Tender For Supply, Installation, Testing And Commissioning For Creation Of 2X1mva Substation And Laying Of Dedicated 11Kv Feeder From Lungmar Substation For Pm E- Bus Sewa At New Bus Stand On Full Turnkey Basis For The Financial Year 2026-27

Issued by Government Departments · Leh, Ladakh
Tender Value
5000
Estimated cost
Bid Submission
16 Oct 2026
9 days left
EMD
7.48 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Leh → Ladakh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply, Installation, Testing And Commissioning For Creation Of 2X1mva Substation And Laying Of Dedicated 11Kv Feeder From Lungmar Substation For Pm E- Bus Sewa At New Bus Stand On Full Turnkey Basis For The Financial Year 2026-27

BOQ

Name of Work:- Supply, Installation, Testing and Commissioning for Creation of 2x1MVA Substation and Laying of Dedicated 11KV feeder from Lungmar Substation for PM e- Bus Sewa at New Bus Stand on full turnkey basis for the Financial Year 2026-27
Sl. No. Item Description
1Supply of Substation Part.
22x1MVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
3Gapless Surge Arrestor, 9 kV,10 kA ,LA with polymer housing, Stn. Type
411kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
511 kV Horn Gap Fuse Set 3 Phase 200A
611KV Single core 120 sqmm Al Conductor wounder wire GI armoured XLPE FRLS
79 Mtr. Long Pole, (ST-410 SP33)
833kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
9GI Channel/Angle/Flat of sizes including clamps
10Galvinized Nuts and Bolts.
11Chemical earthing complete with all clamps, nuts & bolts, washers etc. to be used for to achieve the recommended earth resistance value for high resistivity locations.
1233kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
13Wedge Connectors / PG Clamps
14Danger Plates with Clamps
15GI Barbed Wire for Anti Climbing
16Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
17Painting of Poles Red Oxide
18Painting of Poles Aluminium Paint
19Sundry items like aluminium lugs, Jumpers, binding Tape,
20RCC Transformer Bed for compact 1MVA substation as per approved drawing of CSS
21Transformer fencing with GI
2211KV indoor type Touch proof cable kit
2311KV outdoor type Touch proof cable kit
24GI Flat 50x6mm for Earthing
25HT Smart/Conventional meter with CT PT operated complete with cables earthing with two compartment cubicial box for CT PT and meter including cable and cable kits of required size. CT Ratio (200/5) Meter CTR: -/5A, PTR 11/110V, 0.5S
2611KV RMU 3 way 630A (make ABB, SIEMENS) all VCB 1 Incoming and 2 Outgoing with auto changer (PLC + FRTU) and Aux PT, Multifunction Meter for Inncomer and Outgoing. Commissioning and supervision should be from OEM side.
27RMU Foundation as per approved drawing of OEM
28Installation /Commission/Testing
292x1MVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
30Gapless Surge Arrestor, 9 kV,10 kA ,LA with polymer housing, Stn. Type
3111kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
3211 kV Horn Gap Fuse Set 3 Phase 200A
3311KV Single core 120 sqmm Al Conductor wounder wire GI armoured XLPE FRLS
349 Mtr. Long Pole, (ST-410 SP33)
3533kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
36GI Channel/Angle/Flat of sizes including clamps
37Galvinized Nuts and Bolts.
38Chemical earthing complete with all clamps, nuts & bolts, washers etc. to be used for to achieve the recommended earth resistance value for high resistivity locations.
3933kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
40Wedge Connectors / PG Clamps
41Danger Plates with Clamps
42GI Barbed Wire for Anti Climbing
43Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
44Painting of Poles Red Oxide
45Painting of Poles Aluminium Paint
46Sundry items like aluminium lugs, Jumpers, binding Tape,
47RCC Transformer Bed for compact 1MVA substation as per approved drawing of CSS
48Transformer fencing with GI
4911KV indoor type Touch proof cable kit
5011KV outdoor type Touch proof cable kit
51GI Flat 50x6mm for Earthing
52HT Smart/Conventional meter with CT PT operated complete with cables earthing with two compartment cubicial box for CT PT and meter including cable and cable kits of required size. CT Ratio (200/5) Meter CTR: -/5A, PTR 11/110V, 0.5S
5311KV RMU 3 way 630A (make ABB, SIEMENS) all VCB 1 Incoming and 2 Outgoing with auto changer (PLC + FRTU) and Aux PT, Multifunction Meter for Inncomer and Outgoing. Commissioning and supervision should be from OEM side.
54RMU Foundation as per approved drawing of OEM
55Supply of HT Line Part.
569 Mtr. Long Pole,ST-410 SP33)
5711 Mtr. Long Pole,ST-410 SP56)
58GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
59GI Channel X-arm 1600mm long including clamps and braces (75X40X6mm GI Channel of 1600mm long=40 No.(weight per channel=11.42Kg,back clamp for cantiliver 50X8mm, 365mm long =1.15Kg Total weight=12.57Kg/channel +clamp GI angle 65XiX6mm, 1760mm long =40 nos (weight=10.21Kg, Guy clamp for cantiliver 50X8mm,300mm long=.9Kg, Total weight=11.11Kg Total weight of X-arm and cantiliver=23.68Kg
60GI Channel X-arm including Clamps and Braces for DP (80Kg/DP)
6150 mm² ACSR Conductor
6233kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
6333kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
64Galvinized Nuts and Bolts
65Danger Plates with Clamps
66Anti-Climbing Device with Clamps
67Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
68Red Oxide
69Aluminium Paint
70Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
71Link Set Complete AB Switch
7211KV ACSR Conductor 0.05 Silicon Cover
73Dismentling of ST Poles ACSR Cable Meter SMDB Boxes
74Installation /Commission/Testing
759 Mtr. Long Pole,ST-410 SP33)
7611 Mtr. Long Pole,ST-410 SP56)
77GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
78GI Channel X-arm 1600mm long including clamps and braces (75X40X6mm GI Channel of 1600mm long=40 No.(weight per channel=11.42Kg,back clamp for cantiliver 50X8mm, 365mm long =1.15Kg Total weight=12.57Kg/channel +clamp GI angle 65XiX6mm, 1760mm long =40 nos (weight=10.21Kg, Guy clamp for cantiliver 50X8mm,300mm long=.9Kg, Total weight=11.11Kg Total weight of X-arm and cantiliver=23.68Kg
79GI Channel X-arm including Clamps and Braces for DP (80Kg/DP)
8050 mm² ACSR Conductor
8133kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
8233kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
83Galvinized Nuts and Bolts
84Danger Plates with Clamps
85Anti-Climbing Device with Clamps
86Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
87Red Oxide
88Aluminium Paint
89Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
90Link Set Complete AB Switch
9111KV ACSR Conductor 0.05 Silicon Cover
92Supply of Part.
93LT Panel of 415V, 3-phase ,4wire, 50Hz 35KA/1sec LT feeder pillars comprising of FRP enclosure with combination of incoming and out going feeder, the LT feeder pillar shall be for outdoor installation and shall have IPGS protection class, the lT feeder panel shall be supplied in line with the technical specification as per the following types 2No , Incomer ACB 2000A and outgoing 8Nos MCCBs of 630Ampere and 1Bus Coupler LT panel must be comprised with VMC relay Auto Changeover for DG supply indication lamps voltmeter, ammeter etc.
943.5C X95Sqmm Al conductor XLPE (E) armoured cable
95Termination with DC Glands along with Lux of 3.5C x 630sqmm.
96Chemical earthing complete with all clamps,nuts & bolts, Washer etc. to be used for to achieve the recommeded earth resistance value for high resistivity locations.
97GI Flat 25x6mm for Earthing of service pillar.
98RCC Foundation for Main LT feeder Pillar
99160mm HDPE DWC pipe
100Installation /Commission/Testing
101LT Panel of 415V, 3-phase ,4wire, 50Hz 35KA/1sec LT feeder pillars comprising of FRP enclosure with combination of incoming and out going feeder, the LT feeder pillar shall be for outdoor installation and shall have IPGS protection class, the lT feeder panel shall be supplied in line with the technical specification as per the following types 2No , Incomer ACB 2000A and outgoing 8Nos MCCBs of 630Ampere and 1Bus Coupler LT panel must be comprised with VMC relay Auto Changeover for DG supply indication lamps voltmeter, ammeter etc.
1023.5C X95Sqmm Al conductor XLPE (E) armoured cable
103Termination with DC Glands along with Lux of 3.5C x 630sqmm.
104Chemical earthing complete with all clamps,nuts & bolts, Washer etc. to be used for to achieve the recommeded earth resistance value for high resistivity locations.
105GI Flat 25x6mm for Earthing of service pillar.
106RCC Foundation for Main LT feeder Pillar
107160mm HDPE DWC pipe
108Dismentling Part
109Dismentling of ST Poles ACSR Cable Meter SMDB Boxes Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57696169
AUTHORITY Government Departments
TENDER VALUE 5000
LAST DATE 16-10-2026
Authority
Authority Name Power Development Department
Work Description Tender for Supply, Installation, Testing And Commissioning For Creation Of 2X1mva Substation And Laying Of Dedicated 11Kv Feeder From Lungmar Substation For Pm E- Bus Sewa At New Bus Stand On Full Turnkey Basis For The Financial Year 2026-27
Basic Detail
Tender No e-NIT No. 29 of ED Leh of 2026-27 dated 24-09-2026
Bidding Type Tender
Location
City Leh
State Ladakh
Key Dates
Publish Date 24 Sep 2026
Submission Date 16 Oct 2026
Open Date 17 Oct 2026
Finance
Tender Value 5000
Tender Fee 5000
EMD 7.48 Lakhs
Exemption Not Available
Document List
1c6de833-0e41-495d-ad16-8ea8d14206fe.html
BOQ_46385.xls
Tendernotice_1 (34).pdf
Tendernotice_2 (4).pdf
Tendernotice_3 (1).pdf
Tendernotice_4.pdf
Tendernotice_5 (1).pdf
Tendernotice_6.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Oct 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

1c6de833-0e41-495d-ad16-8ea8d14206fe.html

xls

BOQ_46385.xls

pdf

Tendernotice_1 (34).pdf

pdf

Tendernotice_2 (4).pdf

pdf

Tendernotice_3 (1).pdf

pdf

Tendernotice_4.pdf

pdf

Tendernotice_5 (1).pdf

pdf

Tendernotice_6.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders