Tender For Infrastructure Development Of Industrial Estate In Tripura/ Sh: Power And Electrical - Tsecl Work Etc. At Dhajanagar And Sarasima Industrial Estates (Adb Project/ Package :14)
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Oct 2026
14 days left
EMD
11.27 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gomati → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Infrastructure Development Of Industrial Estate In Tripura/ Sh: Power And Electrical - Tsecl Work Etc. At Dhajanagar And Sarasima Industrial Estates (Adb Project/ Package :14)
BOQ
| Sl. No. | Item Description |
| 1 | LOCATION: Dhajanagar Industrial Estate |
| 2 | Construction of new 33/11 KV S/s with 3.15 MVA Power Transformer and control room building |
| 3 | MS MAIN AND WICKET GATE ON RCC COLUMN |
| 4 | Yard fencing with chain link mesh over RCC beam 2.4 mtr. Height |
| 5 | Boundary wall with RCC column and Brick work |
| 6 | MS SIGN BOARD, BAY INDICATION BOARD & RYB PHASE INDICATION BOARD |
| 7 | Yard Leveling by Kopra filling |
| 8 | Laying of Metal in yard by 100 mm thick metalling with 40 mm size B.T. Yard level to be increased by grouting Brick placed vertical 100 mm above of the ground and remaining part of the brick kept inside the ground |
| 9 | Cable Trench (Length suitable for substation area)Construction work of RCC utility duct i/c excavation, base slab, RCC wall, Top slab, RCC drain * drain cover, from works etc, including reinforcement HYSD bar etc., for laying 2 nos. 33KV, 2 no. 11kv, 2 no. LT underground cable.Item Length Width Depthexcavation L 2.85 1.775PCC (M-15) L 1.85 0.075RCC Base Slab L 1.70 0.150(M-25)RCC wall (M-25) 2xL 0.15 1.400Top Slab1 (M-25) L 1.70 0.150 |
| 10 | 3.15 MVA Transformer |
| 11 | Yard Equipment Base including CT, PT, Isolator, LA etc |
| 12 | Full GI MS Tubular Pole 9 m Long FOR YARD LIGHTENING |
| 13 | LED Flood Lighting 80 Watt |
| 14 | PROVIDING & FIXING PERFORATED CABLE TRAY 300 MM WIDE & 2 MM THICK FIXED ON 45X45X5 MM M.S. ANGLE STAND GROUTED IN C.C 1:24 |
| 15 | PROVIDING AND FIXING EARTH PIT OF BRICK MASSONERY 0.6 X 0.6 M INNER SIZE WITH FLAG STONE COVER FOR WATERING SYSTEM FOR 18 NO EARTH PITS |
| 16 | Costruction of retaining wall 1.5 M high as per site requirement |
| 17 | Earthing of New 33/11 KV s/s (For black cotton soil) (Neutral+Body+Pole+LA)(4 earth=1 Set) using Galvanized mild steel flats (50x6 mm.) for connections, GI pipes 40 mm., (3 mtr. Each pipe), Bentonite powder, along with 3 mtrs.(Galvanized) 25 mm rod (single spike/earth rod distributed for mesh formation) |
| 18 | Earthing of Station Transformer (For Murrum soil)(Neutral+Body+Pole+LA) (4 earth=1 Set) |
| 19 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 20 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.-All kinds of soil |
| 21 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.:-All kinds of soil |
| 22 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 23 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling:-With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 24 | Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. Note : 1) Excess/less cement used than specified in this item is payable/ recoverable separately.All works upto plinth level ::-M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) |
| 25 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 26 | Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply |
| 27 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 28 | Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 29 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. using shuttering ply |
| 30 | Providing and laying in position ready mixed concrete manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of RMC from transit mixer to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per the direction of Engineer-in-Charge. (Note :- Cement content considered in this item is @ 418 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).Reinforced cement concrete grade M-25 using 418 kg of cement per cum.-All works upto plinth level |
| 31 | Providing and laying in position ready mixed concrete manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of RMC from transit mixer to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per the direction of Engineer-in-Charge. (Note :- Cement content considered in this item is @ 418 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).Reinforced cement concrete grade M-25 using 418 kg of cement per cum.-All works upto Floor five level |
| 32 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level..-Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 33 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.:-Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 34 | First class brick work in foundation and plinth including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 35 | First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 36 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 37 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 275mm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters & with handles, hold fast including embedding in cement concrete of required grade required for fixing in position, all necessary fittings, including applying of approved steel primer etc. complete as required:-80x0.90 mm M.S. laths with 0.90 mm thick top cover. |
| 38 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :Sal Wood |
| 39 | Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : |
| 40 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veeners on both faces of shutters.:-35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 41 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured):-Rectangular or square. |
| 42 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 43 | Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :250 x 10 mm |
| 44 | Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :150x10 mm |
| 45 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 46 | Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19×19mm MS square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame . The door frame to be fixed to the wall usuing MS screws of 65/100 mm size complete as per manufacturers' specification and direction of Engineer-In-Charge. |
| 47 | Providing and fixing to existing door frames-30mm thick factory made solid both side prelam panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles, top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture . M.S. frame covered with 5mm thick heat moulded prelam PVC ‘C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, button and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, panelling of 5mm thick both side Prelam PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together |
| 48 | Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete.152x42x18 mm weighing not less than 60 gms. |
| 49 | 12 mm cement plaster of mix:-Cement mortar 1:4 (1 cement : 4 fine sand) |
| 50 | 15 mm cement plaster on the rough side of single or half brick wall of mix:-Cement mortar 1:4 (1 cement : 4 fine sand) |
| 51 | 6 mm cement plaster of mix :-Cement mortar 1:4 (1 cement : 4 fine sand) |
| 52 | Neat cement punning |
| 53 | Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer] |
| 54 | Finishing walls with water proofing cement paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :-New work ( two or more coats applied @ 3.84 kg/10 sqm) |
| 55 | Applying priming coat [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :-With ready mixed Pink or Grey primer of approved brand and manufacture on wood work ( hard & soft wood ). |
| 56 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:-Two or more coats on new work |
| 57 | Providing and laying 1st class quality ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. all complete as per direction of the Engineer in-charge.Mat Finish Tiles/ Anti-skid Tiles/ Glossy Tiles600 mm x 600 mm in all shades and designs 1st class quality ceramic floor Porcelain tiles |
| 58 | Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-incharge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge.450 mm X 300 mm in all shades and design |
| 59 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. all complete as per direction of Engineer-in-charge. |
| 60 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.40 mm nominal outer dia .Pipes. |
| 61 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.20 mm nominal outer dia .Pipes. |
| 62 | 25 mm nominal outer dia .Pipes. |
| 63 | 32 mm nominal outer dia .Pipes. |
| 64 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):25 mm nominal bore |
| 65 | 32 mm nominal bore |
| 66 | 40 mm nominal bore |
| 67 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid. |
| 68 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 69 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 70 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm |
| 71 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe40 mm dia |
| 72 | Providing and fixing toilet paper holder :-C.P. brass |
| 73 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.:-15 mm nominal bore |
| 74 | Providing and Fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern. |
| 75 | Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Single socketed pipe - 75 mm OD |
| 76 | Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Single socketed pipe - 100 mm OD |
| 77 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Single pushfit Coupler75 mm |
| 78 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Single pushfit Coupler110 mm |
| 79 | Single equal tee without door:75x75x75 mm |
| 80 | Single equal tee without door:110x110x110mm |
| 81 | Bend 87.5°:75 mm dia |
| 82 | Bend 87.5°: 110 mm dia |
| 83 | Plain shoe:75 mm dia |
| 84 | Plain shoe:110 mm dia |
| 85 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water, soil, waste & vent pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.75 mm dia |
| 86 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water, soil, waste & vent pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.110 mm dia |
| 87 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors:100 mm inlet and 75 mm outlet.Sand Cast Iron S&S as per IS- 1729. |
| 88 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling and dash fasteners to be paid for separately) :-For fixed portion of approved quality:-Polyester powder coated aluminium ( minimum thickness of polyester powder coating of 50 micron ). |
| 89 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):-Polyester powder coated aluminium ( minimum thickness of polyester powder coating of 50 micron ). |
| 90 | Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :-With float glass panes of 8 mm thickness ( weight not less than 20 kg / sqm ) |
| 91 | 1000 LITER P/F SINTEX OVERHEAD TANK & GI PIPE (WITH LENGTH OF 125 MTRS) FITTING FOR WATER SUPPLY INCLUDING WATER TAP(17 NO.) NEAR TRANSFORMER NEUTRAL EARTHING |
| 92 | PROVIDING AND FIXING 5HP SUBMERSIBLE PUMP |
| 93 | Furniture for control room Table 600mmx 900mm- 1no., Chair- 3no., Computer table 1no. (Godrej or equivalent ) |
| 94 | VRLA Battery Set 110 Volt, 300 AH |
| 95 | Sub station Battery charger 300 AH, 110 Volt |
| 96 | 110 V DC Distribution Boaed |
| 97 | Supply, installation, testing & commissioning of wall mounted A.C. Sub distribution board (ACDB-2), comprising of 200 A MCCB I/C, PIL, 200/5A CT (3 Nos.) A+AS, V+VS, Outgoing- 32A TPN MCB 2 Nos., 63A TPN MCB 2 Nos, 16A SPN MCB 9 Nos. |
| 98 | Fire extinguisher ABC Type 6 Kg |
| 99 | Sand buckets 2 Nos. on each earth stand with canopy |
| 100 | First Aid Boxes |
| 101 | 33 KV Hand Gloves |
| 102 | 11 KV Hand Gloves |
| 103 | Earth Discharge Rod -33 KV |
| 104 | Rubber Mat for 33 KV 6 x 4 feet (Thickness as per IS 15652) |
| 105 | Insulation Tester (Megger Make) 5000 VA |
| 106 | Earth Tester |
| 107 | Mili Amp AC Clamp Meter (make Motwani) |
| 108 | Digital Multimeter |
| 109 | H- BEAM 11 METER 152 X 152 MM 37.1 KG/METER = 408.1 kg |
| 110 | DC.CROSS ARMS 8` CENTRE TO CENTRE 100X50X6 MM CHANNEL (each weight-26.32 Kg) (ONE SET FOR FEEDER AND ONE SET FOR ISOLATOR/ME) |
| 111 | Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg) |
| 112 | HORIZONATAL & CROSS BRACING 8' CENTRE (wt of each X-BRACING-64.29 Kg |
| 113 | Back Clamp suitable for H-Beam (MS Flat 65x8 mm)- each weight 1.92 Kg |
| 114 | 33 KV Polymer composite 70 KN Disc Insulator |
| 115 | 33 KV Strain hardware (T&C type) fittings |
| 116 | 33 KV 900 mm CD Polymer Composite pin insulator |
| 117 | Stay set 20 mm. complete without Stay wire (Hot Dipped galvanized) |
| 118 | Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg) |
| 119 | STAY WIRE 7/4.00 MM.(7/8 SWG)(8.5 kg./stay) |
| 120 | Stone Block/Pre cast block for base pedding 450x450x75mm |
| 121 | CONCRETING (1:3:6) OF H-BEAM @ 0.7 CMT.PER POLE INCLUDING muffing |
| 122 | CONCRETING (1:3:6) OF STAY @ 0.3 CMT. PER STAY (20MM) |
| 123 | EARTHING COIL OF 115 TURNS OF 50 MM.DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE |
| 124 | H- BEAM 9 METER 152 X 152 MM 37.1 KG/METER = 333.9 kg. FOR 33KV GANTRY STRUCTURE |
| 125 | H- BEAM 9 METER 152 X 152 MM 37.1 KG/METER = 333.9 kg. FOR 11KV GANTRY STRUCTURE |
| 126 | H- BEAM 7 METER 152 X 152 MM 37.1 KG/METER = 259.7 kg. FOR 5' CENTER JUMPER SUPPORT FOR 33 & 11KV SIDE |
| 127 | D.C. CHANNEL 4.8 MTR CENTRE 100X50X6MM FOR 33KV BUS BAR (each weight-99.90 Kg) |
| 128 | D.C. CHANNEL 4.8 MTR CENTRE 100X50X6MM FOR 11KV BUS BAR (each weight-99.90 Kg) |
| 129 | D.C.cross- arm of 100 X 50 X 6 mm. ISMC channel suitable for 5' centre (65.09 kg each) |
| 130 | Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg) |
| 131 | STRAIN PLATE (IS Angle MS FLAT 65X8X250MM) 0.65 Kg each |
| 132 | ACSR PANTHER CONDUCTOR 0.20 SQ. INCH (200 SQ.MM AL.EQ.) |
| 133 | 33 KV 900 mm CD Polymer Composite pin insulator |
| 134 | 33 KV Top clamps 75x75x6 mm Angle ( each weight 3.58 Kg) |
| 135 | 11 KV, 5KN PIN COMPOSITE POLYMER INSULATOR |
| 136 | 11 KV TOP CLAMPS 65X65X6MM ANGLE TYPE (each weight-3.0 Kg) |
| 137 | 33 KV Polymer composite 70 KN Disc Insulator |
| 138 | 33 KV COMPOSITE POLYMER STRAIN SET WITH HARD WARE SUITABLE FOR PANTHER CONDUCTOR (FOR 33KV SIDE) |
| 139 | 33 KV , 45 KN 16mm FRP with 25mm per KV Creepage DISC POLYMER LONG ROD TYPE T&C INSULATOR (FOR 11KV SIDE) |
| 140 | 33 KV COMPOSITE POLYMER STRAIN SET WITH HARD WARE SUITABLE FOR PANTHER CONDUCTOR (FOR 11KV SIDE) |
| 141 | Stone Block/Pre cast block for base pedding 450x450x75mm |
| 142 | CONCRETING (1:3:6) OF H-BEAM @ 0.70CMT.PER POLE INCLUDING muffing |
| 143 | H- BEAM 11 METER 152 X 152 MM 37.1 KG/METER = 408.1 kg |
| 144 | DC.CROSS ARMS 8` CENTRE TO CENTRE 100X50X6 MM CHANNEL (each weight-56.32 Kg) |
| 145 | 11 KV, 5KN PIN COMPOSITE POLYMER INSULATOR |
| 146 | 11 KV STRAIN HARDWARE (T&C TYPE) FITTINGS |
| 147 | HORIZONATAL & CROSS BRACING 8' CENTRE (wt of each X-BRACING-64.29 Kg |
| 148 | Back Clamp suitable for H-Beam (MS Flat 65x8 mm)- each weight 1.92 Kg |
| 149 | Stay set 20 mm. complete without Stay wire (Hot Dipped galvanized) |
| 150 | Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg) |
| 151 | Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set ) |
| 152 | Stone Block/Pre cast block for base pedding 450x450x75mm |
| 153 | CONCRETING (1:3:6) OF H-BEAM @ 0.70 CMT.PER POLE INCLUDING muffing |
| 154 | CONCRETING (1:3:6) OF STAY @ 0.3 CMT. PER STAY (16MM) |
| 155 | EARTHING COIL OF 115 TURNS OF 50 MM.DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE |
| 156 | BIS certified Energy Efficiency Level-III (Old)/Level-II (New) 33/0.433KV, 63 KVA Distribution Transformer (As per IS 1180 latest amendment) |
| 157 | DC.CROSS ARMS 8` CENTRE TO CENTRE 100X50X6 MM CHANNEL (each weight-26.32 Kg) |
| 158 | Clamp A type 65x8mm of MS Flat for R.S. Joist(175x85mm) |
| 159 | 11 KV, 45 KN DISC T&C COMPOSITE POLYMER LONG ROD INSULATOR |
| 160 | 11 KV STRAIN HARDWARE (T&C TYPE) FITTINGS |
| 161 | 9 KV Gapless type LA ( 5KA) Polymer for DTR |
| 162 | D.O.MOUNTING CHANNEL 75X40X6MM (each wt 19.37 Kg) |
| 163 | 11 KV Drop out Fuse (Porcelin) |
| 164 | TRANSFORMER MOUNTING CHANNEL 100X50X6MM (each wt 52.63 Kg) |
| 165 | TRANSFORMER CLAMPING SET 50X50 X6 MM ANGLE 460MM LONG (each wt 52.63 Kg) |
| 166 | ACSR Rabitt 50 sqmm |
| 167 | DANGER BOARD ENAMELED 11 KV |
| 168 | L.T.DISTRIBUTION BOX FOR 63 KVA TRANSFORMER (200 A. ISOLATOR & 6 SP MCCB OF 90 A.) made of SMC |
| 169 | DANGER BOARD ENAMELED 11 KV |
| 170 | L.T.DISTRIBUTION BOX FOR 63 KVA TRANSFORMER (200 A. ISOLATOR & 6 SP MCCB OF 90 A.) made of SMC |
| 171 | XLPE LT 1 - CORE ALUMINIUM UNARMOURED 70 SQMM CABLE |
| 172 | XLPE LT 1 - CORE ALUMINIUM UNARMOURED 120 SQMM CABLE |
| 173 | Stone Block/Pre cast block for base pedding 450x450x75mm |
| 174 | CONCRETING (1:3:6) OF H-BEAM @ 0.6 CMT.PER POLE INCLUDING BASE PEDDING |
| 175 | 33/11 KV Power transformer , OFTC Type , 3150 KVA (Loss 3+15 KW) |
| 176 | Supply Installation and Commissioning of Indoor 33 KV 1200Amp 4 Panel VCB Breaker Panel (Including One Incomer & Three Outgoing) with inbuilt Line CT, PT, Power Pack and Transmission Line Protection Protection for I/C panel & 1 no O/G panel and Transformer protection for 2 O/G panel etc all complete as per approved drawing |
| 177 | 11 KV 630 Amp, 25kA Indoor VCB Panel Complete with CT PT, Relays etc. all accessories |
| 178 | 11 KV 1000 KVAR AUTO SWITCH CAPACITOR BANK INCLUDING ASSOCIATED EQUIPMENTS SUCH AS 11 KV VACUUM CIRCUIT BREAKER, CONTROL PANEL, 11 KV OUTDOOR CURRENT TRANSFORMER WITH ADEQUATE METERING & PROTECTION CLASS OF SERVICE, BUS & EQUIPMENT ISOLATORS WITH EARTH SWITCH, MATCHING RVT, SUITABLE GAPLESS LIGHTENING ARRESTORS, NECESSARY CABLES FOR SUCCESSFUL COMMISSIONING COMPLETE |
| 179 | 11 KV Under-Ground XLPE armoured Cable 3X120 Sq.mm. |
| 180 | Indoor heat shrinkable cable end jointing kit with lugs for 11 kV grade XLPE cable for 3 core 120 sq mm |
| 181 | 33 KV ISOLATOR 630 A. |
| 182 | 11 KV ISOLATOR 800 Amp |
| 183 | 33 KV LA POLYMER TYPE GAPLESS /METAL OXIDE SUBSTATION TYPE |
| 184 | 11 KV LA POLYMER TYPE GAPLESS /METAL OXIDE SUBSTATION TYPE |
| 185 | 33 KV / 0.11 kv SINGLE PHASE PTS OIL IMMERSED, outdoor with marshling box |
| 186 | 11 KV / 0.11 kv SINGLE PHASE PTS OIL IMMERSED, outdoor with marshling box |
| 187 | For substation metering- 3 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HT trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible ) modems, |
| 188 | SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB |
| 189 | COPPER CONTROL CABLE 12 CORE, 2.5 SQMM PVC UNARMOURED |
| 190 | COPPER CONTROL CABLE 8 CORE, 2.5 SQMM PVC UNARMORED |
| 191 | COPPER CONTROL CABLE 4 CORE, 2.5 SQMM PVC UNARMOURED |
| 192 | COPPER CONTROL CABLE 2 CORE, 2.5 SQMM PVC UNARMOURED |
| 193 | T CLAMP ALUMINUM FOR BUS BAR PANTHER RUN PANTHER TAP |
| 194 | BIMETALLIC CLAMPS FOR POWER TRANSFORMER 11KV SIDE |
| 195 | PVC CABLE 2 CORE ARMOURED 2.5 SQMM ALUMINIUM CONDUCTOR |
| 196 | PVC CABLE 4 CORE ARMOURED 16 SQMM ALUMINIUM CONDUCTOR |
| 197 | M S BOLT WITH NUT 16X250 MM |
| 198 | M S BOLT WITH NUT 16X200 MM |
| 199 | M S BOLT WITH NUT 16X165 MM |
| 200 | M S BOLT WITH NUT 16X140 MM |
| 201 | M S BOLT WITH NUT 16X90 MM |
| 202 | M S BOLT WITH NUT 16X40 MM |
| 203 | RED-OXIDE PAINT |
| 204 | ALUMINUM PAINT |
| 205 | DANGER BOARD ENAMELED 33 KV AND 11 KV |
| 206 | 11 KV new Line inside Dhajnagar IE up to 1.6KM |
| 207 | Line supports Full GI MS Tubular Pole 11 m Long |
| 208 | 11 KV 'V' cross-arms 75x75x6 mm MS Angle -each weight 24.60 Kg |
| 209 | Back Clamp (MS Flat 65x8 mm) - each wt 1.92 Kg |
| 210 | 11 KV Top clamps 75x75x6 mm Angle ( each weight 3.58 Kg) |
| 211 | 11 KV Single Pole Cut Point Channal (100x50x6mm MS Channel) 1.65 mtr Long |
| 212 | 11 KV Side cross arm (100x50x6mm MS Channel) |
| 213 | Earthing Coil ( coil of 115 turns of 50 mm.dia. and 2.5 Mtrs. lead of 4.0 mm. G.I wire) |
| 214 | 11 KV Pin Insulator(Polymer) composite 10KN FRP Dia 33.5mm |
| 215 | ACSR Weasel Covered conductor (50 sq.mm. Al.Eq.), 11 kv |
| 216 | Jointing Sleeves suitable for 50Sq.mm. conductor |
| 217 | HT kiosks complete |
| 218 | Stay set 20 mm. painted complete with turn buckles |
| 219 | Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set ) |
| 220 | Clamp (3.04 kg each) |
| 221 | Stay Insulators 90X65mm |
| 222 | Concreting of pole @ 0.9 cmt. per pole including muffing |
| 223 | Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay |
| 224 | Red oxide paint |
| 225 | Aluminium paint |
| 226 | Anti-climbing devices (Barbed wire 2.24 mm dia. 14 SWG) |
| 227 | Danger Boards Enamalled Type 11KV |
| 228 | Binding wire and tape |
| 229 | M.S.Nuts and Bolts |
| 230 | Dismentalling of 11 KV Network, Pole, fittings and Conductor: Existing Line for HT Consumers up to 0.7 KM |
| 231 | Dismantling of 10 mtrs,11mtrs & 12mtrs length of steel Tubular Pole at any kind of soil,including excavation of earth,refilling the pit with soil upto the ground level,ramming and making complete in all respect. |
| 232 | Dismantling of stay set from the earth complete with 19mmx1800mm long stay rod,anchor plate of size 300x300x8mm,thimble,turn buckle,7/3.15mm dia G.I. Standard stay wire and stain insulator etc. and making complete in all respet |
| 233 | Dismantling of 11KV pin insulator along with pin |
| 234 | Dismantling of Disc insulator set for 11KV line along with necessary fittings |
| 235 | Dismantling of 3KM(Single Conductor) ACSR 6/1/4.10 mm dia RACOON including coiling etc. Complete as required |
| 236 | Dismantling of Barbed wire (Anti climbing device) per pole |
| 237 | Dismantling of 3KM (Single Conductor),10/8 SWG GI wire including coiling etc.Complete as required. |
| 238 | Transport Charges from Site to TSECL Store |
| 239 | Supply and Installation of 315 KVA, 11/0.4 KV DTR |
| 240 | BIS certified Energy Efficiency Level-III (Old)/Level-II (New) 11/0.433KV, 315 KVA Distribution Transformer (IS 1180 latest Amendment) |
| 241 | Full GI MS Tubular Pole 11 m Long |
| 242 | D.c.cross-arm of 100 x50x 6 mm. 8' centre |
| 243 | 11 kv (45kn) 16mm frp with 25mm per kv creepage disc insulator polymer |
| 244 | 11kv strain hard ware fitting |
| 245 | 11 kv d.o. fuse & lightening arrestor mounting channel (75x 40 x 6 mm.) |
| 246 | Back clamp for h-beam size-480 mm ,wt-1.92 kg using 65x8 ms flat |
| 247 | 11 kv d.o. fuse unit |
| 248 | 9 kv gapless type LA ( 5ka) polymer for dtr |
| 249 | 315KVA Transformer Base (R.C.C.) as per TSECL approved drawings |
| 250 | Clamp for h-beam size- ,wt-3.2 kg using 65x8 ms flat |
| 251 | Stay set 20 mm. painted complete with turn buckles |
| 252 | Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set ) |
| 253 | Stone block/pre cast block for base pedding 450x450x75mm |
| 254 | Concreting of h-beam @ 0.70 cmt. Per pole with muffing (1:3:6) |
| 255 | Concreting of stay @ 0.2 cmt. Per stay (1:3:6) |
| 256 | Acsr conductor rabbit for jumper |
| 257 | Danger boards enamalled type 11kv |
| 258 | Bi-metallic clamps Distribution Transformers Bushing HT side |
| 259 | Bi-metallic clamps suitable for 12mm dia. stud LT side |
| 260 | Anti climbing devices (barbed wire 2.24 mm dia (14 swg) (3.5 kg. Wire per pole) |
| 261 | Red oxide paint |
| 262 | Aluminium paint |
| 263 | M.s.nuts and bolts |
| 264 | Distribution box mounting channel (75x40x6 mm.) |
| 265 | L.t. distribution box suitable for 315 kva transformer (without tpn switches) with mccb on incoming and pf units on outgoing side made of smc |
| 266 | LT 300 sq.mm.,3.5 core xlpe armoured aluminium conductor cable |
| 267 | LT Al Lugs 300 sqmm |
| 268 | 11 kV A.B. switch, 400amps with complete fitting. |
| 269 | DTR S/s fencing (Total 37 feet running meter max.) of 6' height with chain link fencing on MS Angle(50x50x6mm) support 7 nos. 7' height. |
| 270 | Earthing of DTR (G.I. Pipe 40 mm dia., 3m long) |
| 271 | Supply and Installation of 200 KVA, 11/0.4 KV DTR |
| 272 | BIS certified Energy Efficiency Level-III (Old)/Level-II (New) 11/0.433KV, 200 KVA Distribution Transformer(As per IS 1180, latest Amendment) |
| 273 | Full GI MS Tubular Pole 11 m Long |
| 274 | D.c.cross-arm of 100 x50x 6 mm. 8' centre |
| 275 | 11 kv (45kn) 16mm frp with 25mm per kv creepage disc insulator polymer |
| 276 | 11kv strain hard ware fitting |
| 277 | 11 kv d.o. fuse & lightening arrestor mounting channel (75x 40 x 6 mm.) |
| 278 | Back clamp for h-beam size-480 mm ,wt-1.92 kg using 65x8 ms flat |
| 279 | 11 kv d.o. fuse unit |
| 280 | 9 kv gapless type LA ( 5ka) polymer for dtr |
| 281 | Transformer mounting dc cross-arm 100 x 50 x6 mm. Channel |
| 282 | Transformer belting with 50 x 50 x 6 mm.angle with two cross fixing channels |
| 283 | Clamp for h-beam size- ,wt-3.2 kg using 65x8 ms flat |
| 284 | Stay set 20 mm. painted complete with turn buckles |
| 285 | Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set ) |
| 286 | Stone block/pre cast block for base pedding 450x450x75mm |
| 287 | Concreting of h-beam @ 0.70 cmt. Per pole with muffing (1:3:6) |
| 288 | Concreting of stay @ 0.2 cmt. Per stay (1:3:6) |
| 289 | Acsr conductor rabbit for jumper |
| 290 | Danger boards enamalled type 11kv |
| 291 | Bi-metallic clamps Distribution Transformers Bushing HT side |
| 292 | Bi-metallic clamps suitable for 12mm dia. stud LT side |
| 293 | Anti climbing devices (barbed wire 2.24 mm dia (14 swg) (3.5 kg. Wire per pole) |
| 294 | Red oxide paint |
| 295 | Aluminium paint |
| 296 | M.s.nuts and bolts |
| 297 | Distribution box mounting channel (75x40x6 mm.) |
| 298 | L.t. distribution box suitable for 200 kva transformer (without tpn switches) with mccb on incoming and pf units on outgoing side made of smc |
| 299 | LT 185 sq.mm.,3.5 core xlpe armoured aluminium conductor cable |
| 300 | LT Al Lugs 185 sqmm |
| 301 | 11 kV A.B. switch 400 amps with complete fitting. |
| 302 | DTR S/s fencing (Total 37 feet running meter max.) of 6' height with chain link fencing on MS Angle(50x50x6mm) support 7 nos. 7' height. |
| 303 | Earthing of DTR (G.I. Pipe 40 mm dia., 3m long) |
| 304 | New LT Feeder with ABC 150 sq mm Cable |
| 305 | Binding wire and tape |
| 306 | M.S.Nuts and Bolts |
| 307 | A.B Cable tension clamps (Galvanized) |
| 308 | Suspension Clamp with attachment |
| 309 | Clamp for Neutral |
| 310 | Piercing connector Type-I for single phase/three phase(Main 70-150 sq.mm. tape- of 50-95 sq.mm) |
| 311 | Piercing connector Type-II (Main 70-150 sq.mm. tape- of 50-95 sq.mm) |
| 312 | 1100 Volts Grade Aerial bunched XLPE Cable 3 X 150 + 1 X 35 + 1 X 95 sq.mm. (insulated nuetral massenger) |
| 313 | Feeder pillars complete |
| 314 | Dismantling of LT line |
| 315 | Dismentalling of LT Network, Conductor: Existing Line inside IE |
| 316 | Dismantling of 7.5mtrs & 8mtrs length of P.C.C. Pole at any kind of soil ,including excavation of earth,refilling the pit with soil upto the ground level,ramming and making complete in all respect. |
| 317 | Dismantling of MS angle Cross-Arm 1.0 to 1.6 Mtr long 65x65x6 mm |
| 318 | Dismantling of C type bracket for LT 5-wire of 50x50x6mm/65x65x6mm |
| 319 | Dismantling of Barbed wire(Anti climbing device) per pole |
| 320 | Dismantling of stay set from the earth complete with 19mmx1800mm long stay rod,anchor plate of size 300x300x8mm,thimble turn buckle,7/3.15mm dia G.I standed stay wire and stain insulator etc. and making complete in all respect. |
| 321 | Dismantling of 11KV Pin insulator along with Pin |
| 322 | Dismantling of (Single Conductor) ACSR 6/1/4.10mm dia RACOON including coiling etc.Complete as required. |
| 323 | Transport Charges from Site to TSECL Store |
| 324 | Supply and Installation of Street Light LED Lamps on Street Light Poles |
| 325 | Clamps / Arm Brackets / fixing arrangement for Street Light fittings suitable for LED Fixture |
| 326 | Supply and Installation LED Lamp Fitting, for Street Light 100 Watt, with polycarbonate glass cover with IP66 enclosure and complete fittings and connection from Pole Junction Box |
| 327 | 3 Core 1.5 sq mm unarmoured Cable for Street Light connection |
| 328 | Junction Box |
| 329 | Supply and Laying of Street Light Cable 4 Core 16 sq mm armoured underground inside 32 mm MDPE Pipe pipe PN6 |
| 330 | 32 mm HDPE Pipe pipe PN6 for laying of cable |
| 331 | Supply and fixing of Post Top LED lamp in main gate with GI Pipe and loop box LED Lamp 120 Watt |
| 332 | Timer Switch |
| 333 | Excavation of soil 30cmX75cm for cable laying |
| 334 | Route Survey |
| 335 | Dismentalling of Street Light Network, Conductor, and Pole and fixtures & fittings: Existing Line inside IE |
| 336 | Supply and Installation of High Mast Lighting |
| 337 | Supply of 20 M high mast shaft suitable for 39 m/sec wind speed, with all accessories including foundation bolts, aviation light, feeder pillar & suitable as per illumination design Wiring material,power cables between panel and mast, MCB in base compartment are not included & shall be in the scope of erection. |
| 338 | Supply of non-integral LED floodlight luminaries upto 250 Watts, 8 No. in each pole HPI/T Plus lamps and its control gear boxes. |
| 339 | Provision of GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. (2nos per mast required) |
| 340 | Power and Control Panel Outdoor and Environment Protection |
| 341 | Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour. |
| 342 | Erection and Commissioning of the high mast with all wiring materials. |
| 343 | Environment Management plan |
| 344 | Testing of environmental parameter (Ambient Air Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-18 months of 2 locations, once a quarter (09 samples) of two sector/Component |
| 345 | Testing of environmental parameter (Water Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-18 months of 2 locations, once a quarter (09 samples) of two sector/Component |
| 346 | Testing of environmental parameter (Ambient Noise Level) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-18 months of 2 locations, once a quarter (09 samples) of two sector/Component |
| 347 | Testing of environmental parameter (Soil Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-18 months of 2 locations, once a quarter (09 samples) of two sector/Component |
| 348 | Testing of environmental parameter (Ambient Air Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of two sector/Component. |
| 349 | Testing of environmental parameter (Water Quality) within IE through NABL/MoEFCC Accredited Laboratory.Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of two sector/Component. |
| 350 | Testing of environmental parameter (Ambient Noise Level) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of two sector/Component. |
| 351 | Testing of environmental parameter (Soil Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of two sector/Component. |
| 352 | LOCATION: Sarasima Industrial Estate |
| 353 | New 11 KV & LT Compolsite Line inside Sarasima IE up to 2KM |
| 354 | Full GI Tubular Pole 11 m Long |
| 355 | 11 KV 'V' cross-arms 75x75x6 mm MS Angle -each weight 24.60 Kg |
| 356 | Back Clamp (MS Flat 65x8 mm) - each wt 1.92 Kg |
| 357 | 11 KV Top clamps 75x75x6 mm Angle ( each weight 3.58 Kg) |
| 358 | 11 KV Single Pole Cut Point Channal (100x50x6mm MS Channel) 1.65 mtr Long |
| 359 | 11 KV Side cross arm (100x50x6mm MS Channel) |
| 360 | Earthing Coil ( coil of 115 turns of 50 mm.dia. and 2.5 Mtrs. lead of 4.0 mm. G.I wire) |
| 361 | 11 KV Pin Insulator(Polymer) composite 10KN FRP Dia 33.5mm |
| 362 | ACSR Weasel Covered conductor (50 sq.mm. Al.Eq.), 11 kv |
| 363 | Jointing Sleeves suitable for 100Sq.mm. conductor |
| 364 | Stay set 20 mm. painted complete with turn buckles |
| 365 | Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set ) |
| 366 | Clamp (3.04 kg each) |
| 367 | Stay Insulators 90X65mm |
| 368 | Concreting of pole @ 0.9 cmt. per stay including muffing |
| 369 | Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay |
| 370 | Red oxide paint |
| 371 | Aluminium paint |
| 372 | Anti-climbing devices (Barbed wire 2.24 mm dia. 14 SWG) |
| 373 | Danger Boards Enamalled Type 11KV |
| 374 | Binding wire and tape |
| 375 | M.S.Nuts and Bolts |
| 376 | A.B Cable tension clamps (Galvanized) |
| 377 | Suspension Clamp with attachment |
| 378 | Clamp for Neutral |
| 379 | Piercing connector Type-I for single phase/three phase(Main 70-150 sq.mm. tape- of 50-95 sq.mm) |
| 380 | Piercing connector Type-II (Main 70-150 sq.mm. tape- of 50-95 sq.mm) |
| 381 | 1100 Volts Grade Aerial bunched XLPE Cable 3 X 150 + 1 X 35 + 1 X 95 sq.mm. (insulated nuetral massenger) |
| 382 | Route Survey of existing line and proposed network |
| 383 | Replacement of old 11 KV Weasel conductor by covered weasel conductor up to 1.5KM |
| 384 | 11 KV Pin insulator Polymer Composite (5KN) FRP dia 24mm |
| 385 | ACSR Conductor Weasel Coveredwith 3 % Sag |
| 386 | Jointing Sleeves suitable for 80 Sq. mm.Al. |
| 387 | Painted Stay set 20 mm. complete with turn buckles |
| 388 | Stay wire 7/4.0 mm. (10 kg.stay wire per stay set ) |
| 389 | Clamp suitable ( each weight 3.2 kg ms flat 65x8mm) |
| 390 | Red oxide paint |
| 391 | Aluminium paint |
| 392 | Anti-climbing devices (Barbed wire 2.24 mm dia. 14 SWG) |
| 393 | Danger Boards Enamalled Type 11KV |
| 394 | Binding wire and tape |
| 395 | M.S.Nuts and Bolts |
| 396 | A.B Cable tension clamps (Galvanized) |
| 397 | Suspension Clamp with attachment |
| 398 | Clamp for Neutral |
| 399 | Piercing connector Type-I for single phase/three phase(Main 70-150 sq.mm. tape- of 50-95 sq.mm) |
| 400 | Piercing connector Type-II (Main 70-150 sq.mm. tape- of 50-95 sq.mm) |
| 401 | 1100 Volts Grade Aerial bunched XLPE Cable 3 X 150 + 1 X 35 + 1 X 95 sq.mm. (insulated nuetral massenger) |
| 402 | Route Survey of existing line and proposed network |
| 403 | Dismentalling Cost |
| 404 | Construction of 11 KV Bay at 33/11 KV Sarasima Town SS |
| 405 | Supply of 11 KV vacuum circuit breaker(VCB) with control and relay panel (incoming), simplex type 800A continuous current rating, 250 MVA rupturing capacity with manual and motorised spring closing mechanism,electrical closing and opening arrangement and internal panel wiring with provisions of 2-over current & 1-earth fault combined relay, auxiliary relays, 1-Voltmeter, 3-Ammeter, 1 - CT operated static tri-vector meter(TVM). CTR = 300/ 1-1-0.577. PTR = 11000/√3 / 110/√3. |
| 406 | Design, engineering, supply, testing and commissioning of 11 kv adapter panel for 1250 ampwith allied accessories and cables |
| 407 | 11 kv.c.ts.(outdoor dry type) 300-150/5 amps |
| 408 | 11 KV Control & Relay Panel for 11 KV Outdoor VCB with IEC 61850 compliant differential relay, numerical type with static TVM |
| 409 | 11 kv isolator 800 a.(turn & twist type) |
| 410 | 11 kv la polymer type gapless /metal oxide 9 kv , 10 ka substation type |
| 411 | 11 kv single phase pts oil immersed |
| 412 | For substation metering- 3 phase 4 wire 3x63.5 volts lb=5 amps imax = 10 amp, ht trivector meter class of accuracy 0.5s, dlms compliant category a meters along with gsm (gprs compatible ) modems, |
| 413 | Sheet metal meter box suitable for h.t. static travector meters with ttb |
| 414 | Copper control cable 12 core, 2.5 sqmm pvc unarmoured |
| 415 | Copper control cable 8 core, 2.5 sqmm pvc unarmored |
| 416 | Copper control cable 4 core, 2.5 sqmm pvc unarmoured |
| 417 | Copper control cable 2 core, 2.5 sqmm pvc unarmoured |
| 418 | T clamp aluminum for bus bar panther run panther tap |
| 419 | Bimetallic clamps for power transformer 11kv side |
| 420 | H- beam 9 meter 152 x 152 mm 37.1 kg/meter = 333.9 kg. For 33kv gantry structure |
| 421 | D.c. channel 4.8 mtr centre 100x50x6mm for 33kv bus bar (each weight-99.90 kg) |
| 422 | Clamp suitable for 152 x 152 mm., 37.1 kg./mtr h-beam ( each weight 3.2 kg) |
| 423 | Strain plate (IS MS flat 65x8x250mm) 0.65 kg each |
| 424 | Acsr panther conductor 0.20 sq. Inch (200 sq.mm al.eq.) |
| 425 | 11 kv, 5kn pin composite polymer insulator |
| 426 | 11 kv top clamps 65x65x6mm angle type (each weight-3.0 kg) |
| 427 | 11 kv , 45 kn 16mm frp with 25mm per kv creepage disc polymer long rod type t&c insulator (for 11kv side) |
| 428 | 11 kv composite polymer strain set with hard ware suitable for panther conductor (for 11kv side) |
| 429 | Stone block/pre cast block for base pedding 450x450x75mm |
| 430 | Concreting (1:3:6) of h-beam @ 0.70cmt.per pole including muffing |
| 431 | Concreting (1:3:6) of vcb structures 3.5 cmt per vcb |
| 432 | Concreting (1:3:6) of isolator support structure @ 0.1 cmt. Per structure |
| 433 | M s bolt with nut assorted size |
| 434 | Red-oxide paint |
| 435 | Aluminum paint |
| 436 | CO2 Fire Extinguisher (6Kg) Dry Type |
| 437 | Shock Treatment Chart |
| 438 | Sand buckets 2 Nos. on each earth stand with canopy |
| 439 | First Aid Boxes |
| 440 | 11 KV Hand Gloves |
| 441 | Earth Discharge Rod -132 KV (ES-132 BEIMCO) |
| 442 | Earth Discharge Rod -11 kv |
| 443 | Meggar 5000 VA |
| 444 | Earth Tester |
| 445 | Danger board enameled11 kv |
| 446 | Under Ground Fault Detector |
| 447 | Supply and Installation of 500 KVA (4 No.s), 11/0.4 KV DTR at Sarasima IE |
| 448 | BIS certified Energy Efficiency Level-III (Old)/Level-II (New), 11/0.433KV, 500 KVA Distribution Transformer (As per IS 1180 Latest Amendment) |
| 449 | H-beams 152 x 152 mm., 37.1 kg./mtr.-11 mtr. Long = 408.1 kg |
| 450 | D.c.cross-arm of 100 x50x 6 mm. 8' centre |
| 451 | Clamp for h-beam size-800 mm ,wt-3.2 kg using 65x8 ms flat |
| 452 | 11 kv (45kn) 16mm frp with 25mm per kv creepage disc insulator polymer |
| 453 | 11kv strain hardware fitting |
| 454 | 11 kv d.o. fuse & lightening arrestor mounting channel (75x 40 x 6 mm.) |
| 455 | Back clamp for h-beam size-480 mm ,wt-1.92 kg using 65x8 ms flat |
| 456 | 11 kv d.o. fuse unit |
| 457 | 9 kv gapless type ( 5ka) polymer for dtr |
| 458 | Transformer mounting dc cross-arm 100 x 50 x6 mm. Channel |
| 459 | Transformer belting with 50 x 50 x 6 mm.angle with two cross fixing channels |
| 460 | Clamp for h-beam size- ,wt-3.2 kg using 65x8 ms flat |
| 461 | Stay set 16 mm. Painted complete with turn buckles |
| 462 | Stay wire 7/3.15 mm. (7.5 kg.stay wire per stay set ) |
| 463 | Clamp for h-beam size- ,wt-3.2 kg using 65x8 ms flat |
| 464 | Stone block/pre cast block for base pedding 450x450x75mm |
| 465 | Concreting of h-beam @ 0.70 cmt. Per pole with muffing (1:3:6) |
| 466 | Concreting of stay @ 0.2 cmt. Per stay (1:3:6) |
| 467 | Acsr conductor rabbit for jumper |
| 468 | Danger boards enamalled type 11kv |
| 469 | Bi-metallic clamps Distribution Transformers Bushing HT side |
| 470 | Bi-metallic clamps suitable for 12mm dia. stud LT side |
| 471 | Anti climbing devices (barbed wire 2.24 mm dia (14 swg) (3.5 kg. Wire per pole) |
| 472 | Red oxide paint |
| 473 | Aluminium paint |
| 474 | M.s.nuts and bolts |
| 475 | Distribution box mounting channel (75x40x6 mm.) |
| 476 | Back clamp for h-beam size- ,wt-1.92 kg using 65x8 ms flat |
| 477 | L.t. distribution box suitable for 500 kva transformer (without tpn switches) with mccb on incoming and pf units on outgoing side made of smc |
| 478 | LT 300 sq.mm.,3.5 core xlpe armoured aluminium conductor cable |
| 479 | LT Al Lugs 300 sqmm |
| 480 | 11 kV A.B. switch 400 amps with complete fitting. |
| 481 | DTR S/s fencing (Total 37 feet running meter max.) of 6' height with chain link fencing on MS Angle(50x50x6mm) support 7 nos. 7' height. |
| 482 | Earthing of DTR (Neutral+Body+Pole+LA)(4 earth=1 Set)(G.I. Pipe 40 mm dia., 3m long) |
| 483 | Supply and Installation of 315 KVA, 11/0.4 KV DTR |
| 484 | BIS certified Energy Efficiency Level-III (Old)/Level-II (New) 11/0.433KV, 315 KVA Distribution Transformer(As per IS 1180 latest amendment) |
| 485 | MS Steel Tubular Pole 11 m |
| 486 | D.C.cross-arm of 100 X50X 6 mm. 8' centre |
| 487 | Clamp using 65X8 Ms Flat |
| 488 | 11 KV (45KN) 16mm FRP with 25mm per KV creepage Disc Insulator Polymer |
| 489 | 11KV Strain hard ware fitting |
| 490 | 11 KV D.O. fuse & Lightening Arrestor mounting channel (75X 40 X 6 mm.) |
| 491 | Back Clamp ,Wt-1.92 Kg using 65X8 Ms Flat |
| 492 | 11 KV D.O. fuse unit |
| 493 | 9 KV Gapless type ( 5KA) Polymer for DTR |
| 494 | Transformer mounting DC cross-arm 100 X 50 X6 mm. channel |
| 495 | Transformer belting with 50 X 50 X 6 mm.angle with two cross fixing channels |
| 496 | Stay set 16 mm. painted complete with turn buckles |
| 497 | Stay wire 7/3.15 mm. (7.5 kg.stay wire per stay set ) |
| 498 | Stone Block/Pre cast block for base pedding 450x450x75mm |
| 499 | Concreting of pole @ 0.50 cmt. per pole with muffing |
| 500 | Concreting of Stay @ 0.2 cmt. per stay |
| 501 | ACSR Conductor Racoon conductor for jumper |
| 502 | Danger Boards Enamalled Type 11KV |
| 503 | Bi-metallic clamps Distribution Transformers Bushing HT side |
| 504 | Bi-metallic clamps suitable for 12mm dia. stud LT side |
| 505 | Anti climbing devices (Barbed wire 2.24 mm Dia (14 SWG) (3.5 Kg. wire per pole) |
| 506 | Red oxide paint |
| 507 | Aluminium paint |
| 508 | M.S.Nuts and Bolts |
| 509 | Distribution Box mounting channel (75x40x6 mm.) |
| 510 | L.T. Distribution box suitable for 315 KVA transformer (without TPN switches) with MCCB on incoming and PF units on outgoing side made of SMC |
| 511 | 150 Sq.mm.,single core XLPE insulated un-armoured aluminium conductor cable |
| 512 | 300 Sq.mm.,single core XLPE insulated un-armoured aluminium conductor cable |
| 513 | 11 KV AB Switch, 400 Amp with Complete fitting |
| 514 | Earthing of DTR (Neutral+Body+Pole+LA)(4 earth=1 Set) (G.I. Pipe 40 mm dia., 3m long) |
| 515 | Supply and Installation of 200 KVA, 11/0.4 KV DTR |
| 516 | BIS certified Energy Efficiency Level-III (Old)/Level-II (New) 11/0.433KV, 200 KVA Distribution Transformer(As per IS 1180 latest amendment) |
| 517 | Full GI MS Tubular Pole 11 m Long |
| 518 | D.C.cross-arm of 100 X50X 6 mm. 8' centre |
| 519 | Clamp using 65X8 Ms Flat |
| 520 | 11 KV (45KN) 16mm FRP with 25mm per KV creepage Disc Insulator Polymer |
| 521 | 11KV Strain hard ware fitting |
| 522 | 11 KV D.O. fuse & Lightening Arrestor mounting channel (75X 40 X 6 mm.) |
| 523 | Back Clamp ,Wt-1.92 Kg using 65X8 Ms Flat |
| 524 | 11 KV D.O. fuse unit |
| 525 | 9 KV Gapless type ( 5KA) Polymer for DTR |
| 526 | Transformer mounting DC cross-arm 100 X 50 X6 mm. channel |
| 527 | Transformer belting with 50 X 50 X 6 mm.angle with two cross fixing channels |
| 528 | Stay set 16 mm. painted complete with turn buckles |
| 529 | Stay wire 7/3.15 mm. (7.5 kg.stay wire per stay set ) |
| 530 | Stone Block/Pre cast block for base pedding 450x450x75mm |
| 531 | Concreting of pole @ 0.50 cmt. per pole with muffing |
| 532 | Concreting of Stay @ 0.2 cmt. per stay |
| 533 | ACSR Conductor Racoon conductor for jumper |
| 534 | Danger Boards Enamalled Type 11KV |
| 535 | Bi-metallic clamps Distribution Transformers Bushing HT side |
| 536 | Bi-metallic clamps suitable for 12mm dia. stud LT side |
| 537 | Anti climbing devices (Barbed wire 2.24 mm Dia (14 SWG) (3.5 Kg. wire per pole) |
| 538 | Red oxide paint |
| 539 | Aluminium paint |
| 540 | M.S.Nuts and Bolts |
| 541 | Distribution Box mounting channel (75x40x6 mm.) |
| 542 | L.T. Distribution box suitable for 200 KVA transformer (without TPN switches) with MCCB on incoming and PF units on outgoing side made of SMC |
| 543 | 150 Sq.mm.,single core XLPE insulated un-armoured aluminium conductor cable |
| 544 | 300 Sq.mm.,single core XLPE insulated un-armoured aluminium conductor cable |
| 545 | 11 KV AB Switch, 400 Amp with Complete fitting |
| 546 | Earthing of DTR (Neutral+Body+Pole+LA)(4 earth=1 Set) (G.I. Pipe 40 mm dia., 3m long) |
| 547 | Supply and Installation of Street Light LED Lamps on Street Light Poles |
| 548 | Full GI MS Tubular Pole 11 m Long |
| 549 | Concreting of pole @ 0.50 cmt. per pole with muffing |
| 550 | Earthing Coil ( coil of 115 turns of 50 mm.dia. and 2.5 Mtrs. lead of 4.0 mm. G.I wire) |
| 551 | Supply and Installation LED Lamp Fitting, for Street Light 100 Watt, with polycarbonate glass cover with IP66 enclosure and complete fittings and connection from Pole Junction Box |
| 552 | Clamps / Arm Brackets / fixing arrangement for Street Light fittings suitable for LED Fixture |
| 553 | 3 Core 1.5 sq mm unarmoured Cable for Street Light connection |
| 554 | Junction Box |
| 555 | Supply and Laying of Street Light Cable 3-1-2 Core 16 sq mm armoured underground inside 32 mm MDPE Pipe pipe PN6 |
| 556 | 32 mm MDPE Pipe pipe PN6 for laying of cable |
| 557 | Supply and fixing of Post Top LED lamp in main gate with GI Pipe and loop box LED Lamp 120 Watt |
| 558 | Excavation for cable laying |
| 559 | Route Survey |
| 560 | Supply and Installation of High Mast Lighting |
| 561 | Supply of 20 M high mast shaft suitable for 39 m/sec wind speed, with all accessories including foundation bolts, aviation light, feeder pillar & suitable as per illumination design Wiring material,power cables between panel and mast, MCB in base compartment are not included & shall be in the scope of erection. |
| 562 | Supply of non-integral floodlight luminaries LED 250 Watts, 8 No. in each pole HPI/T Plus lamps and its control gear boxes. |
| 563 | Provision of GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. (2nos per mast required) |
| 564 | Power and Control Panel Outdoor and Environment Protection |
| 565 | Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour. |
| 566 | Erection and Commissioning of the high mast with all wiring materials. |
| 567 | Environment Management plan |
| 568 | Testing of environmental parameter (Ambient Air Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-12 months of 2 locations, once a quarter (06 samples) of two sector/Component. |
| 569 | Testing of environmental parameter (Water Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-12 months of 2 locations, once a quarter (06 samples) of two sector/Component. |
| 570 | Testing of environmental parameter (Ambient Noise Level) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-12 months of 2 locations, once a quarter (06 samples) of two sector/Component. |
| 571 | Testing of environmental parameter (Soil Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-12 months of 2 locations, once a quarter (06 samples) of two sector/Component. |
| 572 | Testing of environmental parameter (Ambient Air Quality) within IE through NABET Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of four sector/Component of two sector/Component |
| 573 | Testing of environmental parameter (Water Quality) within IE through NABET Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of two sector/Component |
| 574 | Testing of environmental parameter (Ambient Noise Level) within IE through NABET Accredited Laboratory.Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of two sector/Component |
| 575 | Testing of environmental parameter (Soil Quality) within IE through NABET Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of two sector/Component |
| 576 | Operation & Maintaince-TSECL Work |
| 577 | For Dhajanagar Industrial Estate |
| 578 | For Sarasima Industrial Estate Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysOct 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender