Housing Urban and Rular Development Local Bodies Closing in 1 days TDR #57694535

Tender For maintenance of Completed Scheme Under Na-Ii (Horticulture Zone).Sub-Head:- Supplying And Replacement Of Light Control Feeder Panel, Pump Panel & Meter Panel At Various Parks Of Hd-8.

Issued by Local Bodies · Delhi, Delhi
Tender Value
28.14 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
1 days left
EMD
56299
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for maintenance of Completed Scheme Under Na-Ii (Horticulture Zone).Sub-Head:- Supplying And Replacement Of Light Control Feeder Panel, Pump Panel & Meter Panel At Various Parks Of Hd-8.

BOQ

Name of Work:- M/o Completed Scheme under NA-II (Horticulture Zone).Sub-Head:- Supplying and Replacement of Light Control Feeder Panel, Pump Panel & Meter Panel at various Parks of HD-8.
Sl. No. Item Description
1Supplying and Replacement of Floor Mounted (Light Panel) LT Feeder Pillar Cubical type Double Door of size 1000 mm x 900 mm x 300 mm deep duly compartmentalized and with general arrangement made out of 2 mm thick CRCA Sheet having hinged gasket cover and screwed knobs with double locking arrangement and rain protection covers 100 mm and supported with MS Angle Iron legs and bottom frame of size 35 mm x 35 mm x 5 mm x 1 mtr. long grouted with 1:3:6 CC Foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering including supply and fixing of following accessories complete etc. as required (as per drawing approved by Engineer-in-Charge) including rebate for dismantle material.a) 100 A, 30 kA, 4 Pole MCCB (‘C’-Series)- 1 No.b) 6 A to 32 A ratings, SP MCB, “C” curve, 10 KA breaking capacity- 6 Nos.c) 6 A to 32 A ratings, DP MCB, “C” curve, 10 KA breaking capacity- 1 No.d) Analogue Timer Switch for daily operation and Toggle Switch for Auto/Manual- 1 No.e) 3-Pole Power Contactor of AC3 Rating 32 Amp- 1 No.f) 30 Amp, 4-Way Neutral Link/Connector- 2 Nos.g) Voltmeter (0-500 V) 96 mm x 96 mm Square type with Selector Switch- 1 No.h) Ammeter (0-30 A) 96 mm x 96 mm Square type- 1 No.i) Phase Indication Lamp (RYB) with Fuses- 1 Set.j) Danger Notice Plate- 1 No.k) 100 A, 4-Strip Al. Bus-Bar of minimum 300 mm long with sleeve and nut-bolts- 1 Set.l) Lifting Hook on the Top of Panel Board and Lighting arrangement inside the Feeder Pillar- 1 No.
2Supplying and Replacement of Floor mounted LT Feeder Pillar Cubical type of size 1000 (H) mm x 900 mm (W) x 400 mm (D) (for Meter Installaion) made out of 2 mm thick MS CRCA Sheet having hinged gasket covers and screwed knobs with locking arrangement & Locking Hooks and separate Rain Protection Cover with extension of 100 mm, supported with MS Angle Iron legs and bottom frame of size 35 mm x 35 mm x 5 mm x 1 mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, Painting with Primer, Numbering including Supply & Fixing of following accessories etc. complete as required (as per drawing approved by Engineer-in-Charge) including rebate for dismantle Feeder Pillar.a) Bakelite Sheet of suitable size for Meter Installation.b) Lifting Hook on the top of Feeder Pillar- 1 Set. c) Bus-Bard) 125 A, 36 kA, 4 Pole MCCB (‘C’-Series)- 1 No.
3Supplying, Fabrication and Replacement of Wire Mesh Protection Frame for Existing Feeder Pillar, constructed from 8 SWG MS wire mesh with a Nominal size of 75 mm x 25 mm Rectangle. The Frame dimensions are 1.5 mtr. (Width) x 1.00 mtr. (Depth) x 2.00 mtr. (Height). It includes a Base Frame made of 40 mm x 40 mm x 6 mm MS Angle Iron, MS Strip Supports of 40 mm x 6 mm, and 0.5-meter-long leg supports of the same Angle Iron, all as per the approved drawing. Additionally, provide a suitably sized door, Supply and Fix a godown lock with locking arrangement, painting, and grouting with 1:2:4 Cement Concrete Foundation, as approved by the Engineer-in-Charge, complete as required including rebate for dismantle material.
4Supplying of following sizes of XLPE (Cross Linked Poly Ethylene) Insulated PVC Sheathed Alumimium Conductor Armoured Power Cable of 1.1 KV grade including connection, testing etc. as required including rebate for dismantle material.2C x 16 sq. mm
54C x 25 sq. mm
6Laying of one number PVC Insulated and PVC Sheathed/XLPE Power Cable of 1.1 KV grade of following size in the Existing RCC/HUME/METAL Pipe as required.Up to 35 sq. mm
7Providing and Fixing 25 mm x 5 mm GI Strip on surface or in recess for connection etc. as required.
8Supplying and Replacement of Floor mounted LT Feeder Pillar (Pump Panel) Cubical type Double Door of size 1000 (H) mm x 900 mm (W) x 300 mm (D) deep with general arrangement made out of 2 mm thick MS CRCA Sheet having hinged gasket covers and screwed knobs with double locking arrangement & Locking Hooks and separate Rain Protection Cover with extension of 100 mm in Width & Depth, supported with MS Angle Iron legs and bottom frame of size 35 mm x 35 mm x 5 mm x 1 mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, Painting with Primer, Numbering, Identification Plate of Component embossed and/or printed in Metal including Supply & Fixing of following accessories etc. complete as required (as per drawing approved by Engineer-in-Charge) including rebate for dismantle Panel.a) 100 A, 30 kA, 4 Pole MCCB (‘C’-Series)- 1 No.b) 7.5 Hp, 3-Ph Pump Controller with Single Phase Preventor & C-Curve TP MCB with suitable Relay Range of 13 to 22 Amp- 1 Set.c) 6 A to 32 A ratings, DP MCB, “C” curve, 10 KA breaking capacity- 1 No.d) 6 A to 32 A ratings, TPN MCB, “C” curve, 10 KA breaking capacity- 2 Nos.e) Danger Notice Plate- 1 No.f) Lifting hook on the top of Feeder Pillar- 1 Set. g) 100 A, 4-Strip Al. Bus-Bar of minimum 300 mm long with sleeve and nut-bolts- 1 Set.h) Ammeter (0-30 A) 96 sq. mm in size Square type- 1 No.i) Voltmeter (0-500 V) 96 sq. mm in size Square type with Selector Switch- 1 No.j) Phase Indication Lamp (RYB) with Fuses- 1 Set.
9Supplying and Replacement of Floor mounted LT Feeder Pillar (Pump Panel) Cubical type Double Door of size 1000 (H) mm x 900 mm (W) x 300 mm (D) deep with general arrangement made out of 2 mm thick MS CRCA Sheet having hinged gasket covers and screwed knobs with double locking arrangement & Locking Hooks and separate Rain Protection Cover with extension of 100 mm in Width & Depth, supported with MS Angle Iron legs and bottom frame of size 35 mm x 35 mm x 5 mm x 1 mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, Painting with Primer, Numbering, Identification Plate of Component embossed and/or printed in Metal including Supply & Fixing of following accessories etc. complete as required (as per drawing approved by Engineer-in-Charge) including rebate for dismantle Panel.a) 100 A, 30 kA, 4 Pole MCCB (‘C’-Series)- 1 No.b) 3-Ph DOL Submersible Pump Starter & C-Curve TP MCB with suitable Relay Range of 9 to 14 Amp- 1 Set.c) 6 A to 32 A ratings, DP MCB, “C” curve, 10 KA breaking capacity- 1 No.d) 6 A to 32 A ratings, TPN MCB, “C” curve, 10 KA breaking capacity- 2 Nos.e) Danger Notice Plate- 1 No.f) Lifting hook on the top of Feeder Pillar- 1 Set.g) 100 A, 4-Strip Al. Bus-Bar of minimum 300 mm long with sleeve and nut-bolts- 1 Set.h) Ammeter (0-30 A) 96 sq. mm in size Square type- 1 No.i) Voltmeter (0-500 V) 96 sq. mm in size Square type with Selector Switch- 1 No.j) Phase Indication Lamp (RYB) with Fuses- 1 Set. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57694535
AUTHORITY Local Bodies
TENDER VALUE 28.14 Lakhs
LAST DATE 01-10-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for maintenance of Completed Scheme Under Na-Ii (Horticulture Zone).Sub-Head:- Supplying And Replacement Of Light Control Feeder Panel, Pump Panel & Meter Panel At Various Parks Of Hd-8.
Basic Detail
Tender No 42/EE(E)/ELD-12/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 24 Sep 2026
Submission Date 01 Oct 2026
Open Date 03 Oct 2026
Finance
Tender Value 28.14 Lakhs
Tender Fee Ref. Documents
EMD 56299
Exemption Available
Document List
BOQ_974839.xls
ec4ebac3-f27c-45b8-8d44-281aedd5cea6.html
NIT42.pdf
PressNotice42.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Oct 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_974839.xls

html

ec4ebac3-f27c-45b8-8d44-281aedd5cea6.html

pdf

NIT42.pdf

pdf

PressNotice42.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders