Public Administrative Department Boards / Undertakings / PSU Closing in 14 days TDR #57717849

Tender For Infrastructure Development Of Industrial Estate In Tripura/ Sh: Power And Electrical - Tsecl Work Etc. At Dhajanagar And Sarasima Industrial Estates (Adb Project/ Package :14)

Issued by Boards / Undertakings / PSU · Gomati, Tripura
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Oct 2026
14 days left
EMD
11.27 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gomati → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Infrastructure Development Of Industrial Estate In Tripura/ Sh: Power And Electrical - Tsecl Work Etc. At Dhajanagar And Sarasima Industrial Estates (Adb Project/ Package :14)

BOQ

Name of Work:- INFRASTRUCTURE DEVELOPMENT OF INDUSTRIAL ESTATE IN TRIPURA/ SH: POWER AND ELECTRICAL – TSECL WORK ETC. AT DHAJANAGAR AND SARASIMA INDUSTRIAL ESTATES (ADB PROJECT/ PACKAGE :14)
Sl. No. Item Description
1LOCATION: Dhajanagar Industrial Estate
2Construction of new 33/11 KV S/s with 3.15 MVA Power Transformer and control room building
3MS MAIN AND WICKET GATE ON RCC COLUMN
4Yard fencing with chain link mesh over RCC beam 2.4 mtr. Height
5Boundary wall with RCC column and Brick work
6MS SIGN BOARD, BAY INDICATION BOARD & RYB PHASE INDICATION BOARD
7Yard Leveling by Kopra filling
8Laying of Metal in yard by 100 mm thick metalling with 40 mm size B.T. Yard level to be increased by grouting Brick placed vertical 100 mm above of the ground and remaining part of the brick kept inside the ground
9Cable Trench (Length suitable for substation area)Construction work of RCC utility duct i/c excavation, base slab, RCC wall, Top slab, RCC drain * drain cover, from works etc, including reinforcement HYSD bar etc., for laying 2 nos. 33KV, 2 no. 11kv, 2 no. LT underground cable.Item Length Width Depthexcavation L 2.85 1.775PCC (M-15) L 1.85 0.075RCC Base Slab L 1.70 0.150(M-25)RCC wall (M-25) 2xL 0.15 1.400Top Slab1 (M-25) L 1.70 0.150
103.15 MVA Transformer
11Yard Equipment Base including CT, PT, Isolator, LA etc
12Full GI MS Tubular Pole 9 m Long FOR YARD LIGHTENING
13LED Flood Lighting 80 Watt
14PROVIDING & FIXING PERFORATED CABLE TRAY 300 MM WIDE & 2 MM THICK FIXED ON 45X45X5 MM M.S. ANGLE STAND GROUTED IN C.C 1:24
15PROVIDING AND FIXING EARTH PIT OF BRICK MASSONERY 0.6 X 0.6 M INNER SIZE WITH FLAG STONE COVER FOR WATERING SYSTEM FOR 18 NO EARTH PITS
16Costruction of retaining wall 1.5 M high as per site requirement
17Earthing of New 33/11 KV s/s (For black cotton soil) (Neutral+Body+Pole+LA)(4 earth=1 Set) using Galvanized mild steel flats (50x6 mm.) for connections, GI pipes 40 mm., (3 mtr. Each pipe), Bentonite powder, along with 3 mtrs.(Galvanized) 25 mm rod (single spike/earth rod distributed for mesh formation)
18Earthing of Station Transformer (For Murrum soil)(Neutral+Body+Pole+LA) (4 earth=1 Set)
19Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
20Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.-All kinds of soil
21Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.:-All kinds of soil
22Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
23Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling:-With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
24Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. Note : 1) Excess/less cement used than specified in this item is payable/ recoverable separately.All works upto plinth level ::-M-15 grade plain cement concrete (cement content considered @ 240 kg/cum)
25Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork
26Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply
27Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply
28Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply
29Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. using shuttering ply
30Providing and laying in position ready mixed concrete manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of RMC from transit mixer to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per the direction of Engineer-in-Charge. (Note :- Cement content considered in this item is @ 418 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).Reinforced cement concrete grade M-25 using 418 kg of cement per cum.-All works upto plinth level
31Providing and laying in position ready mixed concrete manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of RMC from transit mixer to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per the direction of Engineer-in-Charge. (Note :- Cement content considered in this item is @ 418 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).Reinforced cement concrete grade M-25 using 418 kg of cement per cum.-All works upto Floor five level
32Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level..-Thermo-Mechanically Treated bars of grade Fe-500D or more
33Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.:-Thermo-Mechanically Treated bars of grade Fe-500D or more
34First class brick work in foundation and plinth including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ).
35First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ).
36Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ).
37Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 275mm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters & with handles, hold fast including embedding in cement concrete of required grade required for fixing in position, all necessary fittings, including applying of approved steel primer etc. complete as required:-80x0.90 mm M.S. laths with 0.90 mm thick top cover.
38Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :Sal Wood
39Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement :
40Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veeners on both faces of shutters.:-35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
41Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured):-Rectangular or square.
42Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality).
43Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :250 x 10 mm
44Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :150x10 mm
45Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
46Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19×19mm MS square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame . The door frame to be fixed to the wall usuing MS screws of 65/100 mm size complete as per manufacturers' specification and direction of Engineer-In-Charge.
47Providing and fixing to existing door frames-30mm thick factory made solid both side prelam panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles, top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture . M.S. frame covered with 5mm thick heat moulded prelam PVC ‘C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, button and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, panelling of 5mm thick both side Prelam PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together
48Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete.152x42x18 mm weighing not less than 60 gms.
4912 mm cement plaster of mix:-Cement mortar 1:4 (1 cement : 4 fine sand)
5015 mm cement plaster on the rough side of single or half brick wall of mix:-Cement mortar 1:4 (1 cement : 4 fine sand)
516 mm cement plaster of mix :-Cement mortar 1:4 (1 cement : 4 fine sand)
52Neat cement punning
53Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]
54Finishing walls with water proofing cement paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :-New work ( two or more coats applied @ 3.84 kg/10 sqm)
55Applying priming coat [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :-With ready mixed Pink or Grey primer of approved brand and manufacture on wood work ( hard & soft wood ).
56Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:-Two or more coats on new work
57Providing and laying 1st class quality ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. all complete as per direction of the Engineer in-charge.Mat Finish Tiles/ Anti-skid Tiles/ Glossy Tiles600 mm x 600 mm in all shades and designs 1st class quality ceramic floor Porcelain tiles
58Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-incharge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge.450 mm X 300 mm in all shades and design
5962 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. all complete as per direction of Engineer-in-charge.
60Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.40 mm nominal outer dia .Pipes.
61Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.20 mm nominal outer dia .Pipes.
6225 mm nominal outer dia .Pipes.
6332 mm nominal outer dia .Pipes.
64Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):25 mm nominal bore
6532 mm nominal bore
6640 mm nominal bore
67Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid.
68Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
69Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
70Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm
71Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe40 mm dia
72Providing and fixing toilet paper holder :-C.P. brass
73Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.:-15 mm nominal bore
74Providing and Fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
75Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Single socketed pipe - 75 mm OD
76Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Single socketed pipe - 100 mm OD
77Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Single pushfit Coupler75 mm
78Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Single pushfit Coupler110 mm
79Single equal tee without door:75x75x75 mm
80Single equal tee without door:110x110x110mm
81Bend 87.5°:75 mm dia
82Bend 87.5°: 110 mm dia
83Plain shoe:75 mm dia
84Plain shoe:110 mm dia
85Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water, soil, waste & vent pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.75 mm dia
86Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water, soil, waste & vent pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.110 mm dia
87Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors:100 mm inlet and 75 mm outlet.Sand Cast Iron S&S as per IS- 1729.
88Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineer­in­charge. (Glazing and paneling and dash fasteners to be paid for separately) :-For fixed portion of approved quality:-Polyester powder coated aluminium ( minimum thickness of polyester powder coating of 50 micron ).
89For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):-Polyester powder coated aluminium ( minimum thickness of polyester powder coating of 50 micron ).
90Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :-With float glass panes of 8 mm thickness ( weight not less than 20 kg / sqm )
911000 LITER P/F SINTEX OVERHEAD TANK & GI PIPE (WITH LENGTH OF 125 MTRS) FITTING FOR WATER SUPPLY INCLUDING WATER TAP(17 NO.) NEAR TRANSFORMER NEUTRAL EARTHING
92PROVIDING AND FIXING 5HP SUBMERSIBLE PUMP
93Furniture for control room Table 600mmx 900mm- 1no., Chair- 3no., Computer table 1no. (Godrej or equivalent )
94VRLA Battery Set 110 Volt, 300 AH
95Sub station Battery charger 300 AH, 110 Volt
96110 V DC Distribution Boaed
97Supply, installation, testing & commissioning of wall mounted A.C. Sub distribution board (ACDB-2), comprising of 200 A MCCB I/C, PIL, 200/5A CT (3 Nos.) A+AS, V+VS, Outgoing- 32A TPN MCB 2 Nos., 63A TPN MCB 2 Nos, 16A SPN MCB 9 Nos.
98Fire extinguisher ABC Type 6 Kg
99Sand buckets 2 Nos. on each earth stand with canopy
100First Aid Boxes
10133 KV Hand Gloves
10211 KV Hand Gloves
103Earth Discharge Rod -33 KV
104Rubber Mat for 33 KV 6 x 4 feet (Thickness as per IS 15652)
105Insulation Tester (Megger Make) 5000 VA
106Earth Tester
107Mili Amp AC Clamp Meter (make Motwani)
108Digital Multimeter
109H- BEAM 11 METER 152 X 152 MM 37.1 KG/METER = 408.1 kg
110DC.CROSS ARMS 8` CENTRE TO CENTRE 100X50X6 MM CHANNEL (each weight-26.32 Kg) (ONE SET FOR FEEDER AND ONE SET FOR ISOLATOR/ME)
111Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg)
112HORIZONATAL & CROSS BRACING 8' CENTRE (wt of each X-BRACING-64.29 Kg
113Back Clamp suitable for H-Beam (MS Flat 65x8 mm)- each weight 1.92 Kg
11433 KV Polymer composite 70 KN Disc Insulator
11533 KV Strain hardware (T&C type) fittings
11633 KV 900 mm CD Polymer Composite pin insulator
117Stay set 20 mm. complete without Stay wire (Hot Dipped galvanized)
118Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg)
119STAY WIRE 7/4.00 MM.(7/8 SWG)(8.5 kg./stay)
120Stone Block/Pre cast block for base pedding 450x450x75mm
121CONCRETING (1:3:6) OF H-BEAM @ 0.7 CMT.PER POLE INCLUDING muffing
122CONCRETING (1:3:6) OF STAY @ 0.3 CMT. PER STAY (20MM)
123EARTHING COIL OF 115 TURNS OF 50 MM.DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE
124H- BEAM 9 METER 152 X 152 MM 37.1 KG/METER = 333.9 kg. FOR 33KV GANTRY STRUCTURE
125H- BEAM 9 METER 152 X 152 MM 37.1 KG/METER = 333.9 kg. FOR 11KV GANTRY STRUCTURE
126H- BEAM 7 METER 152 X 152 MM 37.1 KG/METER = 259.7 kg. FOR 5' CENTER JUMPER SUPPORT FOR 33 & 11KV SIDE
127D.C. CHANNEL 4.8 MTR CENTRE 100X50X6MM FOR 33KV BUS BAR (each weight-99.90 Kg)
128D.C. CHANNEL 4.8 MTR CENTRE 100X50X6MM FOR 11KV BUS BAR (each weight-99.90 Kg)
129D.C.cross- arm of 100 X 50 X 6 mm. ISMC channel suitable for 5' centre (65.09 kg each)
130Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg)
131STRAIN PLATE (IS Angle MS FLAT 65X8X250MM) 0.65 Kg each
132ACSR PANTHER CONDUCTOR 0.20 SQ. INCH (200 SQ.MM AL.EQ.)
13333 KV 900 mm CD Polymer Composite pin insulator
13433 KV Top clamps 75x75x6 mm Angle ( each weight 3.58 Kg)
13511 KV, 5KN PIN COMPOSITE POLYMER INSULATOR
13611 KV TOP CLAMPS 65X65X6MM ANGLE TYPE (each weight-3.0 Kg)
13733 KV Polymer composite 70 KN Disc Insulator
13833 KV COMPOSITE POLYMER STRAIN SET WITH HARD WARE SUITABLE FOR PANTHER CONDUCTOR (FOR 33KV SIDE)
13933 KV , 45 KN 16mm FRP with 25mm per KV Creepage DISC POLYMER LONG ROD TYPE T&C INSULATOR (FOR 11KV SIDE)
14033 KV COMPOSITE POLYMER STRAIN SET WITH HARD WARE SUITABLE FOR PANTHER CONDUCTOR (FOR 11KV SIDE)
141Stone Block/Pre cast block for base pedding 450x450x75mm
142CONCRETING (1:3:6) OF H-BEAM @ 0.70CMT.PER POLE INCLUDING muffing
143H- BEAM 11 METER 152 X 152 MM 37.1 KG/METER = 408.1 kg
144DC.CROSS ARMS 8` CENTRE TO CENTRE 100X50X6 MM CHANNEL (each weight-56.32 Kg)
14511 KV, 5KN PIN COMPOSITE POLYMER INSULATOR
14611 KV STRAIN HARDWARE (T&C TYPE) FITTINGS
147HORIZONATAL & CROSS BRACING 8' CENTRE (wt of each X-BRACING-64.29 Kg
148Back Clamp suitable for H-Beam (MS Flat 65x8 mm)- each weight 1.92 Kg
149Stay set 20 mm. complete without Stay wire (Hot Dipped galvanized)
150Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg)
151Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set )
152Stone Block/Pre cast block for base pedding 450x450x75mm
153CONCRETING (1:3:6) OF H-BEAM @ 0.70 CMT.PER POLE INCLUDING muffing
154CONCRETING (1:3:6) OF STAY @ 0.3 CMT. PER STAY (16MM)
155EARTHING COIL OF 115 TURNS OF 50 MM.DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE
156BIS certified Energy Efficiency Level-III (Old)/Level-II (New) 33/0.433KV, 63 KVA Distribution Transformer (As per IS 1180 latest amendment)
157DC.CROSS ARMS 8` CENTRE TO CENTRE 100X50X6 MM CHANNEL (each weight-26.32 Kg)
158Clamp A type 65x8mm of MS Flat for R.S. Joist(175x85mm)
15911 KV, 45 KN DISC T&C COMPOSITE POLYMER LONG ROD INSULATOR
16011 KV STRAIN HARDWARE (T&C TYPE) FITTINGS
1619 KV Gapless type LA ( 5KA) Polymer for DTR
162D.O.MOUNTING CHANNEL 75X40X6MM (each wt 19.37 Kg)
16311 KV Drop out Fuse (Porcelin)
164TRANSFORMER MOUNTING CHANNEL 100X50X6MM (each wt 52.63 Kg)
165TRANSFORMER CLAMPING SET 50X50 X6 MM ANGLE 460MM LONG (each wt 52.63 Kg)
166ACSR Rabitt 50 sqmm
167DANGER BOARD ENAMELED 11 KV
168L.T.DISTRIBUTION BOX FOR 63 KVA TRANSFORMER (200 A. ISOLATOR & 6 SP MCCB OF 90 A.) made of SMC
169DANGER BOARD ENAMELED 11 KV
170L.T.DISTRIBUTION BOX FOR 63 KVA TRANSFORMER (200 A. ISOLATOR & 6 SP MCCB OF 90 A.) made of SMC
171XLPE LT 1 - CORE ALUMINIUM UNARMOURED 70 SQMM CABLE
172XLPE LT 1 - CORE ALUMINIUM UNARMOURED 120 SQMM CABLE
173Stone Block/Pre cast block for base pedding 450x450x75mm
174CONCRETING (1:3:6) OF H-BEAM @ 0.6 CMT.PER POLE INCLUDING BASE PEDDING
17533/11 KV Power transformer , OFTC Type , 3150 KVA (Loss 3+15 KW)
176Supply Installation and Commissioning of Indoor 33 KV 1200Amp 4 Panel VCB Breaker Panel (Including One Incomer & Three Outgoing) with inbuilt Line CT, PT, Power Pack and Transmission Line Protection Protection for I/C panel & 1 no O/G panel and Transformer protection for 2 O/G panel etc all complete as per approved drawing
17711 KV 630 Amp, 25kA Indoor VCB Panel Complete with CT PT, Relays etc. all accessories
17811 KV 1000 KVAR AUTO SWITCH CAPACITOR BANK INCLUDING ASSOCIATED EQUIPMENTS SUCH AS 11 KV VACUUM CIRCUIT BREAKER, CONTROL PANEL, 11 KV OUTDOOR CURRENT TRANSFORMER WITH ADEQUATE METERING & PROTECTION CLASS OF SERVICE, BUS & EQUIPMENT ISOLATORS WITH EARTH SWITCH, MATCHING RVT, SUITABLE GAPLESS LIGHTENING ARRESTORS, NECESSARY CABLES FOR SUCCESSFUL COMMISSIONING COMPLETE
17911 KV Under-Ground XLPE armoured Cable 3X120 Sq.mm.
180Indoor heat shrinkable cable end jointing kit with lugs for 11 kV grade XLPE cable for 3 core 120 sq mm
18133 KV ISOLATOR 630 A.
18211 KV ISOLATOR 800 Amp
18333 KV LA POLYMER TYPE GAPLESS /METAL OXIDE SUBSTATION TYPE
18411 KV LA POLYMER TYPE GAPLESS /METAL OXIDE SUBSTATION TYPE
18533 KV / 0.11 kv SINGLE PHASE PTS OIL IMMERSED, outdoor with marshling box
18611 KV / 0.11 kv SINGLE PHASE PTS OIL IMMERSED, outdoor with marshling box
187For substation metering- 3 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HT trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible ) modems,
188SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB
189COPPER CONTROL CABLE 12 CORE, 2.5 SQMM PVC UNARMOURED
190COPPER CONTROL CABLE 8 CORE, 2.5 SQMM PVC UNARMORED
191COPPER CONTROL CABLE 4 CORE, 2.5 SQMM PVC UNARMOURED
192COPPER CONTROL CABLE 2 CORE, 2.5 SQMM PVC UNARMOURED
193T CLAMP ALUMINUM FOR BUS BAR PANTHER RUN PANTHER TAP
194BIMETALLIC CLAMPS FOR POWER TRANSFORMER 11KV SIDE
195PVC CABLE 2 CORE ARMOURED 2.5 SQMM ALUMINIUM CONDUCTOR
196PVC CABLE 4 CORE ARMOURED 16 SQMM ALUMINIUM CONDUCTOR
197M S BOLT WITH NUT 16X250 MM
198M S BOLT WITH NUT 16X200 MM
199M S BOLT WITH NUT 16X165 MM
200M S BOLT WITH NUT 16X140 MM
201M S BOLT WITH NUT 16X90 MM
202M S BOLT WITH NUT 16X40 MM
203RED-OXIDE PAINT
204ALUMINUM PAINT
205DANGER BOARD ENAMELED 33 KV AND 11 KV
20611 KV new Line inside Dhajnagar IE up to 1.6KM
207Line supports Full GI MS Tubular Pole 11 m Long
20811 KV 'V' cross-arms 75x75x6 mm MS Angle -each weight 24.60 Kg
209Back Clamp (MS Flat 65x8 mm) - each wt 1.92 Kg
21011 KV Top clamps 75x75x6 mm Angle ( each weight 3.58 Kg)
21111 KV Single Pole Cut Point Channal (100x50x6mm MS Channel) 1.65 mtr Long
21211 KV Side cross arm (100x50x6mm MS Channel)
213Earthing Coil ( coil of 115 turns of 50 mm.dia. and 2.5 Mtrs. lead of 4.0 mm. G.I wire)
21411 KV Pin Insulator(Polymer) composite 10KN FRP Dia 33.5mm
215ACSR Weasel Covered conductor (50 sq.mm. Al.Eq.), 11 kv
216Jointing Sleeves suitable for 50Sq.mm. conductor
217HT kiosks complete
218Stay set 20 mm. painted complete with turn buckles
219Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set )
220Clamp (3.04 kg each)
221Stay Insulators 90X65mm
222Concreting of pole @ 0.9 cmt. per pole including muffing
223Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay
224Red oxide paint
225Aluminium paint
226Anti-climbing devices (Barbed wire 2.24 mm dia. 14 SWG)
227Danger Boards Enamalled Type 11KV
228Binding wire and tape
229M.S.Nuts and Bolts
230Dismentalling of 11 KV Network, Pole, fittings and Conductor: Existing Line for HT Consumers up to 0.7 KM
231Dismantling of 10 mtrs,11mtrs & 12mtrs length of steel Tubular Pole at any kind of soil,including excavation of earth,refilling the pit with soil upto the ground level,ramming and making complete in all respect.
232Dismantling of stay set from the earth complete with 19mmx1800mm long stay rod,anchor plate of size 300x300x8mm,thimble,turn buckle,7/3.15mm dia G.I. Standard stay wire and stain insulator etc. and making complete in all respet
233Dismantling of 11KV pin insulator along with pin
234Dismantling of Disc insulator set for 11KV line along with necessary fittings
235Dismantling of 3KM(Single Conductor) ACSR 6/1/4.10 mm dia RACOON including coiling etc. Complete as required
236Dismantling of Barbed wire (Anti climbing device) per pole
237Dismantling of 3KM (Single Conductor),10/8 SWG GI wire including coiling etc.Complete as required.
238Transport Charges from Site to TSECL Store
239Supply and Installation of 315 KVA, 11/0.4 KV DTR
240BIS certified Energy Efficiency Level-III (Old)/Level-II (New) 11/0.433KV, 315 KVA Distribution Transformer (IS 1180 latest Amendment)
241Full GI MS Tubular Pole 11 m Long
242D.c.cross-arm of 100 x50x 6 mm. 8' centre
24311 kv (45kn) 16mm frp with 25mm per kv creepage disc insulator polymer
24411kv strain hard ware fitting
24511 kv d.o. fuse & lightening arrestor mounting channel (75x 40 x 6 mm.)
246Back clamp for h-beam size-480 mm ,wt-1.92 kg using 65x8 ms flat
24711 kv d.o. fuse unit
2489 kv gapless type LA ( 5ka) polymer for dtr
249315KVA Transformer Base (R.C.C.) as per TSECL approved drawings
250Clamp for h-beam size- ,wt-3.2 kg using 65x8 ms flat
251Stay set 20 mm. painted complete with turn buckles
252Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set )
253Stone block/pre cast block for base pedding 450x450x75mm
254Concreting of h-beam @ 0.70 cmt. Per pole with muffing (1:3:6)
255Concreting of stay @ 0.2 cmt. Per stay (1:3:6)
256Acsr conductor rabbit for jumper
257Danger boards enamalled type 11kv
258Bi-metallic clamps Distribution Transformers Bushing HT side
259Bi-metallic clamps suitable for 12mm dia. stud LT side
260Anti climbing devices (barbed wire 2.24 mm dia (14 swg) (3.5 kg. Wire per pole)
261Red oxide paint
262Aluminium paint
263M.s.nuts and bolts
264Distribution box mounting channel (75x40x6 mm.)
265L.t. distribution box suitable for 315 kva transformer (without tpn switches) with mccb on incoming and pf units on outgoing side made of smc
266LT 300 sq.mm.,3.5 core xlpe armoured aluminium conductor cable
267LT Al Lugs 300 sqmm
26811 kV A.B. switch, 400amps with complete fitting.
269DTR S/s fencing (Total 37 feet running meter max.) of 6' height with chain link fencing on MS Angle(50x50x6mm) support 7 nos. 7' height.
270Earthing of DTR (G.I. Pipe 40 mm dia., 3m long)
271Supply and Installation of 200 KVA, 11/0.4 KV DTR
272BIS certified Energy Efficiency Level-III (Old)/Level-II (New) 11/0.433KV, 200 KVA Distribution Transformer(As per IS 1180, latest Amendment)
273Full GI MS Tubular Pole 11 m Long
274D.c.cross-arm of 100 x50x 6 mm. 8' centre
27511 kv (45kn) 16mm frp with 25mm per kv creepage disc insulator polymer
27611kv strain hard ware fitting
27711 kv d.o. fuse & lightening arrestor mounting channel (75x 40 x 6 mm.)
278Back clamp for h-beam size-480 mm ,wt-1.92 kg using 65x8 ms flat
27911 kv d.o. fuse unit
2809 kv gapless type LA ( 5ka) polymer for dtr
281Transformer mounting dc cross-arm 100 x 50 x6 mm. Channel
282Transformer belting with 50 x 50 x 6 mm.angle with two cross fixing channels
283Clamp for h-beam size- ,wt-3.2 kg using 65x8 ms flat
284Stay set 20 mm. painted complete with turn buckles
285Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set )
286Stone block/pre cast block for base pedding 450x450x75mm
287Concreting of h-beam @ 0.70 cmt. Per pole with muffing (1:3:6)
288Concreting of stay @ 0.2 cmt. Per stay (1:3:6)
289Acsr conductor rabbit for jumper
290Danger boards enamalled type 11kv
291Bi-metallic clamps Distribution Transformers Bushing HT side
292Bi-metallic clamps suitable for 12mm dia. stud LT side
293Anti climbing devices (barbed wire 2.24 mm dia (14 swg) (3.5 kg. Wire per pole)
294Red oxide paint
295Aluminium paint
296M.s.nuts and bolts
297Distribution box mounting channel (75x40x6 mm.)
298L.t. distribution box suitable for 200 kva transformer (without tpn switches) with mccb on incoming and pf units on outgoing side made of smc
299LT 185 sq.mm.,3.5 core xlpe armoured aluminium conductor cable
300LT Al Lugs 185 sqmm
30111 kV A.B. switch 400 amps with complete fitting.
302DTR S/s fencing (Total 37 feet running meter max.) of 6' height with chain link fencing on MS Angle(50x50x6mm) support 7 nos. 7' height.
303Earthing of DTR (G.I. Pipe 40 mm dia., 3m long)
304New LT Feeder with ABC 150 sq mm Cable
305Binding wire and tape
306M.S.Nuts and Bolts
307A.B Cable tension clamps (Galvanized)
308Suspension Clamp with attachment
309Clamp for Neutral
310Piercing connector Type-I for single phase/three phase(Main 70-150 sq.mm. tape- of 50-95 sq.mm)
311Piercing connector Type-II (Main 70-150 sq.mm. tape- of 50-95 sq.mm)
3121100 Volts Grade Aerial bunched XLPE Cable 3 X 150 + 1 X 35 + 1 X 95 sq.mm. (insulated nuetral massenger)
313Feeder pillars complete
314Dismantling of LT line
315Dismentalling of LT Network, Conductor: Existing Line inside IE
316Dismantling of 7.5mtrs & 8mtrs length of P.C.C. Pole at any kind of soil ,including excavation of earth,refilling the pit with soil upto the ground level,ramming and making complete in all respect.
317Dismantling of MS angle Cross-Arm 1.0 to 1.6 Mtr long 65x65x6 mm
318Dismantling of C type bracket for LT 5-wire of 50x50x6mm/65x65x6mm
319Dismantling of Barbed wire(Anti climbing device) per pole
320Dismantling of stay set from the earth complete with 19mmx1800mm long stay rod,anchor plate of size 300x300x8mm,thimble turn buckle,7/3.15mm dia G.I standed stay wire and stain insulator etc. and making complete in all respect.
321Dismantling of 11KV Pin insulator along with Pin
322Dismantling of (Single Conductor) ACSR 6/1/4.10mm dia RACOON including coiling etc.Complete as required.
323Transport Charges from Site to TSECL Store
324Supply and Installation of Street Light LED Lamps on Street Light Poles
325Clamps / Arm Brackets / fixing arrangement for Street Light fittings suitable for LED Fixture
326Supply and Installation LED Lamp Fitting, for Street Light 100 Watt, with polycarbonate glass cover with IP66 enclosure and complete fittings and connection from Pole Junction Box
3273 Core 1.5 sq mm unarmoured Cable for Street Light connection
328Junction Box
329Supply and Laying of Street Light Cable 4 Core 16 sq mm armoured underground inside 32 mm MDPE Pipe pipe PN6
33032 mm HDPE Pipe pipe PN6 for laying of cable
331Supply and fixing of Post Top LED lamp in main gate with GI Pipe and loop box LED Lamp 120 Watt
332Timer Switch
333Excavation of soil 30cmX75cm for cable laying
334Route Survey
335Dismentalling of Street Light Network, Conductor, and Pole and fixtures & fittings: Existing Line inside IE
336Supply and Installation of High Mast Lighting
337Supply of 20 M high mast shaft suitable for 39 m/sec wind speed, with all accessories including foundation bolts, aviation light, feeder pillar & suitable as per illumination design Wiring material,power cables between panel and mast, MCB in base compartment are not included & shall be in the scope of erection.
338Supply of non-integral LED floodlight luminaries upto 250 Watts, 8 No. in each pole HPI/T Plus lamps and its control gear boxes.
339Provision of GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. (2nos per mast required)
340Power and Control Panel Outdoor and Environment Protection
341Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour.
342Erection and Commissioning of the high mast with all wiring materials.
343Environment Management plan
344Testing of environmental parameter (Ambient Air Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-18 months of 2 locations, once a quarter (09 samples) of two sector/Component
345Testing of environmental parameter (Water Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-18 months of 2 locations, once a quarter (09 samples) of two sector/Component
346Testing of environmental parameter (Ambient Noise Level) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-18 months of 2 locations, once a quarter (09 samples) of two sector/Component
347Testing of environmental parameter (Soil Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-18 months of 2 locations, once a quarter (09 samples) of two sector/Component
348Testing of environmental parameter (Ambient Air Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of two sector/Component.
349Testing of environmental parameter (Water Quality) within IE through NABL/MoEFCC Accredited Laboratory.Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of two sector/Component.
350Testing of environmental parameter (Ambient Noise Level) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of two sector/Component.
351Testing of environmental parameter (Soil Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of two sector/Component.
352LOCATION: Sarasima Industrial Estate
353New 11 KV & LT Compolsite Line inside Sarasima IE up to 2KM
354Full GI Tubular Pole 11 m Long
35511 KV 'V' cross-arms 75x75x6 mm MS Angle -each weight 24.60 Kg
356Back Clamp (MS Flat 65x8 mm) - each wt 1.92 Kg
35711 KV Top clamps 75x75x6 mm Angle ( each weight 3.58 Kg)
35811 KV Single Pole Cut Point Channal (100x50x6mm MS Channel) 1.65 mtr Long
35911 KV Side cross arm (100x50x6mm MS Channel)
360Earthing Coil ( coil of 115 turns of 50 mm.dia. and 2.5 Mtrs. lead of 4.0 mm. G.I wire)
36111 KV Pin Insulator(Polymer) composite 10KN FRP Dia 33.5mm
362ACSR Weasel Covered conductor (50 sq.mm. Al.Eq.), 11 kv
363Jointing Sleeves suitable for 100Sq.mm. conductor
364Stay set 20 mm. painted complete with turn buckles
365Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set )
366Clamp (3.04 kg each)
367Stay Insulators 90X65mm
368Concreting of pole @ 0.9 cmt. per stay including muffing
369Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay
370Red oxide paint
371Aluminium paint
372Anti-climbing devices (Barbed wire 2.24 mm dia. 14 SWG)
373Danger Boards Enamalled Type 11KV
374Binding wire and tape
375M.S.Nuts and Bolts
376A.B Cable tension clamps (Galvanized)
377Suspension Clamp with attachment
378Clamp for Neutral
379Piercing connector Type-I for single phase/three phase(Main 70-150 sq.mm. tape- of 50-95 sq.mm)
380Piercing connector Type-II (Main 70-150 sq.mm. tape- of 50-95 sq.mm)
3811100 Volts Grade Aerial bunched XLPE Cable 3 X 150 + 1 X 35 + 1 X 95 sq.mm. (insulated nuetral massenger)
382Route Survey of existing line and proposed network
383Replacement of old 11 KV Weasel conductor by covered weasel conductor up to 1.5KM
38411 KV Pin insulator Polymer Composite (5KN) FRP dia 24mm
385ACSR Conductor Weasel Coveredwith 3 % Sag
386Jointing Sleeves suitable for 80 Sq. mm.Al.
387Painted Stay set 20 mm. complete with turn buckles
388Stay wire 7/4.0 mm. (10 kg.stay wire per stay set )
389Clamp suitable ( each weight 3.2 kg ms flat 65x8mm)
390Red oxide paint
391Aluminium paint
392Anti-climbing devices (Barbed wire 2.24 mm dia. 14 SWG)
393Danger Boards Enamalled Type 11KV
394Binding wire and tape
395M.S.Nuts and Bolts
396A.B Cable tension clamps (Galvanized)
397Suspension Clamp with attachment
398Clamp for Neutral
399Piercing connector Type-I for single phase/three phase(Main 70-150 sq.mm. tape- of 50-95 sq.mm)
400Piercing connector Type-II (Main 70-150 sq.mm. tape- of 50-95 sq.mm)
4011100 Volts Grade Aerial bunched XLPE Cable 3 X 150 + 1 X 35 + 1 X 95 sq.mm. (insulated nuetral massenger)
402Route Survey of existing line and proposed network
403Dismentalling Cost
404Construction of 11 KV Bay at 33/11 KV Sarasima Town SS
405Supply of 11 KV vacuum circuit breaker(VCB) with control and relay panel (incoming), simplex type 800A continuous current rating, 250 MVA rupturing capacity with manual and motorised spring closing mechanism,electrical closing and opening arrangement and internal panel wiring with provisions of 2-over current & 1-earth fault combined relay, auxiliary relays, 1-Voltmeter, 3-Ammeter, 1 - CT operated static tri-vector meter(TVM). CTR = 300/ 1-1-0.577. PTR = 11000/√3 / 110/√3.
406Design, engineering, supply, testing and commissioning of 11 kv adapter panel for 1250 ampwith allied accessories and cables
40711 kv.c.ts.(outdoor dry type) 300-150/5 amps
40811 KV Control & Relay Panel for 11 KV Outdoor VCB with IEC 61850 compliant differential relay, numerical type with static TVM
40911 kv isolator 800 a.(turn & twist type)
41011 kv la polymer type gapless /metal oxide 9 kv , 10 ka substation type
41111 kv single phase pts oil immersed
412For substation metering- 3 phase 4 wire 3x63.5 volts lb=5 amps imax = 10 amp, ht trivector meter class of accuracy 0.5s, dlms compliant category a meters along with gsm (gprs compatible ) modems,
413Sheet metal meter box suitable for h.t. static travector meters with ttb
414Copper control cable 12 core, 2.5 sqmm pvc unarmoured
415Copper control cable 8 core, 2.5 sqmm pvc unarmored
416Copper control cable 4 core, 2.5 sqmm pvc unarmoured
417Copper control cable 2 core, 2.5 sqmm pvc unarmoured
418T clamp aluminum for bus bar panther run panther tap
419Bimetallic clamps for power transformer 11kv side
420H- beam 9 meter 152 x 152 mm 37.1 kg/meter = 333.9 kg. For 33kv gantry structure
421D.c. channel 4.8 mtr centre 100x50x6mm for 33kv bus bar (each weight-99.90 kg)
422Clamp suitable for 152 x 152 mm., 37.1 kg./mtr h-beam ( each weight 3.2 kg)
423Strain plate (IS MS flat 65x8x250mm) 0.65 kg each
424Acsr panther conductor 0.20 sq. Inch (200 sq.mm al.eq.)
42511 kv, 5kn pin composite polymer insulator
42611 kv top clamps 65x65x6mm angle type (each weight-3.0 kg)
42711 kv , 45 kn 16mm frp with 25mm per kv creepage disc polymer long rod type t&c insulator (for 11kv side)
42811 kv composite polymer strain set with hard ware suitable for panther conductor (for 11kv side)
429Stone block/pre cast block for base pedding 450x450x75mm
430Concreting (1:3:6) of h-beam @ 0.70cmt.per pole including muffing
431Concreting (1:3:6) of vcb structures 3.5 cmt per vcb
432Concreting (1:3:6) of isolator support structure @ 0.1 cmt. Per structure
433M s bolt with nut assorted size
434Red-oxide paint
435Aluminum paint
436CO2 Fire Extinguisher (6Kg) Dry Type
437Shock Treatment Chart
438Sand buckets 2 Nos. on each earth stand with canopy
439First Aid Boxes
44011 KV Hand Gloves
441Earth Discharge Rod -132 KV (ES-132 BEIMCO)
442Earth Discharge Rod -11 kv
443Meggar 5000 VA
444Earth Tester
445Danger board enameled11 kv
446Under Ground Fault Detector
447Supply and Installation of 500 KVA (4 No.s), 11/0.4 KV DTR at Sarasima IE
448BIS certified Energy Efficiency Level-III (Old)/Level-II (New), 11/0.433KV, 500 KVA Distribution Transformer (As per IS 1180 Latest Amendment)
449H-beams 152 x 152 mm., 37.1 kg./mtr.-11 mtr. Long = 408.1 kg
450D.c.cross-arm of 100 x50x 6 mm. 8' centre
451Clamp for h-beam size-800 mm ,wt-3.2 kg using 65x8 ms flat
45211 kv (45kn) 16mm frp with 25mm per kv creepage disc insulator polymer
45311kv strain hardware fitting
45411 kv d.o. fuse & lightening arrestor mounting channel (75x 40 x 6 mm.)
455Back clamp for h-beam size-480 mm ,wt-1.92 kg using 65x8 ms flat
45611 kv d.o. fuse unit
4579 kv gapless type ( 5ka) polymer for dtr
458Transformer mounting dc cross-arm 100 x 50 x6 mm. Channel
459Transformer belting with 50 x 50 x 6 mm.angle with two cross fixing channels
460Clamp for h-beam size- ,wt-3.2 kg using 65x8 ms flat
461Stay set 16 mm. Painted complete with turn buckles
462Stay wire 7/3.15 mm. (7.5 kg.stay wire per stay set )
463Clamp for h-beam size- ,wt-3.2 kg using 65x8 ms flat
464Stone block/pre cast block for base pedding 450x450x75mm
465Concreting of h-beam @ 0.70 cmt. Per pole with muffing (1:3:6)
466Concreting of stay @ 0.2 cmt. Per stay (1:3:6)
467Acsr conductor rabbit for jumper
468Danger boards enamalled type 11kv
469Bi-metallic clamps Distribution Transformers Bushing HT side
470Bi-metallic clamps suitable for 12mm dia. stud LT side
471Anti climbing devices (barbed wire 2.24 mm dia (14 swg) (3.5 kg. Wire per pole)
472Red oxide paint
473Aluminium paint
474M.s.nuts and bolts
475Distribution box mounting channel (75x40x6 mm.)
476Back clamp for h-beam size- ,wt-1.92 kg using 65x8 ms flat
477L.t. distribution box suitable for 500 kva transformer (without tpn switches) with mccb on incoming and pf units on outgoing side made of smc
478LT 300 sq.mm.,3.5 core xlpe armoured aluminium conductor cable
479LT Al Lugs 300 sqmm
48011 kV A.B. switch 400 amps with complete fitting.
481DTR S/s fencing (Total 37 feet running meter max.) of 6' height with chain link fencing on MS Angle(50x50x6mm) support 7 nos. 7' height.
482Earthing of DTR (Neutral+Body+Pole+LA)(4 earth=1 Set)(G.I. Pipe 40 mm dia., 3m long)
483Supply and Installation of 315 KVA, 11/0.4 KV DTR
484BIS certified Energy Efficiency Level-III (Old)/Level-II (New) 11/0.433KV, 315 KVA Distribution Transformer(As per IS 1180 latest amendment)
485MS Steel Tubular Pole 11 m
486D.C.cross-arm of 100 X50X 6 mm. 8' centre
487Clamp using 65X8 Ms Flat
48811 KV (45KN) 16mm FRP with 25mm per KV creepage Disc Insulator Polymer
48911KV Strain hard ware fitting
49011 KV D.O. fuse & Lightening Arrestor mounting channel (75X 40 X 6 mm.)
491Back Clamp ,Wt-1.92 Kg using 65X8 Ms Flat
49211 KV D.O. fuse unit
4939 KV Gapless type ( 5KA) Polymer for DTR
494Transformer mounting DC cross-arm 100 X 50 X6 mm. channel
495Transformer belting with 50 X 50 X 6 mm.angle with two cross fixing channels
496Stay set 16 mm. painted complete with turn buckles
497Stay wire 7/3.15 mm. (7.5 kg.stay wire per stay set )
498Stone Block/Pre cast block for base pedding 450x450x75mm
499Concreting of pole @ 0.50 cmt. per pole with muffing
500Concreting of Stay @ 0.2 cmt. per stay
501ACSR Conductor Racoon conductor for jumper
502Danger Boards Enamalled Type 11KV
503Bi-metallic clamps Distribution Transformers Bushing HT side
504Bi-metallic clamps suitable for 12mm dia. stud LT side
505Anti climbing devices (Barbed wire 2.24 mm Dia (14 SWG) (3.5 Kg. wire per pole)
506Red oxide paint
507Aluminium paint
508M.S.Nuts and Bolts
509Distribution Box mounting channel (75x40x6 mm.)
510L.T. Distribution box suitable for 315 KVA transformer (without TPN switches) with MCCB on incoming and PF units on outgoing side made of SMC
511150 Sq.mm.,single core XLPE insulated un-armoured aluminium conductor cable
512300 Sq.mm.,single core XLPE insulated un-armoured aluminium conductor cable
51311 KV AB Switch, 400 Amp with Complete fitting
514Earthing of DTR (Neutral+Body+Pole+LA)(4 earth=1 Set) (G.I. Pipe 40 mm dia., 3m long)
515Supply and Installation of 200 KVA, 11/0.4 KV DTR
516BIS certified Energy Efficiency Level-III (Old)/Level-II (New) 11/0.433KV, 200 KVA Distribution Transformer(As per IS 1180 latest amendment)
517Full GI MS Tubular Pole 11 m Long
518D.C.cross-arm of 100 X50X 6 mm. 8' centre
519Clamp using 65X8 Ms Flat
52011 KV (45KN) 16mm FRP with 25mm per KV creepage Disc Insulator Polymer
52111KV Strain hard ware fitting
52211 KV D.O. fuse & Lightening Arrestor mounting channel (75X 40 X 6 mm.)
523Back Clamp ,Wt-1.92 Kg using 65X8 Ms Flat
52411 KV D.O. fuse unit
5259 KV Gapless type ( 5KA) Polymer for DTR
526Transformer mounting DC cross-arm 100 X 50 X6 mm. channel
527Transformer belting with 50 X 50 X 6 mm.angle with two cross fixing channels
528Stay set 16 mm. painted complete with turn buckles
529Stay wire 7/3.15 mm. (7.5 kg.stay wire per stay set )
530Stone Block/Pre cast block for base pedding 450x450x75mm
531Concreting of pole @ 0.50 cmt. per pole with muffing
532Concreting of Stay @ 0.2 cmt. per stay
533ACSR Conductor Racoon conductor for jumper
534Danger Boards Enamalled Type 11KV
535Bi-metallic clamps Distribution Transformers Bushing HT side
536Bi-metallic clamps suitable for 12mm dia. stud LT side
537Anti climbing devices (Barbed wire 2.24 mm Dia (14 SWG) (3.5 Kg. wire per pole)
538Red oxide paint
539Aluminium paint
540M.S.Nuts and Bolts
541Distribution Box mounting channel (75x40x6 mm.)
542L.T. Distribution box suitable for 200 KVA transformer (without TPN switches) with MCCB on incoming and PF units on outgoing side made of SMC
543150 Sq.mm.,single core XLPE insulated un-armoured aluminium conductor cable
544300 Sq.mm.,single core XLPE insulated un-armoured aluminium conductor cable
54511 KV AB Switch, 400 Amp with Complete fitting
546Earthing of DTR (Neutral+Body+Pole+LA)(4 earth=1 Set) (G.I. Pipe 40 mm dia., 3m long)
547Supply and Installation of Street Light LED Lamps on Street Light Poles
548Full GI MS Tubular Pole 11 m Long
549Concreting of pole @ 0.50 cmt. per pole with muffing
550Earthing Coil ( coil of 115 turns of 50 mm.dia. and 2.5 Mtrs. lead of 4.0 mm. G.I wire)
551Supply and Installation LED Lamp Fitting, for Street Light 100 Watt, with polycarbonate glass cover with IP66 enclosure and complete fittings and connection from Pole Junction Box
552Clamps / Arm Brackets / fixing arrangement for Street Light fittings suitable for LED Fixture
5533 Core 1.5 sq mm unarmoured Cable for Street Light connection
554Junction Box
555Supply and Laying of Street Light Cable 3-1-2 Core 16 sq mm armoured underground inside 32 mm MDPE Pipe pipe PN6
55632 mm MDPE Pipe pipe PN6 for laying of cable
557Supply and fixing of Post Top LED lamp in main gate with GI Pipe and loop box LED Lamp 120 Watt
558Excavation for cable laying
559Route Survey
560Supply and Installation of High Mast Lighting
561Supply of 20 M high mast shaft suitable for 39 m/sec wind speed, with all accessories including foundation bolts, aviation light, feeder pillar & suitable as per illumination design Wiring material,power cables between panel and mast, MCB in base compartment are not included & shall be in the scope of erection.
562Supply of non-integral floodlight luminaries LED 250 Watts, 8 No. in each pole HPI/T Plus lamps and its control gear boxes.
563Provision of GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. (2nos per mast required)
564Power and Control Panel Outdoor and Environment Protection
565Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour.
566Erection and Commissioning of the high mast with all wiring materials.
567Environment Management plan
568Testing of environmental parameter (Ambient Air Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-12 months of 2 locations, once a quarter (06 samples) of two sector/Component.
569Testing of environmental parameter (Water Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-12 months of 2 locations, once a quarter (06 samples) of two sector/Component.
570Testing of environmental parameter (Ambient Noise Level) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-12 months of 2 locations, once a quarter (06 samples) of two sector/Component.
571Testing of environmental parameter (Soil Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Construction phase-12 months of 2 locations, once a quarter (06 samples) of two sector/Component.
572Testing of environmental parameter (Ambient Air Quality) within IE through NABET Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of four sector/Component of two sector/Component
573Testing of environmental parameter (Water Quality) within IE through NABET Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of two sector/Component
574Testing of environmental parameter (Ambient Noise Level) within IE through NABET Accredited Laboratory.Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of two sector/Component
575Testing of environmental parameter (Soil Quality) within IE through NABET Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 1 location, once in 6 months (10 samples) of two sector/Component
576Operation & Maintaince-TSECL Work
577For Dhajanagar Industrial Estate
578For Sarasima Industrial Estate Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57717849
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 28-10-2026
Authority
Authority Name Tripura Industrial Development Corporation Limited
Work Description Tender for Infrastructure Development Of Industrial Estate In Tripura/ Sh: Power And Electrical - Tsecl Work Etc. At Dhajanagar And Sarasima Industrial Estates (Adb Project/ Package :14)
Basic Detail
Tender No 19/TIDC/ENGG/PNIeT/2026-27,
Bidding Type Tender
Location
City Gomati
State Tripura
Key Dates
Publish Date 25 Sep 2026
Submission Date 28 Oct 2026
Open Date 28 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee 10000
EMD 11.27 Lakhs
Exemption Not Available
Document List
AnnexureIGCCC.pdf
AnnexureIIIDDRDhajanagar.pdf
AnnexureIIieeReportDhajanagarIE.pdf
AnnexureIIieeReportSarasimaIE.pdf
AnnexureIIIRPSarasima.pdf
AnnexureIVQAQCAppendix.pdf
BOQ_78580.xls
c863da1f-9ec1-4261-b51f-71badcaaf373.html
DajanagarAndSarasimaDrawing.pdf
SBDPkg14.pdf
Tendernotice_1 (34).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Oct 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
pdf

AnnexureIGCCC.pdf

pdf

AnnexureIIIDDRDhajanagar.pdf

pdf

AnnexureIIieeReportDhajanagarIE.pdf

pdf

AnnexureIIieeReportSarasimaIE.pdf

pdf

AnnexureIIIRPSarasima.pdf

pdf

AnnexureIVQAQCAppendix.pdf

xls

BOQ_78580.xls

html

c863da1f-9ec1-4261-b51f-71badcaaf373.html

pdf

DajanagarAndSarasimaDrawing.pdf

pdf

SBDPkg14.pdf

pdf

Tendernotice_1 (34).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender