Tender for Tender for Rate Contract For Manifold System Lmo, Central Air And Central Sunction, Psa Plant (500Lpm Unissi) And O And M For 1 Year
Tender Overview
Project Description
Tender for Rate Contract For Manifold System Lmo, Central Air And Central Sunction, Psa Plant (500Lpm Unissi) And O And M For 1 Year
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-Sep-2026 | Correct Tender Documents | Technical Bid | 05-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | REPAIR AND MAINTENANCE ITEM |
| 2 | WALL MOUNTING TYPE GAS MANIFOLD FABRICATED WITH 5/8''X 15 SWGCOPPER PIPE & BRASS BLOCKSVAS PER EQUALLY SPACEDAT 250MM FITTED ON BLACK PAINTED ANGLE MS FRAME (50X50X6)HYDRAULICALLY TESTED AT 300 BAR WITH HIGH PRESSURE NON RETURNVALVE & 1.25 METER LONG 5/16'' X 16G COPPER TAIL PIPE TESTED AT 300 BAR FOR OXYGEN/NITROUS OXIDE 7/CARBON-DI-OXIDE TO BE FITTEDWITH SEMI AUTOMATIC CONTROL PANEL SYSTEM |
| 3 | HIGH PRESSURE NON RETURN VALVE (NRV) FOR MANIFOLD |
| 4 | TAIL PIPES: |
| 5 | 1.25 METER LONG 3/8''X16G COPPER TAIL PIPE WITH GAS SPECIFIC BRASSEND FITTINGS FOR O2/N2O/CO2/AIR/NITROGEN |
| 6 | 1.25 METER LONG FLEXIBLE SS BRADED TAIL PIPE WITH DETACHABLE GASSPECIFICEND FITTING TESTED AT 250 BAR FOR O2/N2O/AIR/NITROGEN |
| 7 | SEMI AUTOMATIC CONTROL PANEL |
| 8 | SEMI AUTOMATIC CONTROL PANEL FOR OXYGEN/N2O/CO2 |
| 9 | FULLY AUTOMATIC CONTROL PANEL FOR O2/ N2/ CO2 |
| 10 | MOX REGULATORS |
| 11 | SINGLE STAGE AND SINGLE GAUGE MOX-REGULATOR FOR CO2(SSSG) |
| 12 | SINGLE STAGE AND DOUBLE GAUGE MOX-REGULATOR FOR CO2(SSDG) |
| 13 | DOUBLE STAGE AND DOUBLE GAUGE MOX-REGULATOR FOR CO2(DSDG) |
| 14 | MEDICAL GAS OUTLET/PARKODEX OUTLET WITH PROBLE FOROXYGEN/VACUUM/AIR/NITROUS OXIDE FOR: |
| 15 | WALL MOUTING |
| 16 | PANEL MOUTING |
| 17 | PANDENT MOUTING |
| 18 | PLASTIC COVER FOR PARKODEX OUTLET |
| 19 | PARKODEX PROBE FOR OXYGEN (3/8) |
| 20 | PARKODEX PROBE FOR O2/VAC/AIR/N2O/ (HOSE) |
| 21 | MEDICAL GAS OUTLET/PURITAN BANETT OUTLET (AMERIACN OUTLET) WITH PROBE FOR OXYGEN/VACCUM/AIR/NITROUS OXIDE FOR: |
| 22 | WALL MOUTING |
| 23 | PANEL MOUTING |
| 24 | PANDENT MOUTING |
| 25 | PLASTIC COVER FOR PARKODEX OUTLET |
| 26 | PB PROBE FOR OXYGEN (3/8) |
| 27 | PB PROBE FOR O2/VAC/AIR/N2O/ (HOSE) |
| 28 | MEDICAL GAS OUTLET/BRITISH SANDARD OUTLET WITH PROBE FOR OXYGEN/VACCUM/AIR/NITROUS OXIDE FOR: |
| 29 | WALL MOUTING |
| 30 | PANEL MOUTING |
| 31 | PANDENT MOUTING |
| 32 | PLASTIC COVER FOR PARKODEX OUTLET |
| 33 | BS PROBE FOR OXYGEN (3/8) |
| 34 | BS PROBE FOR OXYGEN/VAC/AIR/N2O/ (HOSE) |
| 35 | ALARMING SYSTEMS: |
| 36 | SINGLE GAS AUDIO PIPE LINE ALARM WITH CONNECTOR |
| 37 | SINGLE GAS MICROPROCESSOR CONTROLLED ALARM WITH ANALOGINDICATION FOR LOW/NORMAL PRESSURE WITH BUZZER FACILITY |
| 38 | SINGLE GAS MICROPROCESSOR CONTROLLED ALARM WITH ANALOGINDICATION FOR LOW PRESSURE WITH MUTE/TEST FACILITY |
| 39 | 2 GAS MICROPROCESSOR CONTROLLED ALARM WITH ANALOG PRESSUREINDICATION FOR LOW PRESSURE & HIGH PRESSURE WITH MUTE/TEST FACILITY |
| 40 | 3 GAS MICROPROCESSOR CONTROLLED ALARM WITH ANALOG PRESSUREINDICATION FOR LOW PRESSURE & HIGH PRESSURE WITH MUTE/TEST FACILITY |
| 41 | 4 GAS MICROPROCESSOR CONTROLLED ALARM WITH ANALOG PRESSUREINDICATION FOR LOW PRESSURE & HIGH PRESSURE WITH MUTE/TEST FACILITY |
| 42 | 5 GAS MICROPROCESSOR CONTROLLED ALARM WITH ANALOG PRESSUREINDICATION FOR LOW PRESSURE & HIGH PRESSURE WITH MUTE/TEST FACILITY |
| 43 | 6 GAS MICROPROCESSOR CONTROLLED ALARM WITH ANALOG PRESSUREINDICATION FOR LOW PRESSURE & HIGH PRESSURE WITH MUTE/TEST FACILITY |
| 44 | AREA ZONAL VALVE BOX: |
| 45 | 2 GAS ZONEL VALVE BOX |
| 46 | 3 GAS ZONEL VALVE BOX |
| 47 | 4 GAS ZONEL VALVE BOX |
| 48 | 5 GAS ZONEL VALVE BOX |
| 49 | 6 GAS ZONEL VALVE BOX |
| 50 | ISOLATIN VALVE & BRASS FITTING: |
| 51 | 12 MM ISOLATION VALVE WITH NUT/NIPPLE ADOPTER |
| 52 | 13 MM ISOLATION VALVE WITH NUT/NIPPLE ADOPTER |
| 53 | 22 MM ISOLATION VALVE WITH NUT/NIPPLE ADOPTER |
| 54 | 28 MM ISOLATION VALVE WITH NUT/NIPPLE ADOPTER |
| 55 | WARD ACCESSORIES: |
| 56 | F.A VALVE WITH HUMIDIFIER BOTTLE (SAFETY VALVE) |
| 57 | BPC FLOW METER |
| 58 | HUMIDIFIER BOTTLE WITH SAFETY VALVE |
| 59 | RANGE (0-760 mm Hg) SUCTION REGULATOR WITH GAUGE DIAL 50mm |
| 60 | SUCTION 600 ML POLYCARBONATE JAR |
| 61 | SUCTION 1000 ML POLYCARBONATE JAR |
| 62 | SUCTION 2000 ML POLYCARBONATE JAR |
| 63 | THEATRE SUCTION TROLLY SS TYPE WITH 2 NOS 2000 ML POLYCARBONATE JARS & SUCTION REGULATOR DIAL 50MM RANGE (0-760 mm Hg) WITH SELECTOR SWITCH |
| 64 | HP TUBES |
| 65 | HIGH PRESSURE TUBE FOR O2/N2O/AIR/VAC/CO2/AIR7 |
| 66 | LOW PRESSURE TUBE FOR O2/N2O/AIR/CO2/AIR7 |
| 67 | SADDLE:PLASTIC SADDLE WITH MOULDED BRASS INSERT WITH COVER & MS SCREWFOR:- |
| 68 | 12 MM SADDLE |
| 69 | 15 MM SADDLE |
| 70 | 22 MM SADDLE |
| 71 | 28 MM SADDLE |
| 72 | 35 MM SADDLE |
| 73 | 42 MM SADDLE |
| 74 | 54 MM SADDLE |
| 75 | 76 MM SADDLE |
| 76 | COPPER PIPE 12 MM |
| 77 | COPPER PIPE 15 MM |
| 78 | COPPER PIPE 22 MM |
| 79 | SUCTION JAR WITH REGULATOR 60 ML |
| 80 | OXYGEN SUPPLY REGULATOR |
| 81 | AIR FILTER |
| 82 | AIR SOLNET WALL |
| 83 | AIR PRESSOR SIWCH |
| 84 | AIR COMPRESSOR O RING |
| 85 | EACH JOINT WELDING SERVICE CHARGE |
| 86 | COPPER T 15 MM |
| 87 | COPPER ELBOW 15 MM |
| 88 | COPPER SOCKIT 15 MM |
| 89 | MANIFOLD PANEL O RING SET |
| 90 | OUT LET PIONT O RING SET |
| 91 | SUCTION MACHINE OIL |
| 92 | SUCTION MACHINE MOTOR RIBINING |
| 93 | NRV in Suction Machine 40 mm |
| 94 | Dual Starter 3 phase |
| 95 | V Belt for Suction Motor |
| 96 | Pressure Switches |
| 97 | Operation and Maintenance (Oxyten Plant) |
| 98 | ,l-vkj-th- fpfdRlky; esa LFkkfir Manifold System, LMO, lsUVªy ,;j ,oa lsUVªy lD”ku] PSA Plant (500 LPM) lapkyu gsrq 24 ?kaVs izf”kf{kr O;fDr }kjk fpfdRlky; iz”kklu ds funZs”ku esa dk;Z djokuk ftls fuEu dk;kZsa dks laikfnr djuk gksxk %& 1. Manifold System esa Hkjs vkWDlhtu vkSj ukbZVªl flys.Mj yxkuk o [kkyh flys.Mj LVksj esa ykSVkus dk dk;ZA 2. lsUVªy ,;j lD”ku e”khuks dks 6 ?k.Vs ds vUrjky esa lapkyu djokuk ¼pykus ls iwoZ pSEcj vkWby fQYVj eksVj LVkVj iw.kZr;k% pSd djus ds mijkUr gh e”khu pkyw djsa½3. fujUrj varjky esa fMLpktZ izs”kj dk yksx cqd la/kkfjr djokbZ tk;sA 4. vfu;af=r /ouh lqukbZ nsus ij rqjUr izhosUVho esUVsusa”k djok;k tk;sA |
| 99 | tukuk fpfdRlky; esa LFkkfir Manifold System, LMO, lsUVªy ,;j ,oa lsUVªy lD”ku lapkyu gsrq 24 ?kaVs izf”kf{kr O;fDr }kjk fpfdRlky; iz”kklu ds funZs”ku esa dk;Z djokuk ftls fuEu dk;kZsa dks laikfnr djuk gksxk %& 1- Manifold System esa Hkjs vkWDlhtu vkSj ukbZVªl flys.Mj yxkuk o [kkyh flys.Mj LVksj esa ykSVkus dk dk;ZA 2- lsUVªy ,;j lD”ku e”khuks dks 6 ?k.Vs ds vUrjky esa lapkyu djokuk ¼pykus ls iwoZ pSEcj vkWby fQYVj eksVj LVkVj iw.kZr;k% pSd djus ds mijkUr gh e”khu pkyw djsa½3- fujUrj varjky esa fMLpktZ izs”kj dk yksx cqd la/kkfjr djokbZ tk;sA 4- vfu;af=r /ouh lqukbZ nsus ij rqjUr izhosUVho esUVsusa”k djok;k tk;sA |
| 100 | ,l-vkj-th- fpfdRlky; esa LFkkfir dksfoM gkWfLiVy ¼U;w bejtsUlh vks-Vh-½ esa LFkkfir Manifold System, lsUVªy ,;j ,oa lsUVªy lD”ku lapkyu gsrq 24 ?kaVs izf”kf{kr O;fDr }kjk fpfdRlky; iz”kklu ds funZs”ku esa dk;Z djokuk ftls fuEu dk;kZsa dks laikfnr djuk gksxk %& 1- Manifold System esa Hkjs vkWDlhtu vkSj ukbZVªl flys.Mj yxkuk o [kkyh flys.Mj LVksj esa ykSVkus dk dk;ZA 2- lsUVªy ,;j lD”ku e”khuks dks 6 ?k.Vs ds vUrjky esa lapkyu djokuk ¼pykus ls iwoZ pSEcj vkWby fQYVj eksVj LVkVj iw.kZr;k% pSd djus ds mijkUr gh e”khu pkyw djsa½3- fujUrj varjky esa fMLpktZ izs”kj dk yksx cqd la/kkfjr djokbZ tk;sA 4- vfu;af=r /ouh lqukbZ nsus ij rqjUr izhosUVho esUVsusa”k djok;k tk;sA Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 9 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender