Tender For Special Repairs (B/R) Of Watch Towers At Nad Karwar.
Tender Value
41 Lakhs
Estimated cost
Bid Submission
15 Oct 2026
12 days left
EMD
82000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Uttara Kannada → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs (B/R) Of Watch Towers At Nad Karwar.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling/ Taking out existing hessian-based felt or any other existing waterproofing treatment from roof, including cement plaster and exposing the top surface of RCC slab, including removing the dismantled debris to a distance exceeding 200 m and not exceeding 250 m, complete all as specified and directed. |
| 2 | Surface preparation: - Preparing the concrete surface to remove dust, dirt, laitance, etc., using mechanical means and treating minor defects in concrete with polymer-modified mortar using SmartCare Repair Polymer (SBR). |
| 3 | Application: Providing and Installing SmartCare TPO Membrane Reinforced Membrane or Equivalent is a high performance, heat weldable, scrim reinforced thermoplastic polyolefin (TPO) sheet manufactured & supplied in thickness of 1.5mm as per UNI EN 1849-2, designed for waterproofing and heat shielding roofs of new and existing buildings. The membrane shall have elongation at break >15% as per UNI EN 12311-2 , Hydrostatic Pressure Resistance (6 hrs @5 bar) as per UNI EN 1928 met B ,Tearing Strength (N) >300 as per UNI EN 12310-2, Puncture resistance (mm) of >700 as per DIN 16726-5.12 , Tensile Strength (N/5 cm) is >1100 as per UNI EN 12311-2, the joint of membrane should welded with double seam welding machine and detailing of membrane can be done through hand applied welding tools. The membrane shall be terminated at min height of 300mm above FFL in the vertical areas using termination bar and mechanical fasteners and PU sealant, complete as per manufacturer specifications and product data sheets. |
| 4 | Demolition of cement concrete in any position and paving's not exceeding 15 cm thickness (below or above ground level). |
| 5 | M&L for plain cement concrete (1:2:4) type B2 using 40 mm graded stone aggregates in surface channels and drains, all as specified and directed. |
| 6 | Extra for forming fair-finished drains or channels of 30 cm inner girth in cement concrete using extra cement, including forms, moulds, mitred/stopped ends, etc., complete and as directed. |
| 7 | M&L for 75 mm thick PCC (1:3:6), type C2 using 20 mm graded stone aggregate as in hardstanding/plinth protection, and finished the concrete surface even and smooth without using extra cement, complete as specified and directed. |
| 8 | M&L PCC (1:4:8) type D2 using 40 mm graded stone aggregate, 100 mm thick as in sub-base for floors, hardstanding's, etc., complete as specified and directed. |
| 9 | M&L for sand filling under floors, including watering and consolidation. |
| 10 | M&L for machine-pressed precast concrete interlocking paver blocks of any shape and size conforming to IS 15658:2006, 60 mm thick, M35 grade, using grey cement and pigment. |
| 11 | M&L for providing cement concrete (1:2:4), Type B1 using 20 mm graded stone aggregate, as in kerbs or mud stops. |
| 12 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons, etc., laid, bedded, and pointed in any mortar. |
| 13 | M&L for machine-cut Kota stone slabs 20–25 mm thick in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and mirror polishing over and including 20 mm thick screed bed or bedding layer in cement mortar (1:4) for laying floor finishes, complete all as specified and directed. |
| 14 | M&L for machine-cut Kota stone slabs 20 mm thick in risers of steps, skirting, dado, and pillars, laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and mirror polishing over and including 10 mm thick plastering on fair faces of brickwork or concrete surfaces in cement mortar (1:3) to receive wall finishes, complete all as specified and directed. |
| 15 | Demolition of precast concrete block walling, brickwork, or stone/boulder masonry built in cement mortar, including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework, and precast concrete articles, complete all as specified and directed. |
| 16 | M&L for providing precast cement concrete block masonry with solid blocks exceeding 10 cm in width, Type C-1 (1:2:4) using 20 mm graded stone aggregate, set in cement mortar (1:6), complete all as specified and directed. |
| 17 | Taking down cement plaster from wall surfaces of any description, including raking out joints, hacking for key, scrubbing down with water, etc. |
| 18 | M&L for rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4), mixed with waterproofing compound as per manufacturer's instruction, complete all as specified and directed. |
| 19 | M&L for rendering 10 mm thick in cement mortar (1:6) on fair faces of concrete surfaces, complete all as specified and directed. |
| 20 | M&L for rendering 5 mm thick in cement mortar (1:3) on fair faces of concrete surfaces, complete all as specified and directed. |
| 21 | M&L for preparing newly plastered wall surfaces, including priming plastered and other surfaces with alkali-resistant priming paint and applying two coats of oil-bound distemper using mechanical spray (maximum working pressure of 3300 PSI) over a coat of primer, including 3 mm thick wall care putty and finishing the surface, complete all as specified and directed. |
| 22 | M&L for preparing newly plastered surfaces of ceiling, including priming plastered and other surfaces with alkali-resistant priming paint and applying two coats of oil-bound distemper using mechanical spray (maximum working pressure of 3300 PSI) over a coat of primer, including finishing the surface, complete all as specified and directed. |
| 23 | M&L for applying two coats of exterior weatherproof emulsion paint using mechanical spray (maximum working pressure of 3300 PSI) over a coat of primer, including preparation of new plastered wall surfaces, complete all as specified and directed. |
| 24 | M&L for preparation of old plastered/decorated ceiling surfaces, including washing, rubbing down, and stopping of distempered and painted surface spots, and applying two coats of oil-bound distemper using mechanical spray (maximum working pressure of 3300 PSI), including necessary scaffolding and safety measures, complete all as specified and as directed by the Engineer-in-Charge. |
| 25 | M&L for preparation of old plastered/decorated wall surfaces, by washing, rubbing down, and stopping of distempered and painted surface spots, and by mechanical sprayer applying two coats of oil-bound distemper, including necessary scaffolding and safety measures, complete all as specified and as directed by the Engineer-in-Charge. |
| 26 | M&L for preparing old painted plastered surfaces of walls/ceilings/chajjas of any description, including brooming down or steel wire brushing, scraping down smoke, soot, moulds, moss, and efflorescent salts, and treating oil and greasy spots, and by mechanical sprayer applying one coat of exterior grade acrylic emulsion weatherproof paint, including necessary scaffolding and safety measures, complete all as specified and directed. |
| 27 | M&L for preparing old painted plastered surfaces of walls/ceilings/chajjas of any description, including washing, rubbing down and stopping of distempered and painted surface spots, etc., and applying two coats of acrylic emulsion exterior grade weatherproof paint by mechanical sprayer, including necessary scaffolding up to 35 m height and safety measures as required, complete all as specified and directed. |
| 28 | Supply only integral waterproofing compound. |
| 29 | Dismantling of floor, hearth or wall tiling, including cement mortar bedding. |
| 30 | M&L for non-skid, joint-free coloured ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry over and including 15 mm thick screed bed or bedding layer of cement mortar 1:4 for laying floor finishes, complete all as specified and directed. |
| 31 | All as per Item No. 30 above, but here in skirting/dado, etc., set and jointed in neat cement slurry over and including 10 mm thick rendering in cement mortar 1:3 on fair faces of brickwork or concrete surfaces to receive wall finishes. |
| 32 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular), area of each tile exc 0.06 Sqm but n.exc 0.11 sqm as in floors etc laid over and including 15mm thick screed bed in CM 1:4 and set and jointed in neat grey cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 33 | M&L for glazed ceramic coloured tiles in vertical surfaces (350 × 250 × 7 mm / 450 × 350 × 7 mm thick), set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including plastering 10 mm thick on fair faces of brickwork or concrete surfaces in cement mortar 1:4 to receive wall finishes. |
| 34 | Taking down chowkats or frames exceeding 1.5 sqm but not exceeding 4 sqm each, with shutters (without taking off shutters from the frame), including making good disturbed portions to match adjoining surfaces, complete all as specified and directed. |
| 35 | Taking down shutters of any description exceeding 1 sqm but not exceeding 2 sqm each. |
| 36 | S&F aluminium powder-coated frames (minimum powder coating thickness 50 microns) for doors, windows and ventilators, with one or more rebates, including joining cleats for fixing, complete in repairs all as specified and directed. |
| 37 | S&F in repairs aluminium powder-coated door shutters (minimum powder coating thickness 50 microns), aluminium sections weighing not less than 0.55 kg/m, including necessary joining cleats, glazing clips, rubber/neoprene packing, 2 Nos. handles to each door, hinges, anodised aluminium snap beading, screws, etc., complete all as specified and directed. |
| 38 | S&F aluminium powder-coated window/ventilator shutters (minimum powder coating thickness 50 microns), sliding type without sash bars, aluminium sections weighing not less than 0.55 kg/m, including necessary joining cleats, glazing clips, rubber/neoprene packing, aluminium snap beading, screws, etc., complete in repairs all as specified and directed. |
| 39 | S&F 18/19 mm thick prelaminated particle board, interior grade, prelaminated on both sides with decorative lamination, fixed with screws to timber frame as in cupboards, shutters, shelves, pelmets, etc., including fixing 18 mm wide and 6 mm thick beading of first-class hardwood (teak) all around, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 40 | M&L for 5 mm thick figured glass, pin-head type, and glazing with wooden beading, exceeding 0.5 sqm in each pane, complete all as specified and directed. |
| 41 | S&F stainless steel wire cloth, 0.36 mm nominal diameter of wire and average width of aperture 1.40 mm, fixed with stainless steel wire staples, complete in repairs all as specified and directed. |
| 42 | S&F aluminium body door closer, hydraulically regulated, designation No. 3, universal type, suitable for door shutters 851 mm to 1000 mm in width and weighing between 61 to 80 kg, complete in repairs all as specified and directed. |
| 43 | Dismantling timber scantlings 40 sq cm and over in section, unframed work in any position. |
| 44 | M&L for plain solid straight chowkats and frames of second-class hardwood, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue and pinned at joints, complete all as specified and directed.. |
| 45 | M&L for second-class hardwood 40 mm thick framed panelled door shutters (any number of panels), with panels of timber flat on both sides or veneered particle board/medium density fibreboard with commercial face veneers, fitted to chowkats, complete all as specified and directed. |
| 46 | M&L for solid PVC door frames of size 50 mm × 47 mm, made out of 5 mm thick plain coloured PVC sheet, reinforced with MS square tube, as per specification and drawings. |
| 47 | S&F factory-made solid panel PVC door shutter, 30 mm thick (styled), consisting of MS tube frame for top and bottom rails, covered with heat-moulded wood grain printed PVC “C” channel; 5 mm thick × 15 mm wide PVC sheet beading used inside stiles and rails; wood grain printed PVC sheets for top rail, lock rail and bottom rail on both sides; panel infill of printed PVC sheet fitted in MS frame, welded/sealed to stiles and rails with decorative PVC beading 10 mm × 10 mm (90°), jointed with solvent cement, complete all as specified and directed. |
| 48 | S&F 150 mm long aluminium anodized handle of extruded section, complete all as specified and directed. |
| 49 | S&F 100 mm medium weight mild steel butt hinges to frames, complete in repairs all as specified and directed. |
| 50 | S&F 150 mm long aluminium anodized barrel tower bolts of extruded sections, complete in repairs all as specified and directed. |
| 51 | S&F 300 mm long aluminium alloy anodized sliding door bolts with hasp and staple (bolt type), including fixing clips of extruded sections and fixing bolts, complete in repairs all as specified and directed. |
| 52 | S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 × 440 mm, white, with integral footrests, complete (excluding fixing bolts, flushing cistern and flush pipe), including provision of lime concrete bedding, complete all as specified and directed. |
| 53 | S&F vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), complete in repairs all as specified and directed. |
| 54 | M&L for PVC valveless syphonic action type flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle, including brackets and 32 mm dia flush pipe, fixed in repairs, complete all as specified and directed. |
| 55 | S&F CP health faucet with flexible spring pipe, complete in repairs all as specified and directed |
| 56 | S&F PVC connections 15 mm size with PTMT nuts, 600 mm long. |
| 57 | S&F in repairs vitreous China wash basin, white, flat back, size 550 × 400 mm, including brackets and cutting for and pinning ends of brackets or erecting stand, including 32 mm pillar tap of cast copper alloy, chromium plated fancy type with capstan heads, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’, with long screwed shanks and fly nuts, suitable for 15 mm pipe connections, including waste pipe, complete all as specified and directed. |
| 58 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings such as heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store, measured overall along centre line over fittings and accessories. |
| 59 | M&L for PVC (SWR) pipe, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110 mm bore, complete all as specified and directed. |
| 60 | M&L for PVC (SWR) pipe, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 75 mm bore, complete all as specified and directed. |
| 61 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for pipelines, etc., in hard/dense soil, complete all as specified and directed. |
| 62 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard/dense soil. |
| 63 | Removing surplus excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point. |
| 64 | Demolition and breaking up drain pipes 100 mm dia (salt glazed stoneware or reinforced concrete) set in cement mortar, including PCC bed and haunching, and removal of debris outside MD land, complete all as specified and directed. |
| 65 | M&L for PCC 1:3:6 Type C-2 (using 40 mm graded stone aggregate) as bed to 100 mm bore drain pipes, including packing under and haunching against sides of pipes after laying and testing, complete all as specified and directed. |
| 66 | M&L for double wall corrugated (DWC) pipes 150 mm dia, manufactured from HDPE, UV resistant, lightweight and durable, suitable for sewerage and water purposes, complete all as specified and directed. |
| 67 | M&L for WC connector 110 mm dia PVC (SWR). |
| 68 | S&F 110 mm dia PVC (SWR) junction, single ‘T’ (equal or unequal). |
| 69 | S&F 110 mm dia PVC (SWR) reducer. |
| 70 | S&F 110 mm dia PVC (SWR) bends with access door of required radius. |
| 71 | S&F 75 mm dia PVC (SWR) bends with access door of required radius. |
| 72 | M&L for PVC (SWR) floor trap, plain with grating, including jointing with solvent cement, 75 mm dia outlet complete in repairs, all as specified and as directed. |
| 73 | S&F PVC connection, 450 mm long × 15 mm bore, screwed at both ends for iron pipe or unions, in repairs. |
| 74 | M&L for mirror 600 × 450 mm, bevelled edge, 5 mm thick selected quality glass, mounted on 6 mm thick AC building board, fixed to wall with wooden plugs, chromium plated brass screws and cup washers, complete in repairs all as specified and directed. |
| 75 | S&F brass chromium plated towel rail, 20 mm dia, D-type, 600 mm long between flanges, fixed in repairs, complete all as specified and directed. |
| 76 | S&F fancy type bib tap, brass chromium plated, long shank, 15 mm bore with capstan heads, screwed down for iron pipes, complete in repairs all as specified and as directed. |
| 77 | S&F fancy type chromium plated stop valve, 15 mm bore with long shank and concealed cup, screwed down high pressure, with crutch or butterfly handle, screwed at both ends for iron pipe or unions complete in repairs, all as specified and as directed. |
| 78 | S&F in repairs fancy type angle cock, brass chromium plated, long shank, 15 mm bore, screwed down high pressure, with crutch or butterfly handle, screwed at both ends for iron pipe or unions, complete all as specified and directed. |
| 79 | Taking up or down GI tubing and connections, 15 mm bore, including cleaning or removal to store, complete all as specified and directed. |
| 80 | Taking up or down GI tubing and connections, 20 mm bore, including cleaning or removal to store, complete all as specified and directed. |
| 81 | Taking up or down GI tubing and connections, 25 mm bore, including cleaning or removal to store, complete all as specified and directed. |
| 82 | Taking up or down GI tubing and connections, 32 mm bore, including cleaning or removal to store, complete all as specified and directed. |
| 83 | S&F 15 mm dia UPVC pipes of pressure rating 10 kg/cm² fixed to walls, ceilings or in floors, including jointing cleats, elbows, etc., complete all as specified and directed. |
| 84 | S&F 20 mm dia UPVC pipes of pressure rating 10 kg/cm² fixed to walls, ceilings or in floors, including jointing cleats, elbows, etc., complete all as specified and directed. |
| 85 | S&F 25 mm dia UPVC pipes of pressure rating 10 kg/cm² fixed to walls, ceilings or in floors, including jointing cleats, elbows, etc., complete all as specified and directed. |
| 86 | S&F 32 mm dia UPVC pipes of pressure rating 10 kg/cm² fixed to walls, ceilings or in floors, including jointing cleats, elbows, etc., complete all as specified and directed. |
| 87 | Dismantling PVC/RCC water storage tank of capacity exceeding 1000 litres but not exceeding 2000 litres, including removal from site, complete all as specified and directed. |
| 88 | Dismantling water tank of 500 litres capacity of any description and removing from site, complete all as specified and directed. |
| 89 | S&F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) of 1000 litres capacity, hoisted and fixed in position, complete all as specified and directed. |
| 90 | S&F rotational moulded polyethylene water storage tank, double layered, capacity 500 litres (cylindrical vertical with closed top), ISI marked, hoisted and fixed in position, complete all as specified and directed. |
| 91 | S&F 20 mm dia ball valve, high pressure PTMT with epoxy coated aluminium rod and high-density plastic ball, screwed for iron pipe, fixed in repairs (minimum weight 20 mm – 210 gms), complete in repairs all as specified and directed. |
| 92 | S&F 20 mm gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe or unions, complete in repairs all as specified and directed. |
| 93 | S&F 15 mm gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe or unions, complete in repairs all as specified and directed. |
| 94 | Demolition of RCC of any description and in any position not otherwise specified, including removal of debris outside MD land, complete all as specified and directed. |
| 95 | M&L for precast reinforced cement concrete 1:2:4, Type B1 (using 20 mm graded stone aggregate) as in cover slabs (for manholes, etc.), shelves and similar articles with plain faces, set in cement mortar 1:6, including necessary formwork, complete all as specified and directed. |
| 96 | S&F onsite LLDPE septic tank designed for sewage and sullage water, including excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connections, etc., complete for 10 users. |
| 97 | M&L for soakage well, including excavation in any type of soil, foundation in PCC 1:3:6, honeycomb brick masonry walls, RCC top ring of M25 grade concrete, intercepting and screen chambers in brick masonry in CM, RCC cover slab in M25/SFRC, intercepting pipes of RCC/DWC, filled with brick bats, size 1.2 m dia × 3 m deep, complete all as shown in CE (Navy) Mumbai TD drawing number- TD/ 94007 dated 26 Nov 1994 Revised dated 10 Apr 2014 all as specified and directed. |
| 98 | M&L for TMT steel reinforcement bars 10 mm dia and above, cut to length, bent to shape, including cranking and binding, complete all as specified and directed. |
| 99 | All as per Item No. 98 above but 6 mm to 8 mm dia as in stirrups, complete all as specified and directed. |
| 100 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 101 | S&F mild steel plates Fe 410-W (Grade E250), quality-A, plain or chequered, 5 mm thick or above, in available sizes, complete all as specified and directed. |
| 102 | M&L for rolled mild steel sections for roof trusses, framed structures, purlins, crane gantries, rails, fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections), including plates, drilling, bolting, riveting, welding, cleats, etc., conforming to Fe 410-W (Grade E250), quality-A, complete all as specified and directed. |
| 103 | S&F framed work such as grills, gratings, sunshades, guard bars, ladders, railings, and similar works, conforming to Fe 290 or Fe 165, including welding, riveting or forging, complete all as specified and directed. |
| 104 | M&L for preparation of old painted steel surfaces of any description not otherwise described over 10 cm width or girth, and applying two coats of synthetic enamel paint using mechanical spray (maximum working pressure of 3300 PSI) including scaffolding and safety measures, complete all as specified and directed. |
| 105 | M&L for preparation of new steel surfaces of any description, over 10 cm width or girth not otherwise described, applying two coats of synthetic enamel paint and applying two coats of synthetic enamel paint using mechanical spray (maximum working pressure of 3300 PSI) over one coat of red oxide/zinc chromate primer by mechanical sprayer, complete all as specified and directed. |
| 106 | M&L for preparation of new wooden and wood-based surfaces over 10 cm width or girth, applying two coats of synthetic enamel paint using mechanical spray (maximum working pressure of 3300 PSI) over one coat of pink primer complete all as specified and directed. |
| 107 | Taking down aluminium/copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, etc., and removing materials to store for keeping in safe custody or for taking credit (credit for above items shall be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed. |
| 108 | M&L for point wiring for one light point controlled by one switch with 1100 V grade, 1.5 sqmm PVC insulated FRLSH unsheathed cable with multi-stranded copper conductor conforming to IS:694:1990 with ISI marking, drawn through PVC conduit (surface/recessed), including all accessories in wall/ceiling/floor/roof etc and sunk pressed steel or cast iron terminal boxes with 3 mm thick plastic laminated sheet top cover, and including 1.5 sqmm PVC insulated FRLS unsheathed 1100 V multi-stranded copper conductor as continuous earth wire connected to common earth dolly, complete all as specified and directed. |
| 109 | M&L for point wiring for one fan/exhaust fan point controlled by one switch and regulator, complete with 1100 V grade, 1.5 sqmm PVC insulated FRLSH unsheathed cable with multi-stranded copper conductor conforming to IS:694:1990 drawn through PVC conduit (surface/recessed), including all accessories in wall/ceiling/floor/roof etc., and sunk pressed steel or cast iron terminal boxes with 3 mm thick plastic laminated sheet top cover; including 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multi-stranded copper conductor as continuous earth wire connected to common earth dolly, all as specified and directed |
| 110 | M&L for point wiring one 5 pin 5 Amps socket point controlled by one switch on same board & regulator complete with 1100 Volts grade, 1.5 Sqmm PVC insulated FRLSH unsheathed cable with multi-stranded copper conductor conforming to IS:694:1990 with ISI marking, drawn through PVC conduit surface/recessed, including all accessories in wall/ceiling/floor/roof etc., and sunk pressed steel or cast iron terminal boxes with 3 mm thick plastic laminated sheet top cover; including 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multi-stranded copper conductor as continuous earth wire connected to common earth dolly, all as specified and directed |
| 111 | M&L for point wiring one 5 pin 5 Amps socket point controlled by one switch on independent board & regulator complete with 1100 Volts grade, 1.5 Sqmm PVC insulated FRLSH unsheathed cable with multi-stranded copper conductor conforming to IS:694:1990 with ISI marking, drawn through PVC conduit surface/recessed, including all accessories in wall/ceiling/floor/roof etc., and sunk pressed steel or cast iron terminal boxes with 3 mm thick plastic laminated sheet top cover; including 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multi-stranded copper conductor as continuous earth wire connected to common earth dolly, all as specified and directed |
| 112 | All as per item No 111 above but with 4 Sqmm copper conductor including 4 Sqmm copper cable as earth wire for one 6 Pin 16 Amps Socket outlet on independent board complete all as specified and as directed by Engineer-in-Charge. |
| 113 | S&F Switch piano type 5 Amp single pole one way complete in repair all as specified and directed by Engineer-in-Charge. |
| 114 | S&F Switch piano type 15 Amp single pole one way complete in repair all as specified and directed by Engineer-in-Charge. |
| 115 | S&F Socket outlet 2 in 1, 3 pin, 6 and 16amp flush type complete in repair all as specified and directed by Engineer-in-Charge. |
| 116 | S&F Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and as directed by Engineer-in-Charge. |
| 117 | S&F Inverter LED 20W light, white colour temperature 6500K along with 4ft batten consisting of a Lithium Ion battery with charging time 8-10 hours and back up time upto 4 hours complete with all connected accessories including connecting up with twin core twisted flexible copper conductor cable of suitable size complete in repair all as specified and directed. |
| 118 | S&F building security light fitting LED 45 W new generation energy saving and environmental friendly long life LED street light made up of pressure dia cast aluminium housing with high power LED as lighting source and lens emended pc cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 including GI bracket for wall mounting all as directed by Engr -in -charge . Make cg Cat No. LSTS-45-CDL-M or equivalent in Bajaj/ Philips/ HAVELLS including taking down old one. |
| 119 | M&L for taking down ceiling fan, removing the old burnt motor, and replacing the conventional motor with a BLDC motor suitable for operation with regulator/remote, including electronic circuit, blades, downrod, canopy, and all necessary connecting items, complete all as directed. |
| 120 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed by Engr-in-charge. |
| 121 | M&L for taking down & repairing of Exhaust fans/Wall mounted fans of any make and any sweep dismantling its parts cleaning properly, rewinding with super copper enamelled wire suitable gauge, varnishing, oiling and greasing replacing petty items such as split pins, assembling and testing after fixing of fan blades, refixing at site with required plywood and connecting complete. |
| 122 | S&F SP 6 to 32Amps,240V, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed |
| 123 | S&F SPN 40 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning all as specified and directed by Engr in charge. |
| 124 | S&F SPN sheet metal enclosure for DB 4 ways Double door complete all as specified and as directed by Engineer-in-Charge. |
| 125 | Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross-sectional area 16 Sqmm 4 core, conforming to laid in trenches/wall/floors/ducts etc fixed with saddle and clamps or passing through pipes complete with cable and connection with proper thimbles, nuts, bolts andwashers all as specified and directed. |
| 126 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting out in soft/loose soil all as specified and directed. |
| 127 | Returning, filling in soil including spreading levelling, watering and well ramming in layers not exceeding 25cm thick all as specified and directed. |
| 128 | Removing excavated material/soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed. |
| 129 | M&L for DWC pipe of 75 mm dia for electrical ducting laid in trenches and jointed including necessary jointing material, tees/ union/ socket etc complete all as per manufacturer's instructions including taking out old pipe complete all as specified and directed. |
| 130 | S&F LED batten tube light fitting with aluminium housing & integrated housing suitable for fixing on wall & surface of 20 watt capacity & 4 feet complete with all electrical connection all as specified and directed. |
| 131 | S&F lamp holder, PVC /poly carbonate type with back plate suitable for batten fittings complete in repair, all as specified and as directed by Engineer-in-Charge. |
| 132 | M&L for taking down of aluminium earth strip of any size and Al Air termination Rod kept aside for schedule of credit. |
| 133 | M&L for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed |
| 134 | S&F air termination, single pointed Aluminium rod 12 mm dia and 300 mm long complete in repair, all as specified and as directed. |
| 135 | S&F of test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw and protected with 3mm thick enclosure completed closed for test point with 4 nos of screws with wall complete in repair, all as specified and directed. |
| 136 | S&F red epoxy insulator suitable for fixing earthing strip to the wall / floor etc complete with necessary nuts, bolts and fixing material complete in repair all as specified and as directed. |
| 137 | M&L in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed |
| 138 | M&L in replacement of Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil.(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed(d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.(e) Requisite quantity of common salt and charcoal.(f) Testing of earthing. |
| 139 | S&F indoor loop box of size 200x200x100mm made of 2mm thick CRCA sheet steel with powder coated finish, complete with terminal blocks, earth terminal, conduit entries, fixing accessories and all connections, complete all as specified and directed by Engr in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysOct 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender