BOQ
| Sl. No. | Item Description |
| 1 | Dismantling Brick work including labours as per direction of departmental officers., |
| 2 | Dismantling AC Sheet Roofing without Roof Timbers including labours etc |
| 3 | Cement Concrete Broken Stone in Cement mortar 1:4:8 mix using 40mm metal granite stone etc complete., |
| 4 | Brick work in cement mortar 1:5 mix using Fly Ash bricks of 230x110x70mm (8 3/4\\" x 41/4\\" x23/4\\") including cost of materials and labour charges etc., as per standard specification - 1m3 |
| 5 | Plastering for brickwork and concrete surfaces using cement mortar 1:5 (One part of cement, five parts of sand by volume) thickness 12mm (average) for all internal/external surfaces like superstructure, rainwater ducts, elevation |
| 6 | Painting with plastic emulsion paint in two coats over a base coat of Primer in approved colour and quality etc., complete. |
| 7 | Flooring finishing with first quality design ceramaic tiles of all colours of size 305cm X 305cm X 6mm laid in cement mortar 1:3 mix to 20mm thick and painting with white cement using 0.30 kg/1m2 including finishing the jointing and painting flush with tiles surface etc., complete - 10 m2 |
| 8 | Paving the floor with vitrified Floor Tiles of size 60 x 60 cm. of approved brand and colour Marbonite tiles in all floors base layer of cement mortar 1:3 (one cement and three sand) 20mm thick using first quality Marbonite tiles of size 60x60 cm and point with colour cement neatly and fixed in position so as to make perfectly smooth and to alignment etc. complete complying with standard specification. |
| 9 | S/F of MS Truss with purlins including all labours and transports charges as per direction of departmental officers., |
| 10 | POLYURETHANE FOAM THERMAL INSULATION PANELS (PUF)Providing and Fixing of polyurethane foam as External Wall Thermal insulation panels or Sandwich insulated panels with external 0.30mm total coated thickness pre painted galvalume sheet with micro ribbed profile, whereas internal 0.30mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free , high performance rigid olyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessoriessuch as screws ,fastners ,sealants etc for fixing the panel etc., complete complying with standard specification. |
| 11 | Supplying and fixing in position best white glazed earthernware Oriya type Indian water closet of approved quality of size 550 mm x 440 mm with 'P' or 'S' trap and embedding the closet with trap to shape in position with 40mm brick jelly lime concrete 1:2:5 etc., complete |
| 12 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC light point / fan point (for electronic regulator) |
| 13 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x 75mm MS switch box inflush with wall with 3mm thick hylum sheet cover for 5A 3pin non interlocking flush type CS plug with painting of suitable colour with continuous earthwire connection of 14SWG TC wire for open plug point |
| 14 | Supply and fixing of single box type 4'40W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals to the fitting |
| 15 | Supply and fixing of 1200mm (48\\") sweep AC ceiling fan complete with stepped electronic 300W regulator with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18\\") |
| 16 | Supplying and fixing of position of Indian make white glazed earthwere wash basin 550mm x 400mm with all accessories such as cost Iron brackets, 32mm dia C.P. 1 Waste coupling, coupling, Rubber plug and chain, 32mm dia 'B' class, G.I. Waste pipe, 15mm dia, G.M.Wheel valve, 15mm dia Nylon connection, 15mm dia Brass Nipples, 15mm C.P. pillar tap etc., |
| 17 | Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc., |
| 18 | Painting and lettering for Child education and awareness in the wall, using standard paints, necessary colour pigments, including cost of all materials & Labour charges etc complete |
| 19 | Supplying and fixing of Cudappa slab of 40mm thick for Cup board including cost of materials and labour etc complet Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysOct 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender