Tender For Rate Contract For Fpfdrlky; Esa Lfkkfir Central Air Conditioner Model Kws095. 12X2 (Extended Upto 95.12 Ton) Dk Okfkzd Lapkyu ,Oa Ejeer Dk Dk;Z Gsrq Fufonk
Tender Overview
Project Description
Tender for Rate Contract For Fpfdrlky; Esa Lfkkfir Central Air Conditioner Model Kws095. 12X2 (Extended Upto 95.12 Ton) Dk Okfkzd Lapkyu ,Oa Ejeer Dk Dk;Z Gsrq Fufonk , Supply And Replacement Of Condensor Assembly Below Necessary Items As Required , Condenser Assembly, C1609- 2A , Refrigerant Gas, Hcfc-22 , Evd Evalution Lan Protocol , Flow Switch, , Pco5 Plus Hs Medium Board Controller , Expansion Model K-Smart Controlle , Sensor Temp. Ntc , Pwc Power Contactor 230V 3Tf50 , Transducer Pressure, K- Smart Controller 44.8B , Pw Power Contactor|230V Ac, 70A, 3Tf47 72-0Ap0 , Valve Safety, Set periodical renewal - 13 Bar, Size - 1/2 Npt(M) X 3/4 , Transducer Pressure(10B) , Lubricating Oil Screw Compressor. , Filter Drier Core, Model No. 48Dc , Gasket, Od 128 X Id 115 X 1.6 Thk, Moc - Nam Af-159 , Txv Valve , Charges For, Civil Work , Charges For, Fabrication Work , Descaling For Condenser For Chiller , Service Charges For Reparing Of Kirloskar Make Chiller , Charges For, Dismantle Of Old Condenser , Installation Of New Condenser Flushing With N2 , Leakage Testing With N2 Pressure Testing, Vacuumization, Dehydration Work , Of Chiller At Site. , S&F Of Ahu (Motor With Blower) , S&F Of Ahu Motor , S&F Of Expansion Valve , S&F Of Controller (K-Smart) Pco5 + Hs Medium Board Controller , S&F Of Ct Pump , S&F Of Condensor Pump , S&F Of Contactor Auxulliary , P & Replacement Of Ahu Door , S&F Of Aluminum Duct With Insulation As Required Size (Per Feet) , Contactor 110 A With Auxiliary Block , Contactor 40 A With Auxiliary Block , Contactor 32 A With Auxiliary Block , M.C.B. 32 A , Indicator Lamp , Hwg Element (86Kw) , Hwg Thermostat , Butter Fly Valve , A) Butter Fly Valve 200 Mm , B) Butter Fly Valve 150 Mm , C) Butter Fly Valve 50 Mm , S & F Bearing , S & F Mechanical Seal Set , C.H.& Cd Pump Winding , Ahu Motor Winding , Fan Belt , U Band Pipe With Meter , De Scaling Of Condenser Job Covers F) Opening Of The Condenser Side Covers G) Hcl Acid And Inhibitor Circulation H) Tube To Tube Roding I) Cleaning Of Tubes (180 No) J) Re Fixing Of Condenser Water Boxes , Ct Fan Motor Winding , Ct Fan Motor , Pipe Line Color Per Sq. Feet , N.R.V. Valve 8 , Air Valve , Push Button , Volt Meter 400V , Oil Paper , Rubber Sheet , Hot Water Generator Mcb 160 A , Hot Water Generator Thermostat , Sensor Chiller Temperature , Gas R22 (Per Kg) , Compressor Oil , High Pressure Seat , Not Bolt Varies Size Tvs , A Meter , V Meter , Cleaning Of Cooling Coils Of Ahu , Change Of Actuator Motor With Valve , Replacement Of Canvas In Ahu , Insulation Of Ahu Line On Ot , Replacement Of Header Pipe Of Cooling Tower , Replacement Of All Fills Eliminators, Pvc Pipe Headers And Nozzles Of Cooling Tower , Replacement Of Fan Motor Bearing Of The Cooling Tower , Main Body Of Cooling Tower , Replacement Of Water Filter , Seizing Of Copper Tube , Fuse 160 Amp. , P & R Of M.S. Chennel (50X50x5 Mm.) Per Kg. , P & R Of M.S. Angle Per Kg. , Replacement Of M.S. Pipe (In Let & Out Let) Water Per Kg With Colour , Operation And Maintenance (Ac) , Fpfdrlky; Esa Lfkkfir Central Air Conditioner Model Kws095 .12X2 (Extended Upto 95.12 Ton) Dk OkfKzd Lapkyu ,Oa Ejeer Dk Dk;Z Gsrqa ¼01 OKz Ds Fy,S½
BOQ
| Sl. No. | Item Description |
| 1 | Supply and replacement of Condensor Assembly below necessary Items as Required |
| 2 | CONDENSER ASSEMBLY, C1609- 2A |
| 3 | REFRIGERANT GAS, HCFC-22 |
| 4 | EVD EVALUTION LAN PROTOCOL |
| 5 | FLOW SWITCH, |
| 6 | PCO5 PLUS HS MEDIUM BOARD CONTROLLER |
| 7 | EXPANSION MODEL K-SMART CONTROLLE |
| 8 | SENSOR TEMP. NTC |
| 9 | PWC POWER CONTACTOR 230V 3TF50 |
| 10 | TRANSDUCER PRESSURE, K- SMART CONTROLLER 44.8B |
| 11 | PW POWER CONTACTOR|230V AC, 70A, 3TF47 72-0AP0 |
| 12 | VALVE SAFETY, SET PR - 13 BAR, SIZE - 1/2\\" NPT(M) X 3/4\\" |
| 13 | TRANSDUCER PRESSURE(10B) |
| 14 | LUBRICATING OIL SCREW COMPRESSOR. |
| 15 | FILTER DRIER CORE, MODEL NO. 48DC |
| 16 | GASKET, OD 128 X ID 115 X 1.6 THK, MOC - NAM AF-159 |
| 17 | TXV Valve |
| 18 | Charges for, civil work |
| 19 | Charges for, Fabrication Work |
| 20 | Descaling for condenser for chiller |
| 21 | SERVICE CHARGES FOR REPARING OF KIRLOSKAR MAKE CHILLER |
| 22 | Charges for, dismantle of old condenser , installation of new condenser flushing with N2 , leakage testing with N2 Pressure testing, Vacuumization, Dehydration work , of chiller at site. |
| 23 | S&F of AHU (Motor with Blower) |
| 24 | S&F of AHU Motor |
| 25 | S&F of Expansion Valve |
| 26 | S&F of Controller (K-Smart) PCO5 + HS Medium Board Controller |
| 27 | S&F of CT Pump |
| 28 | S&F of Condensor Pump |
| 29 | S&F of Contactor Auxulliary |
| 30 | P & Replacement of AHU Door |
| 31 | S&F of Aluminum duct with Insulation as required size (per feet) |
| 32 | Contactor 110 A with auxiliary block |
| 33 | Contactor 40 A with auxiliary block |
| 34 | Contactor 32 A with auxiliary block |
| 35 | M.C.B. 32 A |
| 36 | Indicator Lamp |
| 37 | HWG Element (86KW) |
| 38 | HWG Thermostat |
| 39 | Butter Fly Valve |
| 40 | a) Butter Fly Valve 200 mm |
| 41 | b) Butter Fly Valve 150 mm |
| 42 | c) Butter Fly Valve 50 mm |
| 43 | S & F Bearing |
| 44 | S & F Mechanical Seal Set |
| 45 | C.H.& CD Pump Winding |
| 46 | AHU Motor Winding |
| 47 | Fan Belt |
| 48 | U Band Pipe With Meter |
| 49 | De scaling of Condenser Job Coversf) Opening of the Condenser Side Coversg) HCL Acid and inhibitor Circulation h) Tube to tube Roding i) Cleaning of Tubes (180 no)j) Re fixing of Condenser Water Boxes |
| 50 | CT Fan Motor Winding |
| 51 | CT fan Motor |
| 52 | Pipe Line Color Per Sq. Feet |
| 53 | N.R.V. Valve 8\\" |
| 54 | Air Valve |
| 55 | Push Button |
| 56 | Volt Meter 400V |
| 57 | Oil Paper |
| 58 | Rubber Sheet |
| 59 | Hot Water Generator MCB 160 A |
| 60 | Hot Water Generator Thermostat |
| 61 | Sensor Chiller Temperature |
| 62 | Gas R22 (per kg) |
| 63 | Compressor Oil |
| 64 | High Pressure Seat |
| 65 | Not Bolt Varies Size TVS |
| 66 | A Meter |
| 67 | V Meter |
| 68 | Cleaning of Cooling Coils of AHU |
| 69 | Change of Actuator Motor with Valve |
| 70 | Replacement of canvas in AHU |
| 71 | Insulation of AHU Line On OT |
| 72 | Replacement of Header Pipe of Cooling Tower |
| 73 | Replacement of all Fills eliminators, PVC pipe headers and nozzles of Cooling Tower |
| 74 | Replacement of fan Motor bearing of the cooling tower |
| 75 | Main Body of Cooling Tower |
| 76 | Replacement of Water Filter |
| 77 | Seizing of copper tube |
| 78 | Fuse 160 Amp. |
| 79 | P & R of M.S. Chennel (50x50x5 mm.) per Kg. |
| 80 | P & R of M.S. Angle Per Kg. |
| 81 | Replacement of M.S. Pipe (in let & out let) water per KG with Colour |
| 82 | Operation and Maintenance (AC) |
| 83 | fpfdRlky; esa LFkkfir Central Air Conditioner Model KWS095 .12X2 (Extended Upto 95.12 Ton) dk okf\\"kZd lapkyu ,oa ejEer dk dk;Z gsrqA ¼01 o\\"kZ ds fy,s½ Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender