Tender For Cleaning, Repair/Replacement Of Sewage Lines And Connected Sanitary Works In Otm And Officers Married Accommodation Under Age B/R-Ii At Itarana Cantt, Alwar.
Tender Value
24 Lakhs
Estimated cost
Bid Submission
17 Oct 2026
13 days left
EMD
48000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Alwar → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Cleaning, Repair/Replacement Of Sewage Lines And Connected Sanitary Works In Otm And Officers Married Accommodation Under Age B/R-Ii At Itarana Cantt, Alwar.
BOQ
| Sl. No. | Item Description |
| 1 | M&L for cleaning all blockages of Nahani traps/floor traps, bottle traps and gully traps of any type/size by removing solid/liquid matter, mud, sludge and other deposits from traps and connected CI/PVC waste pipes/bends by manual rodding and/or pressure cleaning pump with flexible rods and other necessary equipment, including hygienic collection and disposal of sludge, by deploying Safaiwala on daily basis for maintenance of internal sewage system in the area of AGE B/R-II, complete all as specified and directed. Note: Contractor/authorised representative shall collect complaints from B/R-II Complaint Cell at 0900 hrs daily except Sundays/holidays without extra cost. Safaiwala shall attend daily with all necessary equipment. Complaints shall be completed within 24 hours, failing which recovery shall be effected as stipulated in the contract. Cleaning of line up to first manhole shall be measured and paid separately under the relevant BOQ item. |
| 2 | All as per preceding item but for cleaning of S-trap/P-trap of WC of any type and size, including removing blockage and thoroughly flushing and washing with water, complete all as specified and directed. |
| 3 | All as per preceding item but for cleaning of wash hand basin and sink of any type and size, including traps and connected waste portion and thoroughly flushing and washing with water, complete all as specified and directed. |
| 4 | M&L for mechanically cleaning manhole chamber of depth n exc 1.00 metre under any condition including foul condition, removing muck, sludge, silt, mud, liquid and other deposits, cleaning inlet and outlet connections, thoroughly washing and flushing manhole with water, replacing cover in position and hygienically disposing sludge/debris outside MoD land in sealed containers/sludge-removal tankers, complete all as specified and directed. |
| 5 | All as per preceding item but for manhole chamber of depth exc 1.00 metre and n exc 3.00 metre, complete all as specified and directed. |
| 6 | M&L for cleaning and dechoking sewer line up to 100 mm bore at all depths by diesel-operated vehicle-mounted hydraulically operated high-pressure suction-cum-jetting sewer cleaning machine having 4000 litres suction capacity and 6000 litres water-jetting tank capacity, including high-pressure jetting system of 2200 PSI, partial desilting of manholes, flushing sewer line from one manhole to another, skilled operator, supervising engineer, labour, fuel and all necessary equipment, complete all as specified and directed. Note: Contractor shall initially clean the complete sewer line within one month of acceptance of tender and thereafter attend blockages as and when reported. |
| 7 | All as per preceding item but for sewer line of 150 mm bore at all depths, complete all as specified and directed. |
| 8 | All as per preceding item but for sewer line of 200 mm to 300 mm bore and depth up to 3.00 metre, complete all as specified and directed. |
| 9 | All as per preceding item but for sewer line of 200 mm to 300 mm bore and depth exc 3.00 metre and n exc 4.50 metre, complete all as specified and directed. |
| 10 | All as per preceding item but for sewer line of 250 mm to 300 mm bore and depth exc 4.50 metre, complete all as specified and directed. |
| 11 | M&L for dewatering manholes of any capacity/depth by using pump set or other approved mechanical means, including pumping out stagnant/sewage water, collecting the same in closed container/tanker and disposing outside Defence land at location as directed, complete all as specified and directed. |
| 12 | M&L for cleaning septic tank/sump of any capacity or description, including pumping out fluid, removing sludge from all compartments and intercepting chamber, thoroughly washing down with water and removing sludge/liquid in covered van/trolley/tanker outside MoD land, complete all as specified and directed. |
| 13 | M&L for cleaning soakage well of any capacity or description, including pumping out fluid, removal of sludge/deposits, washing down with water and removing extracted sludge/liquid in covered van/trolley/tanker outside MoD land, complete all as specified and directed. |
| 14 | M&L for checking and attending complaints of leakage/obstruction in existing PVC/CI soil, waste and vent pipes of any diameter, including attending leaking bends/fittings, clamping vertical stacks, remaking defective joints and carrying out minor repairs/replacement of jointing material necessary to render the system functional and leak-proof, complete all as specified and directed. Note: New pipes, bends, clamps, access doors, cowls and other fittings requiring replacement shall be measured and paid separately under respective BOQ items. Contractor/authorised representative shall collect complaints from B/R-II Complaint Cell daily at 0830 hrs except Sundays/holidays and attend the same within 24 hours with necessary equipment, without extra cost. |
| 15 | M&L for surface dressing n exc 150 mm deep including clearing grass, vegetation, saplings, shrubs, brushwood, undergrowth and roots for making approaches and clearing areas around septic tanks, soak wells, manholes and sewer-line routes, including collecting and removing rubbish to a distance n exc 50 metre and depositing as directed, complete all as specified and directed. |
| 16 | M&L for demolition of brickwork or stone/boulder masonry built in cement mortar or cement-lime mortar, including quoins, arches, pillars and similar work, but excluding ashlar facings, dressed stonework and precast concrete articles, including sorting and stacking serviceable material and disposal of debris, complete all as specified and directed. |
| 17 | M&L for brickwork with old-size sub-class 'B' bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4, complete all as specified and directed. |
| 18 | M&L for half-brick thick wall with old-size fly ash bricks conforming to IS 13757, straight or curved on plan to any radius, built in cement mortar 1:4, complete all as specified and directed. |
| 19 | M&L for walling in random rubble stone masonry, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4, complete all as specified and directed. |
| 20 | All as per preceding random rubble stone masonry item but except stone, using old serviceable stone recovered from demolition, including sorting, cleaning, conveying and incorporating the same in the work, complete all as specified and directed. |
| 21 | M&L for demolition of cement concrete, unreinforced, in ground floor and paving n exc 150 mm thick below or above ground level, including getting out and removing unserviceable material outside MoD land, complete all as specified and directed. |
| 22 | M&L for demolition of reinforced cement concrete of any description and in any position, including cutting reinforcement as necessary to facilitate demolition, getting out material, sorting and stacking recoverable reinforcement and disposal of debris, complete all as specified and directed. |
| 23 | M&L for dismantling existing floor, hearth or wall tiling including cement mortar bedding but not backing, including carefully taking down, sorting and stacking serviceable tiles and removing rubbish from premises, complete all as specified and directed. |
| 24 | M&L for cement concrete 1:2:4 Type B-1 using 20 mm graded crushed stone aggregate as in lintels up to 1.50 metre clear span, cills, steps, seismic and similar bands, plinth/string/lacing courses, parapets and railings up to 600 mm height, copings, kneelers, apex stones, bed plates and similar work, including weathering, rounded/chamfered angles, throating, use and waste of formwork straight or curved and finishing exposed concrete surfaces fair, complete all as specified and directed. |
| 25 | M&L for rendering 15 mm thick in cement mortar 1:4 including approved waterproofing compound on stone/brick masonry surfaces, finished even and smooth without using extra cement, including preparation of surface, scaffolding and working at any height/location, complete all as specified and directed. |
| 26 | M&L for rendering 15 mm thick in cement mortar 1:6 on stone masonry surfaces, finished even and smooth without using extra cement, including preparation of surface, scaffolding and working at any height/location, complete all as specified and directed. |
| 27 | M&L for preparation of newly plastered surfaces and applying three coats of whitewash, including necessary surface preparation, complete all as specified and directed. |
| 28 | M&L for excavation in trenches n exc 1.50 metre wide and n exc 1.50 metre deep for foundations, shafts, walls, manholes and similar work n exc 10 Sqm on plan, getting out excavated material in soft/loose soil, complete all as specified and directed. |
| 29 | All as per preceding excavation item but for depth exc 1.50 metre and n exc 3.00 metre, complete all as specified and directed. |
| 30 | M&L for returning, filling in excavated earth in soft/loose soil, including spreading, levelling, watering and well ramming in layers n exc 250 mm thick, complete all as specified and directed. |
| 31 | M&L for removal of excavated soil/material to a distance n exc 50 metre and depositing where directed at a level n exc 1.50 metre above starting point, complete all as specified and directed. |
| 32 | M&L for demolition and breaking up existing 100 mm bore salt-glazed stoneware/AC/reinforced cement concrete drain pipes set in cement mortar, including PCC haunching and bedding, getting out and disposal of unserviceable material, complete all as specified and directed. |
| 33 | All as per preceding item but for existing drain pipe of 150 mm bore, complete all as specified and directed. |
| 34 | All as per preceding item but for existing drain pipe of 300 mm bore, complete all as specified and directed. |
| 35 | S&F salt-glazed stoneware drain pipe, 100 mm bore, Grade 'A', ISI marked, laid to required line and gradient in trenches, jointed in cement mortar 1:1 and tested, complete all as specified and directed. |
| 36 | All as per preceding item but for salt-glazed stoneware drain pipe of 150 mm bore, complete all as specified and directed. |
| 37 | M&L for 150 mm bore reinforced cement concrete pipe, Class NP2, laid to required line and gradient and jointed in cement mortar 1:1 complete with collars, including demolition and breaking up of existing pipe and disposal of debris, complete all as specified and directed. |
| 38 | M&L for 300 mm bore reinforced cement concrete pipe, Class NP2, laid to required line and gradient and jointed in cement mortar 1:1 complete with collars, complete all as specified and directed. |
| 39 | M&L for PCC 1:4:8 Type D-2 using 40 mm graded crushed stone aggregate as bedding to 100 mm bore drain pipes, including packing under and haunching against sides of pipes after laying and testing, complete all as specified and directed. |
| 40 | All as per preceding PCC bedding and haunching item but for 150 mm bore drain pipe, complete all as specified and directed. |
| 41 | All as per preceding PCC bedding and haunching item but for 300 mm bore drain pipe, complete all as specified and directed. |
| 42 | M&L for cement concrete 1:2:4 Type B-1 using 20 mm graded crushed stone aggregate as in surface channels, drains and benching, finished fair and smooth to required line, level and gradient, complete all as specified and directed. |
| 43 | M&L extra over cement concrete for forming fair-finished drain/channel of 300 mm inner girth, including necessary formwork, moulds, mitred/stopped ends and finishing, complete all as specified and directed. |
| 44 | M&L for cutting into existing manhole/septic tank for connecting new drain, including cutting out existing benching, forming branch channel half-round/three-quarter section in PCC 1:2:4 Type B-1, smooth finishing, reforming benching, making good around pipe and rendering disturbed surfaces for 100 mm bore pipe, complete all as specified and directed. |
| 45 | All as per preceding item but for 150 mm bore pipe, complete all as specified and directed. |
| 46 | All as per preceding item but for 200 mm to 300 mm bore pipe, complete all as specified and directed. |
| 47 | M&L for waterproofing treatment to sunken floors comprising 15 mm thick cement plaster in CM 1:4 mixed with approved waterproofing compound @ 3% by weight of cement to sunken floor and sides up to finished floor level, preparing plastered surfaces and providing minimum 3 mm thick APP polymeric waterproofing membrane weighing n less than 3.0 Kg/Sqm, polyester reinforced, laid over compatible bituminous primer @ 0.40 litre/Sqm, torch applied with minimum 75 mm side laps and 100 mm end laps, including sealing all joints and treatment of sides up to finished floor level, complete in accordance with manufacturer's instructions and all as specified and directed. Waterproofing treatment shall be executed through manufacturer/authorised applicator. Supply of waterproofing compound shall be measured and paid separately. |
| 48 | S&F in replacement 75 mm bore PVC (SWR), ISI marked, single-socketed pipe in any length with rubber-ring/solvent-cement joints, laid in trenches or floors, including dismantling and taking out existing old U/S 75 mm bore PVC pipe and fittings, jointing, testing and making good, complete all as specified and directed. |
| 49 | S&F in replacement 110 mm bore PVC (SWR), ISI marked, single-socketed pipe in any length with rubber-ring/solvent-cement joints, laid in trenches or floors, including dismantling and taking out existing old U/S 110 mm bore PVC pipe and fittings, jointing, testing and making good, complete all as specified and directed. |
| 50 | S&F in replacement 75 mm bore PVC (SWR), ISI marked, single-socketed pipe in any length with rubber-ring joints, fixed to walls, including demolition/breaking up and taking down existing old U/S 75 mm bore PVC pipe and fittings, complete all as specified and directed. |
| 51 | S&F in replacement 110 mm bore PVC (SWR), ISI marked, single-socketed pipe in any length with rubber-ring joints, fixed to walls, including demolition/breaking up and taking down existing old U/S 110 mm bore PVC pipe and fittings, complete all as specified and directed. |
| 52 | S&F pipe-support clamping system for single 75 mm dia down-take CI/PVC pipe comprising 75 mm wall-distance profile brackets fabricated from 32 x 3 mm low-carbon HRGC steel conforming to IS 1079 DD, continuous slotted C-channel with ribs, 3 mm thick and 250 mm long, and 7 mm dia U-bolt with noise-absorbing ribbed silicone-rubber sleeve, including SS304 serrated flange bolts/nuts, zinc-coated fixing fasteners and all accessories; steel components hot-dip galvanised and Zn-Al flake coated, hot-dip galvanising conforming to IS 2629, fixed at every one metre interval in duct as per CE Jaipur Zone Drawing No. TD/2022/102, complete all as specified and directed. Make: Shaivi or equivalent as approved by GE. |
| 53 | S&F pipe-support clamping system for single 110 mm dia down-take CI/PVC pipe comprising 75 mm wall-distance profile brackets fabricated from 32 x 3 mm low-carbon HRGC steel conforming to IS 1079 DD, continuous slotted C-channel with ribs, 3 mm thick and 250 mm long, and suitable U-bolt for 110 mm dia pipe with noise-absorbing ribbed silicone-rubber sleeve, including SS304 serrated flange bolts/nuts, zinc-coated fixing fasteners and all accessories; steel components hot-dip galvanised and Zn-Al flake coated, hot-dip galvanising conforming to IS 2629, fixed at every one metre interval in duct as per CE Jaipur Zone Drawing No. TD/2022/102, complete all as specified and directed. Make: Shaivi or equivalent as approved by GE. |
| 54 | S&F in replacement PVC (SWR), ISI marked floor trap having 75 mm dia outlet, complete with PTMT grating and solvent-cement jointing, including taking out existing old U/S floor trap and making good disturbed surfaces, complete all as specified and directed. |
| 55 | S&F 75 mm bore PVC (SWR), ISI marked bend of any required radius, complete all as specified and directed. |
| 56 | S&F 75 mm bore PVC (SWR), ISI marked bend of any required radius with access door, complete all as specified and directed. |
| 57 | S&F 110 mm bore PVC (SWR), ISI marked bend of any required radius, complete all as specified and directed. |
| 58 | S&F 110 mm bore PVC (SWR), ISI marked bend of any required radius with access door, complete all as specified and directed. |
| 59 | S&F 75 mm bore PVC (SWR), ISI marked single branch piece (single 'Y'), equal or unequal, with access door, complete all as specified and directed. |
| 60 | S&F 110 mm bore PVC (SWR), ISI marked single junction (single 'T'), equal or unequal, with access door, complete all as specified and directed. |
| 61 | S&F 75 mm bore PVC (SWR), ISI marked single junction (single 'T'), equal or unequal, with access door, complete all as specified and directed. |
| 62 | S&F 110 mm bore PVC (SWR), ISI marked vent cowl, complete all as specified and directed. |
| 63 | S&F in repairs oval access door suitable for 75 mm bore soil/waste pipe, including removing defective access door and providing/fixing new access door complete all as specified and directed. |
| 64 | S&F in repairs oval access door suitable for 100 mm bore soil/waste pipe, including removing defective access door and providing/fixing new access door complete all as specified and directed. |
| 65 | S&F in repairs stack clamp fabricated from MS flat 50 x 5 mm and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall/roof for 75 mm bore pipe, including preparation of steel surfaces and applying one coat red oxide primer followed by two coats synthetic enamel paint, complete all as specified and directed. |
| 66 | S&F in repairs stack clamp fabricated from MS flat 50 x 5 mm and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall/roof for 100 mm bore pipe, including preparation of steel surfaces and applying one coat red oxide primer followed by two coats synthetic enamel paint, complete all as specified and directed. |
| 67 | M&L extra over cast iron pipe and fittings, 75 mm bore, for providing lead joints in lieu of cement joints, complete all as specified and directed. |
| 68 | M&L extra over cast iron pipe and fittings, 100 mm bore, for providing lead joints in lieu of cement joints, complete all as specified and directed. |
| 69 | S&F 75 mm thick steel fibre reinforced concrete (SFRC) manhole cover with matching iron frame, medium duty, square/rectangular/circular as required, conforming to IS 12592 and specified load-bearing capacity, including setting frame true to line and level and making good, complete all as specified and directed. |
| 70 | M&L for TMT steel reinforcement bars 10 mm dia and over, cut to required lengths and bent to shape, including hooks, binding with annealed MS wire n less than 0.9 mm dia or securing with clips and welding with minimum 200 mm overlap between new and existing reinforcement wherever required, at any height, complete all as specified and directed. |
| 71 | S&F TMT steel reinforcement bars 6 mm to 8 mm dia, cut to required lengths and bent to shape, including cranking, spiral bending/hooping for columns, hooks and binding with annealed MS wire n less than 0.9 mm dia, complete all as specified and directed. |
| 72 | M&L for precast cement concrete Type B-1 (1:2:4) using 20 mm graded stone aggregate as in landings, manhole cover slabs, chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face, including chamfers, weatherings and throating and setting in mortar with joints to match, complete all as specified and directed. |
| 73 | S&F in repairs salt-glazed stoneware gully trap, square/round-mouthed 'P' type, size 150 x 150 mm, complete with CI grating, setting and jointing in cement, including PCC 1:3:6 Type C-1 block 300 x 300 x 450 mm around trap, necessary formwork and excavation/earthwork in soft/loose soil, complete all as specified and directed. |
| 74 | M&L for 50 mm thick PCC 1:3:6 Type C-1 using 20 mm graded crushed stone aggregate as in plinth protection, surface finished fair and even to required slope, including forming alternate bays n exc 3 metre long and providing 6 mm wide x 10 mm deep joints along wall and between bays filled with bitumen mastic 1:3, complete all as specified and directed. Plinth protection shall be laid to slope 1:30 and width as directed. |
| 75 | S&F in repairs vitreous china squatting pan, Orissa pattern, white, size 580 x 440 mm with integral foot rests, excluding flushing cistern and flush pipe, including connections to trap, flushing pipe and anti-syphonage pipe and providing PCC 1:7:12 Type F-2 in filling, complete all as specified and directed. |
| 76 | S&F in repairs vitreous china wash-down water closet pan, pedestal pattern EWC, coloured, including connection to drain/outgoing pipe and anti-syphonage pipe, complete with coloured closed-pattern WC seat and cover with flat bottom and CP health faucet/jet, complete all as specified and directed. |
| 77 | S&F in repairs PVC valveless syphonic-action low-level flushing cistern, ISI marked, 10 litre capacity, complete with 32 mm dia PVC flush pipe connected to WC, inlet, ball valve, float, handle and all necessary fittings, complete all as specified and directed. |
| 78 | S&F in repairs single-piece vitreous china wash-down water closet, pedestal pattern EWC, coloured, floor-mounted coupled type, including connection to drain/outgoing pipe and anti-syphonage pipe, coloured closed-pattern WC seat and cover, vitreous china syphonic-action twin-flush cistern of 10 litre capacity with lid and all necessary fittings, complete all as specified and directed. Make: Parryware or equivalent of Hindware/Cera/Johnson/Neycer/Jaquar/Khodiyar/Prayag as approved by GE. |
| 79 | S&F in repairs vitreous china wash hand basin, white, flat-back type, size 550 x 400 mm, including pair of CI brackets embedded in PCC 1:3:6 Type C-1 blocks 100 x 75 x 150 mm, 32 mm dia PVC waste pipe and 32 mm bore CP brass waste fitting with long screwed shank, fly nut and flange, excluding tap, waste chain and plug, complete all as specified and directed. |
| 80 | S&F in repairs vitreous china counter-top wash basin, approximately 450 x 525 x 195 mm, oval shape, including 32 mm CP waste coupling and 900 mm long PVC flexible waste pipe, complete all as specified and directed. Make: Parryware/Jaquar/Somany/Hindware/Prayag or equivalent as approved by GE. |
| 81 | S&F in repairs 15 mm bore concealed-type chromium-plated fancy stop valve of cast copper alloy, high-pressure screw-down pattern with crutch/butterfly handle, long shank and cup, screwed at both ends for iron pipe/unions, complete all as specified and directed. |
| 82 | S&F in repairs 15 mm bore chromium-plated fancy bib tap of cast copper alloy, screw-down type with crutch/butterfly handle, screwed for iron pipe/brass ferrule, complete all as specified and directed. |
| 83 | S&F in repairs 15 mm bore chromium-plated fancy stop valve/angle valve of cast copper alloy, high-pressure screw-down pattern with crutch/butterfly handle, screwed at both ends for iron pipe/union, complete all as specified and directed. |
| 84 | S&F in repairs 15 mm size PVC flexible connection, 600 mm long, complete with PTMT nuts and necessary jointing, complete all as specified and directed. |
| 85 | M&L for taking down or taking up existing 15 mm bore steel tubing and connections, including disconnecting, cleaning and sorting for refixing or removal to store, complete all as specified and directed. |
| 86 | S&F 15 mm bore galvanised iron tube, medium grade, including bends, elbows, sockets, reducers and other necessary fittings, fixed to wall/ceiling or laid in floor, including cutting through walls/floors, jointing and testing, complete all as specified and directed. |
| 87 | M&L for refixing old serviceable 15 mm bore steel tubing and connections in new or existing position on walls, ceilings or floors, including necessary jointing, fixing and testing, complete all as specified and directed. |
| 88 | M&L for cutting chases n exc 100 mm girth, pinning in concealed water tubing and making good disturbed facings, including pointing in cement mortar 1:3, complete all as specified and directed. |
| 89 | M&L for 18–20 mm thick granite slab of approved type, shade and pattern as in platforms, bedded and jointed in grey cement slurry and pointed with white cement mixed with matching pigment, including cutting, grinding and mirror polishing to local trade practice, cutting openings to suit oval wash hand basin and providing 20 mm thick cement mortar 1:6 screed bed, complete all as specified and directed. |
| 90 | M&L for PCC 1:2:4 Type B-0 using 12.5 mm graded crushed stone aggregate as in levelling course to floors, 25 mm thick, surface finished fair and even, complete all as specified and directed. |
| 91 | M&L for coloured non-skid ceramic floor tiles, 7–8 mm thick, square/rectangular, area of each tile exc 0.06 Sqm but n exc 0.11 Sqm, set and jointed in neat cement slurry over 15 mm thick cement mortar 1:6 screed bed and joints pointed with white/coloured cement matching the tile shade, complete all as specified and directed. |
| 92 | M&L for first-quality coloured glazed ceramic tiles, 300 x 450 x 7 mm thick or other approved size, as on vertical surfaces including dado/skirting, set and jointed in neat cement slurry over 10 mm thick cement mortar 1:4 backing and joints pointed with white/coloured cement matching the tile shade, complete all as specified and directed. |
| 93 | M&L for PCC 1:4:8 Type D-2, 75 mm thick, using 40 mm graded stone aggregate as in sub-base, surface finished fair and even, complete all as specified and directed. |
| 94 | M&L for 12 mm thick exterior-grade textured-finish vitrified heavy-duty tiles, area of each tile exc 0.09 Sqm but n exc 0.16 Sqm, suitable for parking/porch areas, set and jointed in neat cement slurry over 20 mm thick cement mortar 1:4 screed bed and joints pointed with white/coloured cement and matching pigment, complete all as specified and directed. Make: Endura Johnson or equivalent as approved by GE. |
| 95 | M&L for chequered coloured cement concrete tiles, 300 x 300 x 25 mm thick, set and jointed in neat cement slurry over 20 mm thick cement mortar 1:4 screed bed and joints pointed with white cement mixed with approved pigment, complete all as specified and directed. |
| 96 | M&L for factory-made, machine-pressed precast cement concrete interlocking paver blocks, 60 mm thick, Grade M-35, conforming to IS 15658:2006, of approved shape and size, manufactured using grey cement and approved pigment, laid over and including 25 mm thick sand cushioning, joints filled with dry sand and compacted with mechanical vibrator, complete all as specified and directed. |
| 97 | M&L for providing and laying at or near ground level factory-made M-25 grade precast cement concrete kerb stones to required line, level and curvature, jointed in cement mortar 1:3, including forming joints with or without grooves, joint thickness n exc 5 mm except at sharp curves, and providing drainage openings wherever required, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysOct 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender