X100mm, out door type weather proof with locking arrangement & comprising of connector MCB SPN 6 Amp and fix on pole with and including suitable size clamps, MS flat iron, cable glands, nut bolts, washers all as specified and directed. |
| 132 | S&F 12 KW Three Phase street light time switch distribution board with enclosure consisting with 40 Amps 3 pole power contactor and Digital time switch including taking down old unserviceable time switch, complete all as specified and directed. |
| 133 | S&F 6 KW Single Phase street light time switch with distribution board with enclosure consisting with 16 Amps single pole power contactor and DIGITAL time switch including taking down old unserviceable time switch, complete all as specified and directed. |
| 134 | Taking down old unserviceable Single/ Three phase street light time switchof any capacity and remove from its location all as specified and directed. |
| 135 | S&F in repairs steel perforated trunking system of size 180X30 mm and providing sturdy nuts and bolts for connecting cable trunking steadily onto walls or lying in air steadily with help of metal frame. |
| 136 | S&F in repairs PVC trunking system of size 60X30 mm and providing sturdy nuts and bolts for connecting cable as per requirment on site including necessary fixing arrangement all as specified and directed. |
| 137 | S & F for High-intensity micro-prismatic retro-reflective safety tape (50 mm width) engineered for street light poles and hazard identification. Features weather-resistant, waterproof, UV-stabilized construction with a permanent pressure-sensitive adhesive backing for galvanized metal surfaces, complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysOct 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender