Housing Urban and Rular Development Boards / Undertakings / PSU Closing in 15 days TDR #57707957

Tender For Fire Fighting Work In Five Community Health Centre (Aliganj, Sakit, Marhera, Jaithara & Jalesar) At Etah.

Issued by Boards / Undertakings / PSU · Etah, Uttar Pradesh
Tender Value
7.51 Crore
Estimated cost
Bid Submission
20 Oct 2026
15 days left
EMD
15.10 Lakhs
Bank guarantee accepted
Document Fee
8850
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Etah → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Fire Fighting Work In Five Community Health Centre (Aliganj, Sakit, Marhera, Jaithara & Jalesar) At Etah.

BOQ

Name of Work:- FIRE FIGHTING WORK IN FIVE COMMUNITY HEALTH CENTRE (ALIGANJ, SAKIT, MARHERA, JAITHARA & JALESAR) AT ETAH.
Sl. No. Item Description
1Fire Alarm System : (CHC ALIGANJ)
2Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.
3Two Loop
4Supplying, installation, testing & commissioning of intelligent analog addressable photothermal (Smoke) detector complete with mounting base complete as required.
5Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
6Supplying, installation, testing & commissioning of fault isolator complete with base as required.
7Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
8Supplying, installation, testing & commissioning of addressable fire control module complete as required.
9Supplying, installation, testing & commissioning of addressable phone control module complete as required.
10Supplying, installation, testing & commissioning of addressable manual call point complete as required.
11Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
12Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
13Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
14Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
15Public Addressable System :
16Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
17Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
18Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
19Supplying, installation, testing & commissioning of digital audio amplifier 500 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
20Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
21Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size includingconnections and interconnections etc. as required.
2217.5.3.1 speaker cable Single pair, 2-core, 1.5 sqmm
23Supply and fixing of 25mm dia medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
24PUMP ROOM (CHC ALIGANJ)
25(a) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in allrespects, as required :(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal asrequired.(c) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018.(d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e)Suitable cement concrete foundation duly plastered with anti vibration pads.
261620 lpm at 70 m Head
27(a) Supplying, installation, testing and commissioning of diesel engine driven main firepump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel DrivenPump)(b) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal as required. (c) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pumphouse duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.(d)M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads.
281620 lpm at 70 m Head
29(a) Supplying, installation, testing and commissioning of electric driven pressurisationpump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) (b)Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required. (c)Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class 'F' insulation, conforming to IS-12615: 2018. (d)M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads.
30180 lpm at 88 m Head
31Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with.
32INCOMING
33Incomings
34400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A
35Outgoings
36( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)
37Main Fire Pump
38200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.
39Jockey Pump
40100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.
41Diesel Engine Control
42Control for diesel engine comprising -
43Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.
44Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
45150 mm dia
46100 mm dia.
47200 mm dia. (wall thickness 6.3 mm)
48Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required washers etc.as required :
49100 mm dia
50150 mm dia
51200 mm dia
52Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
53200mm dia.
54Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
55200 mm dia.
56150 mm dia.
57100 mm dia.
58Providing and fixing rubber ballow.
59200 mm dia.
60150 mm dia.
61100 mm dia.
62Dial Type pressure guage for (0-16 kg/cm2) with necessary nipple & other fittings, mounting arrangements and with 15 mm ball valve.
63Supplying & fixing air vessel made out of 250 mm dia,8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
64Providing, fixing, testing & commissioning of installation of 150mm dia control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc .
65(External Hydrant) (CHC ALIGANJ)
66Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
67150 mm dia
68Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
69150 mm dia
70Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
71Single headed gun metal
72Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. Please Enable Macros to View BoQ information
73Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57707957
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 7.51 Crore
LAST DATE 20-10-2026
Authority
Authority Name Uttar Pradesh Housing And Development Board
Work Description Tender for Fire Fighting Work In Five Community Health Centre (Aliganj, Sakit, Marhera, Jaithara & Jalesar) At Etah.
Basic Detail
Tender No NIT-901/M-6/ED-III/130 Dated 11/09/2026
Bidding Type Tender
Location
City Etah
State Uttar Pradesh
Key Dates
Publish Date 25 Sep 2026
Submission Date 20 Oct 2026
Open Date 21 Oct 2026
Finance
Tender Value 7.51 Crore
Tender Fee 8850
EMD 15.10 Lakhs
Exemption Available
Document List
45926845-0f7c-44da-958b-abddc12060c5.html
BOQ_2237079.xls
TENDERCHCETAH.pdf
Tendernotice_1 (78).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Oct 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

45926845-0f7c-44da-958b-abddc12060c5.html

xls

BOQ_2237079.xls

pdf

TENDERCHCETAH.pdf

pdf

Tendernotice_1 (78).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender