Tender For Installation Of Submersible Pumping Machinery For Replacementat T/W At High Lift Of Amdol W/S Scheme At Murarai -Ii Block Under Bolpur Mechanical Division Phe Dte.
Tender Value
1.25 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
3 days left
EMD
3000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Birbhum → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Installation Of Submersible Pumping Machinery For Replacementat T/W At High Lift Of Amdol W/S Scheme At Murarai -Ii Block Under Bolpur Mechanical Division Phe Dte.
BOQ
| Sl. No. | Item Description |
| 1 | Withdrawing of 7.5 HP Submersible Pumping Mchinery along with all Column pipe from defunk t/w by own arrangement including disconnection of Power line & delivery line. |
| 2 | Carrying charges damged withdraw 7.5 HP Submersible pumping machinery from withdrawn Pump house site to nearest electric workshop up-down including loading & un-loading complete. |
| 3 | Dismantling of above defective pump-motor set par by part as per EI rules. |
| 4 | Supply of following spares for 7.5 H.P pump. |
| 5 | Shaft sleeve (SS) |
| 6 | Bush (GM) |
| 7 | Neck Ring (GM) |
| 8 | Reassemble the pump with newly supplied materials in item no 4(4.01 to 4.03) and old serviceable spares as per direction of EIC. |
| 9 | Supply and delivery of following motor spares as per sample : (Approved make) |
| 10 | Motor Bush(GM) for upper & lower- 2 Nos.in set. |
| 11 | Re-winding charges of 7.5 HP Submersible Motor by the suitable gauges P.V.C. insulated water proof copper cable (Make-Finolex/ Polycab) with maintaining proper no of turn as per direction of E.I.C. ( deduction the cost of burnout copper winding and damaged materials) |
| 12 | Reassembling the above motor part as IE rules. |
| 13 | Supply and delivery of the following valves, pipes and gauges etc at site |
| 14 | 80mm dia. CI Top & Bottom adopter. |
| 15 | Heavy type suitable dia. MS suspension clamp along with nuts bolts and washers. |
| 16 | 80mm dia. CIDF Non-Raising Sluice Valves, PN 1.0 rating (Conforming to IS:14846) for delivery pipe line and wash out line.(MOC & TC needed for valve). |
| 17 | 80mm dia. CIDF single door swing Non Return Valve, PN 1.0 rating (Conforming to IS:5312).(MOC & TC needed for valve). |
| 18 | CIDF 90°bend- 1no., CI flanged tee- 1no., blank flange-1no., CI/MS flanged short piece 0.50 mtr.-1no, CI/ MS flanged pipe 1mtr.- 1 no. etc (as per IS specification and certification registered) for construction of delivery pipe line and wash out line. |
| 19 | Heavy type 250mm dia./suitable Split type tube well cover with clamping arrangement including supply of nuts, bolts and washer as per departmental design. |
| 20 | Anti snapping safety device for pump set by supplying suitable size of MS angle busket and nylon rope of required length including supplying of nuts, bolts and all other materials |
| 21 | 150mm dial Pressure gauge [Range 0-7kg/cm²] with glycerine filling inside the dial including brass cock and fitting complete [This cost includes 15mm. dia G.I. pipes and specials]. |
| 22 | Making brick pillar 0.25 x 0.25 x 0.75 Mtr/Suitable hight for supporting of valves and pipes with 12mm thick plaster and net cement finish complete. |
| 23 | Supply and delivery of 1.1KV grade 4 sq.mm x 3 core water proof flat submersible cable for above pump-motor set. |
| 24 | Supply and delivery of 3mtr long 80mm dia UPVC standard type column pipe [cream color] with both side threaded and one end side socketed with registered KPMG. |
| 25 | Supply & Making necessary PVC Medium pipe (dia of pipe not less than 32mm) protection for submersible cable from kiox box to submersible pump-motor set |
| 26 | Supply and delivery of 1.1KV grade 10 sq.mm 3 core XLPE insulated Aluminium armoured cable conforming to IS 7098 (Part-I) 1988, with upto date amendments. |
| 27 | Laying of one No. cable 16 sqmm 3 core ( Departmental supply) in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of thecable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. |
| 28 | Making CC foundation for support of the kiosk box after excavating the earth upto a depth of 0.6 Mtr below the GL including supply of all materials complete with 12 mm thick cement plastering with net cement finishing complete as per direction of EIC (size: 3' x 1' x 5'). |
| 29 | Suitable Kiosk box for cable connection of submersible pump motor set with degree of protection IP 65 including suitable legs and 6 Nos. Al. Bus bar for 32 Amps and all necessary earthing arrangement and insulator as per direction of EIC. |
| 30 | Installation of Submersible pumping machinery to newly sunk tubewell along with column pipes (as required), top cover, valves, and specials of above with protection pipe and supply of MS clamp, nut bolt, cable gland socket etc. making inerconnection of the pump delivery line to pump collecting main line near tubewell with supply of all necceasary pipe, reducer/enlarger, GI/MS specials etc. including brick, sand, cement, rod etc and laying & cable protection pipe as required and all to complete the job including all connection & testing commissioning as per direction of EIC. |
| 31 | Add GST @ 18% |
| 32 | Add Cess @ 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer