Tender For Provision Of Transformesr With Lt Panels And Other Allied Works At Zonal Office Building 16, Rajpur Road Under Civil Line Zone.
Tender Value
1.93 Crore
Estimated cost
Bid Submission
10 Oct 2026
10 days left
EMD
3.86 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Transformesr With Lt Panels And Other Allied Works At Zonal Office Building 16, Rajpur Road Under Civil Line Zone.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface I recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group C |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 3 | (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 A switch |
| 5 | (b) 3 pin 5/6 A socket outlet |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 7 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (a) Upto 450 mm sweep |
| 8 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 9 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (a) 400 A, 50KA, FPMCCB |
| 10 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) (A) 8 way , Double door |
| 11 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissionino etc. as required. (a) Single Pole |
| 12 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioninq etc. as required. (b) 63 A |
| 13 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 14 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 15 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2. 7 metre Iona etc. with charcoal/ coke and salt as required. |
| 16 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G. I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 17 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 18 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (a) Above 185 sq. mm and upto 400 sq. mm |
| 19 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1 .1 KV grade of following size in the existing masonry open duct as required. (a) Upto 35 sq. mm |
| 20 | (b) Above 185 sq. mm and upto 400 sq. mm |
| 21 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (a) Upto 35 sq. mm (clamped with 1 mm thick saddle) |
| 22 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 3½ X 400 sq. mm (82mm) |
| 23 | (b) 4 X 25 sq. mm (28mm) |
| 24 | (c) 4 X 50 sq. mm (35mm) |
| 25 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 3½ X 240 sq. mm |
| 26 | (b) 3½ X 400 sq. mm |
| 27 | (c) 4 X 25 sq. mm |
| 28 | (d) 4 X 50 sq. mm |
| 29 | Excavation for cable trenches in soft soil, depth upto 1.2 m including cum dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 30 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 31 | Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level : (a) 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 32 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (a) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 33 | Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. |
| 34 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (a) Hot finished welded type tubes |
| 35 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 36 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (a) In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. |
| 37 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (a) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 38 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (a) 1.00 mm thick with zinc coating not less than 275 gm/m² |
| 39 | 12 mm cement plaster of mix : (a) 1:4 (1 cement: 4 fine sand) |
| 40 | White washing with lime to give an even shade : (a) New work (three or more coats) |
| 41 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 42 | Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. |
| 43 | Supplying, installation, testing and commissioning of following capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, KNAN [K(K-Class insulating liquid) Natural Air Natural] copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better),Dielectric material shall be type -A, suitable for out door / indoo applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, |
| 44 | including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safetytripping, complete with all accessories and safety provisions as per relevant IS 1180 (Part-3) including first filling of filtered dehydrated Synthetic organic Ester oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 (Part-3) and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with +12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 40 0C for oil and 45 0C for winding up to 200 KVA and 45 0C for oil and 50 0C for winding for above 200 KVA. Inside of |
| 45 | tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS:1180 (Part 3) shall be referred for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 0C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminium/ stainless steel material securely fixed on the outer body, easily accessible, as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked. |
| 46 | Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steelwith plug for three phase transformers; g)Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); |
| 47 | n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1 600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. (a) 1000 KVA |
| 48 | Supply, Installation, testing and commissioning of HYBRID APFC Panel, 3 phase 4 wire, 415 V, 50 Hz AC System for Ambient temperature -5°C to +40°C of following capacity with passive solution of 60% capacity and active solution of 40% capacity, 3Phase 4 wire Hybrid Power Factor Correction Solution (with arrangment for neutral current balance) to achieve >0.99 lag and TDDI/THDV values within IEEE recommended limits.APFC should be designed as per IS 16636 Or IEC 61921. The active section and passive section shall work in sync to give optimized output. The degree of protection of passive section should be IP 42, and of active section should be minimum IP 21.The switching device for APFC passive section should be through capacitor dutycontactor and for the active compensation system shall be IGBT based with 3 level topology having 12 IGBT in inverter circuit. The active compensation system should filter harmonics from 2nd to 50th individual harmonic order and shall be selectable for the entire range. The active compensation system should have feature to improve PF correction and |
| 49 | harmonic filtration having response time < 100 Micro second. The hybrid panel shall be indoor type floor mounted free standing totally enclosed, extensible, fabricated in compartmentalised designed made of CRCA sheet steel of 2.0mm thick for framework & covers, 3 mm thick for gland plate i/c cleaning & finishing complete with 9 tank process for powder coated of approved shade ( RAL 7032-Siemens gray or as approved by Engineer-in-Charge), having front section (switch gear and control accessories) and rear section (capacitor and reactor), front and rear access, having suitable current carrying capacity, extensible TPN Aluminium alloy bus bar of high conductivity, DMC/SMC bus bar supports, bottom base channel of MS Section, fabrication shall be done in transportable section, entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation |
| 50 | for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with 14% detuned reactor and heavy duty 525 V ISI marked ImpregnatedMPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 & 2) APFC Panel shall be in compliance with IS :16636 & CPWD Specifications etc. as per below details.(A) Incomers Suitable capacity MCCB/ACB (Upto 300 KVAR, MCCB and above 300 KVAR, ACB ) Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED Indicating Lamp set alongwith required Instruments and accessories with extended rotary handel and door interlocking arrangment. Current rating of the Incomer in ampere shall be APFC Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating. (B) Instruments & Indications a) For Passive Section : i) 3-Phase current sensing APFC microprocessor relay/controller , advance 12/16 stages (12 stages for over all capacity of panel (active + passive) below 500 KVAR and 16 stages 500 KVAR & above) and having |
| 51 | display of Phase wise V, A, PF, Cos-Phi, KW, KVA, KVAR, THD-V , THD-I, harmonics up to 31 level. ii) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual mode. iii) Digital Multi function meter with LED Display for V, A, PF, KW, KVA, KVAR, THD-V & I, Frequency. iv) Suitable rating control transformer shall be provided for control and indication circuit. v) All components like control transformer, meter, relay and indicating lamp shall be protected by using suitable rating individual MCB's. vi) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS/HFFR 1100 V grade, PVC insulated multi stranded copper control wire. vii) Communication Ethernet/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. b) For Active Section : Dedicated HMI (Human Machine Interface) (Minimum 7 inch display) for controlling and communication and having display of Phase wise V, A, PF, Cos-Phi, KW, KVA, KVAR, THD-V , THD-I, harmonics up to 50th level. Communication Ethernet / RS485 / SNMP port open protocol for BMS integration as per approved by Engineering in charge. (a) 400 KVAR |
| 52 | LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing |
| 53 | complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) (C) 36 Watt |
| 54 | Brush Less Direct Current (BLDC) Fan with Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. (c) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 55 | Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Ratingof KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, |
| 56 | 50% RH & at 1000 Meter MSL, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. (B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage |
| 57 | indication (vi) RPM indication (vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication(x) Fuel Level (C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. (D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with |
| 58 | necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. (E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. (F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. (G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH |
| 59 | capacity lead acid SMF type) as required asper specifications. The battery shall be housed inside the acoustic enclosure of DG Set. (H) Acoustic and weather proof enclosure witharrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection / connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications. (I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by- |
| 60 | pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication / Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate |
| 61 | capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2. Auto/Manual/Test/Off selector switch 3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF. 6. LED Indicating lamps for load on mains and load on set 7. Fuse/ MCB for instruments 8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. 9. Main supply failure monitor 10. Supply failure |
| 62 | timer 11. Restoration timer 12. Control unit with three impulse automatic engine start/stop and failure to start lockout. 13. Impulse counter with locking and reset facility. 14. ON/OFF/Control circuit switch with indicator 15. Audio/Video annunciation for (i) High water temperature(ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning 16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitablenumber of relays and accessories 17. Maintenance notification based on Engine RunHour & due date. 18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus couplerswitching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring. (a) 500KVA |
| 63 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm |
| 64 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*25 sqmm |
| 65 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*50 sqmm |
| 66 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*240 SQMM |
| 67 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*400 SQMM |
| 68 | supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged) |
| 69 | Providing and fixing ABC (aluminium phosphate) power type fire extinguisher of 6kgs capacity complete in all respect with ISI marked i/c fixing arragement etc as required. |
| 70 | Supply of corrugated & chequered rubber mat for electrical purposes exceeding IS:5424/69 Black or Red in 1 M x 2 M of size. (a) 25 mm thickness |
| 71 | Hiring of silent Diesel Generating set 250 kVA D.G.set complete with power feeding accessories should be suitable to generate 415V +-5% Valts 3p. 50Hz A.C. supply, CPCB IV+ compliant, for the pumping station / temporary sites for a period of 1 month including to and fro charges of 250kVA D.G. set |
| 72 | Supply of 18\\" (450mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as required. |
| 73 | S,I,T,C of MV cubical type Panel suitable for 415 Volt, 3 Phase, 4 wire, 50Hz AC supply system fabricated in compartmentalized design from CRCA sheet steal of 2mm thick (2075 X 6000 X 1200 mm aprox) for frame work and covers 3mm thick for gland plates i/c cleaning & finishing floor mounted complete with 7 lank process for powder coating in approved shade, having 2000 Amps extensible type FP Aluminum Alloy bus bars of high conductivity DMC/SMC bus bar supports, with short circuit with stand capacity of 31 MVA for 1 Sec, bottom base channel of MS section not less than 75mm x 50mm x 6mm thick, fabrication shall be done in transportable section, entire panel shall have a common copper earth bar of suitable size al the rear with 2 Nos, earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 2.5 sqmm PVC Insulated copper conductor single core cable, cable alleys, cable gland plates in two hall, i/c providing and fixing following switch gears. |
| 74 | INCOMER FROM 990KVA TRANSFORMER |
| 75 | 2000A 4P EDO ACB 5OKA Microprocessor Base O/L, S/C & E/F Protection Release-1 no. |
| 76 | ACB Under Voltage Relay-1 no |
| 77 | Micro switch for TRIP Indiration - 1 no |
| 78 | 64 SP 10KA MCB - 6 no |
| 79 | 10A DP 10KA MCB - 2 по |
| 80 | Auxiliary Contactor with 4NO+4NC - 3 no |
| 81 | Digital Multifunction Meter with Rs485 Port EM6436 - 1 no |
| 82 | Under Voltage Relay-1 no |
| 83 | Over Voltage Relay-1 no |
| 84 | Restricted Earth Fault Relay -1 no |
| 85 | Lock Out Relay-1 no |
| 86 | R,Y,B Phase Indicating Lamps - 3 no |
| 87 | ON OFF TRIP Indication Lamps-3 no |
| 88 | Auto manual Selector Switch-1 no |
| 89 | Breaker Control Switch - 1 no |
| 90 | CT's 2000/5A class-1.0 15VA - 3 no |
| 91 | CT's 2000/5A class-PS - 3 no |
| 92 | INCOMER FROM 5OO KVA DG |
| 93 | 1000A 4P EDO ACB 50 KA Microprocessor Base O/L, S/C & E/F Protection Ralese-1 no |
| 94 | ACB Under Voltage Relay - 1 no |
| 95 | Micro switch for TRIP indiration - 1 no |
| 96 | 6A SP 10KA MCB - 6 no |
| 97 | 10A DP 10KA MCB - 2 no |
| 98 | Auxiliary Contactor with 4NO+4NC - 3 no |
| 99 | Digital Multifunction Meter with Rs485 Port EM6436 - 1 no |
| 100 | Under Voltage Relay - 1 no |
| 101 | Over Voltage Relay - 1 no |
| 102 | Restricted Earth Fault Relay 1 no |
| 103 | Lock Out Relay 1 no |
| 104 | Reverse Power Rafay 1 no |
| 105 | R,Y,B Phase Indicating Lamps - 3 no |
| 106 | ON/OFF/TRIP Indication Lamps- 3 no |
| 107 | Auto manual Selector Switch -1 no |
| 108 | Breaker Control Switch - 1 no |
| 109 | CTs 1000/5A class-1.0 15VA - 3 no |
| 110 | CT's 1000/5A class-PS - 3 no |
| 111 | CT's 1000/5A 5P10 - 3 no |
| 112 | INCOMER FROM 250KVA DG |
| 113 | 800A 4P EDO ACB 50KA Microprocessor Base O/L, S/C & E/F Protection Release - 1 no |
| 114 | ACB Under Voltage Relay-1 no |
| 115 | Micro switch for TRIP indication-1 no |
| 116 | 6A SP 10KA MCB - 6 no |
| 117 | 10A DP 10KA MCB - 2 no |
| 118 | Auxiliary Contactor with 4NO+4NC - 3 no |
| 119 | Digital Multifunction Meter with Rs485 Port EM6436 - 1 no |
| 120 | Under Voltage Relay-1 no |
| 121 | Over Voltage Relay-1 no |
| 122 | Restricted Earth Fault Relay-1 no |
| 123 | Lock Out Relay-1 по |
| 124 | Reverse Power Relay-1 no |
| 125 | R,Y,B Phase Indicating Lamps - 3no |
| 126 | ON/OFF/TRIP Indication Lamps-3 no |
| 127 | Auto manual Selector Switch-1 no |
| 128 | Breaker Control Switch-1 no |
| 129 | CT's 800/5A class-1.0.15VA-3 no |
| 130 | CT's 800/5A class-PS - 3 no |
| 131 | CT's 800/5A 5P10 - 3 no |
| 132 | 24VDC Battery Charger-1 no |
| 133 | 16 Window Annaunclator - 1 no |
| 134 | DC Amp Meter 0-30A - 1 no |
| 135 | DC Volt Meter 0-30V - 1 no |
| 136 | 24VDC Auxiliary Relay-2 no |
| 137 | D.G. Start/Stop Push Button-2 no |
| 138 | D.G. Emergency Stop Push Button-1 по |
| 139 | DG SYNCHRONIZING |
| 140 | PLC-1 no |
| 141 | PLC Power Supply-1 no |
| 142 | DG Synchronising Relay-1 no |
| 143 | UPS 1KVA-1 no |
| 144 | Auxiliary Relay Card 24VDC-2 no |
| 145 | Auxiliary Contactor 24VDC with 4NO+4NC-15 no |
| 146 | 6A SP 10KA MCB-4 no |
| 147 | 6A DP 10KA MCB-2 по |
| 148 | Auto manual Selector Switch-1 по |
| 149 | Fault (Red) Indicating Lamps 230VAC-1 no |
| 150 | Reset Push button-1 no |
| 151 | Switch Socket Piano Type-2 no |
| 152 | Axial Fan with Filter-2 no |
| 153 | Inspection Lamps with Door Switch-1 no |
| 154 | BUS COUPLER |
| 155 | 2000A 4P EDO ACB 50KA Microprocessor Base Without Release-1 no |
| 156 | ACB Under Voltage Relay-1 no |
| 157 | 6A SP 10KA MCB-4 no |
| 158 | 10A DP 10KA MCB-2 no |
| 159 | Auxiliary Contactor with 4NO+4NC-4 no |
| 160 | Auto manual Selector Switch-1 no |
| 161 | Breaker Control Switch-1 no |
| 162 | ON/OFF Indication Lamps-2 no. |
| 163 | BUS BAR |
| 164 | 2000A 4P ALUMINIUM BUS BAR |
| 165 | OUTGOING SECTION-1 |
| 166 | 1000A 4P MDO 50KA ACB Microprocessor Base O/L, S/C & E/F Protection Release-1 no |
| 167 | Micro switch for TRIP Indication-1 no |
| 168 | 6A 5P 10KA MCB-1 по |
| 169 | ON/OFF/TRIP Indication Lamps-3 no |
| 170 | 630A 4P 5OKA MCCB Thermal Magnetic Base O/L, S/C Protection Release -3 no |
| 171 | Extended Rotatory Handle, Spreaders-3 no |
| 172 | Aux. Contact + TAC-3 no |
| 173 | 6A SP 10KA MCB-3 no |
| 174 | ON/OFF/TRIP Indication Lamps-9 по |
| 175 | 250A 4P 50KA MCCB Thermal Magnetic Base O/L, S/C Protection Release -2 no |
| 176 | Extended Rotatory Handle, Spreaders-2 no |
| 177 | Aux. Contact TAC-2 no |
| 178 | 6A SP 10KA MCB-2 no |
| 179 | ON/OFF/TRIP Indication Lamps-6 по |
| 180 | OUTGOING SECTION-2 |
| 181 | 400A 4P 50KA MCCB Thermal Magnetic Base O/L, S/C Protection Release -2 no |
| 182 | Extended Rotatory Handle, Spreaders-2 no |
| 183 | Aux. Contact TAC-2 no |
| 184 | 6А SP 10KA MCB-2 по |
| 185 | ON/OFF/TRIP Indication Lamps-6 no |
| 186 | 250A 4P 50KA MCCB Thermal Magnetic Base O/L, S/C Protection Release-4 no |
| 187 | Extended Rotatory Handle, Spreaders-4 no |
| 188 | Aux. Contact TAC-4 no |
| 189 | 6A SP 10KA MCB-4 по |
| 190 | ON/OFF/TRIP Indication Lamps-12 по |
| 191 | S,I,T,C of MV cubical type Panel suitable for 415 Volt, 3 Phase, 4 wire, 50Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick (1875 X 2850 X 1000 mm approx.) for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing floor mounted complete with 7 tank process for powder coating in approved shade, having 800 Amps capacity extensible type FP Aluminum Alloy bus bars of high conductivity DMC/SMC bus bar supports, with short circuit with stand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 75mm x 50mm x 5mm thick, fabrication shall be done in transportable section, entire panel shall have a common copper earth bar of suitable size at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 2.5 sqmm PVC insulated copper conductor single core cable, cable alleys, cable gland plates in two half, i/c providing and fixing following switch gears. |
| 192 | INCOMER |
| 193 | 630A 4P MDO ACB 50KA Microprocessor Base O/L, S/C & E/F Protection Release - 1 no |
| 194 | ACB Under Voltage Relay - 1 no |
| 195 | Micro switch for TRIP Indication - 1 no |
| 196 | 6A SP 10KA MCB - 6 no |
| 197 | 10A DP 10KA MCB - 2 nо |
| 198 | Auxiliary Contactor with 4NO + 4NC - 3 no |
| 199 | Digital Multifunction Meter with Rs485 Port EM6436 - 1 no. |
| 200 | R,Y,B Phase Indicating Lamps - 3 no |
| 201 | ON OFF TRIP Indication Lamps - 3 no |
| 202 | Auto manual Selector Switch - 1 no |
| 203 | Breaker Control Switch - 1 no |
| 204 | CT's 630/5A class-1.0 15VA - 3по |
| 205 | BUS BAR |
| 206 | 800A 4P ALUMINIUM BUS BAR |
| 207 | OUTGOING |
| 208 | 250A 4P 36KA MCCB Thermal Magnetic Base O/L, S/C Protection Release - 4 no |
| 209 | Extended Rotatory Handle, Spreaders - 4 no |
| 210 | Aux. Contact + TAC - 4 no |
| 211 | 6A SP 10KA MCB - 4 по |
| 212 | ON/OFF/TRIP Indication Lamps - 12 no |
| 213 | 200A 4P 36KA MCCB Thermal Magnetic Base O/L, S/C Protection Release - 10 по |
| 214 | Extended Rotatory Handle, Spreaders - 10 no |
| 215 | Aux. Contact + TAC - 10 no |
| 216 | 6A SP 10KA MCB - 10 по |
| 217 | ON/OFF/TRIP Indication Lamps - 30 по Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender