Public Administrative Department Government Departments Closing in 0 days TDR #57713952

Tender For General-Electrification , Providing Cctv , Air Conditioning , Tv At By Standers Waiting Area , Near Emergency Medicine , Medical College , Thiruvananthapuram -Electrification , Providing Cctv , Air Conditioning , Tv At By Standers Waiting

Issued by Government Departments · Thiruvananthapuram, Kerala
Tender Value
8.76 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
0 days left
EMD
21904
Bank guarantee accepted
Document Fee
1935
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for General-Electrification , Providing Cctv , Air Conditioning , Tv At By Standers Waiting Area , Near Emergency Medicine , Medical College , Thiruvananthapuram -Electrification , Providing Cctv , Air Conditioning , Tv At By Standers Waiting Area , Near Emergency Medicine , Medical College , Thiruvananthapuram-General Electrical Work

BOQ

Name of Work:- GENERAL-Electrification , Providing CCTV , Air Conditioning , TV at By Standers Waiting Area , Near EMERGENCY MEDICINE , MEDICAL COLLEGE , THIRUVANANTHAPURAM -Electrification , Providing CCTV , Air Conditioning , TV at By Standers Waiting Area , Near EMERGENCY MEDICINE , MEDICAL COLLEGE , THIRUVANANTHAPURAM-General Electrical Work
Sl. No. Item Description
1Electrification , Providing Air Conditioning at By Standers Waiting Area , Near EMERGENCY MEDICINE , MEDICAL COLLEGE , THIRUVANANTHAPURAM
21.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
31.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
41.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
51.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
61.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
71.50.1:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
81.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
91.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
101.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
111.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A
122.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
132.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
142.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
152.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
161.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
171.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1890.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
195.6:Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2090.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
211.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
2290.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
23OD421826/2025-2026:Supply and Fixing of 32A Neutral Link
24OD421831/2025-2026:Supply and Fixing of 32 A Fuse unit
2590.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
2690.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
271.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
281.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
292.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
30OD421840/2025-2026:Supply and Fixing of 100A , 2Way Neutral Links mounted on DMC/SMCbase
31OD421845/2025-2026:Supply and Fixing of LED Type Bulk Head Light Fittings
321.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
3390.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
34OD421838/2025-2026:Supply and Installation of Heavy Duty Exhaust fan 18inch, 450mm, 1400rpm
3590.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
36OD421847/2025-2026:Supply and fixing Analogue time switch suitable for 1 output per phase and suitable for single phasesupply including necessary connections as required.
37OD421848/2025-2026:Supply and Fixing of 15 Watts Cealing Light
38OD421841/2025-2026:Providing and Fixing 10W Bulb
3919.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
401.55.1:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
41OD421872/2025-2026:Supply , Conveyance , Installation , Testing and Commissioning of wall mounting type Split Air Conditioner unit conforming to IS fitted with rotory compressor operating on 230/415 V AC supply R410A/non CFC refrigerant Capable of performing functions like cooling , dehumidifying , air circulating , filtering etc. of following capacity , microprocessor control with cordless remote control etc , including electric cable , copper pipe and thermal insulation upto 4M as required with minimum One year on site warranty , 5year compressor warranty and one year free service . 100% copper 1.5 Tr 5 Star 1 phase Inverter type Split AC unit (Blue Star/DAIKIN /VOLTAS / equivalent make of PWD approved with ISI )
42OD421884/2025-2026:Supplying and fixing of extra Soft drawn 22G Copper tube for suction and discharge suitable for the split AC units with insulation including cost of materials and labour etc (for 1.5Ton AC)
43OD421885/2025-2026:Supply and fixing of Suitable Heavy duty metallic Body Voltage stabilizer 4KVA with voltage range of 175-275V and output range of 210-240V for 1.5Ton Split AC unit etc wall
4490.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
4590.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
461.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
472.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
48OD421943/2025-2026:Supply and Fixing of 100A HRC Fuse Base with HRC Fuse Link Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57713952
AUTHORITY Government Departments
TENDER VALUE 8.76 Lakhs
LAST DATE 01-10-2026
Authority
Authority Name Local Self Government Department
Work Description Tender for General-Electrification , Providing Cctv , Air Conditioning , Tv At By Standers Waiting Area , Near Emergency Medicine , Medical College , Thiruvananthapuram -Electrification , Providing Cctv , Air Conditioning , Tv At By Standers Waiting Area , Near Emergency Medicine , Medical College , Thiruvananthapuram-General Electrical Work
Basic Detail
Tender No DB/62983/2026-27(82)
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 25 Sep 2026
Submission Date 01 Oct 2026
Open Date 03 Oct 2026
Finance
Tender Value 8.76 Lakhs
Tender Fee 1935
EMD 21904
Exemption Available
Document List
8d2b82a2-903a-4f0c-9d17-6afc140f1dbc.html
BOQ_1480287.xls
Tendernotice_1 (22).pdf
Tendernotice_2.pdf
Tendernotice_3 (1).pdf
Tendernotice_4.pdf
Tendernotice_5.pdf
viewnit.pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Oct 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

8d2b82a2-903a-4f0c-9d17-6afc140f1dbc.html

xls

BOQ_1480287.xls

pdf

Tendernotice_1 (22).pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3 (1).pdf

pdf

Tendernotice_4.pdf

pdf

Tendernotice_5.pdf

pdf

viewnit.pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders