Public Administrative Department Local Bodies Closing in 7 days TDR #57693449

Tender For Provision Of Lighting Arrangement With Led Lights At Nd-44 Pit Ura , Mpl Park Near Uu-56, Mpl Park Near Uu- 32, Mpl Park Near Uu-69, Mpl Park Near Qu-272 ( Near Uttari Pit Ura Metro Station) & Mpl Tikona Park G& Ju In Pit Ura Ward -57 (Ac-

Issued by Local Bodies · Delhi, Delhi
Tender Value
22.27 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
7 days left
EMD
44500
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of Lighting Arrangement With Led Lights At Nd-44 Pit Ura , Mpl Park Near Uu-56, Mpl Park Near Uu- 32, Mpl Park Near Uu-69, Mpl Park Near Qu-272 ( Near Uttari Pit Ura Metro Station) & Mpl Tikona Park G& Ju In Pit Ura Ward -57 (Ac-14 ) Under Kpz

BOQ

Name of Work:- Provision of lighting arrangement with Led Lights at ND-44 Pit ura , MPL Park Near UU-56, MPL Park near UU- 32, MPL Park near UU-69, MPL Park near QU-272 ( near Uttari Pit ura Metro station) & MPL Tikona park G& JU in Pit ura ward -57 (AC-14 ) under KPZ
Sl. No. Item Description
1Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt ) as required.
2Providing and fixing 25 mmX5 mm G.I. Strip on surface or in recess for connection etc. as required
3Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/cable as required.
4Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 Sq mm
5Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Upto 35 Sq mm
6Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
7Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
8Supplying and fixing light class GI Pipe of 50 mm dia (nominal) 3 mtr length alongh the pole for protection of unbder ground cable as required
9Providing and laying of HDPE PIPE of 40 mm outer dia with PN 4 rating by Hand moling/ Manual Method confirming to IS 4984 592
10Supply of XLPE insulated PVC sheathed AL. conductor armoured Cable 1.1 KV grade conforming to IS-7098 of following size- (a) 2X6 Sq mm
11Fabrication , supplying and fixing class B galvanised single overhang arm bracket made out of 250 mm long galvanised top tube with cap and 250 mm long 32 mm dia galvanised pipe with tightening bolts complete as required
12Fabrication , supplying and fixing class B galvanised double overhang arm bracket made out of 250 mm long galvanised top tube with cap and 250 mm long 32 mm dia galvanised pipe with tightening bolts complete as required
13Supply of PVC insulated and FR PVC sheathed multicore copper conductor 1.1. kv grade conforming to IS694 as reqd:-3x1.5 sqmm
14Supplying, Installation, Testing & Commissioning of 40 watt Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angleas per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shallbe of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
15Fabrication, supply & erection of 4.0 mtr height ,3mm thick bottom dia of 130, & top dia of 70 mm base plate of size 225X225X12mm thick size flange mounted hot dip galvanized octagonal pole made from HT steel plate window with flash cover with full vertical window cover at appropriate height form the base plate on existing cement concrete predestal as required i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4mm thick of suitable length and having suitable size tapped holes as reqd. terminal block suitable for 25 sq mm conductor - 4 nos. & shorting links on DIN channel of suitable length ,6 Amp SPMCB 'C' characherstics earth stud cable support clamp suitable for upto 4X25 sq mm cable Logo/Name of manfucturer shall be embossed on the pole Galvanization as per relevant as.
16Providing and laying in position M25 grade reinforced cement concrete foundation of size 450mm(L)X450mm wide and 1000 mm deepi/c excavation of earth providing cutting bending and placing in position reinforcement of cold twisted bars of 12 mm dia- 960mm long (approx) 8 nos. and reinforcement of cold twisted bars of 12 mm dia - 960 mm long (approx) -8 nos and reinforcement of cold twisted bars of 8 mm dia -1400 mm ( approx) -6 nos.(with 150 mm spacing ) as required with supplying and position of 4 nos. foundation DCW HDPE for cable entry and exit as required for 3 m to 5m pole.
17Fabrication, Supplying, Installation, testing, Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside & out sides & suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For High Mast head frame, 2 point suspension system with steel wire rope 5mm dia. (7/19 construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically and its control gears boxes and lighting finial, the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering the safe soil bearing capacity at site as 10T/sqm at 2mts. depth with all material i/c 4Nos S.P MCB, 63Amp. DP Isolator etc as reqd. Logo/Name of Manufacturer shall be embossed on the pole. Galvanization as per relevant IS.
18Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd.
19Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
20Providing and fixing of Stainless steel name plate of size 6×8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required
21P/F Name board made of MS Sheet 90X60 Cm, 1 mm thick with frame of MS angle 50X50X6 mm , two diagonal braces at the back of sheet of Ms Flat 40X6 mm total height of the bpard above ground level 2.40 M Length of Leg Below ground 0.30 M embeded in CC Block 1:2:4( 1 cement , 2 Coarse Sand , 4 Graded stone aggregate 40 mm nominal size)30X30X45 cm including excavation and removal of surplus earth with in 50 m lead applying priming coat of approved steel primer painting with synthetic enamel paint of approved quality and lattering with enamel paint of approved colour ( one side as per drawing/ direction of engineer in charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57693449
AUTHORITY Local Bodies
TENDER VALUE 22.27 Lakhs
LAST DATE 03-10-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Provision Of Lighting Arrangement With Led Lights At Nd-44 Pit Ura , Mpl Park Near Uu-56, Mpl Park Near Uu- 32, Mpl Park Near Uu-69, Mpl Park Near Qu-272 ( Near Uttari Pit Ura Metro Station) & Mpl Tikona Park G& Ju In Pit Ura Ward -57 (Ac-14 ) Under Kpz
Basic Detail
Tender No TC/ENGG./EEE/KPZ/2026-27/22.1
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 24 Sep 2026
Submission Date 03 Oct 2026
Open Date 05 Oct 2026
Finance
Tender Value 22.27 Lakhs
Tender Fee 590
EMD 44500
Exemption Not Available
Document List
BOQ_340642.xls
e6c8c2b0-3d53-4351-8f11-0cc5c1eb0ab3.html
MCD_GCC_2026Latestcirculars.pdf
Tendernotice_1.pdf
Tender_Condition.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Oct 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_340642.xls

html

e6c8c2b0-3d53-4351-8f11-0cc5c1eb0ab3.html

pdf

MCD_GCC_2026Latestcirculars.pdf

pdf

Tendernotice_1.pdf

pdf

Tender_Condition.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders