Tender For Special Repair To Boiler Of 850 Kg/Hr Capacity Of Engine Division At 3 Brd Under Ge (Af) Mc Chandigarh
Tender Value
24.25 Lakhs
Estimated cost
Bid Submission
17 Oct 2026
17 days left
EMD
48500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Boiler Of 850 Kg/Hr Capacity Of Engine Division At 3 Brd Under Ge (Af) Mc Chandigarh
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning of package type LDO Fired designed low pressure steam generator 850 kg per hr capacity, Steam temperature 180 degree C with a maximum working pressure rating of 15 kg/Cm2 including one No. pressure part assembly consisting of closely wound helical vertical coil fabricated out of seamless pipes with spacers of special design, one in No. down firing pressure jet burner assembly, one No. double jacket air casing to enclose the pressure parts and serve as an integral combustion air Preheater along with specially designed aluminium radiator to minimise radiation losses and maximize efficiency, one in No. specially designed shell and tube type atmospheric economizer at the flue gas outlet of boiler to preserve heat and optimize the efficiency of Boiler. The steam generator should have comprised with the following standard fittings /Technical specifications:-(a) Capacity of the Steam Generator - 850 Kg/Hr(b) Maximum Working Pressure - 15 Kg/Cm2(c) Fuel used - LDO(d) Electric Supply - AC, 3 Phase, 415 V, 50 Hz, 4 wire System(e) Four-Pass design with economizer (f) Reverse flue design(g) High Combustion efficiency(h) Easy access for inspection and cleaning(j) Fully automatic unit(k) Low system lag and rapid warm up response(l) Insulated body to minimise radiation losses(m) Instant steaming |
| 2 | Steam Generator to be tested at factory and FAT shall be validated by GE complete and undertake the testing of individual of system as prescribed in tender along with composite testing of overall system and issue the testing and quality confirmation certificate for the safe and quality installation and submission of FAT certificate to be made to department for acceptance along with steam generator and site testing will be undertaken with following tests:-(a) Ensure all components of the system are clean and free from foreign matter.(b) Mechanical check shall be carried out on the system to ensure all the components are correctly installed and ready for use.(c) General connection, inspection on supply piping, ignition system, safety shutdown device function test etc.(d) Fuel supply line condition check(e) Pump control function test(f) Control test for safety devices (g) Water chemical test, water level control test, feed system control test, loop test (on open circuit) for each of the circuit to be carried out at site. Please Enable Macros to View BoQ information |
| 3 | Steam Generator to be tested at factory and FAT shall be validated by GE complete and undertake the testing of individual of system as prescribed in tender along with composite testing of overall system and issue the testing and quality confirmation certificate for the safe and quality installation and submission of FAT certificate to be made to department for acceptance along with steam generator and site testing will be undertaken with following tests:-(a) Ensure all components of the system are clean and free from foreign matter.(b) Mechanical check shall be carried out on the system to ensure all the components are correctly installed and ready for use.(c) General connection, inspection on supply piping, ignition system, safety shutdown device function test etc.(d) Fuel supply line condition check(e) Pump control function test(f) Control test for safety devices (g) Water chemical test, water level control test, feed system control test, loop test (on open circuit) for each of the circuit to be carried out at site. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysOct 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender