Tender For Minor Repair Of Cac Section, Retrieved Gallery, Strong Room And Confiscated Gallery At Purana Qila, New Delhi
Tender Value
1.31 Crore
Estimated cost
Bid Submission
05 Oct 2026
5 days left
EMD
3.95 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Minor Repair Of Cac Section, Retrieved Gallery, Strong Room And Confiscated Gallery At Purana Qila, New Delhi
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge |
| 2 | Providing and laying brick aggrigate in 25 to 40 mm nominal size before laying the lime/cement concrete for filling and raise the height of floor level as per existing of museum gallery etc complete. |
| 3 | Providing and laying lime concrete bed with 20mm to 25mm thick brick blast mixed with 50% lime mortar in ratio of 1:1:1 (1 U/lime ,1 surkhi ,1 Sand )after compacting of loose soil, including beation and ramming for finishing the top surface and adding adhesive material comlete with in 300m lead etc complete. |
| 4 | Providing and fixing 60 mm thick red sand stone flooring over 20mm thick 1:1:1 lime mortar including cutting , finishing and fine dressing etc complete |
| 5 | Providing 50 to 60MM Thick plain/curved lime plaster in lime Surkhi mortar 1:1:1 (1 lime : 1 surkhi : 1 coarse sand) mixed with adhesive materials such as Gur, Belgiri, Gum & San including carriage of water & materials with in a lead upto 300m & lift upto 6 m appx |
| 6 | \\"Providing and applying 3mm thick lime punning with special lime mortar mix with Lime, Gum, Batasa, Marble Dust, Belgiri etc. over newly plastered surface semi molded on walls nitches, arches, ornamental design similar to original including removing old decayed very carefully and preparing surface for punning etc. complete in all respect.\\" |
| 7 | \\"Providing and fixing 12 mm thick frameless toughened glass in spherical/curved shape of approved brand and manufactured, including providing & fixing, making the holes and fixing the top & bottom with S.S. L patti etc all complete as per direction of Engineer-incharge. \\" |
| 8 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 9 | R R Masonry with lime mortar 1:1:1(1 lime:1 surkhi:1sand) with necessary for proper strenthing the structure in proper manner etc complete. (DQ stones are available at site) |
| 10 | Recessed pointing the R.R. stone masonry in lime surkhi mortar 1:1:1 (1 Lime, 1 Surkhi, B.P. Sand) including racking out the joints, cleaning and washing the joints with adhesive materials such as Gur, Belgiri, Gum including Carriage of Water and Materials within a lead up to 300 M approx. |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.99.1 One or more coats on old work |
| 12 | Polishing on wood work with ready made wax polish of approved brand and manufacture : 13.104.1 Old work |
| 13 | \\"Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.\\" |
| 14 | Supplying,stacking and laying at site.16.3.2 63 mm to 45 mm size stone aggregate including labour charges etc complete. |
| 15 | Providing and laying C.C. pavement of mix M-20 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately).Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. |
| 16 | Coursed rubble masonry pitching with hard stone (top even surface) in above plinth level. Masonry work in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing in proper manner etc complete. |
| 17 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.1 Of area 3 sq. metres and below |
| 18 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.2 Sal wood |
| 19 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 20 | Provision for providing and fixing of xpm wire mass jaali to protect area of Pre historic gallery & Antiquity strong room including all material & labour charges etc complete. |
| 21 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps andM.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item tobe done. |
| 22 | Providing and laying 50 mm dia. PVC conduit pipe for laying/conducting electrical wires, cables and other services for future requirements, including cutting, bending and forming the pipe to the required shape and alignment, providing and fixing suitable grooves/chases, clamps, saddles, holders and other necessary supports at required intervals, and making good the surface after installation, complete in all respects as per site requirements and directions of the Engineer-in-Charge.50 mm dia PVC Pipe (In heavy duty) (Rates are inclusive GST ) |
| 23 | For fixing of pipe on wall with the help of grounting & epoxy material without damaging the structure and length 160 Rmt including socket, PVC box & other fittings required inside the cell fulfill the purpose of electricity requirement in proper manner etc. ( Rates are inclusive with GST ) |
| 24 | \\"Provision for supply and fixing of petty articles as per requirement for CAC etc complete (Details given in Data Analysis).\\"16 Amp 3 pin top ISI marked |
| 25 | 6 Amp 3 pin top ISI marked |
| 26 | 16 Amp power combine with box ISI marked |
| 27 | Water proof tape roll ISI marked |
| 28 | PVC Tape roll ISI marked |
| 29 | Cotton tape ISI marked |
| 30 | TPN Isolator ISI marked 100 amp |
| 31 | 6mm Telephone gitty |
| 32 | DP MCB box ISI marked |
| 33 | 63 Amp DP MCB ISI markedq |
| 34 | 40 Amp DP MCB ISI marked |
| 35 | 32 Amp DP MCB ISI marked |
| 36 | 32 Amp MCB ISI marked |
| 37 | 16 Amp MCB ISI marked |
| 38 | Bottle type thimble Aluminium |
| 39 | 25mm Ring type thimble Aluminium |
| 40 | Ceiling fan 48 (Crompton/Usha or any eqv brand |
| 41 | Exhaust Fan 12\\" Crompton |
| 42 | 6 Amp switch ISI marked |
| 43 | 6 Amp Socket ISI marked |
| 44 | 16 Amp Switch ISI marked |
| 45 | 16 Amp Socket ISI marked |
| 46 | 3.15 MFD Fan Capacitor ISI marked |
| 47 | PVC Gitti 1.5 |
| 48 | Fan regulater ISI marked |
| 49 | 10 Sqmm copper single core wire havells / polycab or equ.90mtr |
| 50 | 6 Sqmm copper wire single core havells / polycab or equ.90mtr |
| 51 | 4 Sqmm copper wire single core havells / polycab or equ.90mtr |
| 52 | 2.5 sqmm copper wire single core havells / polycab or equ.90mtr |
| 53 | 1.5 Sqmm copper wire single core havells / polycab or equ.90mt |
| 54 | 10 Sqmm 2 core Aluminium wire havells / polycab or equ.90mtr |
| 55 | LED tubelight 22WATT with complete fitting wall ISI marked |
| 56 | \\"Removal of malba/rubbish by mechanical transportation upto dumping ground lead 10 to 15 km approx.\\" |
| 57 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes |
| 58 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.1.1 35 mm thick shutters |
| 59 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : 9.7.1 Second class teak wood |
| 60 | Provision for providing MS Portable Toilet cabin for ladies and gents, requirement for gents toilet 2Urinal and 2WC, 2WC in ladies toilet, 1WC-Disabled toilet with washbasin and all other accessories of lighting ,exhaust , water tank etc complete in cabin. size of cabin should be (20'x8'x8.5' size ) as per approved design and specifications of cabin and matching color to monument. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender