Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #57694408

Tender For Repair/ Replacement Of Lt Ug Cable, Earthing, Lightening Arrester, Do Switch, Mccbs & Connected Items At Kk Ranges, Btr & At Various Locations & Adjacent Area Of Acc&S & Stn Units Under Ge(N) Ahilyanagar.

Issued by Statutory Bodies & Commissions/Committees · Ahmednagar, Maharashtra
Tender Value
25 Lakhs
Estimated cost
Bid Submission
15 Oct 2026
11 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ahmednagar → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement Of Lt Ug Cable, Earthing, Lightening Arrester, Do Switch, Mccbs & Connected Items At Kk Ranges, Btr & At Various Locations & Adjacent Area Of Acc&S & Stn Units Under Ge(N) Ahilyanagar.

BOQ

Name of Work:- REPAIR/ REPLACEMENT OF LT UG CABLE, EARTHING, LIGHTENING ARRESTER, DO SWITCH, MCCBS & CONNECTED ITEMS AT KK RANGES, BTR & AT VARIOUS LOCATIONS & ADJACENT AREA OF ACC&S & STN UNITS UNDER GE(N) AHILYANAGAR.
Sl. No. Item Description
1Supply & Fixing and testing of LT cable 1100 volts grade, XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) ISI Marked with aluminium conductor suitable for earthed system of following sizes in trenches, on poles and in ducts complete all as specified and directed by Engr in charge.
2.-ditto- all asper ser item no 1 above but size 120 sq mm 3½ core
3.-ditto- all asper ser item no 1 above but size 95 sq mm 3½ core
4.-ditto- all asper ser item no 1 above but size 70 sq mm 3½ core
5.-ditto- all asper ser item no 1 above but size 50 sq mm 3½ core.Note for Ser Item No 02 to 05 : Excavation & Earthwork, pipe protection shall be measured and paid seprately under the relevant item of this Schedule.
6Excavation in trenches nexc 1.5 mtr in depth and not exceeding 1.5 Mtr wide for laying of cable/ pipe etc and getting out in any type of soil complete all as specified and directed.
7Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm thick each layer as in soil complete all as specified and directed..
8Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
9Supply & laying of HDPE DWC pipe ISI mark of outer dia 110 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specified and directed by Engineer-in-ChargeMake : Supreme / Infra / Astral/Prince/jain irrigation
10Supply & laying of HDPE DWC pipe ISI mark of outer dia 63 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specified and directed by Engineer-in-ChargeMake : Supreme / Infra / Astral/Prince/jain irrigation
11M&L for GI Tubes, of size 80mm dia Medium grade, galvanised, with all fitting, laid in trenches for protection of cable in road / drain crossing complete all as specified and as directed.
12M&L for road cutting upto 300mm deep and 200mm wide for crossing GI pipe line through road including making good the disturbed surface by filling mass concrete( 1:2:4) etc complete all as specified and directed by Engineer-in-Charge..Note : Rate of mass concrete is included in quated rate.
13Dismantling carefully the existing LT overhead line ACSR conductor with cross arm of any size from its position by necessary disconnecting of conductor and removing complete all as specified and as directed
14Dismantling of unserviceable existing cross arms made from channels, angles and unserviceable FI clamps, nuts, bolts etc from OH line and removing complete all as specified and as directed
15S&F PCC Cable route Indicator with suitable reinforcement of size 50 x 10 x 10 cm with letter inscribed on both side as \\"MES LT CABLE \\" of specified front side not less than 30 mm as directed and complete using PCC 1: 2:4 B1 using 20 mm graded stone aggregate and including painting using cement based paint to the satisfaction of Engr-in-charge.
16M&L for prunning and removing of tree branches touching to electric over head lines wild growth around LT /HT over head lines and around pole and stay complete to make clear span of 2 Mtr of tree both side of the OH line with JCB, Cutter and all tools, plants etc all as directed by Engineer-in-Charge.Note : (i) Distance between pole to pole will be measured and paid. (ii) Contractor has to take upmost care to avoid damage to existing lines/ structures if any breakdown of line caused during prunning shall be made good without any extra cost. (iii) The contractor has to ensure the proper safety of the tradesmans to avoid any mishappening. If any mishappening occures the contractor will be solely responsible for it.
17M & L for replacement of Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade
18M & L for replacement of shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers,insulator bolts, washers and nuts, 100mm height and 115mm dia including two nos of galvanised steel strap of size 31x5 mm fitted with 14mm dia bolts and nuts all as per directed.
19Supply, fixing and stringing ACSR conductor (Weasel/ Ferret) for over head line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc of any size all as specified and as directed. (Note :- (a)jumper on cutout point/2 pole structer/4 pole structure shall be provided with PVC insulated sleeve. (b) Rate is inclusive of jumpers materials & tree branch cutting to make a safe distance from over head line.)
20M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete for poles/struts, stay assembly etc. including necessary formwork complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information
21M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete for poles/struts, stay assembly etc. including necessary formwork complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57694408
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 15-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement Of Lt Ug Cable, Earthing, Lightening Arrester, Do Switch, Mccbs & Connected Items At Kk Ranges, Btr & At Various Locations & Adjacent Area Of Acc&S & Stn Units Under Ge(N) Ahilyanagar.
Basic Detail
Tender No 8310/E8
Bidding Type Tender
Location
City Ahmednagar
State Maharashtra
Key Dates
Publish Date 24 Sep 2026
Submission Date 15 Oct 2026
Open Date 17 Oct 2026
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Available
Document List
4f2cd08d-1c84-4d3d-89e0-d8d9fefb50d1.html
BOQ_886763.xls
TenderDOCUS8310.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Oct 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

4f2cd08d-1c84-4d3d-89e0-d8d9fefb50d1.html

xls

BOQ_886763.xls

pdf

TenderDOCUS8310.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders