Tender For Improvements By Providing Air Conditioning Arrangements And Renewal Of Ei, Led Sbt Fittings And Fans At Athletics Weight Training Hall At Aringar Anna Stadium C Us At Nagercoil In Kanniyakumari District.
Tender Value
4.79 Lakhs
Estimated cost
Bid Submission
08 Oct 2026
4 days left
EMD
4800
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kanniyakumari → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Improvements By Providing Air Conditioning Arrangements And Renewal Of Ei, Led Sbt Fittings And Fans At Athletics Weight Training Hall At Aringar Anna Stadium C Us At Nagercoil In Kanniyakumari District.
BOQ
| Sl. No. | Item Description |
| 1 | Rewiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module GI switch box on wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire with painting of Suitable colour for Open PVC Light point/ fan point (for electronic regulator) (5 points/Coil) Higher End |
| 2 | Rewiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module GI switch box on wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire with painting of Suitable colour for Open PVC Light point/ fan point (for electronic regulator) (6 points/Coil) Higher End |
| 3 | Renewal by Supply and fixing of 4 Feet LED 20 W Fitting with LED 20 W tube (Higher End) complete with TWround blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. |
| 4 | Renewal by Supply and fixing of 1200mm (48\\") AC ceiling fan complete with stepped electronic 300W regulator with 1 meter down rod on the existing clamp |
| 5 | Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. |
| 6 | Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigd pipe on wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire with painting of suitable colour. |
| 7 | Supply and run of 4 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour. |
| 8 | Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour. |
| 9 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End |
| 10 | Supply and fixing of 32 Amps FP MCB with sheet steel enclosure (Higher end) in flush with wall and making good of the concealed portion with earth connection (The FP MCB & Enclosure should be of ( Higher end). |
| 11 | Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB as incoming and 2 nos 32A Triple Pole MCB and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End |
| 12 | Supply, Installation, testing and commissioning of 3.0 TR cassette type airconditioning unit with indoor unit comprising of cooling coil, evaporator fan and motor controls, insulated drain pan enclosed in cabinet and 3TR outdoor unit complete with compressor, condenser fan and motor and enclosed in powder coated sheet metal cabinet Unit shall be suitable for operation on 415 +/- 10% Volts,50 HZ, AC Supply, units shall be supplied with microprocessor control including following accessories;1. filling of R-410A Refrigerant gas.2. Six core 1.5 sqmm control cable from indoor to outdoor unit Carrier/Bluestar/eq. make |
| 13 | Supply, fabrication and fixing of MS Channel for mounting the Airconditioning Outdoor Unit |
| 14 | Supply and laying of 5/8\\" and 3/8\\" copper pipe (Extra beyond 3 metres supplied with AC unit) |
| 15 | Supply and fixing of water drain pipe Line. |
| 16 | Supply and run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall/floor/ground for earth connection. |
| 17 | Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. |
| 18 | GST Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysOct 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender