Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #57694446

Tender For Repair Maintenance And Replacement Of Main/ Entire Distribution Pipeline Network Feeding, Ci/ Gi/ Hdpe/ Pvc Pipes/ Valves And Allied Works At Hq Ub Area Units, Fafa, Dca Colony, Lokhart Line, Sarvatra, Other Otm And Married Accn Of Ub Area

Issued by Statutory Bodies & Commissions/Committees · Bareilly, Uttar Pradesh
Tender Value
83.69 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
2 days left
EMD
1.50 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bareilly → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair Maintenance And Replacement Of Main/ Entire Distribution Pipeline Network Feeding, Ci/ Gi/ Hdpe/ Pvc Pipes/ Valves And Allied Works At Hq Ub Area Units, Fafa, Dca Colony, Lokhart Line, Sarvatra, Other Otm And Married Accn Of Ub Area, Mh, Jrc, Jla, Pb Marg And Maried Accn Area Under Ge (East) Bareilly

BOQ

Name of Work:- REPAIR MAINT AND REPLACEMENT OF MAIN/ ENTIRE DISTRIBUTION PIPELINE NETWORK FEEDING, CI/ GI/ HDPE/ PVC PIPES/ VALVES AND ALLIED WORKS AT HQ UB AREA UNITS, FAFA, DCA COLONY, LOKHART LINE, SARVATRA, OTHER OTM AND MARRIED ACCN OF UB AREA, MH, JRC, JLA, PB MARG AND MARIED ACCN AREA UNDER GE (EAST) BAREILLY
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER BAREILLY Name of Work: REPAIR MAINT AND REPLACEMENT OF MAIN/ ENTIRE DISTRIBUTION PIPELINE NETWORK FEEDING, CI/ GI/ HDPE/ PVC PIPES/ VALVES AND ALLIED WORKS AT HQ UB AREA UNITS, FAFA, DCA COLONY, LOKHART LINE, SARVATRA, OTHER OTM AND MARRIED ACCN OF UB AREA, MH, JRC, JLA, PB MARG AND MARIED ACCN AREA UNDER GE (EAST) BAREILLY Contract No : CWE / BLY / GE(E) /120 OF 2026-27 Bidder Name : SCHEDULE A(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2Supply, Laying, jointing and testing GI Pipe medium grade including all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches and including dismantling and taking down unserviceable / cracked steel tubing with all fittings of the following sizes as complete all as specified and as directed at site of the following sizes :-Note :- Excavation and other earth work will measured and paid separtely for respective items.
380 mm dia
450 mm dia
540 mm dia
625 mm dia
720 mm dia
815 mm dia
9S&F Gun-metal, globe or Gate Valve with iron wheel head, screwed bothe ends for iron pipe, ISI marked including taking down of unserviceabel existing gate valve complete all as specified and directed of the following sizes:-
1080 mm dia
1150 mm dia
1240 mm dia
1325mm dia
1420mm dia
1515mm dia
16Supply and laying of centrifugally cast (Spun) ductile iron pressure pipe with spigot & socket end, class K-9 in any length laid in trenches, conforming to IS-8329/2000 with cement mortar lining with and including rubber gasket jointing conforming to IS-15382/ tyton joint and including dismantling and taking down unserviceable / cracked DI pipe with all fittings complete all as specified and directed for the following sizes:-
17100 mm dia
18150 mm dia
19Supply and fixing DI fittings for Flanged pipe, DI Bends, connecting pieces, bell mouth pieces, tapers, tee pieces of one end flanged and other end spigot or socket upto 150 mm bore complete all as specified and directed.
20M&L for Rubber gasket joint Spigot and socketed pipes and fittings for the following bore complete all as specified
2180 mm dia
22100 mm dia
23150 mm dia
24Taking up cast iron water mains (including all fittings),with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed for the following sizes:-
25100 mm dia
26150 mm dia
27Supply and laying in trenches of CI Pipe centrifugally cast, spigot & socket ends pipes, Class LA, including all fittings with lead Joints and including dismantling and taking down unserviceable/cracked CI pipe with all fitting burning out joints and recovering lead complete all as specified and directed for the following sizes:-
28150mm dia
29100mm dia
30M&L for run lead joint Spigot and socketed pipes and fittings for the following bore complete all as specified
3180 mm dia
32100 mm dia
33150 mm dia
34Supply and fixing CI fittings for Socketed pipe, CI Bends, connecting pieces, bell mouth pieces, tapers, tee pieces of one end flanged and other end spigot or socket upto 150 mm bore complete all as specified and directed.
35M&L for lead wool joint Spigot and socketed pipes and fittings for the following bore complete all as specified
3680 mm dia
37100 mm dia
38150 mm dia
39M&L for wash out points by proper cutting and screwing of existing DI/CI/GI pipe fixing reducer, tee and MS/CI pipe line of suitable size, supplying and fixing, Jointing, testing CI sluice valve of following size by fixing 01 No. at each wash out point with flanged ends including necessary mountings nuts, bolts washers and packing fibers gasket on both end and making valve pit chamber of size 1.2 x 1.2 x 1 Mtr including iron frame cover 3.15 mm thick with locking arrangements including dismantling old valve pit chamber with fittings complete all as specified and directed for the following sizes:-
40Wash out point at 150 mm dia pipe
41Wash out point at 100 mm dia pipe
42Wash out point at 80 mm dia pipe
43Wash out point at 50 mm dia pipe
44M&L for construction of brick masonry valve pit of size 1.2x1.2x90cm (internal dimension) one brick thick wall built in CM (1:4) on 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foundation, and 15mm thick rendering in cement mortar (1:4) both externally and internally, external plaster shall be up to 15cm below GL, providing valve pit cover made of 3.15mm thick MS sheet/plate, including provision of hinges, handle and locking arrangement including 40 X 40 X 5mm angle iron frame fixed on top of valve pit by means of MS hold fast 40x5mm and 150mm long, embedded in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) including two coats of anti-corrosive paint over a coat of red oxide zinc Chrome primer and necessary earth work in soft/loose soil including demolition of old unserviceable existing valve pit & pit cover complete all as specified & directed.
45All as item Ser No. 12 but valve pit of size 600 x 600 x 600 mm
46Dismantling and taking out sluice valve any size and ,M&L for repair sluice valve for 100 mm to 200 mm bore , high tensile stainless steel spindle, including nuts, bolts and gas kit ,glands and refixing after repair etc. complete all as specified and directed.
47S&F in repair sluice valve class PN-1.6 heavy duty flanged ends drilled ISI marked confirming to IS: 14846, wheel operated (Handle) with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. complete including taking out old existing unservicable sluice valve including making arrangement for safe working all as specified and directed.for the following sizes:-
48150 mm dia
49100 mm dia
5080 mm dia
51200 mm dia
52S&F CI Non Return Sluice Valve flanged ends of class 1.6 PN, including taking down old existing unserviceable Non Return Valve complete all as specified and directed for the following sizes:-
53150 mm dia
54100 mm dia
5580 mm dia
56Supply and fixing in replacement high density polypropylene full bore ball valve, flanged end, having three piece body made of HDPE material, one spindle of stainless steel, two numbers PTFE seat ring, connector seal, stainless steel (SS 316) nuts, bolts, mild steel PP coated operating handle, stainless steel handle hex pin, ISI marked , both side flanged as per ANSI, suiatble to withstand upto 16 Kg/sqcm pressure complete in all respect including supply and fixing of HDPE flanged on the HDPE pipe as per valve/site requirement along with all fixing/fitting material, testing the valve at full pressure against the leakage and full bore flow and suitable for the following sizes of HDPE pipe complete all as specified and directed.
5775 mm outer dia
5865 mm outer dia
5950 mm outer dia
60Supply & laying/fixing Floor & Trench,3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded PP-R (polypropylene Random Co-Polymer) pipes, ISI marked including plain PP-R fittings and brass threaded PP-R fittings such as flanges, elbow, bend, sockets, tee etc. as required at site and testing of joints complete all as specified and as directed of size:-
61PN-16, 50 mm OD (SDR– 7.4)
62PN-16, 75 mm OD (SDR– 7.4)
63PN-16, 90 mm OD (SDR – 7.4)
64PN-16, 25 mm OD (SDR – 7.4)
65PN-16, 32 mm OD (SDR – 7.4)
66Making connection of PP-R distribution branches 75 to 110 with PP-R main of following size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
67Making connection of PP-R distribution branches 50 to 75 with PP-R main of following size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
68S&F in replacement PPR gate valve (brass insert) of size 75 mm bore including connection and testing complete all as directed.
69S&F in replacement PPR gate valve (brass insert) of size 50 mm bore including connection and testing complete all as directed.
70M&L for Painting to pipe of pump house rising mains hydrants, sluice valves, pipe, fittings, NRV, discharge head etc after cleaning, scrapping and making the surfaces free from rust of main externally and painting with two coats synthetic enamelled paint in black / blue / red including marking / writing on pipe etc complete as specified and directed.
71Supply & installation in replacement of Chlorine dozing system with dosing System, with Non-metalic solution tank of 100ltrs capacity with motor driven agitator to maintan uniform suspension throughout the tank electrically operated chlorine dosing tank consisting of Dosing tank 100 ltr of PE/FRP Lid & level gauge along with single phase electric motor and agitator, 90 watts, 1440 RPM, 230 volts, 50 cycles, 02 AMP and having speed controller to reduce upto 800RPM, with shaft & blade in plastic-mounted on tank Lid must have port hole for pouring calcium hypochlorite and water when necessary. Lid must have provision for mounting dosing pump on the lid/wall including High pressure Single head Gear motored adjusable Dosing Pump set, uneffected on dry running having no loss of prime, independent of back pressure and able to handle both chemical solution as well as suspension, 230volts, 50 cycles, AC,44 RPM 1/30 fraction HP having output 2US GPD to 40 U.S GPD complete with accessories i.e lead tubing , connecting nuts, injection check valve, clay weight and ferrules including complete all as specified and directed by Engr-in-charge.
72M&L for repair/rectification of leakage/blockage to water supply distribution lines of following bore of GI tubing by necessary excavation, returning /filling as required , tightening of lose joints of union ,elbow, socket, nipple as per site requirement including for replacement of GI union ,socket, nipple as required complete all as directed.
73(a) 20mm bore to 25 mm bore
74(b) 40mm bore to 50 mm b ore
75M&L for dewatering complete trenches manually for repairing joints by cocking and inserting spurn yarn and Run lead joint, flange, tail piece , socket making good/ leakless the joint/leakage including necessary excavation and earth work like returning, filling etc for pipes of following bore complete all as directed. Note for item No.26 & 27 - 1. Plumber and helper will report daily to office for collecting complaint docket and will return the same after rectifying the complaint.2. A penalty of Rs. 500 per complaint will be imposed if the same not attended within 12 Hrs after receiving the complaint 3. Contractor shall arrange open well submersible pumpset for draining out the water from trench and JCB and other eqpt for excavation as per site requirement for timely/fastly rectifying the leakage and restoring water supply4. Rate quoted shall deemed to be inclusivev of all items mentioned above
76(a) 80 mm bore
77(b) 100 mm bore
78(c) 150 mm bore
79(d) 200 mm bore
80S&F of 'D' Joint of following bore complete all as specified and directed.
81(a) 80mm bore
82(b) 100 mm bore
83(c) 150 mm bore
84(d) 200 mm bore
85M&L for running welding in any position as and where directed n.exc 6mm gitrh (thickness of metal to be welded) complete all as specified and as directed.
86S & F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms) including GI fittings as per site reqmt
87Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope / gradient for laying cables/ pipes etc. all as specified and directed including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as specified and directed.Note : Excavation shall be made carefully in order to avoid damage of existing cables/pipes and protection covers.
88Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed
89Removal of surplus excavated soil exc. 50 mtr but n. exc. 250 mtr distance and depositing where directed at a level not exceeding 1.5 M above the starting point etc complete all as directed.
90M&L for boring the holes under roads pavements, hardstanding by treanch less techonology, using ultrasound technique and necessary machine including DI/CI/GI/HDPE/PP-R Pipe of 25 mm to 150 mm bore suitable for 0.4 mpa working pressure complete all as specified and directed.
91Dismantling and takiny out interlocking /chequered tiles from path way and keeping aside or safe custory for reuse including replacement of damaged tiles after laying of pipe line/ rectification of leakage including necessary Sand, PCC work required as per site requirement, making disturbed surface good as original complete all as specified and directed.
92Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 1.50 Km and n.exc 5.00 Km etc complete all as specified and directed.
93M&L for PCC 1:2:4, type B1 (using 20 mm graded granite stone aggregate) as in coping for steel pole including necessary formwork complete all as specified.
94M&L for PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) for road/Hard standing cutting complete all as specified and as directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57694446
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 83.69 Lakhs
LAST DATE 22-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair Maintenance And Replacement Of Main/ Entire Distribution Pipeline Network Feeding, Ci/ Gi/ Hdpe/ Pvc Pipes/ Valves And Allied Works At Hq Ub Area Units, Fafa, Dca Colony, Lokhart Line, Sarvatra, Other Otm And Married Accn Of Ub Area, Mh, Jrc, Jla, Pb Marg And Maried Accn Area Under Ge (East) Bareilly
Basic Detail
Tender No 8200/B/967/E8
Bidding Type Tender
Location
City Bareilly
State Uttar Pradesh
Key Dates
Publish Date 24 Sep 2026
Submission Date 22 Oct 2026
Open Date 29 Oct 2026
Finance
Tender Value 83.69 Lakhs
Tender Fee 1000
EMD 1.50 Lakhs
Exemption Available
Document List
BOQ_886727.xls
cc2d3cdc-7eda-4295-a340-b7cd4ed0ecd3.html
PS_120.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Oct 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_886727.xls

html

cc2d3cdc-7eda-4295-a340-b7cd4ed0ecd3.html

pdf

PS_120.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender