Tender For Infrastructure Development Of Industrial Estate In Tripura/ Sh: Power And Electrical-Tsecl Work Etc.At Bodhjungnagar Industrial Estate (Adb Project/Package :11)
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Oct 2026
20 days left
EMD
51.28 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Infrastructure Development Of Industrial Estate In Tripura/ Sh: Power And Electrical-Tsecl Work Etc.At Bodhjungnagar Industrial Estate (Adb Project/Package :11)
BOQ
| Sl. No. | Item Description |
| 1 | Supply,Installation,Erection for Laying of new 33 KV 1Cx185 sq. mm. XLPE UG Cable 33 KV Feeder up to 3KM |
| 2 | Supply of 1 Core 33 KV XLPE 185 sqmm Al Power Cable (1 Run for each phase and 1 Run spare, Total 4 Run 1Cx185 Sq mm) |
| 3 | Laying of 1 Core 33 KV XLPE 185 sqmm Al Power Cable in trench 350 mm X 1200 mm, Sand cushioning 250X350 sqmm, Brick protection 120 sqmm |
| 4 | Excavation of cable entry pit through hdpe pipe pe80 pn 6, 400 mm od |
| 5 | Supply and erection of p80. Pn6, 400 mm od hdpe pipe |
| 6 | Gi / hdpe pipe for raiser up to 400 sqmm |
| 7 | Coiling of excess 185 sqmm Cable in pit size 2250 X 2250 sqmm minimimum by brick laying and 300 mm fine sand for 10 locations |
| 8 | Outdoor cable termination with heat shrinkable jointing kit 185 sqmm |
| 9 | Route Marker complete with danger sign |
| 10 | 33 KV danger Plate |
| 11 | MS Nuts & Bolts assorted size |
| 12 | Bi metallic lugs 185 sqmm |
| 13 | HT Kiosks complete |
| 14 | 8 SWG GI Wire |
| 15 | 33 KV 3 Way RMU (36 KV Motorised Ring Main Unit self power type with CPT or by other means,Solod or SF6 Insulation Outdoor enclosure,with all accessories.) |
| 16 | Route Survey of existing line and proposed network |
| 17 | Supply,Installation,Erection and Laying of 33 KV 1Cx185 sq. mm. XLPE UG Cable 33 KV Feeder against Dismantling of OH Line up to 5KM with Dismantling of 33KV OH Rubber Park feeder |
| 18 | Dismantling of 10mtrs,11mtrs & 12mtrs length of Steel Tubular POLE at any kind of Soil,including excavation of earth,refilling the pit with soil upto the ground level,ramming and making complete |
| 19 | Dismantling of stay set from the earth complete with 19mmx1800mm long stay rod,anchor plate of size 300x300x8mm,thimble,turn buckle,7/3.15mm dia G.I. Standard stay wire and stain insulator etc. and making complete in all respet |
| 20 | Dismantling of 33KV pin insulator along with pin |
| 21 | Dismantling of Disc insulator set for 33KV line along with necessary fittings |
| 22 | Dismantling of 5KM(Single Conductor) ACSR 6/7/4.72/1.57 mm dia DOG including coiling etc. Complete as required |
| 23 | Dismantling of V Cross-Arm 65x65x6mm MS Angle/75x40x40x6mm MS Channel |
| 24 | Dismantling of V Cross-Arm,100x50x50x6mm MS Channel |
| 25 | Dismantling of Barbed wire (Anti climbing device) per pole |
| 26 | Dismantling of 5KM (Single Conductor),10/8 SWG GI wire including coiling etc.Complete as required. |
| 27 | Transport Charges from site to TSECL |
| 28 | UG Cable Supply & Laying |
| 29 | Supply of 1 Core 33 KV XLPE 185 sqmm Al Power Cable (1 Run for each phase and 1 Run spare, Total 4 Run 1Cx185 Sq mm) |
| 30 | Laying of 1 Core 33 KV XLPE 185 sqmm Al Power Cable in trench 350 mm X 1200 mm, Sand cushioning 250X350 sqmm, Brick protection 120 sqmm |
| 31 | Excavation of cable entry pit through hdpe pipe pe80 pn 6, 400 mm od |
| 32 | Supply and erection of p80. Pn6, 400 mm od hdpe pipe |
| 33 | Coiling of excess 185 sqmm Cable in pit size 2250 X 2250 sqmm minimimum by brick laying and 300 mm fine sand |
| 34 | Outdoor cable termination with heat shrinkable jointing kit 185 sqmm |
| 35 | Route Marker complete with danger sign |
| 36 | 33 KV danger Plate |
| 37 | MS Nuts & Bolts assorted size |
| 38 | Bi metallic lugs 185 sqmm |
| 39 | HT Kiosks complete |
| 40 | 8 SWG GI Wire |
| 41 | 33 KV 3 Way RMU (36 KV Motorised Ring Main Unit self power type with CPT or by other means,Solod or SF6 Insulation Outdoor enclosure,with all accessories.) |
| 42 | Route Survey of existing line and proposed network |
| 43 | Supply,Installtion,Erection and Laying of 33 KV 1Cx185 sq. mm. XLPE UG Cable 33 KV Feeder against replacement of OH Line for HT Consumers up to 6KM where Dismantling (2KM & 4KM) of 33KV OH line For HT Consumers(Tripura ISPAT & Dharampal Steel). |
| 44 | 33KV OH Dismantling |
| 45 | Dismantling of 10mtrs,11mtrs & 12mtrs length of Steel Tubular POLE at any kind of Soil,including excavation of earth,refilling the pit with soil upto the ground level,ramming and making complete |
| 46 | Dismantling of stay set from the earth complete with 19mmx1800mm long stay rod,anchor plate of size 300x300x8mm,thimble,turn buckle,7/3.15mm dia G.I. Standard stay wire and stain insulator etc. and making complete in all respet |
| 47 | Dismantling of 33KV pin insulator along with GI pin |
| 48 | Dismantling of Disc insulator set for 33KV line along with necessary fittings |
| 49 | Dismantling of 5KM(Single Conductor) ACSR 6/7/4.72/1.57 mm dia DOG including coiling etc. Complete as required |
| 50 | Dismantling of V Cross-Arm 65x65x6mm MS Angle/75x40x40x6mm MS Channel |
| 51 | Dismantling of V Cross-Arm,100x50x50x6mm MS Channel |
| 52 | Dismantling of Barbed wire (Anti climbing device) per pole |
| 53 | Dismantling of 5KM (Single Conductor),10/8 SWG GI wire including coiling etc.Complete as required. |
| 54 | Transport Charges from site to TSECL |
| 55 | UG Cable Supply & Laying up to 6KM |
| 56 | Supply of 1 Core 33 KV XLPE 185 sqmm Al Power Cable (1 Run for each phase and 1 Run spare, Total 4 Run 1Cx185 Sq mm) |
| 57 | Laying of 1 Core 33 KV XLPE 185 sqmm Al Power Cable in trench 350 mm X 1200 mm, Sand cushioning 250X350 sqmm, Brick protection 120 sqmm |
| 58 | Excavation of cable entry pit through hdpe pipe pe80 pn 6, 400 mm od |
| 59 | Supply and erection of p80. Pn6, 400 mm od hdpe pipe |
| 60 | Gi / hdpe pipe for raiser up to 400 sqmm |
| 61 | Coiling of excess 185 sqmm Cable in pit size 2250 X 2250 sqmm minimimum by brick laying and 300 mm fine sand |
| 62 | Outdoor cable termination with heat shrinkable jointing kit 185 sqmm |
| 63 | Route Marker complete with danger sign |
| 64 | 33 KV danger Plate |
| 65 | MS Nuts & Bolts assorted size |
| 66 | HT Kiosks complete |
| 67 | 8 SWG GI Wire |
| 68 | Route Survey of existing line and proposed network |
| 69 | Supply,Installation & Erection of Reconstruction of 33/11 KV Rubber Park S/s with 7.5 MVA Power Transformer & Dismantling of 5MVA. |
| 70 | Yard fencing with chain link mesh over RCC beam 2.4 mtr. Height |
| 71 | Boundary wall with RCC column and Brick work |
| 72 | MS SIGN BOARD, BAY INDICATION BOARD & RYB PHASE INDICATION BOARD |
| 73 | Yard Leveling by Kopra filling |
| 74 | Laying of Metal in yard by 100 mm thick metalling with 40 mm size B.T. Yard level to be increased by grouting Brick placed vertical 100 mm above of the ground and remaining part of the brick kept inside the ground |
| 75 | Procedure to avoid grass in sub-station yard- Black Cotton. By laying Gravels. |
| 76 | 7.5 MVA Transformer Base (Qty=1 Tr.)Concrete: 1:1.5:3 Ratio-5.634 cmt, concrete :1:5:8 Ratio-7.545 cmt., M.S. Flat/rod-324.87 kg and Base filling by Kopra in case of Black cotton soil 3.1*3.1*0.5m= 4.8 cmt]Base filling by Kopra -1.92 cmt., concreting, curing and back filling of pits. All complete works |
| 77 | Switch yard Equipment foundations including CT, PT, Isolator, LA etc |
| 78 | CONCRETING (1:3:6) OF VCB /SF6 STRUCTURES 3.5 cum per VCB / SF6 |
| 79 | Full GI Tubular Pole 11 m Long with 1.5m Arm Bracket |
| 80 | LED Yard Lighting 80 Watt Flood Light |
| 81 | PROVIDING & FIXING PERFORATED CABLE TRAY 300 MM WIDE & 2 MM THICK FIXED ON 45X45X5 MM M.S. ANGLE STAND GROUTED IN C.C 1:24 |
| 82 | PROVIDING AND FIXING EARTH PIT OF BRICK MASSONERY 0.6 X 0.6 M INNER SIZE WITH FLAG STONE COVER FOR WATERING SYSTEM FOR 18 Nos. EARTH PITS |
| 83 | Excavation of earth pit, putting cast iron pipe with flange on one end (as per ISS 7181/86) of Nos.minal dia 125 mm and 2.75 mtrs long inside the pit including supply and fixing RCC collars 0.75 mtr dia(OD) 50mm thick and 0.6 mtrs long inside the pit, back fill the pit in the 25 mm size granules of BH coke for full depth of the pit with alternate layers of BH coke and salt of 300 mm thick around the earth pipe of 150 mm on all the sides of the pipe including cost and conveyance of BH Coke,Salt,Clamps,CI pipes and RCC collars, labour charges for all operational and incidental items of work etc., complete and including cost of CI pipe. |
| 84 | 1000 LITER P/F SINTEX OVERHEAD TANK & GI PIPE (WITH LENGTH OF 125 MTRS) FITTING FOR WATER SUPPLY INCLUDING WATER TAP(17 Nos.) NEAR TRANSFORMER NEUTRAL EARTHING |
| 85 | PROVIDING AND FIXING 5HP SUBMERSIBLE PUMP |
| 86 | Furniture for control room Table 600mmx 900mm- 1Nos., Chair- 3Nos., Computer table 1Nos. (Godrej or equivalent ) |
| 87 | Marshelling box with 10 Nos. connectors 11KV |
| 88 | Fire extinguisher ABC Type 6 Kg |
| 89 | Sand buckets 2 Nos. on each earth stand with caNos.py |
| 90 | First Aid Boxes |
| 91 | 33 KV Hand Gloves |
| 92 | 11 KV Hand Gloves |
| 93 | Safety Helmet |
| 94 | Safety Shoes |
| 95 | Half Safety Belt |
| 96 | Portable Fire Extinguisher DCP-ABC Powder Type composite body (MFCF-Maintenance Free corrossion free,Powder-2Kg) |
| 97 | Earth Discharge Rod -33 KV |
| 98 | Rubber Mat for 33 KV, 6x4 ft, thickness as per IS 15652) |
| 99 | Insulation Tester (Megger Make) 5000 V |
| 100 | Earth Tester |
| 101 | Mili Amp AC Clamp Meter (make Motwani) |
| 102 | Digital Multimeter |
| 103 | Supply,Erection & Installation of DP Structure for 33 KV Incoming and Outgoing |
| 104 | Design, Engineering, manufacturing, Supply of SteelTubular Pole, ll.Omtr. Long (Designation 410: SP-54) (bottom portion hot dip galvanized ) conforming to ISS: 2713(P-I & ll)/1980 as amended up-to-date and other relevant IS with up-to-date amendments with base plate and as per technical specification of bid document. |
| 105 | Erection of 11.0 mtr. long Steel Tubular Poles (Designation 410: SP-54) ( bottom portion hot dip galvanized ) conforming to ISS: 2713 (P-l & ll)-1980 with base plate direct in earth including excavation, refilling and ramming etc. as required (l/6th length of the pole to be embedded in earth) and grouting with CC of ratio 1:3:6 (1 cement : 3 river sand : 6 jhama brick aggregate of 20 mm. Nos.minal size) ilc supply of cement, sand and brick aggregate complete with excavation, refilling of earth, ramming alongwith centering and shuttering as required (@> 0.273 Cum per Steel Tubular Pole as per TSECL specification) etc. and applying paints with ready mixed primer (two or more coats) and alluminium paint of approved quality to give an even shade etc. as required including carrying of poles from TSECL storeyardf M M Division, Agartala) to work site by mechnical transport/manual/handcart i/c loading unloading stacking as reqd. and as per direction of Eng-ln-Charge. |
| 106 | H- BEAM 11 METER 152 X 152 MM 37.1 KG/METER = 408.1 kg |
| 107 | DC.CROSS ARMS 8` CENTRE TO CENTRE 100X50X6 MM CHANNEL (each weight-26.32 Kg) (2 Nos. FOR FEEDER AND 2 Nos. FOR ISOLATOR/ME) |
| 108 | Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg) |
| 109 | HORIZONATAL & CROSS BRACING 8' CENTRE (wt of each X-BRACING-64.29 Kg |
| 110 | Back Clamp suitable for H-Beam (MS Flat 65x8 mm)- each weight 1.92 Kg |
| 111 | 33 KV Polymer composite 70 KN Disc Insulator |
| 112 | 33 KV Strain hardware (T&C type) fittings |
| 113 | 33 KV 900 mm CD Polymer Composite pin insulator |
| 114 | Stay set 20 mm. complete without Stay wire (Hot Dipped galvanized) |
| 115 | Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg) |
| 116 | STAY WIRE 7/4.00 MM.(7/8 SWG)(8.5 kg./stay) |
| 117 | CONCRETING (1:3:6) OF H-BEAM @ 0.7 CMT.PER POLE INCLUDING muffing |
| 118 | CONCRETING (1:3:6) OF STAY @ 0.3 CMT. PER STAY (20MM) |
| 119 | Erection of Earthing set as per ISS : 3043 of 1966 and with latest amendment if any, 2.5 mtr long G.l. pipe (ISI marked) of 40 mm diameter withsuitable holes on pipe circumference including a pair of clamps (made of 50 X 6 mm M.S. flat), galvanized nuts & bolts alongwith alternate layers of salt & charcoal including supply of 4.0 mtr long, 12mm dia PVC pipe for each earthing set etc. as required and as per direction of Engineer-in-charge. |
| 120 | Suppply,Installation & Erection for structures and bus-bar arrangements |
| 121 | H- BEAM 9 METER 152 X 152 MM 37.1 KG/METER = 333.9 kg. FOR 33KV GANTRY STRUCTURE |
| 122 | H- BEAM 9 METER 152 X 152 MM 37.1 KG/METER = 333.9 kg. FOR 11KV GANTRY STRUCTURE |
| 123 | H- BEAM 7 METER 152 X 152 MM 37.1 KG/METER = 259.7 kg. FOR 5' CENTER JUMPER SUPPORT FOR 33 & 11KV SIDE |
| 124 | D.C. CHANNEL 4.8 MTR CENTRE 100X50X6MM FOR 33KV BUS BAR (each weight-99.90 Kg) |
| 125 | D.C. CHANNEL 4.8 MTR CENTRE 100X50X6MM FOR 11KV BUS BAR (each weight-99.90 Kg) |
| 126 | D.C. Channel (3.8 mtrs) 100x50x6mm |
| 127 | D.C Cross-arm of 100x50x6mm ISMC channel suitable for 5' centre (65.09Kg) |
| 128 | Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg) |
| 129 | STRAIN PLATE (IS MS FLAT 65X8X250MM) 0.65 Kg each |
| 130 | Supply of ACSR PANTHER CONDUCTOR 0.20 SQ. INCH (200 SQ.MM AL.EQ.) |
| 131 | 33 KV 900 mm CD Polymer Composite pin insulator |
| 132 | 33 KV Top clamps 75x75x6 mm Angle ( each weight 3.58 Kg) |
| 133 | 11 KV, 5KN PIN COMPOSITE POLYMER INSULATOR |
| 134 | 11 KV TOP CLAMPS 65X65X6MM ANGLE TYPE (each weight-3.0 Kg) |
| 135 | 33 KV Polymer composite 70 KN Disc Insulator |
| 136 | 33 KV COMPOSITE POLYMER STRAIN SET WITH HARD WARE SUITABLE FOR PANTHER CONDUCTOR (FOR 33KV SIDE) |
| 137 | 33 KV , 45 KN 16mm FRP with 25mm per KV Creepage DISC POLYMER LONG ROD TYPE T&C INSULATOR (FOR 11KV SIDE) |
| 138 | 33 KV COMPOSITE POLYMER STRAIN SET WITH HARD WARE SUITABLE FOR PANTHER CONDUCTOR (FOR 11KV SIDE) |
| 139 | Stone Block/Pre cast block for base pedding 450x450x75mm |
| 140 | CONCRETING (1:3:6) OF H-BEAM @ 0.70CMT.PER POLE INCLUDING muffing |
| 141 | Supply,Erection & Installation of DP STRUCTURE OUT GOING 11 KV FEEDERs |
| 142 | Erection of 11.0 mtr. long Steel Tubular Poles (Designation 410: SP-54) ( bottom portion hot dip galvanized ) conforming to ISS: 2713 (P-l & ll)-1980 with base plate direct in earth including excavation, refilling and ramming etc. as required (l/6th length of the pole to be embedded in earth) and grouting with CC of ratio 1:3:6 (1 cement : 3 river sand : 6 jhama brick aggregate of 20 mm. Nos.minal size) ilc supply of cement, sand and brick aggregate complete with excavation, refilling of earth, ramming alongwith centering and shuttering as required (@> 0.273 Cum per Steel Tubular Pole as per TSECL specification) etc. and applying paints with ready mixed primer (two or more coats) and alluminium paint of approved quality to give an even shade etc. as required including carrying of poles from TSECL storeyardf M M Division, Agartala) to work site by mechnical transport/manual/handcart i/c loading unloading stacking as reqd. and as per direction of Eng-ln-Charge. |
| 143 | H- BEAM 11 METER 152 X 152 MM 37.1 KG/METER = 408.1 kg |
| 144 | DC.CROSS ARMS 8` CENTRE TO CENTRE 100X50X6 MM CHANNEL (each weight-56.32 Kg) |
| 145 | 11 KV, 5KN PIN COMPOSITE POLYMER INSULATOR |
| 146 | 11 KV STRAIN HARDWARE (T&C TYPE) FITTINGS |
| 147 | HORIZONATAL & CROSS BRACING 8' CENTRE (wt of each X-BRACING-64.29 Kg |
| 148 | Back Clamp suitable for H-Beam (MS Flat 65x8 mm)- each weight 1.92 Kg |
| 149 | Stay set 20 mm. complete without Stay wire (Hot Dipped galvanized) |
| 150 | Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg) |
| 151 | Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set ) |
| 152 | Stone Block/Pre cast block for base pedding 450x450x75mm |
| 153 | CONCRETING (1:3:6) OF H-BEAM @ 0.70 CMT.PER POLE INCLUDING muffing |
| 154 | CONCRETING (1:3:6) OF STAY @ 0.3 CMT. PER STAY (16MM) |
| 155 | EARTHING COIL OF 115 TURNS OF 50 MM.DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE |
| 156 | XLPE LT 1 - CORE ALUMINIUM UNARMOURED 70 SQMM CABLE |
| 157 | XLPE LT 1 - CORE ALUMINIUM UNARMOURED 120 SQMM CABLE |
| 158 | Supply,Installation, Dismantling,Erection of 33 KV EQUIPMENTS |
| 159 | Supply & Installation of 33/11 KV Power transformer , OFTC Type , 7500 KVA (Loss 5.5+40 KW) |
| 160 | Dismantling of 5 MVA, 33 / 11 KV Power Transformer and S/s equipment at Rubber Park S/s |
| 161 | Supply Installation and Commissioning of Indoor 33 KV 1200Amp 5 Panel VCB Breaker Panel (Including Two Incomer & Three Outgoing) with inbuilt Line CT, PT, Power Pack and Transmission Line Protection Protection for I/C panel & 1 Nos. O/G panel and Transformer protection for 2 O/G panel etc all complete as per approved drawing |
| 162 | Supply,Installation & Erection of 33 KV CT OUTDOOR TYPE |
| 163 | 33 KV CTs. (outdoor oil filled type) 200-100/1-1 Amps Single Phase, 3 Core |
| 164 | 33 KV CTs.(out door oil filled type) 400-200/1-1-1 Amps Single Phase, 3 Core |
| 165 | 33 KV Control & Relay Panel for Transformer with IEC 61850 compliant differential relay, numerical type with static TVM |
| 166 | 33 KV Control & Relay Panel for Feeder with IEC 61850 compliant Differential relay, numerical type with static TVM (For Bus Coupler also) |
| 167 | 33 KV ISOLATOR 1250 A. (1 Set=3Nos.) |
| 168 | 33 KV LA POLYMER TYPE GAPLESS /METAL OXIDE SUBSTATION TYPE (1 Set=3 Nos.) |
| 169 | 33 KV / 0.11 kv SINGLE PHASE PTS OIL IMMERSED, outdoor with marshling box (1Set=3Nos.) |
| 170 | T'/ 'I' / other Clamp/power connector suitable for ACSR PANTHER Conductor and Al.tube as required. |
| 171 | 33 KV post insulator.(3 in 1 set) |
| 172 | Supply,Installation,Erection of 11 KV EQUIPMENTS |
| 173 | Design, Engineering, Supply of 11 KV, 1250Amps,25 KA for 3 sec. , 350 MVA rupturing capacity Indoor Vaccum Circuit Breakerf for outgoing feeder), complete with 1 set of CT of ratio 300/1-1, Control & Relay Pannel Simplex type with 110 Volt DC actuated electrical closing/tripping mechanism and internal wiring, 2-Over current & 1-earth fault combined Micom digital relay,1Nos.electromechanical AREVA Master Trip Relay, Differntial relays,auxiliary relays as required,1 Nos.L&T /SECURE make \\"Tri- Vector\\" Meter(SCADA compatible with communication facility), 3-Ammeter, 1 -Voltmeter, 1 -C.T operated static KW meter , with panel bus mounted C.T andintegral earthing facility including inernal arc tested panel Conforming to relevant with differentialISS/IEC as reqd. including standard indication facilities as per requirement detailed herein bid document. (1-Incoming & 3-Outgoing). |
| 174 | 2Core x 10 Sq.mm PVC Armoured Cable |
| 175 | 11 KV LA POLYMER TYPE GAPLESS /METAL OXIDE SUBSTATION TYPE |
| 176 | For substation metering- 3 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HT trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible ) modems, |
| 177 | SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB |
| 178 | 11 KV Under-Ground XLPE armoured Cable 3X120 Sq.mm. |
| 179 | Indoor heat shrinkable cable end jointing kit with lugs for 11 kV grade XLPE cable for 3 core 120 sq mm (Indoor 4Nos. + Outdoor 4Nos.) |
| 180 | COPPER CONTROL CABLE 12 CORE, 2.5 SQMM PVC UNARMOURED |
| 181 | COPPER CONTROL CABLE 8 CORE, 2.5 SQMM PVC UNARMORED |
| 182 | COPPER CONTROL CABLE 4 CORE, 2.5 SQMM PVC UNARMOURED |
| 183 | COPPER CONTROL CABLE 2 CORE, 2.5 SQMM PVC UNARMOURED |
| 184 | T CLAMP ALUMINUM FOR BUS BAR PANTHER RUN PANTHER TAP |
| 185 | BIMETALLIC CLAMPS FOR POWER TRANSFORMER 11KV SIDE |
| 186 | Supply of OTHER MISCELLANEOUS ITEMS |
| 187 | PVC CABLE 4 CORE ARMOURED 16 SQMM ALUMINIUM CONDUCTOR |
| 188 | M S BOLT WITH NUT 16X250 MM |
| 189 | M S BOLT WITH NUT 16X200 MM |
| 190 | M S BOLT WITH NUT 16X165 MM |
| 191 | M S BOLT WITH NUT 16X140 MM |
| 192 | M S BOLT WITH NUT 16X90 MM |
| 193 | M S BOLT WITH NUT 16X40 MM |
| 194 | RED-OXIDE PAINT |
| 195 | ALUMINUM PAINT |
| 196 | DANGER BOARD ENAMELED 33 KV AND 11 KV |
| 197 | Supply,Installation & Erection for Construction of new 33/11 KV S/s with 2x7.5MVA Power Transformer and 63 KVA Station Transformer (33/0.433KV)within IE area Bodhjungnagar IE at Zone 5 opposite of CRPF Camp. |
| 198 | MS MAIN AND WICKET GATE ON RCC COLUMN |
| 199 | YARD FENCING WITH CHAIN LINK MESH OVER RCC BEAM 2.4 mtr. Height |
| 200 | Boundary wall with RCC column and Brick work |
| 201 | MS SIGN BOARD, BAY INDICATION BOARD & RYB PHASE INDICATION BOARD |
| 202 | Yard Leveling by Kopra filling |
| 203 | Laying of Metal in yard by 100 mm thick metalling with 40 mm size B.T. Yard level to be increased by grouting Brick placed vertical 100 mm above of the ground and remaining part of the brick kept inside the ground |
| 204 | Procedure to avoid grass in sub-station yard- Black Cotton. By laying stone cursher dust. Base Rates combined for both the layers |
| 205 | RCC Cable Trench (Length suitable for substation area)Construction work of RCC utility duct i/c excavation, base slab, RCC wall, Top slab, RCC drain * drain cover, from works etc, including reinforcement HYSD bar etc., for laying 2 nos. 33KV, 2 no. 11kv, 2 no. LT underground cableItem Length Width Depthexcavation L 2.85 1.775PCC (M-15) L 1.85 0.075RCC Base Slab L 1.70 0.150(M-25)RCC wall 2xL 0.15 1.400(M-25)Top Slab (M-25) L 1.70 0.150 |
| 206 | 7.5 MVA Transformer Base (2 Tr.= 130 Cum.)Concrete :1:1.5:3 Ratio-5.634 cmt, concrete :1:5:8 Ratio-7.545 cmt., M.S. Flat/rod-324.87 kg and Base filling by Kopra in case of Black cotton soil 3.1*3.1*0.5m= 4.8 cmt]Base filling by Kopra -1.92 cmt., concreting, curing and back filling of pits. All complete works |
| 207 | Switch yard Equipment foundations including CT, PT, Isolator, LA etc |
| 208 | CONCRETING (1:3:6) OF VCB STRUCTURES 3.5 cmt per VCB |
| 209 | Full GI Tubular Pole 11 m Long with 1.5m Arm Bracket |
| 210 | LED Yard Lighting 80 Watt Flood Light |
| 211 | PROVIDING & FIXING PERFORATED CABLE TRAY 300 MM WIDE & 2 MM THICK FIXED ON 45X45X5 MM M.S. ANGLE STAND GROUTED IN C.C 1:24 |
| 212 | PROVIDING AND FIXING EARTH PIT OF BRICK MASSONERY 0.6 X 0.6 M INNER SIZE WITH FLAG STONE COVER FOR WATERING SYSTEM FOR 18 Nos. EARTH PITS |
| 213 | Costruction of retaining wall 1.5 M high as per site requirement |
| 214 | Excavation of earth pit, putting cast iron pipe with flange on one end (as per ISS 7181/86) of nominal dia 125 mm and 2.75 mtrs long inside the pit including supply and fixing RCC collars 0.75 mtr dia(OD) 50mm thick and 0.6 mtrs long inside the pit, back fill the pit in the 25 mm size granules of BH coke for full depth of the pit with alternate layers of BH coke and salt of 300 mm thick around the earth pipe of 150 mm on all the sides of the pipe including cost and conveyance of BH Coke,Salt,Clamps,CI pipes and RCC collars, labour charges for all operational and incidental items of work etc., complete and including cost of CI pipe. |
| 215 | Mesh earthing of Addl. PTR at 33/11KV Sub-station in Murrum soil with Galvanized mild steel flat (50x6 mm.) for forming mesh between different equipments. |
| 216 | Earthing of Station Transformer /40 mm Dia (For Murrum soil) (1 Set=4Nos.) |
| 217 | Supply & Installation for Internal electrification work for S/S control room :Wiring for light/fan/exhaustfan/callbell point with 1.5 sqmm |
| 218 | mm pvc insulated. Cu conductor cable in pvc casing capping etc. as reqd. |
| 219 | b)Medium Point |
| 220 | c)Long Point |
| 221 | Wiring for 3 pin 5/6 amps plug point with 1.5 sq mm pvc insu. allu. condo cable in pvc casing capping ilc providing & fixing 3 pin 5/6 amps socket outlet & 5/6 amps piaNos. type switch earthing the 3rd pin etc. as reqd |
| 222 | Wiring for 3 pin 15/16 amps plug point with 4 sq mm pvc insu. allu. condo cable in pve casing capping ilc providing & fixing 3 pin 5/6 amps socket outlet & 5/6 amps piaNos. type switch earthing the 3rd pin etc. as reqd |
| 223 | Supplying and fixing ofaccessories for PVC casing and capping in/c. necessary connection as required. Make: - Anchor / Precision / Cona (Nice) / SSK / J.J. Deluxe (Fancy), a) Ceiling rose. |
| 224 | b)Angle lamp holder. |
| 225 | c)5/6Amp. piaNos.witch. |
| 226 | Supplying and fixing ofaccessories for PVC casing and capping in/c. necessary connection as required, a) 102 mm X 102 mm, size wooden formica board with bakelite cover. |
| 227 | b)102 mm X 178 mm, size wooden formica board with bakelite cover. |
| 228 | c)152 mm X 203 mm, size wooden formica board with bakelite cover. |
| 229 | d)203 mm X 300 mm, size wooden formica board with bakelite cover. |
| 230 | e)254 mm X 300 mm, size wooden formica board with bakelite cover. |
| 231 | Wiring for circuital submainwiring with the following sizes pvc insulated ISI marked. Cu. cable in pvc casing capping etc. as reqd( FiNos.lex/Havells) a) 2 x 1.5 sq mm |
| 232 | b)2 x 4 sq mm |
| 233 | c)4 x 10 sq mm |
| 234 | d)2 x 6 . sq mm |
| 235 | Earthing with G.l. earth pipe 4.5 mtrs long & 40 mm dia with masonary enclosure on the top etc as reqd. |
| 236 | Extra for using salt & charcoal, coke for pipe earth electrode as reqd |
| 237 | Providing & fixing of 4.06mm (8SWG) dia G.l. wire in 19 mm dia polythene pipe in recess for loop earthing |
| 238 | Supplying & drawing 4 sq mm Allu.. condo cable for loop earthing along with other wires as reqd |
| 239 | Supply, Installation, testing &commissioning of ceiling fan (48 inch sweep) with all accessories i/c speed regulator, caNos.py, down rod of standard length) upto 30 cm )etc. as reqd and also required supplying, fixing and fabrication of extra down rod wherever necessary.(Usha / Khaitan/ Cromptom / Orient) |
| 240 | Supplying & fixing of busbarchamber with 4 strips busbar of length 300 mm made of allu. alloy or wrought alloy suitable for 100 amps capacity with all accessories i/c painting etc. as reqd (GECD make) |
| 241 | Supplying & fixing of 25mm x 25mm x 6mm size MS angle frame with 20 cm long 4 Nos. legs grouted on wall by 1 :2:4 cc work i/c providing & fixing 25 mm gamair wooden plank ile painting etc as reqd |
| 242 | Supplying & fixing of following TPN main switch (rew) 450 volts i/c drilling holes on board/M.S. Clamp connections etc. as reqd.(cat-B) (Havells/HPL) a)100 ampsTPN |
| 243 | b) 63ampsTPN |
| 244 | Supplying & fixing of following metal enclosure for 240/415 volts MCB single pole or Isolator complete with busbar, earthbar, neutral link, dinrail etc i/cconn. as reqd (cat-B)(Havells/HPL) a) 8 way |
| 245 | b)6 way DB |
| 246 | c)4 wayDB |
| 247 | Supplying & fixing of 5 to 32amps rating 240 volts 'G' series MCB of' single pole in the existing MCB DB complete with connection etc; as reqd. (Cat:-B) |
| 248 | Supplying & fixing of 230 mm sweep exhaust fan in existing hole i/c conn |
| 249 | Supplying & fixing of necessary shutter for 230 mm sweep exhaust fan in existing hole i/c necessary conn, as reqd |
| 250 | Supplying & fixing of Ding Dong callbell i/c necessary conn, etc as reqd. |
| 251 | Supplying & fixing of electronic musical call bell i/c necessary conn, etc as reqd |
| 252 | Supplying & fixing of 32 amps DP switch (kitkat) i/c necessary connections as reqd. |
| 253 | Supplying and fixing of single box type FTL fittings completewith 1 Nos. 40 / 36 watt copperballast, 40/36 watt flurosenttube, starter, holder, pfimproving capacitor etc. in/c. connection as required. (Make: - Phillips / Havells/ Crompton / Bajaj). |
| 254 | Supplying and fixing of doublebox type T 5 rated energy |
| 255 | Supplying & fixing of fancybracket light tittings complete with 1 Nos. 11 watt CFL light glass cover, holder etc i/c conn, as reqd:- (Crompton/Havells make) |
| 256 | Supply and Erection of Sign board with providing 1.6mm thickness MS Sheet (6X4) ft- (lengthX bradth) size of Iron sheet i/c painting of board by screen printing method,6ft height board from ground level,support L type angle(3\\" X3\\",6mm thickness),1.50 ft length of angle to be buried in the ground with 1ft hole pass inside with grouting etc as per approved drawing,design & technical specification and scope of work. |
| 257 | 1000 LITER P/F SINTEX OVERHEAD TANK & GI PIPE (WITH LENGTH OF 125 MTRS) FITTING FOR WATER SUPPLY INCLUDING WATER TAP(17 Nos.) NEAR TRANSFORMER NEUTRAL EARTHING |
| 258 | PROVIDING AND FIXING 5HP SUBMERSIBLE PUMP |
| 259 | Furniture for control room Table 600mmx 900mm- 1Nos., Chair- 3Nos., Computer table 1Nos. (Godrej or equivalent ) |
| 260 | VRLA Battery Set 110 Volt, 240 AH (1 Set=55 nos.) |
| 261 | Sub station Battery charger suitable for 240 AH, 110 Volt Battery Bank 2.2V,60 Nos,& 5Nos. Spares |
| 262 | 110 V DC Distribution Feeder |
| 263 | Supply, installation, testing & commissioning of wall mounted A.C. Sub distribution board (ACDB-2), comprising of 200 A MCCB I/C, PIL, 200/5A CT (3 Nos.) A+AS, V+VS, Outgoing- 32A TPN MCB 2 Nos., 63A TPN MCB 2 Nos., 16A SPN MCB 9 Nos. |
| 264 | Fire extinguisher ABC Type 6 Kg |
| 265 | Sand buckets 5 Nos. on each earth stand with caNos.py |
| 266 | First Aid Boxes |
| 267 | 33 KV Hand Gloves |
| 268 | 11 KV Hand Gloves |
| 269 | Safety Helmet |
| 270 | Safety Shoes |
| 271 | Half Safety Belt |
| 272 | Portable Fire Extinguisher DCP-ABC Powder Type composite body (MFCF-Maintenance Free corrossion free,Powder-2Kg) |
| 273 | Earth Discharge Rod -33 KV |
| 274 | Rubber Mat for 33 kV 6 x 4 feet (Thickness as per IS 15652) |
| 275 | Insulation Tester (Megger Make) 5000 V |
| 276 | Earth Tester |
| 277 | Mili Amp AC Clamp Meter (make Motwani) |
| 278 | Digital Multimeter |
| 279 | DP Structure for 33 KV Incoming and Outgoing |
| 280 | Design, Engineering, manufacturing, Supply of SteelTubular Pole, ll.Omtr. Long (Designation 410: SP-54) (bottom portion hot dip galvanized ) conforming to ISS: 2713(P-I & ll)/1980 as amended up-to-date and other relevant IS with up-to-date amendments with base plate and as per technical specification of bid document. |
| 281 | Erection of 11.0 mtr. long Steel Tubular Poles (Designation 410: SP-54) ( bottom portion hot dip galvanized ) conforming to ISS: 2713 (P-l & ll)-1980 with base plate direct in earth including excavation, refilling and ramming etc. as required (l/6th length of the pole to be embedded in earth) and grouting with CC of ratio 1:3:6 (1 cement : 3 river sand : 6 jhama brick aggregate of 20 mm. Nos.minal size) ilc supply of cement, sand and brick aggregate complete with excavation, refilling of earth, ramming alongwith centering and shuttering as required (@> 0.273 Cum per Steel Tubular Pole as per TSECL specification) etc. and applying paints with ready mixed primer (two or more coats) and alluminium paint of approved quality to give an even shade etc. as required including carrying of poles from TSECL storeyardf M M Division, Agartala) to work site by mechnical transport/manual/handcart i/c loading unloading stacking as reqd. and as per direction of Eng-ln-Charge. |
| 282 | H- BEAM 11 METER 152 X 152 MM 37.1 KG/METER = 408.1 kg |
| 283 | DC.CROSS ARMS 8` CENTRE TO CENTRE 100X50X6 MM CHANNEL (each weight-26.32 Kg) (ONE SET FOR FEEDER AND ONE SET FOR ISOLATOR/ME) (1 Set=2Nos.) |
| 284 | Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg)(1 Set=2Nos.) |
| 285 | HORIZONATAL & CROSS BRACING 8' CENTRE (wt of each X-BRACING-64.29 Kg (1 Set=2Nos.) |
| 286 | Back Clamp suitable for H-Beam (MS Flat 65x8 mm)- each weight 1.92 Kg |
| 287 | 33 KV Polymer composite 70 KN Disc Insulator |
| 288 | 33 KV Strain hardware (T&C type) fittings |
| 289 | 33 KV 900 mm CD Polymer Composite pin insulator |
| 290 | Stay set 20 mm. complete without Stay wire (Hot Dipped galvanized) |
| 291 | Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg)(1Set=2Nos.) |
| 292 | STAY WIRE 7/4.00 MM.(7/8 SWG)(8.5 kg./stay) |
| 293 | Stone Block/Pre cast block for base pedding 450x450x75mm |
| 294 | CONCRETING (1:3:6) OF H-BEAM @ 0.7 CMT.PER POLE INCLUDING muffing |
| 295 | CONCRETING (1:3:6) OF STAY @ 0.3 CMT. PER STAY (20MM) |
| 296 | EARTHING COIL OF 115 TURNS OF 50 MM.DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE |
| 297 | Supply,installation & Erection for structures and bus-bar arrangements |
| 298 | H- BEAM 9 METER 152 X 152 MM 37.1 KG/METER = 333.9 kg. FOR 33KV GANTRY STRUCTURE |
| 299 | H- BEAM 9 METER 152 X 152 MM 37.1 KG/METER = 333.9 kg. FOR 11KV GANTRY STRUCTURE |
| 300 | H- BEAM 7 METER 152 X 152 MM 37.1 KG/METER = 259.7 kg. FOR 5' CENTER JUMPER SUPPORT FOR 33 & 11KV SIDE |
| 301 | D.C. CHANNEL 4.8 MTR CENTRE 100X50X6MM FOR 33KV BUS BAR (each weight-99.90 Kg)(1Set=2Nos.) |
| 302 | D.C. CHANNEL 4.8 MTR CENTRE 100X50X6MM FOR 11KV BUS BAR (each weight-99.90 Kg)(1Set=2Nos.) |
| 303 | D.C.cross- arm of 100 X 50 X 6 mm. ISMC channel suitable for 5' centre (65.09 kg each)(1Set=2Nos.) |
| 304 | Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg)(1Set=2Nos.) |
| 305 | STRAIN PLATE (IS MS FLAT 65X8X250MM) 0.65 Kg each |
| 306 | ACSR PANTHER CONDUCTOR 0.20 SQ. INCH (200 SQ.MM AL.EQ.) |
| 307 | 33 KV 900 mm CD Polymer Composite pin insulator |
| 308 | 33 KV Top clamps 75x75x6 mm Angle ( each weight 3.58 Kg) |
| 309 | 11 KV, 5KN PIN COMPOSITE POLYMER INSULATOR |
| 310 | 11 KV TOP CLAMPS 65X65X6MM ANGLE TYPE (each weight-3.0 Kg) |
| 311 | 33 KV Polymer composite 70 KN Disc Insulator |
| 312 | 33 KV COMPOSITE POLYMER STRAIN SET WITH HARD WARE SUITABLE FOR PANTHER CONDUCTOR (FOR 33KV SIDE) |
| 313 | 33 KV , 45 KN 16mm FRP with 25mm per KV Creepage DISC POLYMER LONG ROD TYPE T&C INSULATOR (FOR 11KV SIDE) |
| 314 | 33 KV COMPOSITE POLYMER STRAIN SET WITH HARD WARE SUITABLE FOR PANTHER CONDUCTOR (FOR 11KV SIDE) |
| 315 | Stone Block/Pre cast block for base pedding 450x450x75mm |
| 316 | 33 KV 90+B311+B321+B311+B321 |
| 317 | Supply,Installation & Erection of DP STRUCTURE for OUT GOING 11 KV FEEDERs |
| 318 | Design, Engineering, manufacturing, Supply of SteelTubular Pole, ll.Omtr. Long (Designation 410: SP-54) (bottom portion hot dip galvanized ) conforming to ISS: 2713(P-I & ll)/1980 as amended up-to-date and other relevant IS with up-to-date amendments with base plate and as per technical specification of bid document. |
| 319 | Erection of 11.0 mtr. long Steel Tubular Poles (Designation 410: SP-54) ( bottom portion hot dip galvanized ) conforming to ISS: 2713 (P-l & ll)-1980 with base plate direct in earth including excavation, refilling and ramming etc. as required (l/6th length of the pole to be embedded in earth) and grouting with CC of ratio 1:3:6 (1 cement : 3 river sand : 6 jhama brick aggregate of 20 mm. Nos.minal size) ilc supply of cement, sand and brick aggregate complete with excavation, refilling of earth, ramming alongwith centering and shuttering as required (@> 0.273 Cum per Steel Tubular Pole as per TSECL specification) etc. and applying paints with ready mixed primer (two or more coats) and alluminium paint of approved quality to give an even shade etc. as required including carrying of poles from TSECL storeyardf M M Division, Agartala) to work site by mechnical transport/manual/handcart i/c loading unloading stacking as reqd. and as per direction of Eng-ln-Charge. |
| 320 | H- BEAM 11 METER 152 X 152 MM 37.1 KG/METER = 408.1 kg |
| 321 | DC.CROSS ARMS 8` CENTRE TO CENTRE 100X50X6 MM CHANNEL (each weight-56.32 Kg)(1Set=2Nos.) |
| 322 | 11 KV, 5KN PIN COMPOSITE POLYMER INSULATOR |
| 323 | 11 KV STRAIN HARDWARE (T&C TYPE) FITTINGS |
| 324 | HORIZONATAL & CROSS BRACING 8' CENTRE (wt of each X-BRACING-64.29 Kg (1Set=2Nos.) |
| 325 | Back Clamp suitable for H-Beam (MS Flat 65x8 mm)- each weight 1.92 Kg(1Set=2Nos.) |
| 326 | Stay set 20 mm. complete without Stay wire (Hot Dipped galvanized) |
| 327 | Clamp suitable for 152 X 152 mm., 37.1 Kg./mtr H-Beam ( each weight 3.2 kg)(1Set=2Nos.) |
| 328 | Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set ) |
| 329 | Stone Block/Pre cast block for base pedding 450x450x75mm |
| 330 | CONCRETING (1:3:6) OF H-BEAM @ 0.70 CMT.PER POLE INCLUDING muffing |
| 331 | CONCRETING (1:3:6) OF STAY @ 0.3 CMT. PER STAY (16MM) |
| 332 | EARTHING COIL OF 115 TURNS OF 50 MM.DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE |
| 333 | DP STRUCTURE FOR 11/.04 KV 63 KVA STATION TRANSFORMER (1 Nos.) |
| 334 | Design, Engineering, manufacturing, Supply of SteelTubular Pole, ll.Omtr. Long (Designation 410: SP-54) (bottom portion hot dip galvanized ) conforming to ISS: 2713(P-I & ll)/1980 as amended up-to-date and other relevant IS with up-to-date amendments with base plate and as per technical specification of bid document. |
| 335 | Erection of 11.0 mtr. long Steel Tubular Poles (Designation 410: SP-54) ( bottom portion hot dip galvanized ) conforming to ISS: 2713 (P-l & ll)-1980 with base plate direct in earth including excavation, refilling and ramming etc. as required (l/6th length of the pole to be embedded in earth) and grouting with CC of ratio 1:3:6 (1 cement : 3 river sand : 6 jhama brick aggregate of 20 mm. Nos.minal size) ilc supply of cement, sand and brick aggregate complete with excavation, refilling of earth, ramming alongwith centering and shuttering as required (@> 0.273 Cum per Steel Tubular Pole as per TSECL specification) etc. and applying paints with ready mixed primer (two or more coats) and alluminium paint of approved quality to give an even shade etc. as required including carrying of poles from TSECL storeyardf M M Division, Agartala) to work site by mechnical transport/manual/handcart i/c loading unloading stacking as reqd. and as per direction of Eng-ln-Charge. |
| 336 | BIS certified Energy Efficiency Level-III (Old)/Level-II (New) 33/0.433KV, 63 KVA Distribution Transformer (As per IS 1180 latest amendment) |
| 337 | DC.CROSS ARMS 8` CENTRE TO CENTRE 100X50X6 MM CHANNEL (each weight-26.32 Kg)+C348:C355(1Set=2Nos.) |
| 338 | Clamp A type 65x8mm of MS Flat for R.S. Joist(175x85mm) |
| 339 | 11 KV, 45 KN DISC T&C COMPOSITE POLYMER LONG ROD INSULATOR |
| 340 | 11 KV STRAIN HARDWARE (T&C TYPE) FITTINGS |
| 341 | 9 KV Gapless type LA ( 5KA) Polymer for DTR |
| 342 | D.O.MOUNTING CHANNEL 75X40X6MM (each wt 19.37 Kg) |
| 343 | 11 KV Drop out Fuse (Porcelin) |
| 344 | TRANSFORMER MOUNTING CHANNEL 100X50X6MM (each wt 52.63 Kg)(1Set=2Nos.) |
| 345 | TRANSFORMER CLAMPING SET 50X50 X6 MM ANGLE 460MM LONG (each wt 52.63 Kg)(1Set=2Nos.) |
| 346 | ACSR Rabitt 50 sqmm |
| 347 | DANGER BOARD ENAMELED 11 KV |
| 348 | L.T.DISTRIBUTION BOX FOR 63 KVA TRANSFORMER (200 A. ISOLATOR & 6 SP MCCB OF 90 A.) made of SMC |
| 349 | XLPE LT 1 - CORE ALUMINIUM UNARMOURED 70 SQMM CABLE |
| 350 | CONCRETING (1:3:6) OF H-BEAM @ 0.6 CMT.PER POLE INCLUDING BASE PEDDING |
| 351 | 33 KV EQUIPMENTS |
| 352 | Supply & Installation of 33/11 KV Power transformer , OFTC Type , 7500 KVA (Loss 5.5+40 KW) |
| 353 | Design, Engineering, manufacturing, supply of 33 KV,1250A, 750 MVA rupturing capacity, outdoor Vacuum Circuit Breaker complete with motor operated spring closing (Local / Remote) arrangement with all accessories including lattice support structure,foundation bolts,G.l. nuts & bolts,washers etc. as required and as per relevant ISS complete operative on 110V DC. |
| 354 | Laptop for reading in Control & Protection Panel roomHP/DELL 12Generation Intel @ Core i5-1235U Window 11 Home single language intel@ Iris Xe Graphics RAM:-16GB,8GBx2,DDR4,2666MT/s,HARD Disk :-512GB,M.2,PCIe,NVMe.SSD.Display size:- 39.6 C.m.Full HD (1920 x 1080),Weight :1.65 Kg |
| 355 | HP/CaNos.n LaserJet Pro MFP M126a PrinterHP 1008a MoNos.chrome Laser Printer Single Function with USB connectivity |
| 356 | DELL/HP All-in-One PC 12th Gen Intel Core i5-1235U 24-inch(60.5 cm) FHD Anti Glare Desktop (8GB RAM/512GB/Windows 11/Wireless Keyboard and Mouse Combo/MSO/IR Privacy Camera/Jet Black) 24-cb1907 |
| 357 | Compact Design Line Interactive UPS with Load Capacity of 360Watts / 600VA. Output Frequency (sync to mains) : 47 - 63 Hz Sync to mainsThree Battery Backed up and Surge Protected 6A, 2/3 Pin Output Indian Power SocketAutomatic Voltage Regulator (AVR) with Wide Input Voltage Range 145-290V, Transfer Time - 10 ms typical : 12 ms maximum1x7.2Ah Battery provides 20 - 75 min. Back-Up time *as per the loadGenerator Compatible; Compatible with low power loads e.g. Wi-Fi router, DSL modemCold start capability allows the load to power on just on battery; Stays quiet during a changeover from mains to generator |
| 358 | 33 KV CT OUTDOOR TYPE |
| 359 | 33 KV CTs.(out door oil filled type) 200-100/1-1-1 Amps Single Phase, 3 Core |
| 360 | 33 KV CTs.(out door oil filled type) 300-150/1-1-1 Amps Single Phase, 3 Core |
| 361 | 33 KV Control & Relay Panel for Transformer with IEC 61850 compliant differential relay, numerical type with static TVM |
| 362 | 33 KV ISOLATOR 630 A. |
| 363 | Erection, testing & commissioning of 33 KV, 1250A, 750 MVA rupturing capacity, outdoor Vacuum Circuit Breaker complete with motor operated spring closing (Local / Remote) arrangement with all accessories including lattice support structure,foundation bolts,G.l. nuts & bolts,washers etc. as required and as per relevant ISS complete operative on 110V DC. |
| 364 | 33 KV LA POLYMER TYPE GAPLESS /METAL OXIDE SUBSTATION TYPE(1 set=3Nos.) |
| 365 | 33 KV / 0.11 kv SINGLE PHASE PTS OIL IMMERSED, outdoor with marshling box |
| 366 | 11 KV EQUIPMENTS |
| 367 | 11 KV 1250 Amp, 25kA Indoor VCB Panel (Incomer) Complete with CT PT, Relays etc. all accessories |
| 368 | Erection, testing & commissioning of 11 KV, 1250Amps, 25 KA for 3 seconds, 350 MVA rupturing capacity Indoor Vaccum Circuit Breaker, complete with Control & Relay Pannel Simplex type with 3Phase pannel topmounted PT of ratio: 11000 /110Volt,110 Volt DC actuated electrical closing mechanism and internal wiring, Numerical as well as electromechanical protection by 2-Over current & 1-earth fault combined ( Micom or other reputed make) digital & electromechanical relays forintegrated protection,! Nos.electromechanical AREVAMaster Trip Relay, auxiliary relays as required,! Nos.L&T / SECURE make \\"Tri- Vector\\" Meter(SCADA compatible) 3- Ammeter, 1 -Voltmeter, 1 -C.T operated static KW meter, with panel bus mounted C.T andintegral earthing facility including inernal arc testedpanel conforming to relevant ISS/IEC as reqd.includingstandard indication facilities as per requirement detailed in bid document.CTR 400-200/1-1-0.577A |
| 369 | Incoming pannel with (CTR:600-400/1-1-0.577A) |
| 370 | For substation metering- 3 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HT trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible ) modems, |
| 371 | 11 KV LA POLYMER TYPE GAPLESS /METAL OXIDE SUBSTATION TYPE(1 set=3Nos.) |
| 372 | SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB |
| 373 | 11 KV 1500 KVAR AUTO SWITCH CAPACITOR BANK INCLUDING ASSOCIATED EQUIPMENTS SUCH AS 11 KV VACUUM CIRCUIT BREAKER, CONTROL PANEL, 11 KV OUTDOOR CURRENT TRANSFORMER WITH ADEQUATE METERING & PROTECTION CLASS OF SERVICE, BUS & EQUIPMENT ISOLATORS WITH EARTH SWITCH, MATCHING RVT, SUITABLE GAPLESS LIGHTENING ARRESTORS, NECESSARY CABLES FOR SUCCESSFUL COMMISSIONING COMPLETE |
| 374 | 11 KV Under-Ground XLPE armoured Cable 3X240 Sq.mm. |
| 375 | Indoor heat shrinkable cable end jointing kit with lugs for 11 kV grade XLPE cable for 3 core 240 sq mm (Indoor + Outdoor)(1 Set=3Nos.) |
| 376 | COPPER CONTROL CABLE 12 CORE, 2.5 SQMM PVC UNARMOURED |
| 377 | COPPER CONTROL CABLE 8 CORE, 2.5 SQMM PVC UNARMORED |
| 378 | COPPER CONTROL CABLE 4 CORE, 2.5 SQMM PVC UNARMOURED |
| 379 | COPPER CONTROL CABLE 2 CORE, 2.5 SQMM PVC UNARMOURED |
| 380 | T CLAMP ALUMINUM FOR BUS BAR PANTHER RUN PANTHER TAP |
| 381 | BIMETALLIC CLAMPS FOR POWER TRANSFORMER 11KV SIDE |
| 382 | OTHER MISCELLANEOUS ITEMS |
| 383 | PVC CABLE 2 CORE ARMOURED 2.5 SQMM ALUMINIUM CONDUCTOR |
| 384 | PVC CABLE 4 CORE ARMOURED 16 SQMM ALUMINIUM CONDUCTOR |
| 385 | M S BOLT WITH NUT 16X250 MM |
| 386 | M S BOLT WITH NUT 16X200 MM |
| 387 | M S BOLT WITH NUT 16X165 MM |
| 388 | M S BOLT WITH NUT 16X140 MM |
| 389 | M S BOLT WITH NUT 16X90 MM |
| 390 | M S BOLT WITH NUT 16X40 MM |
| 391 | RED-OXIDE PAINT |
| 392 | ALUMINUM PAINT |
| 393 | DANGER BOARD ENAMELED 33 KV AND 11 KV |
| 394 | Supply and Laying of UG 11 KV XLPE 240 sqmm Cable for new 11 KV Feeders inside Bodhjungnagar IE up to 4KM |
| 395 | Supply of 3 phase 3 core 11 kv xlpe 240 sqmm al power cable |
| 396 | Laying of 3 phase 3 core 11 kv xlpe 240 sqmm al power cable in trench 350 mm x 1200 mm, sand cushioning 250x350 sqmm, brick protection 120 sqmm |
| 397 | Excavation of cable entry pit through hdpe pipe pe80 pn 6, 400 mm od |
| 398 | Supply and erection of p80. Pn6, 400 mm od hdpe pipe |
| 399 | Coiling of excess 240 sqmm cable in pit size 2250 x 2250 sqmm minimimum by brick laying and 300 mm fine sand / Duct |
| 400 | Outdoor cable termination with heat shrinkable jointing kit 240 sqmm (1 Set=3Nos.) |
| 401 | Route marker complete with danger sign |
| 402 | 11 kv danger plate |
| 403 | Ms nuts & bolts assorted size |
| 404 | Bi metallic lugs 240 sqmm |
| 405 | Ht kiosks complete |
| 406 | 8 swg gi wire |
| 407 | Route survey of existing line and proposed network |
| 408 | 11 kv 3 way rmu SBB (12 KV Motorised Ring Main Unit self power type with CPT or by other means,Solod or SF6 Insulation Outdoor enclosure,with all accessories.) |
| 409 | Supply and Laying of UG 11 KV XLPE 180 sqmm Cable for replacement of OH Network inside Bodhjung Nagar IE up to 10KM & Dismantling of 11KV OH Network within IE up to 15KM. |
| 410 | Dismantling of 11KV OH Network within IE |
| 411 | Dismantling of 10 mtrs,11mtrs & 12mtrs length of steel Tubular Pole at any kind of soil,including excavation of earth,refilling the pit with soil upto the ground level,ramming and making complete in all respect. |
| 412 | Dismantling of stay set from the earth complete with 19mmx1800mm long stay rod,anchor plate of size 300x300x8mm,thimble,turn buckle,7/3.15mm dia G.I. Standard stay wire and stain insulator etc. and making complete in all respet |
| 413 | Dismantling of 11KV pin insulator along with pin |
| 414 | Dismantling of Disc insulator set for 11KV line along with necessary fittings |
| 415 | Dismantling of 7KM(Single Conductor) ACSR 6/1/4.10 mm dia RACOON including coiling etc. Complete as required |
| 416 | Dismantling of V Cross-Arm 65x65x6mm MS Angle/75x40x40x6mm MS Channel |
| 417 | Dismantling of Barbed wire (Anti climbing device) per pole |
| 418 | Dismantling of 5KM (Single Conductor),10/8 SWG GI wire including coiling etc.Complete as required. |
| 419 | Supply & Laying of UG Cable up to 10KM |
| 420 | Supply of 3 phase 3 core 11 kv xlpe 180 sqmm al power cable |
| 421 | Laying of 3 phase 3 core 11 kv xlpe 180 sqmm al power cable in trench 350 mm x 1200 mm, sand cushioning 250x350 sqmm, brick protection 120 sqmm |
| 422 | Excavation of cable entry pit through hdpe pipe pe80 pn 6, 400mm od |
| 423 | Supply and erection of p80. Pn6, 400 mm od hdpe pipe |
| 424 | Coiling of excess 240 sqmm cable in pit size 2250 x 2250 sqmm minimimum by brick laying and 300 mm fine sand / Duct |
| 425 | Outdoor cable termination with heat shrinkable jointing kit 240 sqmm (1 Set=3Nos.) |
| 426 | Route marker complete with danger sign |
| 427 | 11 kv danger plate |
| 428 | Ms nuts & bolts assorted size |
| 429 | Ht kiosks complete |
| 430 | 8 swg gi wire |
| 431 | Route survey of existing line and proposed network |
| 432 | Supply and Laying of UG 11 KV XLPE 185 sqmm Cable for new 11 KV Feeders inside Bodhjung Nagar IE up to 2KM |
| 433 | Supply of 3 phase 3 core 11 kv xlpe 185 sqmm al power cable |
| 434 | Laying of 3 phase 3 core 11 kv xlpe 185 sqmm al power cable in trench 350 mm x 1200 mm, sand cushioning 250x350 sqmm, brick protection 120 sqmm |
| 435 | Excavation of cable entry pit through hdpe pipe pe80 pn 6, 400 mm od |
| 436 | Gi / hdpe pipe for raiser up to 400 sqmm |
| 437 | Coiling of excess 185 sqmm cable in pit size 2250 x 2250 sqmm minimimum by brick laying and 300 mm fine sand / Duct |
| 438 | Outdoor cable termination with heat shrinkable jointing kit 185 sqmm (1 Set=3Nos.) |
| 439 | Route marker complete with danger sign |
| 440 | 11 kv danger plate |
| 441 | Ms nuts & bolts assorted size |
| 442 | Bi metallic lugs 185 sqmm |
| 443 | Ht kiosks complete |
| 444 | 8 swg gi wire |
| 445 | Route survey of existing line and proposed network |
| 446 | 11 kv 3 way rmu SBB (12 KV Motorised Ring Main Unit self power type with CPT or by other means,Solod or SF6 Insulation Outdoor enclosure,with all accessories.) |
| 447 | Supply and Laying of UG 11 KV XLPE 185 sqmm Cable for replacement of 11 KV Feeders inside Bodhjung Nagar IE up to 6KM with Dismantling of 11KV OH line Network for HT Consumer( Brikolite, RFL and Pran) up to 7KM. |
| 448 | Dismantling of 11KV OH line Network up to 7KM |
| 449 | Dismantling of 10 mtrs,11mtrs & 12mtrs length of steel Tubular Pole at any kind of soil,including excavation of earth,refilling the pit with soil upto the ground level,ramming and making complete in all respect. |
| 450 | Dismantling of stay set from the earth complete with 19mmx1800mm long stay rod,anchor plate of size 300x300x8mm,thimble,turn buckle,7/3.15mm dia G.I. Standard stay wire and stain insulator etc. and making complete in all respet |
| 451 | Dismantling of 11KV pin insulator along with pin |
| 452 | Dismantling of Disc insulator set for 11KV line along with necessary fittings |
| 453 | Dismantling of 7KM(Single Conductor) ACSR 6/1/4.10 mm dia RACOON including coiling etc. Complete as required |
| 454 | Dismantling of V Cross-Arm 65x65x6mm MS Angle/75x40x40x6mm MS Channel |
| 455 | Dismantling of Barbed wire (Anti climbing device) per pole |
| 456 | Dismantling of 5KM (Single Conductor),10/8 SWG GI wire including coiling etc.Complete as required. |
| 457 | Supply & Laying of 11KV XLPE UG Cable |
| 458 | Supply of 3 phase 3 core 11 kv xlpe 185 sqmm al power cable |
| 459 | Laying of 3 phase 3 core 11 kv xlpe 185 sqmm al power cable in trench 350 mm x 1200 mm, sand cushioning 250x350 sqmm, brick protection 120 sqmm |
| 460 | Excavation of cable entry pit through hdpe pipe pe80 pn 6, 160 mm od |
| 461 | Supply and erection of p80. Pn6, 160 mm od hdpe pipe |
| 462 | Coiling of excess 185 sqmm cable in pit size 2250 x 2250 sqmm minimimum by brick laying and 300 mm fine sand / Duct |
| 463 | Outdoor cable termination with heat shrinkable jointing kit 185 sqmm (1 Set=3Nos.) |
| 464 | Route marker complete with danger sign |
| 465 | 11 kv danger plate |
| 466 | Ms nuts & bolts assorted size |
| 467 | Bi metallic lugs 185 sqmm |
| 468 | Ht kiosks complete |
| 469 | 8 swg gi wire |
| 470 | Route survey of existing line and proposed network |
| 471 | 11 kv 3 way rmu SBB (12 KV Motorised Ring Main Unit self power type with CPT or by other means,Solod or SF6 Insulation Outdoor enclosure,with all accessories.) |
| 472 | Supply and Laying of UG 11 KV XLPE 120 sqmm Cable for HT Consumers inside Bodhjung Nagar IE up to 7KM |
| 473 | Supply of 3 phase 3 core 11 kv xlpe 120 sqmm al power cable |
| 474 | Laying of 3 phase 3 core 11 kv xlpe 120 sqmm al power cable in trench 350 mm x 1200 mm, sand cushioning 250x350 sqmm, brick protection 120 sqmm |
| 475 | Excavation of cable entry pit through hdpe pipe pe80 pn 6, 160 mm od |
| 476 | Supply and erection of p80. Pn6, 160 mm od hdpe pipe |
| 477 | Coiling of excess 185 sqmm cable in pit size 2250 x 2250 sqmm minimimum by brick laying and 300 mm fine sand / Duct |
| 478 | Outdoor cable termination with heat shrinkable jointing kit 120 sqmm (1 Set=3Nos.) |
| 479 | Route marker complete with danger sign |
| 480 | 11 kv danger plate |
| 481 | Ms nuts & bolts assorted size |
| 482 | Bi metallic lugs 120 sqmm |
| 483 | 8 swg gi wire |
| 484 | Route survey of existing line and proposed network |
| 485 | Supply and Installation of 500 KVA, 11/0.4 KV DTR |
| 486 | BIS certified Energy Efficiency Level-III (Old)/Level-II (New) Convential 11/0.433KV, 500 KVA Distribution Transformer |
| 487 | Full GI Tubular Pole 11 m Long |
| 488 | D.c.cross-arm of 100 x50x 6 mm. 8' centre (1Set=2Nos.) |
| 489 | 11 kv (45kn) 16mm frp with 25mm per kv creepage disc insulator polymer |
| 490 | 11kv strain hardware fitting |
| 491 | 11 kv d.o. fuse & lightening arrestor mounting channel (75x 40 x 6 mm.) |
| 492 | 500KVA,11/0.4KV DTR Base (R.C.C.) |
| 493 | 11 kv d.o. fuse unit (Porcelin) |
| 494 | 9 kv gapless type LA ( 5ka) polymer for dtr |
| 495 | Transformer mounting dc cross-arm 100 x 50 x6 mm. Channel(1Set=2Nos.) |
| 496 | Transformer belting with 50 x 50 x 6 mm.angle with two cross fixing channels(1Set=2Nos.) |
| 497 | Clamp for size- ,wt-3.2 kg using 65x8 ms flat(1Set=2Nos.) |
| 498 | Stay set 20 mm. painted complete with turn buckles |
| 499 | Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set ) |
| 500 | Concreting of pole/ h-beam @ 0.70 cmt. Per pole with muffing (1:3:6) |
| 501 | Concreting of stay @ 0.2 cmt. Per stay (1:3:6) |
| 502 | Acsr conductor rabbit for jumper |
| 503 | Danger boards enamalled type 11kv |
| 504 | Ht bi-metallic clamp for dtr |
| 505 | Lt bi-metallic clamp for dtr 12 mm |
| 506 | Anti climbing devices (barbed wire 2.24 mm dia (14 swg) (3.5 kg. Wire per pole) |
| 507 | Red oxide paint |
| 508 | Aluminium paint |
| 509 | M.s.nuts and bolts |
| 510 | Distribution box mounting channel (75x40x6 mm.) |
| 511 | L.t. distribution box suitable for 500 kva transformer (without tpn switches) with mccb on incoming and pf units on outgoing side made of smc |
| 512 | LT 300 sq.mm.,3.5 core xlpe armoured aluminium conductor cable |
| 513 | LT Al Lugs 300 sqmm |
| 514 | 11 kv a.b. switch |
| 515 | DTR S/s fencing of 6' height with chain link fencing on MS Angle (50x50x6mm) support 7 Nos. 7' height with Double Gate |
| 516 | Earthing with G.l. earth pipe 4.5 mtrs long & 40 mm dia with masonary enclosure on the top etc as reqd. for Earthing of dtr |
| 517 | Supply and Installation of 315 KVA, 11/0.4 KV DTR |
| 518 | BIS certified Energy Efficiency Level-III (Old)/Level-II (New) Convential 11/0.433KV, 315 KVA Distribution Transformer |
| 519 | Full GI Tubular Pole 11 m Long |
| 520 | D.c.cross-arm of 100 x50x 6 mm. 8' centre |
| 521 | 11 kv (45kn) 16mm frp with 25mm per kv creepage disc insulator polymer |
| 522 | 11kv strain hard ware fitting |
| 523 | 11 kv d.o. fuse & lightening arrestor mounting channel (75x 40 x 6 mm.) |
| 524 | Back clamp for h-beam size-480 mm ,wt-1.92 kg using 65x8 ms flat |
| 525 | 11 kv d.o. fuse unit |
| 526 | 9 kv gapless type LA ( 5ka) polymer for dtr |
| 527 | 315KVA Transformer Base (R.C.C.) as per TSECL approved drawings |
| 528 | Clamp for h-beam size- ,wt-3.2 kg using 65x8 ms flat (1Set=2Nos.) |
| 529 | Stay set 20 mm. painted complete with turn buckles |
| 530 | Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set ) |
| 531 | Stone block/pre cast block for base pedding 450x450x75mm |
| 532 | Concreting of h-beam @ 0.70 cmt. Per pole with muffing (1:3:6) |
| 533 | Concreting of stay @ 0.2 cmt. Per stay (1:3:6) |
| 534 | Acsr conductor rabbit for jumper |
| 535 | Danger boards enamalled type 11kv |
| 536 | Ht bi-metallic clamp for dtr |
| 537 | Lt bi-metallic clamp for dtr 12 mm |
| 538 | Anti climbing devices (barbed wire 2.24 mm dia (14 swg) (3.5 kg. Wire per pole) |
| 539 | Red oxide paint |
| 540 | Aluminium paint |
| 541 | M.s.nuts and bolts |
| 542 | Distribution box mounting channel (75x40x6 mm.) |
| 543 | L.t. distribution box suitable for 315 kva transformer (without tpn switches) with mccb on incoming and pf units on outgoing side made of smc |
| 544 | LT 300 sq.mm.,3.5 core xlpe armoured aluminium conductor cable |
| 545 | LT Al Lugs 300 sqmm |
| 546 | 11 kv a.b. switch |
| 547 | DTR S/s fencing of 6' height with chain link fencing on MS Angle (50x50x6mm) support 7 Nos. 7' height with Double Gate |
| 548 | Earthing with G.l. earth pipe 4.5 mtrs long & 40 mm dia with masonary enclosure on the top etc as reqd. for Earthing of dtr |
| 549 | Supply and Installation of 63 KVA, 11/0.4 KV DTR for Street Light up to 2KM |
| 550 | Bis certified energy efficient, 11/0.433kV, 63 kVA distribution transformer (As per IS 1180 latest amendment) |
| 551 | Full GI Tubular Pole 11 m Long |
| 552 | D.c.cross-arm of 100 x50x 6 mm. 8' centre |
| 553 | 11 kv (45kn) 16mm frp with 25mm per kv creepage disc insulator polymer |
| 554 | 11kv strain hard ware fitting |
| 555 | 11 kv d.o. fuse & lightening arrestor mounting channel (75x 40 x 6 mm.) |
| 556 | Back clamp for h-beam size-480 mm ,wt-1.92 kg using 65x8 ms flat |
| 557 | 11 kv d.o. fuse unit |
| 558 | 9 kv gapless type ( 5ka) polymer for dtr |
| 559 | Transformer mounting dc cross-arm 100 x 50 x6 mm. Channel |
| 560 | Transformer belting with 50 x 50 x 6 mm.angle with two cross fixing channels |
| 561 | Clamp for h-beam size- ,wt-3.2 kg using 65x8 ms flat(1Set=2Nos.) |
| 562 | Stay set 20 mm. painted complete with turn buckles |
| 563 | Stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set ) |
| 564 | Stone block/pre cast block for base pedding 450x450x75mm |
| 565 | Concreting of h-beam @ 0.70 cmt. Per pole with muffing (1:3:6) |
| 566 | Concreting of stay @ 0.2 cmt. Per stay (1:3:6) |
| 567 | Acsr conductor rabbit for jumper |
| 568 | Danger boards enamalled type 11kv |
| 569 | Bi-metallic clamps Distribution Transformers Bushing HT side |
| 570 | Bi-metallic clamps suitable for 12mm dia stud LT side |
| 571 | Anti climbing devices (barbed wire 2.24 mm dia (14 swg) (3.5 kg. Wire per pole) |
| 572 | Red oxide paint |
| 573 | Aluminium paint |
| 574 | M.s.nuts and bolts |
| 575 | Distribution box mounting channel (75x40x6 mm.) |
| 576 | L.t. distribution box suitable for 63 kva transformer (without tpn switches) with mccb on incoming and pf units on outgoing side made of smc |
| 577 | LT 50 sq.mm.,3.5 core xlpe armoured aluminium conductor cable |
| 578 | LT Al Lugs 50 sqmm |
| 579 | 11 kV, A.B. switch, 400A with complete fitting |
| 580 | DTR S/s fencing of 6' height with chain link fencing on MS Angle (50x50x6mm) support 7 Nos. 7' height with Double Gate |
| 581 | Earthing with G.l. earth pipe 4.5 mtrs long & 40 mm dia with masonary enclosure on the top etc as reqd. for Earthing of DTR |
| 582 | Supply and Laying of UG LT XLPE 300 sqmm Cable inside Bodhjungnagar IE for new feeders up to 3.5KM |
| 583 | Supply of 3 phase 3.5 core LT xlpe 300 sqmm al power cable |
| 584 | Laying of 3 phase 3.5 core LT xlpe 300 sqmm al power cable in trench 350 mm x 1200 mm, sand cushioning 250x350 sqmm, brick protection 120 sqmm |
| 585 | Excavation of cable entry pit through hdpe pipe pe80 pn 6, 400 mm od |
| 586 | Supply and erection of p80. Pn6, 400 mm od hdpe pipe |
| 587 | Gi / hdpe pipe for raiser up to 400 sqmm |
| 588 | Coiling of excess 300 sqmm cable in pit size 2250 x 2250 sqmm minimimum by brick laying and 300 mm fine sand / Duct |
| 589 | Outdoor cable termination with heat shrinkable jointing kit 300 sqmm(1Set=3 Nos.) |
| 590 | Route marker complete |
| 591 | LT danger plate |
| 592 | Ms nuts & bolts assorted size |
| 593 | Bi metallic lugs 300sqmm |
| 594 | 8 swg gi wire |
| 595 | Route survey of existing line and proposed network |
| 596 | Feeder pillars complete |
| 597 | Supply and Laying of UG LT XLPE 185 sqmm Cable inside Bodhjungnagar IE for new feeders up to 3.5KM |
| 598 | Supply of 3 phase 3.5 core LT xlpe 185 sqmm al power cable |
| 599 | Laying of 3 phase 3.5 core LT xlpe 185 sqmm al power cable in trench 350 mm x 1200 mm, sand cushioning 250x350 sqmm, brick protection 120 sqmm |
| 600 | Excavation of cable entry pit through hdpe pipe pe80 pn 6, 400 mm od |
| 601 | Supply and erection of p80. Pn6, 400 mm od hdpe pipe |
| 602 | Coiling of excess 185 sqmm cable in pit size 2250 x 2250 sqmm minimimum by brick laying and 300 mm fine sand / Duct |
| 603 | Outdoor cable termination with heat shrinkable jointing kit 185 sqmm(1Set=3 Nos.) |
| 604 | Route marker complete |
| 605 | LT danger plate |
| 606 | Ms nuts & bolts assorted size |
| 607 | Al metallic lugs 185 sqmm |
| 608 | 8 swg gi wire |
| 609 | Route survey of existing line and proposed network |
| 610 | Feeder pillars complete |
| 611 | Supply and Installation of Street Light LED Lamps on Street Light Poles up to 16KM & Dismantling of existing network of Street Light |
| 612 | Full GI Tubular Pole 11 m Long |
| 613 | Clamps / Arm Brackets / fixing arrangement for Street Light fittings suitable for LED Fixture |
| 614 | Concreting of pole @ 0.50 cmt. per pole with muffing (1:3:6) |
| 615 | Earthing Coil ( coil of 115 turns of 50 mm.dia. and 2.5 Mtrs. lead of 4.0 mm. G.I wire) |
| 616 | Supply and Installation LED Lamp Fitting, for Street Light 100 Watt, with polycarbonate glass cover with IP66 enclosure and complete fittings and connection from Pole PVC LT Junction Box |
| 617 | 3 Core 1.5 sq mm unarmoured Cable for Pole JB to Street Light connection |
| 618 | LT Junction Box PVC Type |
| 619 | Supply and Laying of Street Light Cable Core 3.5 Core 50 sq mm armoured for loop in loop out connection |
| 620 | 75 mm HDPE Pipe pipe PN6 for laying of cable |
| 621 | Supply and fixing of Post Top LED lamp in main gate with GI Pipe and loop box LED Lamp 45 Watt |
| 622 | Timer Switch for street light switching |
| 623 | Excavation for pipe/cable laying |
| 624 | Route Survey |
| 625 | Dismantling Cost of Street light up to 15KM within IE AreaDismantling of Street Light Network, Conductor, and Pole and fixtures & fittings: Existing Line inside IE |
| 626 | Supply and Installation of High Mast Lighting |
| 627 | Supply of 20 M high mast shaft suitable for 39 m/sec wind speed, with all accessories including foundation bolts, aviation light, feeder pillar & suitable as per illumination design Wiring material,power cables between panel and mast, MCB in base compartment are Nos.t included & shall be in the scope of erection. |
| 628 | Supply of Nos.n-integral floodlight luminaries LED 250 Watts, 8 Nos. in each pole HPI/T Plus lamps and its control gear boxes. |
| 629 | Provision of GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. (2Nos. per mast required) |
| 630 | Power and Control Panel Outdoor and Environment Protection |
| 631 | Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour. |
| 632 | Erection and Commissioning of the high mast with all wiring materials. |
| 633 | Environment management plan |
| 634 | Testing of environmental parameter (Ambient Air Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Once before construction and Construction phase-36 months of 2 locations, once a quarter (18 samples) of two sector/Component |
| 635 | Testing of environmental parameter (Water Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Once before construction and Construction phase-36 months of 2 locations, once a quarter (18 samples) of two sector/Component |
| 636 | Testing of environmental parameter (Ambient Noise Level) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Once before construction and Construction phase-36 months of 2 locations, once a quarter (18 samples) of two sector/Component |
| 637 | Testing of environmental parameter (Soil Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Once before construction and Construction phase-36 months of 1 locations, once a quarter (18 samples) of two sector/Component |
| 638 | Testing of environmental parameter (Ambient Air Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 2 locations, once in 6 months (20 samples) of four sector/Component of two sector/Component |
| 639 | Testing of environmental parameter (Water Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 2 locations, once in 6 months (20 samples) of two sector/Component |
| 640 | Testing of environmental parameter (Ambient Noise Level) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 2 locations, once in 6 months (20 samples) of two sector/Component |
| 641 | Testing of environmental parameter (Soil Quality) within IE through NABL/MoEFCC Accredited Laboratory. Monitoring locations shall cover all active construction sites, workforce camp site, material stack yard for Maintenance/ DLP phase- 60 months of 2 locations, once in 6 months (20 samples) of two sector/Component |
| 642 | Operation & Maintaince |
| 643 | 1st year |
| 644 | 2nd year |
| 645 | 3rd year |
| 646 | 4th year |
| 647 | 5th year Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysOct 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender