Tender For Supply, Installation, Testing And Commissioning For Creation Of 2X1mva Substation And Laying Of Dedicated 11Kv Feeder From Lungmar Substation For Pm E- Bus Sewa At New Bus Stand On Full Turnkey Basis For The Financial Year 2026-27
Tender Overview
Project Description
Tender for Supply, Installation, Testing And Commissioning For Creation Of 2X1mva Substation And Laying Of Dedicated 11Kv Feeder From Lungmar Substation For Pm E- Bus Sewa At New Bus Stand On Full Turnkey Basis For The Financial Year 2026-27
BOQ
| Sl. No. | Item Description |
| 1 | Supply of Substation Part. |
| 2 | 2x1MVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate |
| 3 | Gapless Surge Arrestor, 9 kV,10 kA ,LA with polymer housing, Stn. Type |
| 4 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 5 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 6 | 11KV Single core 120 sqmm Al Conductor wounder wire GI armoured XLPE FRLS |
| 7 | 9 Mtr. Long Pole, (ST-410 SP33) |
| 8 | 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 9 | GI Channel/Angle/Flat of sizes including clamps |
| 10 | Galvinized Nuts and Bolts. |
| 11 | Chemical earthing complete with all clamps, nuts & bolts, washers etc. to be used for to achieve the recommended earth resistance value for high resistivity locations. |
| 12 | 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 13 | Wedge Connectors / PG Clamps |
| 14 | Danger Plates with Clamps |
| 15 | GI Barbed Wire for Anti Climbing |
| 16 | Cement bottoming 1:2:4 mix as per REC standards .5cum/pole |
| 17 | Painting of Poles Red Oxide |
| 18 | Painting of Poles Aluminium Paint |
| 19 | Sundry items like aluminium lugs, Jumpers, binding Tape, |
| 20 | RCC Transformer Bed for compact 1MVA substation as per approved drawing of CSS |
| 21 | Transformer fencing with GI |
| 22 | 11KV indoor type Touch proof cable kit |
| 23 | 11KV outdoor type Touch proof cable kit |
| 24 | GI Flat 50x6mm for Earthing |
| 25 | HT Smart/Conventional meter with CT PT operated complete with cables earthing with two compartment cubicial box for CT PT and meter including cable and cable kits of required size. CT Ratio (200/5) Meter CTR: -/5A, PTR 11/110V, 0.5S |
| 26 | 11KV RMU 3 way 630A (make ABB, SIEMENS) all VCB 1 Incoming and 2 Outgoing with auto changer (PLC + FRTU) and Aux PT, Multifunction Meter for Inncomer and Outgoing. Commissioning and supervision should be from OEM side. |
| 27 | RMU Foundation as per approved drawing of OEM |
| 28 | Installation /Commission/Testing |
| 29 | 2x1MVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate |
| 30 | Gapless Surge Arrestor, 9 kV,10 kA ,LA with polymer housing, Stn. Type |
| 31 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 32 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 33 | 11KV Single core 120 sqmm Al Conductor wounder wire GI armoured XLPE FRLS |
| 34 | 9 Mtr. Long Pole, (ST-410 SP33) |
| 35 | 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 36 | GI Channel/Angle/Flat of sizes including clamps |
| 37 | Galvinized Nuts and Bolts. |
| 38 | Chemical earthing complete with all clamps, nuts & bolts, washers etc. to be used for to achieve the recommended earth resistance value for high resistivity locations. |
| 39 | 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 40 | Wedge Connectors / PG Clamps |
| 41 | Danger Plates with Clamps |
| 42 | GI Barbed Wire for Anti Climbing |
| 43 | Cement bottoming 1:2:4 mix as per REC standards .5cum/pole |
| 44 | Painting of Poles Red Oxide |
| 45 | Painting of Poles Aluminium Paint |
| 46 | Sundry items like aluminium lugs, Jumpers, binding Tape, |
| 47 | RCC Transformer Bed for compact 1MVA substation as per approved drawing of CSS |
| 48 | Transformer fencing with GI |
| 49 | 11KV indoor type Touch proof cable kit |
| 50 | 11KV outdoor type Touch proof cable kit |
| 51 | GI Flat 50x6mm for Earthing |
| 52 | HT Smart/Conventional meter with CT PT operated complete with cables earthing with two compartment cubicial box for CT PT and meter including cable and cable kits of required size. CT Ratio (200/5) Meter CTR: -/5A, PTR 11/110V, 0.5S |
| 53 | 11KV RMU 3 way 630A (make ABB, SIEMENS) all VCB 1 Incoming and 2 Outgoing with auto changer (PLC + FRTU) and Aux PT, Multifunction Meter for Inncomer and Outgoing. Commissioning and supervision should be from OEM side. |
| 54 | RMU Foundation as per approved drawing of OEM |
| 55 | Supply of HT Line Part. |
| 56 | 9 Mtr. Long Pole,ST-410 SP33) |
| 57 | 11 Mtr. Long Pole,ST-410 SP56) |
| 58 | GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set) |
| 59 | GI Channel X-arm 1600mm long including clamps and braces (75X40X6mm GI Channel of 1600mm long=40 No.(weight per channel=11.42Kg,back clamp for cantiliver 50X8mm, 365mm long =1.15Kg Total weight=12.57Kg/channel +clamp GI angle 65XiX6mm, 1760mm long =40 nos (weight=10.21Kg, Guy clamp for cantiliver 50X8mm,300mm long=.9Kg, Total weight=11.11Kg Total weight of X-arm and cantiliver=23.68Kg |
| 60 | GI Channel X-arm including Clamps and Braces for DP (80Kg/DP) |
| 61 | 50 mm² ACSR Conductor |
| 62 | 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 63 | 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 64 | Galvinized Nuts and Bolts |
| 65 | Danger Plates with Clamps |
| 66 | Anti-Climbing Device with Clamps |
| 67 | Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip. |
| 68 | Red Oxide |
| 69 | Aluminium Paint |
| 70 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole |
| 71 | Link Set Complete AB Switch |
| 72 | 11KV ACSR Conductor 0.05 Silicon Cover |
| 73 | Dismentling of ST Poles ACSR Cable Meter SMDB Boxes |
| 74 | Installation /Commission/Testing |
| 75 | 9 Mtr. Long Pole,ST-410 SP33) |
| 76 | 11 Mtr. Long Pole,ST-410 SP56) |
| 77 | GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set) |
| 78 | GI Channel X-arm 1600mm long including clamps and braces (75X40X6mm GI Channel of 1600mm long=40 No.(weight per channel=11.42Kg,back clamp for cantiliver 50X8mm, 365mm long =1.15Kg Total weight=12.57Kg/channel +clamp GI angle 65XiX6mm, 1760mm long =40 nos (weight=10.21Kg, Guy clamp for cantiliver 50X8mm,300mm long=.9Kg, Total weight=11.11Kg Total weight of X-arm and cantiliver=23.68Kg |
| 79 | GI Channel X-arm including Clamps and Braces for DP (80Kg/DP) |
| 80 | 50 mm² ACSR Conductor |
| 81 | 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 82 | 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 83 | Galvinized Nuts and Bolts |
| 84 | Danger Plates with Clamps |
| 85 | Anti-Climbing Device with Clamps |
| 86 | Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip. |
| 87 | Red Oxide |
| 88 | Aluminium Paint |
| 89 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole |
| 90 | Link Set Complete AB Switch |
| 91 | 11KV ACSR Conductor 0.05 Silicon Cover |
| 92 | Supply of Part. |
| 93 | LT Panel of 415V, 3-phase ,4wire, 50Hz 35KA/1sec LT feeder pillars comprising of FRP enclosure with combination of incoming and out going feeder, the LT feeder pillar shall be for outdoor installation and shall have IPGS protection class, the lT feeder panel shall be supplied in line with the technical specification as per the following types 2No , Incomer ACB 2000A and outgoing 8Nos MCCBs of 630Ampere and 1Bus Coupler LT panel must be comprised with VMC relay Auto Changeover for DG supply indication lamps voltmeter, ammeter etc. |
| 94 | 3.5C X95Sqmm Al conductor XLPE (E) armoured cable |
| 95 | Termination with DC Glands along with Lux of 3.5C x 630sqmm. |
| 96 | Chemical earthing complete with all clamps,nuts & bolts, Washer etc. to be used for to achieve the recommeded earth resistance value for high resistivity locations. |
| 97 | GI Flat 25x6mm for Earthing of service pillar. |
| 98 | RCC Foundation for Main LT feeder Pillar |
| 99 | 160mm HDPE DWC pipe |
| 100 | Installation /Commission/Testing |
| 101 | LT Panel of 415V, 3-phase ,4wire, 50Hz 35KA/1sec LT feeder pillars comprising of FRP enclosure with combination of incoming and out going feeder, the LT feeder pillar shall be for outdoor installation and shall have IPGS protection class, the lT feeder panel shall be supplied in line with the technical specification as per the following types 2No , Incomer ACB 2000A and outgoing 8Nos MCCBs of 630Ampere and 1Bus Coupler LT panel must be comprised with VMC relay Auto Changeover for DG supply indication lamps voltmeter, ammeter etc. |
| 102 | 3.5C X95Sqmm Al conductor XLPE (E) armoured cable |
| 103 | Termination with DC Glands along with Lux of 3.5C x 630sqmm. |
| 104 | Chemical earthing complete with all clamps,nuts & bolts, Washer etc. to be used for to achieve the recommeded earth resistance value for high resistivity locations. |
| 105 | GI Flat 25x6mm for Earthing of service pillar. |
| 106 | RCC Foundation for Main LT feeder Pillar |
| 107 | 160mm HDPE DWC pipe |
| 108 | Dismentling Part |
| 109 | Dismentling of ST Poles ACSR Cable Meter SMDB Boxes Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender