Housing Urban and Rular Development Government Departments Closing in 4 days TDR #57717419

Tender For Maintenance Of Street Lights, High Masts On Delhi Pwd Roads Under Pwd M-South Division During 2026-27 (Sh : Supplying, Installation, Testing & Commissioning Of Street Light Poles With All Accessories On Service Road Adjacent To Main Outer

Issued by Government Departments · Delhi, Delhi
Tender Value
24.70 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
4 days left
EMD
49418
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Maintenance Of Street Lights, High Masts On Delhi Pwd Roads Under Pwd M-South Division During 2026-27 (Sh : Supplying, Installation, Testing & Commissioning Of Street Light Poles With All Accessories On Service Road Adjacent To Main Outer Ring Road Iit Flyover To Jia Sarai Fob Under M-South Division)

BOQ

Name of Work:- Maintenance of Street Lights, High Masts on Delhi PWD Roads under PWD M-South Division during 2026-27 (SH : Supplying, installation, Testing & Commissioning of Street Light Poles with all accessories on Service Road Adjacent to Main Outer Ring Road IIT Flyover to Jia Sarai FOB under M-South Division)
Sl. No. Item Description
1Supplying & erection of flange mounted hot dip galvanized octagonal poles of 5 mtrs. height made from 3 mm thick HT steel plate having bottom dia of 130 mm & top dia of 70 mm complete with window with flash cover at a height of 0.5 mtrs from the base for cable termination block etc. and galvanized base plate of size 225 mm x 225 mm x 12 mm thick on the existing cement concrete pedestal as required i/c supplying and fixing of the following in the window box provided for cable termination : a) Supply & fixing 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 Nos. GI strip 4 mm thick of suitable length and having suitable size tapped holes - 10 Nos as reqd.b) Supply and fixing 63 amps. terminal block suitable for 25 sq. mm conductor- 4 Nos. & shorting links - 5 Nos. on DIN channel i/c pdg. and fixing DIN channel of suitable length - 1 Nos. on the existing laminated sheet. c) Supply & fixing of 6 amp. SP MCB 'C' characteristics Curve - 1 Nos, earth stud - 1 Nos, welded at suitable height two nos washers, springs washers & nuts. d) Cable support clamp sutiable for 4 Nos. of 4 x 16 sqmm cable.
2Providing and laying in position 1:2:4 reinforced cement foundation of size 450mm x 450mm x 800mm deep i/c excavation of earth, providing , cutting, bending and placing in position, 8 nos. reinforcement of cold twisted bars of 12mm dia-860mm long (NS) - & 4 nos. reinforcement ring of cold twisted bar of 8mm dia - 1800mm (NS) equally distanced in lenth of vertical bar as required with positioning of foundation bolts and providing 40 mm (O.D.) DWC, HDPE Pipe of 0.3 mtrs. length for cable entry & exit i/c dismantling of the existing damaged foundation and dispose of the malba at suitable location etc as reqd. (For 3 mtr & 4 mtr. pole)
3Supplying and fixing 4 Nos. 20 mm dia X 750mm long Gl foundation bolt (EN8 grade) with nuts. washer including 2 Nos. template of 3mm thick size 225 x 225 mm with 4 nos. 16 mm dia holes, to match with PCD of Pole base plate as reqd.
4Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection,EMIEMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K /4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
5120 watt
6Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.5.01) 63 mm dia (OD-63 mm & ID-51 mm nominal)
7Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
8Fabricating supplying and fixing wiremesh frame work made out of 40x40x6mm thick angle iron having 40x6mm flat strip & wiremesh 6 swg dia m.s wire with 25mmx75mm space in between mesh & top covered for rain protection by 16 SWG MS Sheet and making main door gate having suitable locking arrangement with godown lock (Frame size shall not be more than 60 cm x 90 cm) i/c grouting with cement concrete & primer and spray painting with super synthetic enamel paint of approved colour quality etc as reqd.
9Supplying and Laying of XLPE insulated and PVC sheathed aluminium conductor armoured Power Cable of 1.1 KV grade of following size In HUME/ DWC Pipe/ Metal Pipe/ RCC Pipe etc. as required.
104 X 16 Sq. mm.
113.5 X 50 Sq. mm.
12Supplying and drawing following size of PVC insulated Aluminium conductor multicore cable in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable lugs connections etc. as reqd.
133 core 2.5 sq.mm Al cable
14Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
15Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
16Dismantling the existing cement concrete path and laying of cement concrete 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size i/c making good the same after proper finishing the path etc complete as reqd.
17Fabrication, Installation, Testing and Commissioning of floor mounting double door minimum 300 mm depth with locking arrangement front and rear openable, totally enclosed, compartmentalized, dust, vermin proof and outdoor type Feeder Pillar (IP54) fabricated out of 2mm thick cold rolled carbon annealed sheet steel, (minimum) surface area 1.50 Sq.Mtr, with 300 Amp 4 strip AL. bus bar, cable alley on both sides, powder coated paint of approved shade after 7 tank cleaning process and 1 no 20x3mm GI strips throughout the width of feeder pillar consisting two earth studs on each strip complete with provision for incoming and outgoing switchgears including making connections/ inter connections with lugs/ thimble for switchgears and control wiring with 2.5 sq.mm PVC insulated FRLS copper conductor cable, including providing 50mm X 50mm X 6 mm thick (NS) 90 cm long legs out of which 45 cm duly grouted in existing cement concrete 1:2:4 etc complete as reqd.(Drawing shall be got approved from Engineer-incharge before fabrication)
18Incomer:-
19200A TP 25KA MCCB WITH SPREADER LINK (Ics=100%Icu) : 01 No.
20Metering:-
21DIGITAL AMMETER (0-200) WITH SELECTOR SWITCH: 01 No.
22DIGITAL VOLT METER (0-500) WITH SELECTOR SWITCH : 01 No.
23INDICATION LED LAMP RYB : 03 No.
242A SP MCB : 03 No.
25200/5A CT CLASS-1: 03 No.
26Out going :-
27100A TP 16KA MCCB WITH SPREADER LINK (Ics=100%Icu) : 03 Nos
28110A TP POWER CONTACTOR 220V: 01 No.
29DIGITAL TIMERS: 01 No.
30Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required: 01 Set
31Providing and laying in position 1:2:4 cement concrete feeder pillar/panel foundation of required size i/c excavation & refiling of earth, providing and placing in position legs of feeder pillar grouted in CC etc complete as reqd. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57717419
AUTHORITY Government Departments
TENDER VALUE 24.70 Lakhs
LAST DATE 01-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Maintenance Of Street Lights, High Masts On Delhi Pwd Roads Under Pwd M-South Division During 2026-27 (Sh : Supplying, Installation, Testing & Commissioning Of Street Light Poles With All Accessories On Service Road Adjacent To Main Outer Ring Road Iit Flyover To Jia Sarai Fob Under M-South Division)
Basic Detail
Tender No 76/EE(E)/EMD South Elect. Divn./PWD/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 25 Sep 2026
Submission Date 01 Oct 2026
Open Date 01 Oct 2026
Finance
Tender Value 24.70 Lakhs
Tender Fee Ref. Documents
EMD 49418
Exemption Not Available
Document List
28636daa-0f3e-42f7-9448-ea9f60d8e303.html
BOQ_398977.xls
NIT.pdf
Tendernotice_1 (21).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

28636daa-0f3e-42f7-9448-ea9f60d8e303.html

xls

BOQ_398977.xls

pdf

NIT.pdf

pdf

Tendernotice_1 (21).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders