Public Administrative Department Local Bodies Closing in 5 days TDR #57717332

Tender For Provision Of Centralized Air Conditioning System In Community Center In 7-Block Trilokpuri, Community Center In 17-Block Trilokpuri And Khel Parisar 9-Block Trilokpuri In Ac-55 Under Shahdara South Zone

Issued by Local Bodies · Delhi, Delhi
Tender Value
1.15 Crore
Estimated cost
Bid Submission
05 Oct 2026
5 days left
EMD
2.41 Lakhs
Bank guarantee accepted
Document Fee
1770
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of Centralized Air Conditioning System In Community Center In 7-Block Trilokpuri, Community Center In 17-Block Trilokpuri And Khel Parisar 9-Block Trilokpuri In Ac-55 Under Shahdara South Zone

BOQ

Name of Work:- Provision of centralized Air Conditioning system in Community Center in 7-Block Trilokpuri, Community Center in 17-Block Trilokpuri and Khel Parisar 9-Block Trilokpuri in AC-55 under Shahdara South Zone
Sl. No. Item Description
1Supplying, Installation, Testing and Commissioning of air cooled ducted split type air conditioning machine with each having a capacity and details as mentioned below suitable for operation on R 32/R-410A /R-407 Green refrigerant comprising of Scroll type compressor hermatically sealed complete with automatic capacity, safety switches, lubrication system with min 5 year (OEM) warranty for both compressor and Printed Circuit Board (PCB) , Suitable capacity squirrel cage induction motor having class 'B' insulation suitable for operation on 415 + 10% volts, 50 Hz, A.C. supply for Blower motor, Necessary drive arrangement for blower motor, Matching Air cooled condenser with necessary fittings for refrigerant piping connections, necessary structural support for mounting condensers, Microprocessor based control panel complete with accessories, machine Isolation / disconnect switch, valves and accessories to inter connect compressor and condenser including pressure testing, vacuum. Necessary starters suitable for Indoor & outdoor unit complete with O/L ,U/V, phase reversal protection, single phase preventors i/c copper conductor control and power cable and drain pipe of suitable size and length etc complete as required. The total cooling capacity/heating capacity of tested unit shall have a capacity as per relevant IS code. The lab testing reports as per IS: 8148 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per ISO/International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification as required 16.7 TR (nominal) DUCTABLE Type
2Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : (a)28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
3(b)15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge 40 mm nominal dia Pipes
5Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
6Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
7Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required. (a) Thickness 0.63 mm sheet
8(b) Thickness 0.80 mm sheet
9Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing ductafter applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19 mm thick.
10Supplying and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminium sheet fixed to inside surface of ducts with cadmium plated nuts,bolts, stick pins, CPRX compound in confirmation to SMACNA/IS and as per specifications complete etc. as required.
11Supplying, Fixing, testing and commissioning of fire dampers of minimum 90 minutes fire rated in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal and, in confirmation to IS and as per specifications complete etc. as required. (a) fire damper
12Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required.
13Supplying, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required.
14Supplying, Fixing, installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required.
15Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
16Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB
17Supply of XLPE insulated and PVC Sheathed Al conductor armoured cable 1.1 KV grade conforming to IS-7098 (P-I) as required.4C*95 Sqmm
18Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp
19Supply of XLPE insulated and PVC Sheathed Al conductor armoured cable 1.1 KV grade conforming to IS-7098 (P-I) as required.4C*35 Sqmm
20Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size wall surface as reqd. Upto35 sq. mm (clamped with 1mm thick saddle)
21Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.400 A,50KA,FPMCCB
22Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.250 A,36KA, FPMCCB
23SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection, erection of switchgears with depth 30 cm to 60 cm and making provisions for termination of incoming/ outgoing cables/ bus ducting and making foundation etc as required. (Suitable for 400 Amp TP & N)
24Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
25Providing and fixing 6 SWG dia GI Wire on surface or in recessed for loop earthing as required.
26Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57717332
AUTHORITY Local Bodies
TENDER VALUE 1.15 Crore
LAST DATE 05-10-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Provision Of Centralized Air Conditioning System In Community Center In 7-Block Trilokpuri, Community Center In 17-Block Trilokpuri And Khel Parisar 9-Block Trilokpuri In Ac-55 Under Shahdara South Zone
Basic Detail
Tender No EEE-I/2026-27/8.2
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 25 Sep 2026
Submission Date 05 Oct 2026
Open Date 05 Oct 2026
Finance
Tender Value 1.15 Crore
Tender Fee 1770
EMD 2.41 Lakhs
Exemption Not Available
Document List
390c41e6-f81d-47e9-b09e-834697a35d55.html
BOQ_340848.xls
condition_2.pdf
Tendernotice_1.pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Oct 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

390c41e6-f81d-47e9-b09e-834697a35d55.html

xls

BOQ_340848.xls

pdf

condition_2.pdf

pdf

Tendernotice_1.pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders