Tender For Construction Of Additional Classroom For At High School Igoo Leh.
Tender Value
40.68 Lakhs
Estimated cost
Bid Submission
10 Oct 2026
7 days left
EMD
81360
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Leh → Ladakh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Additional Classroom For At High School Igoo Leh.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) infoundation trenches or drains (not exceeding 1.5m in width or 10sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m. |
| 2 | Filling availableexcavatedearth (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20cm indepth, consolidating eachdeposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 3 | Dumping stone including cost of stones. in Horizontal on level |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 gradedstone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for:Foundation,Plinth Beam, footing bases of column |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls Above 20 cm wide |
| 10 | Random rubble masonry with hard stone in foundation and plinth includinglevelling up with cement concrete 1:6:12 (1 cement :6 coarses and:12 gradedstone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 11 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 12 | Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 13 | Providing and laying in position stabilized rammed earth with 8% cement in walls using mixture of selected earth and clay of gradation as directed by engineer in charge mechanically mixed, placed in position compacted by vibration including form work up to floor one level. |
| 14 | Pebble dash plaster upto 10 m height above ground level with a mixture of washed pebble or crushed stone 6 mm to 12.5 mm nominal size, dashed over and including fresh plaster in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. |
| 15 | CEMENT PLASTER (IN FINE SAND) 12mm Cement plaster of mix:1 : 4 ( 1 cement : 4 fine sand) |
| 16 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 17 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete |
| 18 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 19 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 20 | French spirit polishing, Two or more coats on new works including a coat of wood filler |
| 21 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 22 | Providing wood work in frames of doors, (Double Glazed) windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class kail wood |
| 23 | Providing and fixing ISI marked flush door shutters conformingto IS:2202 (PartI) non-decorative type, core of block board construction with frameof 1st classhard wood and wel lmatched commercial 3ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30mm thick including ISImarked Stainless Steel butt hinges with necessary screws |
| 24 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws,excluding panelling which will be paid for separately, all complete as perdirection of Engineer-in-charge. (Note:-Butt hinges and necessary screws shall be paid separately. Second class kail wood (MD) |
| 25 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class teak wood 30 mm thick |
| 26 | Float glass panes5.0 mm thick glass panes (weight not less than 12.50 kg/sqm) |
| 27 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 28 | Providing and fixing ISI marked oxidized M.S. handles conforming to IS : 4992 with necessary screws etc. complete : a) (75 mm) |
| 29 | b) (125mm) |
| 30 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete. (100mmx10mm) |
| 31 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete. (150mmx10mm) |
| 32 | Providing and fixing bright finished brass door latch with necessary screws etc. complete. : 250x16x5 mm |
| 33 | Providing and fixing of stainless steel 200 mm long aldrop along with necessary crown,screws, labour cost, transportation,profits etc complete in all respects as per direction of Engineer-in-charge |
| 34 | Providing and fixing traditionally carved wood work (Shingstak) over doors and windows including all accessories as per the direction of the Engineer in-charge complete with; Budloo wood |
| 35 | Carriage of material from source to site of work by MT. Including loading, unloading and stacking complete. A) b) Cement an average lead 40 kms |
| 36 | B) Sand an average lead of 25 kms |
| 37 | C) stone aggregate an average lead of 25kms |
| 38 | d) stone an average lead of 20 kms |
| 39 | e) timber an average lead of 40 kms |
| 40 | Wiring for light point / fan point / exhaust fan point / call bell point / FIRE point with 2X1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group-A |
| 41 | Wiring for light / power plug with 2X2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 42 | Wiring for light / power plug with 2X4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 43 | 2X1.5sq.mm + 1X 1.5 sq. mm earth wire |
| 44 | 2 x10 sqmm + 1 x 6 sq mm earth wire |
| 45 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required.5/6A Switch |
| 46 | 3 pin 5/6 A socket outlet |
| 47 | 15/16 A switch |
| 48 | 6 pin 15/16 A socket outlet |
| 49 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate asrequired. |
| 50 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no. 3 pin 5/6 A modular socket outlet and 2 no 5/6 A modular switch, connections etc. as required. |
| 51 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing and fixing 1 no. 3 pin 5/6 A modular socket outlet and 1 no 5/6 A modular switch, connections etc. as required. |
| 52 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 53 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 14 way, Double door SPN MCBDB |
| 54 | Supplying and fixing 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. Above 32 Amp SPN 63 Amp |
| 55 | Supply, installation, testing & commissioning of GI Electrode Earthing with 84mm dia and 3 meter length, with 40mm x 6mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover. |
| 56 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 57 | Supplying & fixing following luminaries as required 10watt LED tube light fitting. Philips OR Equivalent. |
| 58 | 20 watt LED tube light fitting. Model / equivalent make and model Philips. |
| 59 | Sypplying & fixing LED type down lighter 15 watt Philips or equivalent. |
| 60 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm |
| 61 | Supplying and fixing of 1.1 KV PVC insulated and PVC sheathed XLPE Power Cable of following sizes on surface/surface cable tray,0.50 mtr bleow ground level etc. as required including carriage upto site of work. (Make as per annexure enclosed)25sqmm twin Core-Armoured |
| 62 | Supplying and fixing of 120 watt LED Street Light complete with GI pipe bracket duly embeded along the paraper/ wall Wipro LRO2-132-XXX-57-G2 or equivalent approved make. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender