Health and Family Welfare Boards / Undertakings / PSU Closing in 14 days TDR #57699508

Tender For Construction Of Public Health Toilets & Urinals In Ggs Medical College & Hospital Under Bfuhs, Faridkot

Issued by Boards / Undertakings / PSU · Faridkot, Punjab
Tender Value
52.76 Lakhs
Estimated cost
Bid Submission
19 Oct 2026
14 days left
EMD
1.05 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Faridkot → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Public Health Toilets & Urinals In Ggs Medical College & Hospital Under Bfuhs, Faridkot

BOQ

Name of Work:- Construction of Public Health Toilets & Urinals in GGS Medical College & Hospital under BFUHS, Faridkot
Sl. No. Item Description
1Earthwork in excavation in foundations trenches etc in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in15cm ,layers with compaction including disposal of all surplus soil as directed with in lead of 30 metres
2Provding of PCC of 1:5:10 with 40 mm gauge stone blast using concrete mixing volumetric type
3Shutring for faces of concrete foundations and beams and plinth beams
4First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
5Damp proof course 7.5 Cm thick cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetrationat 1.65 Kg per sqm laid hot and sanded
6First class burnt brickwork laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level
7115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure
8Centering and shuttering for sides and soffits of beam, beams , launching girders, bressumers, lintels.
9Centering and shuttering for flat surfaces such as suspended floors roofs landing chajjas shelves etc
10Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe500 grade as per IS1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
11Reinforced cement concrete M-25 mechanically batch mixed using batch type concretemixer asper IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
1210mm thick Cement Plaster 1:4
1312.50mm thick plaster 1:4
14Providing and fixing1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish lighter/emboss conforming to IS 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottlegreen, black ofsize 450x310mm as approved by Engineer-in Charge in skirting, risers of steps and dados over 12mm thick bed of cement Mortar1:4 (1cement:4 fines and) and jointing with grey cement slurry @3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete
15Tile taracing on roof complete
16Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
17Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using echanical mixer for mixing of material
18Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer formixing of material
19Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete . ( Design is homogenous throughout the tile body ).
20Preparationof plasteredor concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying twoormore coats to get required finish
21Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
22Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
23Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16
24Bottom Khurra on ground 1.2m x 0.6m consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3
25Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 2.5 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item)
26Wrought iron & Mild steel ladders, framed grills,gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
27Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered ,concrete surface to give an even shade.
28Public Health WorkCutting chase in brickwalls incement or in floor forembeddingG.I.orC.Ipipes lineand making good the same to its original condition. B Size 150 mm x 150 mm
29CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in Charge), having thermalstability for hot & cold water supply, including all CPVC plain&brass threaded fittings i/c fixing thepipewithclamps at 1.00mspacing including jointing of pipes & fittings,with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
30INTERNAL- EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC )pipes as per IS 15778 (IS marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointingof pipes&fittingswithonestep PVCsolvent cement andtestingofpipes completeasperdirectionofEngineer-in Charge (c) SDR11CPVCpipes&fittings25mm o/d
31Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
32Providing and fixing jet spray with 2'-6\\" long PVC pipe.a) With C.P. Brass nut
33Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brasswaste 32mmdia withoneC.P.brasspillar tapincludingRack Bolt Screw Pair 115mm long complete in all respect.(ii) Size 550 mm x 400 mm x 815 mm
34Providing & Fixing in positionC .P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge) complete in all respect.
35Providing & Fixing in position C.P. Brass extension piece 25mm long to100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respectii C.P.Brassextensionpiece75mm long
36Providing & Fixing in postion15mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.(ii) C.P. brass Bib cock foam flow without flange
37Providing&Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge) complete in all respect.C.P.brass15mmConcealed stop cock with flange.
38C.P.brass 15mm Angle valve without flange
39Providing&Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect
40Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge) complete in all respect. PVC tube connectionof size15 mm x 450 mm with C.P. Brass nut
41Providing and fixing inposition towel rails/ ring of approved make (to the approval of Engineer-in-charge) fixedin with rawl plugs embedded in walls with brass screws complete in all respect b C.P brass towel ring
42Providing and fixing inpositionC.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugsandC.Pbrassscrews complete in all respect
43Providing & Fixing in position 5mm thick bevelled edgemirror of superior glass (of approvedmake) completewith 4mm thick hardboardbacking fixed inwithrawl plugs 50mm, C.P. bras sscrews and washers and S/SStudsontop completeinall respect (as required by the Engineer-in- Charge) b Size 550mmx400mm
44Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects.
45Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
46Providing &placing in positionon terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but withoutfittings and base support for tank.
47Providing and fixing in position G.I. Tank Nippleof approvedmake (to theapproval of Engineer-in-charge) in PVCWater storage tanks complete in all respect.(c) G.I. tank nipple 25mm i/d
48Providing and fixing in position automatic brass Ball Cock in tanks. B Brass Ball Cock with rod and Plastic Ball Iii 25mm i/d
49Providing, fixing and jointing ISI Marked Gun Metal peet valves (HeavyPattern)asper IS 778 with hand wheels , on G.I. Pipe lines laid in the groundor inside buildings including all carriages complete. C 25mmi/dGunMetalpeetvalveheavy pattern.
50Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating150mmx 150mm, cover and frame clear opening 300mmx 300mmandout of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
51Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete1:2:4benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C.inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3coats of black bitum as ticpaint conforming to I.S.I complete as per standard design.
52Excavation manually in trenches with straight or open cutting in built up street/ lane having wall to wall width of street/ lane upto 3.0 metre, for intramural sullage drains, extramural intercepting drains and outfall drains, storm water channels and other work contingent or incident thereto, to full dimensions and depth as shown on the drawings or as shall be required by Engineer in-charge including dressing to correct sections and dimensions according to templates and levels, dewatering of rain water, diversion of traffic. Providing and fixing and maintenance of caution boards, fencing, night signals, for leads upto 15m and for all lifts and subsequent refilling, watering and dressing upto groung level, including removal of surplus spoil from the site upto 15 metre distance complete in all respects.
53Making connection of newly laid sewer in walls of existing manhole of fully charge sewer including cost of pluging sewer, desilting, removal of sullage water and making good of khudda
54Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval of Engineer-in-charge )including cutting, jointing, wastage, but excluding cost of lead jointing. 110mm o/d SWR UPVC pipe line laid complete
5590mm o/d SWR UPVC pipe lines laidcomplete
56160mm o/d SWR UPVC pipe lines laiD complete
57Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonage pipes as per as per IS - 14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.For 110mm o/d pipesSingle Tee
58Elbow 90 Degree (All side socketed)
59P Trap/Floor Trap 110mm x 110mm
60Y-Junction Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57699508
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 52.76 Lakhs
LAST DATE 19-10-2026
Authority
Authority Name Baba Farid University Of Helath Sciences
Work Description Tender for Construction Of Public Health Toilets & Urinals In Ggs Medical College & Hospital Under Bfuhs, Faridkot
Basic Detail
Tender No BFUHS/UWD/84/2026
Bidding Type Tender
Location
City Faridkot
State Punjab
Key Dates
Publish Date 25 Sep 2026
Submission Date 19 Oct 2026
Open Date 21 Oct 2026
Finance
Tender Value 52.76 Lakhs
Tender Fee 1180
EMD 1.05 Lakhs
Exemption Not Available
Document List
BOQ_358622.xls
DNITofpublictoilets.pdf
fa3f4cb2-9082-4c1a-9028-5ab33240e6ec.html
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Oct 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_358622.xls

pdf

DNITofpublictoilets.pdf

html

fa3f4cb2-9082-4c1a-9028-5ab33240e6ec.html

pdf

Tendernotice_1 (20).pdf