Tender For Addition / Alteration To Concertina Coil And Barbed Wire From Mes Block 2 To Mulla Auditorium At Navy Nagar, Colaba, Mumbai
Tender Overview
Project Description
Tender for Addition / Alteration To Concertina Coil And Barbed Wire From Mes Block 2 To Mulla Auditorium At Navy Nagar, Colaba, Mumbai
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 22-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement or cement lime plaster on brick or stone walls, any description, including raking out joints, hacking for key, scrubbing down with water, etc including disposal of debris out side the MoD land etc complete as directed by Engr-in-charge. |
| 2 | Providing and plastering '15mm average thickness with premixed readymade cement mortor of approved brand / make,manufactured in automated dry mix batching plant where cement ,sand and polymer additive are mixed in pre-determined ratio(as per manufacturer specification ). In one coat. 6 to 7 liter portable water (as per manufacturer specification )shall be added to 40 kg of readymix dry mortor mixing G.I tray and shall be mixed well for 4-5 minutes.The mortor shall be left undisturbed for 3-5 minutes to dissolve additive and shall be mixed once again to form cohesive and consistent mix\\" |
| 3 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles including disposal of debris out side the MoD land etc complete as directed by Engr-in-charge. |
| 4 | Material & Labour Brick work with sub class 'B' brick straight or curved on plan exc 6 mtr mean raddius built in CM (1:6) complete all as specified and directed by Engg-In- Charge. |
| 5 | Demolition of cement concrete un-reinforced of any description and at any position including disposal of debris out side the MoD land etc complete as directed by Engr-in-charge. |
| 6 | M&L Plain cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in coping/kerbs including necessary form work including weathering slightly rounded or chamfered angles and throating complete all as specified and directed by Engr-in-charge. |
| 7 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engg-In- Charge. |
| 8 | M & L Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 all as specified and directed. |
| 9 | M&L MS plate plain/ Chequered of required thicknes over as in manhole cover fixed to angle iron frame with three No of hinges and 150mm handle. complete all as specified. |
| 10 | Preparaing of old steel surfaces of any description and applying one coat of synthetic enamel paint complete all as specified and as directed by Engg-In- Charge. |
| 11 | Preparaing of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engg-In- Charge. |
| 12 | Material and labour for Prepararing old surfaces plastered or unplastered by Washing, rubbing down and stopping of distempered and painted surfaces of wall. Complete all as specified and directed. |
| 13 | M&L for applyiing two or more coats of 100 % premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004 alkali & fungal resistance ,dirt resistance exterior paint of required shade with silicon additives @1.43 ltr/10 sqm over priming coat of exterior primer applied @0.90ltr/10sqm complete all as specified. |
| 14 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings or chajjas (FRP or any other pattern) complete all as specified and directed |
| 15 | Material & Labour pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engg-In- Charge. |
| 16 | Dismantling of existing concertina coil along with barbed wire and removing outside of MoD |
| 17 | S&F in repair barbed razor type concertina coil 9 SWG hot galvanised spring tensile wire of UTS 145 to 150 Newton per square mm zinc coating 250-300 grams per sqm ,dia of coil when unstretched 600 mm covering 8 to 10 running meter per coil and minimum weight of coil (GI strip) 1.625 kg per running metre hot dip galvanised razor ribbon tape of size 0.50 mm thickness, 19 mm wide before wrapping on central core wire fixed 1.66 mm thick GI clip minimum 25 nos per running metre and special nut bolt to hold two coils together and extra two rows parallel wire of 10 gauge complete all as specified and as directed . |
| 18 | S&F in repair galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails strain-ing bolts, including, tying at crossing with and provision of galvanised mild steel wire, staple or steel pins etc as directed by EIC (each line wire to be measured). |
| 19 | Material & Labour for 75mm thick PCC (1:3:6 ) type C-2 using 40 mm graded stone aggregate as in plinth protection laid in panels and in base course for pavers blocks and coping etc complete all as specified and directed by Engg-In- Charge. |
| 20 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material out of the MoD land as per direction of Engineer-in-Charge. |
| 21 | S&F Machine Pressed precast concrete interlocking paver block of 60 mm thick M-35 Grade of any shape and size confirming to IS -15658-2006 with grey cement and pigment as approved complete all as specified and directed. |
| 22 | M&L for sand filling under floor or in foundation including watering & consolidation complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender