Tender For Estimate For The Work Repair , Maintenance, Replacement And Providing Of Electrical Fittings And Other Electrical Fittings And Other Electrical Works In Mc S La
Tender Value
21.38 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
5 days left
EMD
42775
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jhajjar → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Estimate For The Work Repair , Maintenance, Replacement And Providing Of Electrical Fittings And Other Electrical Fittings And Other Electrical Works In Mc S La
BOQ
| Sl. No. | Item Description |
| 1 | Estimate for the work Repair , maintenance, replacement and providing of electrical fittings and other electrical fittings and other electrical works in MC Sampla |
| 2 | Supplying, installation, Testing and Commissioning of Panel light 2x2 ft., of following bodymaterial and construction as per IS : 10322 with driver as per the requirement with Driverefficiency )85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temprange -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Opencircuit protection,THD ( 10% , P. F.=0.95, IP20, CRI )80, UGR (Unified Glare Rating) (19, Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitry),of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard DeviationColor Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing on housing.complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copperconductor single core cable and earthing etc. as required with Minimum 5 year OEMwarranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report fromNABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement: heat sink of aluminum housing such that LED junction temperature shallnot rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness = 1.20 mm) 36 watt |
| 3 | Supplying, installation, Testing and Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency )85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP-66,IK-10, CRI )80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) 135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).150 watt |
| 4 | Supplying, installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , Flicker free (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) 36 watt |
| 5 | Supply, erection, testing of wall fans IS marked with suitable erection arrangement complete in all respects complete as per directions of Engineer-in-charge |
| 6 | Supply and erection of wi-fi router double anteena type for providing internet connection complete in all respects complete as per directions of Engineer-in-charge |
| 7 | repair / replacement of solar connector and fault detection of 15 kw solar system complete in all respects complete as per directions of Engineer-in-charge |
| 8 | Providing net meter and connection for existing solar of 15 kw with necessary connections complete in all respects complete as per directions of Engineer-in-charge |
| 9 | providing and fixing of invertor 48 volt above or equal to 2 kva complete in all respects complete as per directions of Engineer-in-charge |
| 10 | supply and erection of ongrid invertor of 15 kva with necessary connections complete in all respects complete as per directions of Engineer-in-charge |
| 11 | supply and erection of Automatic Panel for generator ( as per generator specification ) complete in all respects complete as per directions of Engineer-in-charge Please Enable Macros to View BoQ information |
| 12 | Estimate for the work Repair , maintenance, replacement and providing of electrical fittings and other electrical fittings and other electrical works in MC Sampla |
| 13 | Estimate for the work Repair , maintenance, replacement and providing of electrical fittings and other electrical fittings and other electrical works in MC Sampla Complete in all respect. |
AI Tender Summary
Tender Timeline
Sep 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender