Tender For Rep/Maint Of Chain Link Fencing And Other Misc Work At 19 Ad Regt, 707 Tsu, 955 Ad Regt And Rep/Repl Of Deteriorated Ms Pipe Line, Control Panels, Non Clogging Pump Sets, Dozing Systems, Rewinding And Servicing Of Air Blowers, Valves And A
Tender Overview
Project Description
Tender for Rep/Maint Of Chain Link Fencing And Other Misc Work At 19 Ad Regt, 707 Tsu, 955 Ad Regt And Rep/Repl Of Deteriorated Ms Pipe Line, Control Panels, Non Clogging Pump Sets, Dozing Systems, Rewinding And Servicing Of Air Blowers, Valves And Allied Works At Sewage Treatment Installations Under Ge (I) Gos
BOQ
| Sl. No. | Item Description |
| 1 | M&L for dismanting complete Air compressor set of any type & overhauling the same with repair,checking,cleaning of dirt & debris,proper belt tension, lubricating of bearing,gear, checking of wornout holes of studs and providing same with nuts,washers & gaskets.Rematting and balancing of piston,with & including replacement of piston rings,Split pin,scrapper ring,castle nuts,bushing and sealing ring of compressor,gland packing,and refitting the same after repair duly and replacing suction air filter,pulley belt,pulley bush with proper alignment and painting complete all as specified and directed for smooth functioning of capacity 1-3 HP |
| 2 | All as per item no 1 above but of capacity 5-7.5 HP |
| 3 | All as per item no 1 above but of capacity 10-15 HP |
| 4 | All as per item no 1 above but of capacity 20-30 HP |
| 5 | S & Fix in replacement of sluice valve 100 mm dia of existing model complete all as specified and directed. |
| 6 | S & F in replacement butterfly valve of dia 100 mm all as specified and directed by Engr-in-Charge: |
| 7 | All as per item No 6 above but 80 MM dia |
| 8 | All as per item No 6 above but 65 MM dia |
| 9 | All as per item No 6 above but 50 MM dia |
| 10 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying of U/G cables not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil. |
| 11 | Returning filling in soil icluding spreading levelling watering and well ramming in layers not exc. 25 cm thick . |
| 12 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 above the starting point including spreading and levelling complete all as directed |
| 13 | Taking up or down steel tubing/ PPR pipes and connections including cleaning and re fixing or removal to store of size 90 - 110 MM (Note:- Excavation/Earth work will be measured and paid seperately) |
| 14 | All as per item No 13 above but 50-63 MM dia |
| 15 | All as per item No 13 above but 25 - 40 MM dia |
| 16 | All as per item No 13 above but 15 - 20 MM dia |
| 17 | Refixing old steel tubing / PPR pipes and connections in new or old positions of dia 90-110 MM (walls/ceiling/floor etc ) |
| 18 | All as per item No 17 above but 50-63 MM dia |
| 19 | All as per item No 17 above but 25-40 MM dia |
| 20 | All as per item No 17 above but 15-20 MM dia |
| 21 | S & Fix in replacement of sluice valve upto 80 mm dia of existing model complete all as specified and directed. |
| 22 | Supply and filling Filter media for MBBR to ensure proper filtration complete all as specified and directed. |
| 23 | Supply and filling suitable Carbon media for activated carbon filter and filter media for dual media filter complete all as specified and directed. |
| 24 | S&F in replacement Fiber strainer of suitable size for activated carbon filter and dual media filter complete all as specified and directed. |
| 25 | M&L for Dismantling the power supply of electric motor any type including dismantling from pump and taking to workshop with necessary transportation if required and opening the complete motor and rewinding the rotor with super enameled copper wire as per the existing gauge with necessary insulation, sticks and varnishing, including replacement of shaft bearing 02 Nos complete with painting of capacity 20 to 30 HP complete all as specified and directed. |
| 26 | All as per item No.25 above but of capacity 10 to 15 HP electric motor any type. |
| 27 | All as per item No.25 above but of capacity 5 to 7.5 HP electric motor any type. |
| 28 | All as per item No.25 above but 1 to 3 HP electric motor any type. |
| 29 | S&F in replacement PPR gate valve/ball valve (brass insert) complete all as specified and directed of 110 mm outer dia- |
| 30 | All as per item no 29 above but of size 90 mm outer dia |
| 31 | All as per item no 29 above but of size 63 mm outer dia |
| 32 | All as per item no 29 above but of size 50 mm outer dia |
| 33 | All as per item no 29 above but of size 40 mm outer dia |
| 34 | All as per item no 29 above but of size 32 mm outer dia |
| 35 | M&L for Cleaning of sludge drying beds removing all sludges and de-scaling vegetation on the inside and outside of sludge bed and white washing (Two Coat) including Cleaning the surroundings area of the sludge drying beds to a distance of 3 mtrs circumstance including cutting of grass digging out roots, filling holes and levelling around and removing waste materials to a distance not exceeding 50 Mtrs complete including masonary work to make good the surfaces as required at site all as directed. |
| 36 | All as per item No 35 but Equilization Tank and air grid. |
| 37 | All as per item No 35 but Bar screen and pit. |
| 38 | All as per item No 35 but Oil and grease trap . |
| 39 | All as per item No 35 above but Tube settler tank. |
| 40 | All as per item No 35 but Clear water tank. |
| 41 | All as per item No 35 but chlorine contact tank. |
| 42 | All as per item No 35 but Sludge holding tank |
| 43 | M&L for cleaning, removing all sludge and preparation of old surface by scraping and smoothing the surface with water emery paper and painting with approved colour of synthetic enemelled paint of two coat over a coat of primer red oxide and writing letters/numbers of sewage treatment plants of any capacities and cleaning the surrounding area up to three metre out side area of the plant by cutting grasses and surface dressing for Moving Bed Bio Reactors 1 & 2 including petty nature repairs etc all as directed by Engr in Charge. |
| 44 | All as per item No 43 above but dual Media filter. |
| 45 | All as per item No 43 above but Activated carbon filter. |
| 46 | All as per item No 43 above but Exposed water pipe lines. |
| 47 | All as per item No 43 above but distribution panel board. |
| 48 | All as per item No 43 above but Tube settler tank. |
| 49 | S&F in replacement Dosing Tank of capacity upto 250 ltrs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including all necessary connecting materials complete all as specified and directed by engg- in - charge |
| 50 | M&L for dismanting complete sludge drying machine of any type & overhauling the same with repair,checking,cleaning of dirt & debris,proper lubricating of bearing, checking of wornout holes of studs and providing same with nuts,washers & gaskets.Rematting and balancing of shaft,with & including replacement of broken parts and refitting the same after repair duly painting for its complete operation all as specified and directed for smooth functioning of capacity upto 800 KLD plant. |
| 51 | S & Fixing in replacement of non return valve upto 80 mm dia complete all as specified and directed. |
| 52 | S & Fixing in replacement of non return valve 100 mm dia complete all as specified and directed. |
| 53 | M&L for collection of Treated water samples from various Sewage Treatment Plants located at different area in white colour PVC containers of capacity not less than 10.0 Ltr, hygenically dry, neat & clean and transporting the same to laboratory for followings tests of water from Government approved/certified laboratory seperately for each STP and submitt the test results complete all as specified and directed as mentioned below :- (a)PH Value (b) Residual Chlorine(c) Cemical Oxygen demand(d) Biochemical oxygen demand(e) Total suspended solid(f) Total Coliform(g) Oil & Grease |
| 54 | M&L for Dismantling complete Centrifugal /Mono Block/non clog pump set of any type and overhauling the pump re-threading of wornout holes of studs and providing over size studs with nuts & washers. Rematlling and balancing of shaft, replacement of gunmetal bush bearing and gland packing of pump set. and refitting the same after the repair/replacement duly all as specified and tested for smooth functioning with painting of capacity 20 to 30 HP |
| 55 | All as per item No-54 above but capacity 10 to 15 HP |
| 56 | All as per item No-54 above but capacity 5 to 7.5 HP |
| 57 | All as per item No- 54 above but capacity 1 to 3 HP |
| 58 | S&F in replacement tube settler media as per existing shape and size complete all as specified and directed. |
| 59 | S&F in replacement of Dosing Pump of capacity 0-6 litrs/Hrs and working pressure capacity of 4 kg incl all necessary fittings complete all as specified and directed by engg- in - charge |
| 60 | M&L in repair mild steel work for Cross arms, /angle supports bracings, supports, clamps and black plates fabricated from structural steel section including nuts, bolts, washers, welding ,bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including taking out existing u/s MS work complete all as directed. |
| 61 | Supply and laying or fixing or passing in repalcement in well/sump in replacement, 1100 volts grade heavy duty, PVC insulated and PVC sheathed mutistranded copper conductor submesible cable 3 core flat including connection to submersible motor/ starter panel with & including necessary jointing materials if required and testing on completion complete all as specified and direced of size 4 SQMM |
| 62 | All as per item no 61 above but of size 10 Sqmm |
| 63 | All as per item no 61 above but of size 16 Sqmm |
| 64 | S&F in repalcement fully automatic star- delta starter of capacity suitable for and upto 30.0 HP motor, AC-3 duty, 415 volts, 50 Hz, three phase including fixing arrangement complete all as specified and directed. |
| 65 | S & F in replacement DOL starter for pump motor of capacity upto 10 HP, AC-3 duty, 415 volts, 50 Hz, three phase including fixing arrangement complete all as specified and directed. |
| 66 | S & F in replacement DOL starter for pump motor of capacity upto 15 HP, AC-3 duty, 415 volts, 50 Hz, three phase including fixing arrangement complete all as specified and directed. |
| 67 | Cleaning of under ground RCC Reservior of capacity upto 1 lakh gallon having single or double compartment by scraping sludge ,bleaching sediments deposition and other foreign material with wire brush from inner surface of domes, taking out including washing with bleaching powder solution /Potassium permanganate solution complete with entire satisfaction of engineer-in -charge including writting date of the cleaning & capacity of Reservior complete all as specified and directed.Note: (i) All T&P and risk shall be contractor's liability.All T&P shall be arranged by contractor without any extra cost.(ii) Sludge obtained shall be deposited at 50 mtr away complete all as directed by Engr -in-Charge. |
| 68 | Supply and filling lubricant oil (20W/40 Gde) incl draining out old oil from FAB feed pumps of any capacity and cleaning oil chamber as required complete all as specified and directed by Engr in Charge |
| 69 | Supply and fix in replacement thermal over load relay of range upto 23 Amps complete all as specified and directed. |
| 70 | Supply and fix in replacement of indicating lamp set (RYB) LED type complete. |
| 71 | Suppy and use liquid chlorine complete all as specified and directed |
| 72 | Supply and filling lubricant oil (320 Gde) including draining out old oil from air blowers compressor of any capacity and cleaning oil chamber as required complete all as specified and directed by Engr in Charge |
| 73 | Supply and use Poly electrolite liquid 100% concentrate complete all as specified and directed. |
| 74 | M&L for Checking and inspecting of the LT outdoor type panel board system throughly, including removing of the unserviceable damaged control wiring and rewiring of the same with suitable size and length of copper conductor FRLS , checking of instruments , welding of panels,cleaning with bakelite and carried out of necessary painting matching with existing colour including tightining for all the loose contacts, reconnecting back and testing complete all as specified and directed . |
| 75 | Supply and use Poly aluminium chloride 100% concentrate complete all as specified and directed. |
| 76 | S& F in replacement 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings excluding MTR, FTR fittings fixed complete to walls, celling,floors or in trenches etc of 110 mm outer dia. (Note:- All fittings including FTR/MTR fittings will be measured and paid seperately up to 90 mm pipe/FTR/MTR Fittings only measured seperately for 63 to 32 mm) |
| 77 | All as per item no 76 above but of size 90 mm outer dia |
| 78 | All as per item no 76 above but of size 63 mm outer dia |
| 79 | All as per item no 76 above but of size 50 mm outer dia |
| 80 | All as per item no 76 above but of size 40 mm outer dia |
| 81 | All as per item no 76 above but of size 32 mm outer dia |
| 82 | All as per item no 76 above but of size 25 mm outer dia |
| 83 | All as per item no 76 above but of size 20 mm outer dia |
| 84 | All as per item no 76 above but of size 16 mm outer dia |
| 85 | Supply and use bleaching powder ISI marked as directed by Engr in Charge |
| 86 | Supply and fix in replacement thermal over load relay of range above 23 amps and upto 50 Amps complete all as specified and directed. |
| 87 | S&F in replacement contactor NO+NC 16 Amps capacity 240 volts, 50 HZ, DP complete all as specified and directed . |
| 88 | S&F in replacement contactor NO+NC 9 Amps capacity 230 volts, 50 Hz, DP complete all as specified and directed. |
| 89 | S&F in replacement PPR female threaded socket (brass insert) complete all as specified and directed of 110MM outer dia- |
| 90 | All as per item no 89 above but of size 90 mm outer dia |
| 91 | All as per item no 89 above but of size 63 mm outer dia |
| 92 | All as per item no 89 above but of size 50 mm outer dia |
| 93 | All as per item no 89 above but of size 40 mm outer dia |
| 94 | All as per item no 89 above but of size 32 mm outer dia |
| 95 | S&F in replacement PPR male threaded socket (brass insert) complete all as specified and directed of 110 MM outer dia- |
| 96 | All as per item no 95 above but of size 90 mm outer dia |
| 97 | All as per item no 95 above but of size 63 mm outer dia |
| 98 | All as per item no 95 above but of size 50 mm outer dia |
| 99 | All as per item no 95 above but of size 40 mm outer dia |
| 100 | All as per item no 95 above but of size 32 mm outer dia |
| 101 | Supply only PPR fittings of Elbow 90 degree complete all as specified and directed of 110mm outer dia- |
| 102 | All as per item no 101 above but of 45 degree Elbow 110 MM |
| 103 | All as per item no 101 above but of socket 110 MM |
| 104 | All as per item no 101 above but of Tee 110 MM |
| 105 | All as per item no 101 above but of Flange 110 MM |
| 106 | Supply only PPR fittings of Elbow 90 degree complete all as specified and directed of 90mm outer dia- |
| 107 | All as per item no 106 above but of 45 degree Elbow 90 MM |
| 108 | All as per item no 106 above but of Socket 90 MM |
| 109 | All as per item no 106 above but of Tee 90 MM |
| 110 | All as per item no 106 above but of Flange 90 MM |
| 111 | S&F in replacement of FAB feed pump spiders complete all as specified and directed |
| 112 | Supply and replacement battery 12 volts 150 AH complete to dg set all as specified and directed. |
| 113 | Supply and replacement battery 12 volts 100 AH complete to dg set all as specified and directed. |
| 114 | Dismantling of AC/GI plain/Corrugated / semi corrugated roof sheets any type and any size complete all as specified and directed. |
| 115 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed. |
| 116 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed by Engineer-in-Charge. |
| 117 | S&F Mild steel work in tubular poles & trusses (framed) including purlins,rafters and special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade St-240 complete all as specified and as directed by Engineer-in-Charge. |
| 118 | S & F steel Fe-410-W (Gde 250 Quality-A) work in tubular stanchion/post including special shaped washer etc. complete using one of more tubes or induction butt welded tubes conforming to IS-1161- 1979 grade St.-240 complete all as specified and directed. |
| 119 | S&F mild steel work Fe-410-W (Gde 250 Quality-A) in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and as directed by Engineer-in-Charge. |
| 120 | M&L for MS Framed work of Fe 410 W (Gde-E-250) Quality A, as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 121 | M&L for preparation of new/old or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 122 | Excavation in post holes (or similar holes) each n exc. 0.5cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layer n.exc. 25cm complete all as specified |
| 123 | Demolition of cement concrete unreinforced in ground floor and paving not exc 15cm thick (below or above ground level) complete all as specified and directed. |
| 124 | M & L P:C:C 1:4:8 Type D2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 125 | M&L for 100 mm thick Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 126 | M&L for 50 mm thick Cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring incl finished cement concrete surface even and smooth complete all as specified and directed. |
| 127 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in floor 100 mm thick surface finished even and smooth complete all as specified and directed. |
| 128 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in floor 25 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed. |
| 129 | M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 130 | Material and labour for 75mm thick PCC 1:3:6 Type C2 (40mm graded stone agg) as in plinth protection, surface is to be finished even and fair without using extra cement complete all as spd and directed |
| 131 | M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring benching, roof kerbs or mud stops rounded or chamfered on edges including necessary use and waste of form work complete all as specified and as directed. |
| 132 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 133 | M&L for Pre Polished Chequered cement concrete tiles of size 200 mm x 200 mm x 25 mm thick set jointed and pointed in neat cement slurry in floor and cut and polished with grey cement and pigment, including 20 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 134 | M&L for Vitrified Parking Tiles of size 300 mm x 300 mm x 10 mm thick set jointed and pointed in neat cement slurry in floor and cut and polished with grey cement and pigment, complete all as specified and directed. 20 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 135 | M&L for Screed bed or bedding layer of mortar 15 mm thick for laying floorfinishes complete all as specified and directed. |
| 136 | S&F machine pressed precast concrete Pre Polished interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed. |
| 137 | M&L for sand cushioning including spreading in layers and rolled consolidated to thickness of 50mm (minimum) for receiving precast PCC interlocking blocks complete all as specified and directed |
| 138 | M&L for machine cut kota stone slab flooring 18- 20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 20mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 139 | M&L for machine cut kota stone slab18- 20 mm thick as in dado, riser, steps and the likes laid over and including rendering 15mm thick in CM 1:4 for bedding layer complete all as specified and as directed. |
| 140 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 141 | M&L for walling of squared rubble, regular coursed, well bonded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed. |
| 142 | M&L old size Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 143 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified. |
| 144 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in Cement concrete in surface channels and drains surface finished even and smooth complete all as specified and directed. |
| 145 | M&L hard core gauge n.exc 63 mm deposited spread & levelled in layars n exc 15 cm thick watered & rammed in a true surface using broken stone or boulder . |
| 146 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface of wall and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 147 | M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surface of wall and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 148 | Supply only integral water proofing compound all as specified and directed. |
| 149 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and removal of rubbish from site complete all as specified and directed |
| 150 | M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:4 complete all as specified and directed. |
| 151 | Dismantling posts or struts (wood, steel or RCC) any section,concrete ,brick work ,massonery etc . including taking out embedded portion and making good disturbed ground complete all speciified and directed |
| 152 | Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area n exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed |
| 153 | M&L TMT bar 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 154 | Ditto all as Item No-37 above but 6 to 8mm dia as in stirrups |
| 155 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cm and n exc 15cm long and dia of neck 11 mm to 15 mm |
| 156 | Form work to sides of concrete foundations, footings, bases of columns, raft and rafts beams, sides and soffits (in any ) of foundation and plinth beams etc and similar work, vertical or to batter for Fair finished surfaces complete all as specified and directed. |
| 157 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 158 | S & F of angle iron and flat iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 159 | Dismantling fencing wire mesh any size or type,and removing the site complete all speciified and directed |
| 160 | S&F PVC insulated chain link fencing including line wire of size 3.15 mm dia and 100x100 mm mesh made up in mattresses or cases, lapped wire and laid in position to RCC fenccing and straining and fixing to any type of posts, straining bolts, standard bolt, incl securing or tying at crossing with and including provision of galvanized mild steel wire sraples or steel pins etc complete all as specified and directed (each line of wire to be measured for the purpose of payment) |
| 161 | S&F Flat Iron strip for securing chain link fencing with RCC posts incl drilling holes, notching for wire etc. for inserting bolts incl all necessary drilling, bolting or riveting etc. complete |
| 162 | M&L for two coats of white wash on previously untreated (new)/old surface of RCC posts or bk wall incl preparation of surface complete |
| 163 | M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, oval shape WHB, wall claddings and the likes; in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.. |
| 164 | M&L Mild steel, plain, 1.25 mm thick sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 165 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth for fdn,etc.n. exc 10sqm on plan and getting out in soft/loose soil. |
| 166 | M&L for PCC 1:3:6 type C-2 (using 40 mm grade stone agg) as in foundation filling and mass concrete complete all as specified and directed. |
| 167 | M&L RCC M-30 in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete. |
| 168 | M&L RCC M-30 in Columns, pillars, piers, posts and struts etc; |
| 169 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surface . |
| 170 | Formwork to sides of pillars, posts, struts, piers, columns, and stanchions and similar work; for fair finished surface . |
| 171 | M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of primer etc complete all as specified and directed. |
| 172 | M&L for preparation of new steel or iron surfaces Surfaces over 10cm in width or girth and applying two coats of synthatic enamel paint over a coat of red oxide zinc chrome primer . |
| 173 | Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 174 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface of wall and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 175 | Supply only integral water proofing compound all as specified and directed. |
| 176 | Preparation of Newly Plastered surfaces and applying two coat of Cement Base Paint on walls all as specified and directed by Engineer-in-Charge. |
| 177 | M&L for Preparation of old surfaces of Wall and applying one coat of Cement Base Paint on walls all as specified and directed by Engineer-in-Charge. |
| 178 | M&L providing precast cement concrete louvers and jallies, 50 mm thick (measured solid) of type B0 1:2:4 (12.5 mm graded aggregate) set in cement mortar 1:4 including all mouldings but excluding frame complete all as specified and directed by Engineer-in-Charge. |
| 179 | S&F 18 Gauge stainless steel (SS Grade- 304) Railing on stair case having 2\\" Top Horizontal main rail, 3x20 mm dia horizontal sub rail, 900 mm height 1.5\\" Vertical Support left every two steps complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender