Public Administrative Department Local Bodies Closing in 6 days TDR #57699171

Tender For Re-Strengthening/Improvement Of Wiring, Lights, Fans And Other Electrical Allied Works At Surgical Store And General Store At Hindu Rao Hospital

Issued by Local Bodies · Delhi, Delhi
Tender Value
9.49 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
6 days left
EMD
20000
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Re-Strengthening/Improvement Of Wiring, Lights, Fans And Other Electrical Allied Works At Surgical Store And General Store At Hindu Rao Hospital

BOQ

Name of Work:- Re-strengthening/Improvement of wiring, lights, fans and other electrical allied works at Surgical store and General store at Hindu Rao Hospital
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (a) Group C
2Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 15/16 amp switch
3b) 3 pin 5/6 amp socket outlet
4c) 6 pin 15/16 amp socket outlet
5Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
6Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. a) 6 Module (200mmX75mm)
7b) 12 Module (200mm X 150mm)
8Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
92 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
104 X 2.5 sq. mm + 2 X2.5 sq. mm earth wire
112 X 4 sq. mm + 1 X 4 sq. mm earth wire
12Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way (4 + 24), Double door
13Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 amps
14Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
15Supply of 18'(450 mm)sweep 1400 rpm heavy duty Exaust Fan complete with ring, blade etc as required. ISI marked.
16Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
17LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following bodymaterial and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating andFixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 36 watt
18Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
19S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V
20Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
21WINDOW AC UNITS Supplying , Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. Inverter Type - 1.5 TR with Inverter 5 Star BEE rating Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57699171
AUTHORITY Local Bodies
TENDER VALUE 9.49 Lakhs
LAST DATE 05-10-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Re-Strengthening/Improvement Of Wiring, Lights, Fans And Other Electrical Allied Works At Surgical Store And General Store At Hindu Rao Hospital
Basic Detail
Tender No 36/MWEEE-I/2026-27/TC
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 25 Sep 2026
Submission Date 05 Oct 2026
Open Date 05 Oct 2026
Finance
Tender Value 9.49 Lakhs
Tender Fee 590
EMD 20000
Exemption Not Available
Document List
0b91b12b-1685-4309-95c6-f322b6a622ab.html
BOQ_340724.xls
DNIT03.pdf
Tendernotice_1.pdf
Tendernotice_2 (2).pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

0b91b12b-1685-4309-95c6-f322b6a622ab.html

xls

BOQ_340724.xls

pdf

DNIT03.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (2).pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders