Tender For annual repair & maintenance of Building In Bm-Pk Division During 2026-27.Sh:-Repairing, Rewinding And Other Allied Works Of Pump Sets At Humayun Lane Service Centre.
Tender Value
6.45 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
6 days left
EMD
12908
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for annual repair & maintenance of Building In Bm-Pk Division During 2026-27.Sh:-Repairing, Rewinding And Other Allied Works Of Pump Sets At Humayun Lane Service Centre.
BOQ
| Sl. No. | Item Description |
| 1 | Lifting and taking out and installation after repairing up to 10 HP sewage drainage and clean water submersible drainage and clean water submersible pump tube well etc with the help of chain pully and tripot delivery pipe line and electric connection etc as per the direction of engineer – in – charge. |
| 2 | Repairing / overhauling Mono submersible pump set kiloskar make 1440 RPM & replacement & ball bearing 2 nos (6305,6205) part plate 1 no. gland bush 1 no. , gland plate 1 no, gland stud 2 nos, impellor key 1 no. impellor nut 1 no, impellor key way balancing gland dori with greasing, nut bolt stud, pump shaft welding turning glading cartage site to workshop & back at site including dismantling the pump set and reinstallation of pump set as per the direction of the engineer- in- charge. |
| 3 | Rewinding of AC 5 HP motor mono block pump set 3 phase 440 volt 2800/2900 RPM with superior copper wire appropriate size including testing etc as per the direction of engineer-in-charge. |
| 4 | Providing and fixing cast iron impellor suitable for 5 HP to 10 HP motor pump set as per the direction of engineer – in – charge. |
| 5 | Providing and fixing ball bearing SKF/NBC make in existing motor pump set including greasing , cleaning and sitting in the position (main and bearing) for up to 10 HP motor pump set. |
| 6 | Labour charge for dimantling and installation after repairing the pump set at site and cartage at site to workshop and back at site incluing section and delivery connection three phase connection testing etc as per the direction of engineer in charge. |
| 7 | Providing and fixing overloaded relay with 9-14 Amp to 28-42 Amp automatic starter including labour charges for fixing the over load relay cartage etc. as per the direction of Engineer-in-charge. |
| 8 | Providing and fixing 25 AMP Contractor of make L&T / BCH for DOL starter / star delta fully automatic stater including labour charges for fixing the contractor cartage etc. as per the direction of engineer-in-charge. |
| 9 | Providing and fixing single face preventer of L&T / MINILAC make sutable up to 15 HP pump set incluidng fixing charges cartage etc. as per the direction of engineer-in - charge. |
| 10 | Providing and fixing electic timer type ET 100 L&T or equivalent make for star delta fully starter 3-10 secs to 9-30 sec range operating voltage 230/440 volt CAT No. SS91270 including cartage, labour charges for dismantling of old timer and fixing of new timer including electric connetion testing etc as per the direction of engineer in charge. |
| 11 | Providing and fixing gun metal sleeve graphic cotton of required size in pump set including gland packing (dori) 3 HP to 5HP pump set. |
| 12 | Providing and fixing rubber gasket one set of approved quality in pump set up to 10 HP monoblock pump set suction and delivery pipe line complete as per direction of engineer – in – charge. |
| 13 | Providing and fixing electronic motor fan for up to 10 HP motor pump set as per the direction of engineer – in – charge. |
| 14 | Providing and fixing metal sheet fan guard upto 10HP motor pump set compatible with existing motor including nuts/ studs as required and as per the direction of engineer – in – charge. |
| 15 | Providing and fixing push buttons with element BCH/L&T/FUJI/VAISHNE make 22.5 mm dia including cost of push buttons fixing , cartage & testing as per the direction & entire satisfaction of Engineer-in-charge. |
| 16 | Welding turning threading and alignment of rafter shaft for upto 10 HP pump set as per the direction of engineer – in – charge. |
| 17 | Providing and fixing studs and nuts including making threading in body of pump 12x45 mm as per the direction of engineer – in – charge. |
| 18 | Providing and fixing spare parts of kit (sliver paint) for L&T /BCH make for starter i/c labour charges cartage etc. as per the direction of engineer – in – charge.Spare kit without coil |
| 19 | Overload relay (13-21 AMPERE) |
| 20 | No volt coil (220/415 volt) |
| 21 | Repairing / overhauling 40 HP pump set & replacement of ball bearing 6307/c4/nos, ball bearing 6308 RS 1 No, neck ring 2 nos deflector 2 nos, pump shaft 1 no, mechanical pump seal (TC/TC) 2 nos, 'O' ring 3 nos, bearing housing repairing 2 nos, impellor key 2 nos, nut bolt stud, rubber packing cartage Site to workshop and back to site labour for dismantling and reinstallation of pump set after repairing and minor lath work to match the spare parts including testing commissioning etc as per the direction of engineer in charge. |
| 22 | Rewinding of 40 HP squirrel cage induction horizontal electrical motor of 1450 RPM suitable for operation on 415 Volts, 3 phase, 50 cycle \\"AC supply including providing copper wire of required size dismantling refixing the repair motor on the foudation block making proper alignment with pump, providing and replacing broken nuts and bolts including testing and commissioning etc as per the direction of engineer in charge. |
| 23 | Providing and fixing 3 pole power contractor ML -3 type L&T BCH make with 2 nos+2MC AWC contact on operation 3 phase 440 volts for DOL/ star delta fully automatic starter including cartage, fixing charges eletric connection etc as per the direction of engineer-in-charge. |
| 24 | Providing and replacing volt meter 96x96 mm 0-30 Amp of 0-500 volt of AE (Automatic Electric) seimens or equivalent including cartage, labour charges for dismantling and fixing the Ampere meter and electric connection testing etc as per the directionof engineer in charge. |
| 25 | Providing and replacing AMP meter 96x96 mm 0-30 Ampere of automatic eletric seimens/Havells or equivalent including cartage labour charges for dismantling and re-fixing the AMP meter and electric connection testing etc as per the direction of engineer in charge. |
| 26 | Providing and fixing MCB (Miniature Circuit Breaker) L&T /Fuji/ Havells make including cartage, labour charge for dismantling the old MCB & fixing the new MCB electirc connection testing etc. as per the direction of engineer in charge. 32 Amp (FN/TPN) L&T make |
| 27 | Providing and fixing MCCB (Molded Case Circuit Breaker ) Siemens Sinova/ Schneider Electric's /L&T /Fuji/ make including cartage, labour charge for dismantling the old MCCB & fixing the new MCCB electirc connection testing etc. as per the direction of engineer in charge.100 AMP (FN/TPN) |
| 28 | Providing and fixing 6 sqmm three core water proof PVC insulated copper wire for submersible pumps/ motors etc complete as per the direction of engineer – in – charge. |
| 29 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 50 mm nominal bore Vertical |
| 30 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 80 mm dia |
| 31 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 100 mm dia |
| 32 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 50 mm dia nominal bore. |
| 33 | 100 mm dia submersible pump set of approved make such as KSB Limited (Model: Cora 4C/18 or equivalent) comprising 1,5 HP, 2900 RPM submersible motor suitable for operation on single phase, 415 volts, 50 Hz A.C. supply, having 50 mm dia delivery outlet, complete with pump and motor assembly, suitable for clear water, conforming to the following duty conditions: Discharge – 95 LPM at 48 m head, Discharge – 70 LPM at 70 m head, Discharge – 50 LPM at 93 m head, including all necessary accessories required for proper functioning, testing and commissioning etc. complete as required. |
| 34 | 3 core x 2.5 sq.mm flat type submersible cable, PVC insulated and PVC sheathed, with copper conductor, water proof, suitable for submersible pump operation, of approved make such as Finolex Cables Ltd / Netco or equivalent |
| 35 | Purchase & taken away the dismantled material by contractor as & where basis for which carriage shall be borne by the contractor himself & against theses materials payment shall be made by the contractor to the department or necessary recoveries shall be made from the bill of contractor.(a) M.S Pipes 80 mm dia |
| 36 | (b) M.S Pipes 100mm dia Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender