Defence Government Departments Closing in 10 days TDR #57704433

Tender For Repair And Maintenance Of Building Used As Veterinary Hospital Of Bsf C Us Under Shq Bsf Gokulnagar (Sh: electrical installation & Fans)

Issued by Government Departments · Sepahijala, Tripura
Tender Value
1.14 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
10 days left
EMD
2299
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sepahijala → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Building Used As Veterinary Hospital Of Bsf C Us Under Shq Bsf Gokulnagar (Sh: electrical installation & Fans)

BOQ

Name of Work:- Repair and maintenance of building used as veterinary hospital of BSF c us under SHQ BSF Gokulnagar (SH: EI & Fans)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
2Wiring for light/ power plug with 2 x 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
4Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
5Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
6Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
7Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
8Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
9Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
10Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
11Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole-32 amp
12Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).12 way Double door
13Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt ) as required.
14Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
15Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
16Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
17Supplying, Installation, testing and commissioning of 1200 mm 1 star rating, ISI marked double bearing ceiling fan with regulator including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required
18Supplying and fixing G. I. pipe of 40 mm dia (light duty) along the wall / surface for protection of UG cable / lightning conductor etc. as required of ISI marked of make Jindal / Prakash
19Supplying and Laying of one number XLPE insulated and PVC sheathed aluminium armoured power cable of 1.1 KV grade of size 2x25 sqmm sq mm direct in the existing open duct /RCC/ HUME/ METAL pipe as required.
20Supplying and fixing of 9/10W LED batten cool day light complete fitting, box type etc. as required including making connection etc. as required of make Bajaj/ Havells/ Philips/ Crompton. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as required.
21Supplying, Installation, testing and commissioning of 20/22W LED batten cool day light complete fitting, box type etc. as required including making connection etc. as required of make Bajaj/ Havells/ Philips/ Crompton. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as required
22Supplying & fixing of 100 watt LED flood light with aluminium body and toughened glass and secondary optical lens, with IP-66 protection 6500K including bracket for 2 Nos 100 watt flood lights ,wiring with 3 x 1.5 Sqmm (from loop box to LED fitting), PVC insulated & PVC sheathed, multi core, copper condoctor cable & making connection of LED street light luminaire etc. as required of make Havells / Philips/ Suriya/Bajaj.
23Supplying and fixing of 250 mm sweep, PVC exhaust fan suitable for single phase, 50 Hz, 230 volts, AC supply in existing opening including connections etc. as required. Make Havells/Crompton/Usha etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57704433
AUTHORITY Government Departments
TENDER VALUE 1.14 Lakhs
LAST DATE 05-10-2026
Authority
Authority Name Border Security Force
Work Description Tender for Repair And Maintenance Of Building Used As Veterinary Hospital Of Bsf C Us Under Shq Bsf Gokulnagar (Sh: electrical installation & Fans)
Basic Detail
Tender No 04/SHQ/GKNR/AE(E)/NIT/2026-27
Bidding Type Tender
Location
City Sepahijala
State Tripura
Key Dates
Publish Date 25 Sep 2026
Submission Date 05 Oct 2026
Open Date 06 Oct 2026
Finance
Tender Value 1.14 Lakhs
Tender Fee Ref. Documents
EMD 2299
Exemption Not Available
Document List
9d8ce00e-fba5-4f70-9b4e-68722fecb514.html
BOQ_974917.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 25, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Oct 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

9d8ce00e-fba5-4f70-9b4e-68722fecb514.html

xls

BOQ_974917.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail