Tender For Special Repair To Building No Np-14, Np-21, Np-17 And Np-16 In The Aor Of Age B/R-Ii Under Ge (West) Ferozepur

Issued by Statutory Bodies & Commissions/Committees · Firozepur, Punjab
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Oct 2026
17 days left
EMD
2.24 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Firozepur → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Building No Np-14, Np-21, Np-17 And Np-16 In The Aor Of Age B/R-Ii Under Ge (West) Ferozepur

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 28-Sep-2026 Replacement of Tender Document Other 21-Oct-2026

BOQ

Name of Work:- SPECIAL REPAIR TO BLDG NO NP-14, NP-21, NP-17 AND NP-16 IN THE AOR OF AGE B/R-II UNDER GE (WEST) FEROZEPUR
Sl. No. Item Description
1Demolition of un-reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed.
2Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed.
3Dismantling floor, hearth or wall/stone tiling including cement mortar bedding (but not backing), removing broken tiles and rubbish off the premises from site complete all as specified and directed.
4Demolition of brick work built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed.
5Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc complete all as specified and directed.
6Taking down cement plaster of any description on brick walls or concrete or stone and ceilings including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
7Taking up or down existing 15mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed.
8Taking up or down existing 20mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed.
9Dismantling structural steel work in cluding doors, gates but excluding framed truss etc complete all as specified and directed.
10Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
11Dismantling brick tiles or terracing tiles, single layer on roofs jointed and pointed in cement mortar including removal of grass vegitation including roots near out let of RWP and OHT staging area or specifically ordered in writing complete all as specified and directed.
12Demolition of mud phuska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part hereof ) and removing from site to adistance exceeding 250m but not exceeding 500m complete all as specified. Note :- Demolition of Mud puska to be cut in average thickness from top surface of roof for creating the slope as directed
13Dismantling existing PVC tanks of capacity exceeding 250 Litres but not exceeding 500 litres, removing from site complete all as specified and directed.
14Dismantling existing PVC tanks of capacity exceeding 500 Litres but not exceeding 1000 litres, removing from site complete all as specified and directed.
15Dismantling asbestos cement/fibre (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. Hacking out old broken glass (any size, thickness, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
16Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
17Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size not exceeding 1.5 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts, and removing from site complete all as specified and directed.
18Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size exceeding 1.5 Sqm but not exceeding 4 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts, and removing from site complete all as specified and directed.
19Taking down shutters of any description exceeding 1.00Sqm but not exceeding 2.00Sqm each and removing from site complete all as specified and directed.
20Resecuring or easing and adjusting without taking down dhutters of any description exceeding 1.00Sqm but not exceeding 2.00Sqm each complete all as specified and directed.
21Dismantling boarding, any description, fixed in any postion with nails or screws complete all as specified and directed.
22Excavating in post holes (or similar holes) in soft/loose soil, each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed.
23Surface excavation in soft/ loose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed.
24Excavating in trenches, in soft/loose soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables and pipes etc. not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out complete aii as specified and as direcetd.
25Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceding 25cm in soft/loose soil complete all as directed.
26Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
27M&L for Hardcore of broken stones and boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
28M&L for Lean Cement Concrete (1:2:4) type B-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
29M&L for Lean Cement Concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
30M&L for Lean Cement Concrete (1:3:6) type C-0 using 10mm graded crushed stone aggregate as in filling back sides of pressed steel frames complete all as specified and directed.
31M&L for brick work built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed.
32M&L for brick work (EXCEPT BRICKS) built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. Note:- Old seviceable tiles shall be re-used retrieved after demolition of brick work.
33M&L for Cast-in-Situ Plain Cement Concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate in Cover fillet minimum radius of 75mm as in roof and parapet wall junction, roof benching, kerbs, mud stop, coping, rounded or chamfered on edges, sloping on roof including form work complete all as specified and directed.
34M&L for Cast-in-Situ Plain Cement Concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in bed blocks for hold fasts roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and directed.
35S&F Pressed steel frames made of 1.25mm thick CRCA sheet of profile 105x60mm for door and window frames with one rebate including lock strike plate, shock absorbers, 20mm dia 60mm long MS conduit for housing of a drop bolt, butt hinges, hold fasts/lugs etc and treating of internal surfaces of chowkhats and hold fasts/lugs with a coat of coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified.
36S&F Pressed steel frames made of 1.25mm thick CRCA sheet of profile 125x60mm for door and window frames with one or more rebates incl lock strike plate, shock absorbers, 20mm dia 60mm long MS conduit for housing of a drop bolt, butt hinges, hold fasts/lugs etc and treating of internal surfaces of chowkhats and hold fasts/lugs with a coat of coal tar or black paint incl hinges, hold fasts/lugs etc including making good jambs portion by providing plaster in CM 1:4 and finishes as per existing complete all as specified.
37S&F factory made pressed steel frames made out of 1.25mm CRCA sheet frame of profile 75mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock plate, etc., including one shop coat of priming and 10mm dia round mild steel bar in threshold complete all as specified and directed.
38S&F 35mm thick factory made 2nd class hard wood (Hollock), plain framed, paneled shutters, any number of panels, panels shall be of 12mm thick BWR glade veneered particle board medium density, wood particle board with commercial face veneers, size of members as specified in clause 8.24 (a) of MES Schedule Part-I section-8 complete all as specified and directed.
39S&F 35mm thick factory made 2nd class hard wood (Hollock), glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc for doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, complete all as specified and directed.
40S&F PVC Magnetic Catchers fixed with screws to frame complete all as specified and directed.
41S&F in replacement Factory Made Box Type Steel Windows with glazing bars made of ERW tube hollow \\"P\\" section of size 60mmX25mm double rebated outer frame comprising double shutters side hung skelton & glazed shutters, frame of ERW tube \\"P\\" section size 50mmX20mm with two openable leaf for each shutter consisting two Nos sash bar of T-section 20mmX3mm welded to frame with one vertical mullion of ERW box type T-section of size 60mmX25mm and mild steel flat iron 2mm thick welded/ screwed to frame for fixing of wire gauge to frame/ shutters as given below and all as shown on Drawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No. 1/3 to 3/3 including taking down of old existing window complete all as specified and directed :- (i) Hold fast,150mm long of flat iron 12mmX3mm- 04Nos per window (ii) Handle of Z section 20mmX25mm,100mm long-01Nos per leaf (iii) MS Tower bolt 150mm long-02 Nos per leaf (iv) Z section 20mmX25mm,100mm long stopper -01 Nos per leaf (v) Cleat 55mm long of hollow square 15mmX12mm -02 Nos per leaf (vi) MS pintol hinges size 75mmx12mm- 2 Nos. per leaf (vii) Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). (viii) Preparation of steel surfaces of windows and grills and guard bars and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. Note: Glass panes and grills & guard bars shall be measured and paid for separately .Area shall be measured flat for one side only for the purpose of measurement and payment .
42S&F in replacement Factory Made Box Type Steel Windows without glazing bars made of ERW tube hollow \\"P\\" section of size 60mmX25mm double rebated outer frame comprising double shutters side hung i.e. guaged shutters, frame of ERW tube \\"P\\" section size 50mmX20mm with two openable leaf for each shutter consisting two Nos sash bar of T-section 20mmX3mm welded to frame with one vertical mullion of ERW box type T-section of size 60mmX25mm and mild steel flat iron 2mm thick welded/ screwed to frame for fixing of wire gauge to frame/ shutters as given below and all as shown on Drawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No. 1/3 to 3/3 including taking down of old existing window complete all as specified and directed :- (i) Hold fast,150mm long of flat iron 12mmX3mm- 04Nos per window (ii) Handle of Z section 20mmX25mm,100mm long-01Nos per leaf (iii) MS Tower bolt 150mm long-02 Nos per leaf (iv) Z section 20mmX25mm,100mm long stopper -01 Nos per leaf (v) Cleat 55mm long of hollow square 15mmX12mm -02 Nos per leaf (vi) MS pintol hinges size 75mmx12mm- 2 Nos. per leaf (vii) Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). (viii) Preparation of steel surfaces of windows and grills and guard bars and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. Note: Wire cloth and grills & guard bars shall be measured and paid for separately .Area shall be measured flat for one side only for the purpose of measurement and payment .
43S&F in replacement Factory Made Box Type Steel Ventilators side / top hung with glazing bars or dovetailed or welded made of ERW tube \\"P\\"-section of size 60mmx25mm outer frame ( single rebated), comprises glazed shutter, frame of ERW tube and mild steel flat iron 2mm thick welded/screwed to frame for fixing of sheet glass including fixture and fittings like as Stopper, Cleat, Pintal hinges, holdfast etc all as shown onDrawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No. 1/3 to 3/3 including taking down of old existing window complete all as specified and directed:- Note : 1. Grills and guard bars, Sheet glass and wiremesh shall be measured and paid separately. 2. Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). 3. Preparation of steel surfaces of ventlators and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. 4. Area shall be measured flat for one side only for the purpose of measurement and payment .
44S&F mild steel framed work with Fe.290.Gde-E-165, such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work complete all as specified and directed.
45S&F 50mmx47mm size solid PVC door frame made out of 5mm plain colour PVC sheet reinforced with MS square tube, complete all as specified shown on drawing and specified and directed.
46S&F factory made 30mm thick (style) solid panel PVC door shutter consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified shown on drawing and specified and directed.
47S&F in repairs 18-20mm thick Medium density fibre board exterior grade solid construction type, fixed in repairs in Kitchen cabinets/ CBs doors shutters/ shelves ( horizontal or vertical of any type) on timber frame work /GI Flats orners with screws /nails complete all as specified and directed.
48S&F 0.90mm thick Decorative laminate type -1, both sides of boards surface finish, (colour and pattern as approved) fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.
49S&F factory made PVC cup boards/ Shelf / Partition of required size consisting of panel of 18mm thick Celuka PVC Ply and for supporting the hold of Shelf/ Partition and shall provided 3 edges in size 18mm x18mm as per required length. The front side of the edge visible in the front of the shelf/ Partition to be edge lipped by 18mm width x 1mm thick PVC sheet using solvent cement etc. complete all as specified and directed.
50S&F 40 mm dia, cupboard knobs fixed with nut , screw and washer of brass, polished complete all as specified and directed.
51S&F 100mm size mild steel butt hinges medium weight rolled cold complete all as specified and directed.
52S&F 125mm size mild steel butt hinges medium weight rolled cold complete all as specified and directed.
53S&F 75mm size butt hinges of extruded aluminium alloy with galvanised steel hing pins, anodised and type C-21 complete all as specified and directed.
54S&F 150mm long aluminium anodised barrel tower bolts of extruded section and fixed with steel screws complete all as specified and directed.
55S&F 200mm long aluminium anodised barrel tower bolts of extruded section and fixed with steel screws complete all as specified and directed.
56S&F 150mm size aluminium door handle, cast type, anodised complete all as specified and directed.
57S&F in repairs 75mm size aluminium door handle, cast type, anodised complete all as specified and directed.
58S&F stainless steel continous (piano) hinges of mild steel bright finish or electro galvanised with flap (when open) 25mm, fixed with steel screw complete all as specified and directed.
59S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
60S&F Floor door stopper with 150mm overall length of cover plate made out of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed,
61S&F 300mm size mild steel helical door spring ordinery rat rail rod pattern spring including roller and roller plate complete all as specified and directed,
62S&F 75mm size hasp and staple aluminium anodised including bolt to hinge plate and fixed with screws complete all as specified and directed.
63S&F 100mm size hasp and staple aluminium anodised including bolt to hinge plate and fixed with screws complete all as specified and directed.
64S&F in repairs Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
65S&F 3.0mm thick, plain sheet glass, ordinary quality and glazing, with oil putty or with wooden beads (supplied alongwith shutters), in squares n.exc 0.50 Sqm in each pane complete all as specified and directed.
66S&F Structural Steel Fe-410- W(Gde E-250) Quality 'B' Rolled sections framed work as in doors or gates or cooler stands of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete and similar work complete all as specified and directed.
67S&F Structural Steel Fe-410- W(Gde E-250) quality 'B' Rolled sections as in Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.tes complete all as specified and directed.
68M&L for 50mm thick Plain Cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints and expansion joints filled with bitumen mixed with sand in ratio (1:1) complete all as specified and directed.
69M&L for 75mm thick Plain Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in sub base of flooring, surface finished even and fair, surface finished rough to receive floor topping or interlocking tiles complete all as specified and directed.
70M&L for 25mm thick Plain Cement Concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in surface finished rough to receive floor topping, surface finished even and fair complete all as specified and directed.
71Supply only 3mm thick and 38mm wide glass dividing strips as in floors complete all as specified. (fixing included in item of floor topping) complete all as specified and directed.
72M&L for Granite (of any type) stone slab/tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over and including 10mm thick cement plaster in back coat in cement mortar (1:4) complete all as specified and directed.
73M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Tiles coloured, premium quality, Joint-free, area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
74M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Coloured Tiles, Joint-free, premium quality, area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in vertical surfaces such as skirtings, dados, risers and steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed.
75M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic white colourTiles, Joint-free, premium quality, area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in vertical surfaces such as skirtings, dados, risers and steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed.
76M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paverblocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
77M&L for 10mm thick rendering cement plaster in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
78M&L for 15mm thick rendering cement plaster in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
79M&L for 15mm thick rendering cement plaster in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
80M&L for 5mm thick rendering cement plaster in cement mortar (1:3) on ceiling surfaces, soffits of chajjas or roof projection and the like, finished even and smooth without using extra cement complete all as specified and directed.
81M&L for 15mm thick rendering cement plaster in cement mortar (1:4) in screed bed or bedding layer and plaster on fair furfaces of brick or concrete work on roof terrace for laying Water Proofing Memeberane surfaces, mixed with water proofing complound as per manufacturer's instructionsfinished even and fair without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately.
82M&L for 10mm thick rendering cement plaster in cement mortar (1:4) in screed bed or bedding layer and plaster on fair furfaces of brick or concrete work on roof terrace for laying Water Proofing Memeberane surfaces, mixed with water proofing complound as per manufacturer's instructionsfinished even and fair without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately.
83Supply only Liquid water proofing compound complete all as specified and directed. (Note:- WPC shall be mixed @ 200ml/50Kg of cement or as specified by the Manufacturer's Instructions, whichever is more.)
84Supply only Integral water proofing compound complete all as specified and directed. ( Note:- WPC shall be mixed @ 3% by weight of cement or as per manufacturer's instructions whichever is more.)
85M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm over a coat of bitumen primer @ 0.30 litre per Sqm including preparation of roof surfaces/ sunken portion and all surfaces of sunken portion complete all as specified and directed.
86M&L for One layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surfaceby forced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions.(ii) A minimum overlap shall be 75mm length wise and 100 mm width wise of polymeric membranes respectively and sealed all overlaps and joints as manufacturer's instructions.
87M&L for preparation of surfaces of platered, brick, concrete, polymeric etc, of any description, over10cm in width or girth,not otherwise describedone and applying two coats of Aluminium red oxide paint over complete all as specified and directed. (Water Proofing Treatment on Roofs)
88M&L for 40mm thick brick tiles laid on mud mortar or mud phuska and joints grouted flush and pointed flush as the work proceeds in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed.
89M&L for 40mm thick brick tiles (EXCEPT TILES) laid on mud mortar or mud phuska and joints grouted flush and pointed flush as the work proceeds in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed. Note:- Old seviceable tiles shall be re-used retrieved after dismantling brick tiles on roofs/terrace.
90M&L for 40mm thick average consolidated thickness mud phuska on flat roof ncluding 25mm thick mud plaster complete all as specified and directed. Note:- Old mud phuska shall not be re-used.
91S&F 0.50mm thick Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified complete all as specified and directed.
92S&F 0.50mm thick Pre- painted galvalume aluminum zinc coating GI based plain steel sheetof an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified
93M&L for preparing new plastered surfaces of walls and distempering with two coats of distemper oil emulsion white or tinted over one coat of cement primer over 1.0mm thick plaster of paris putty to prepare surface even and smooth complete all as directed.
94M&L for complete removal of existing treatment on walls and distempering with two coats of cement base paint over one coat of alkali resistant cement primer complete all as specified and directed.
95M&L for complete removal of existing treatment on walls and distempering with two coats of distemper oil emulsion white or tinted over one coat of cement primer over 1.0mm thick plaster of paris wall care putty to prepare surface even and smooth complete all as directed.
96M&L for preparaion of new surface of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance , dirt resistance exterior paint of required shade (company depot tinted ) with silicon additives @ 1.43 litre/10sqm over and including priming coat of exterior primer applied at 0.9 litre/10sqm over new surfaces complete all as specified and directed. (Note:- unit rates qouted by the contractor shall be deemed to be included for scaffodlings, saftey appliances, insurance of workmen and uniform, helmets etc for working in Buildings upto 12m height. No Jhoola is allowed.)
97M&L for preparing new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primercomplete all as specified and directed.
98M&L for preparing new plastered surfaces of walls and applying three coats of lime white wash complete all as specified and directed.
99M&L for preparing new plastered surfaces of ceiling and applying three coats of lime white wash complete all as specified and directed.
100M&L for preparing old plastered surfaces of ceiling and applying one coat of lime white wash complete all as specified and directed.
101M&L for preparation of new wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
102M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer zinc chromate complete all as specified and directed.
103M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
104M&L for preparation of old wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
105M&L for preparation of old steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
106S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floors complete all as specified and directed. Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.)
107S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floor complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.)
108S&F 75mm dia PVC (SWR) bends any radius complete all as specified and directed.
109S&F 110mm dia PVC (SWR) bends any radius complete all as specified and directed.
110S&F 110mm dia PVC (SWR) Branch piece double (double \\"Y\\") equal or unequal complete all as specified and directed.
111S&F 75mm dia PVC (SWR)Junction single (single or double \\"T\\") equal or unequal complete all as specified and directed.
112S&F 110mm dia PVC (SWR)Junction single (single or double T) equal or unequal complete all as specified and directed.
113S&F in repairs 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
114S&F in repairs Stack clamps for 110mm dia pipe made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
115S&F in repairs Stack clamps for 75mm dia pipe made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
116S&F 15mm dia Unplasticised PVC pipes of pressure rating 10kgf/sqcm with fittings fixed to walls,ceilings or in floor etc., any type of pipe complete as specified and directed.
117S&F 20mm dia Unplasticised PVC pipes of pressure rating 10kgf/sqcm with fittings fixed to walls,ceilings or in floor etc., any type of pipe complete as specified and directed.
118S&F 16mm outer diameter CPVC pipes SDR 11 with and including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. (Note:- Special fittings shall be measured and paid for as \\"S&F\\" separately.
119S&F 20mm outer diameter CPVC pipes SDR 11 with and including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. (Note:- Special fittings shall be measured and paid for as \\"S&F\\" separately .
120S&F special fittings of Brass elbow for 16mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed.
121S&F special fittings of Brass Tee for 16mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed.
122S&F special fittings of Male Brass Threaded Adaptor (MTA/ MBTA) for 16mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed.
123S&F special fittings of Female Brass Threaded Adaptor (FTA/ FBTA) for 16mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed.
124S&F special fittings of Tank Adaptor for 16mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed.
125S&F special fittings of Union for 16mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed.
126S&F special fittings of Brass elbow for 20mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed.
127S&F special fittings of Brass Tee for 20mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed.
128S&F special fittings of Male Brass Threaded Adaptor (MTA/ MBTA) for 20mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed.
129S&F special fittings of Female Brass Threaded Adaptor (FTA/ FBTA) for 20mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed.
130S&F special fittings of Tank Adaptor for 20mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed.
131S&F special fittings of Union for 20mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed.
132S&F 15mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, laid in trenches complete all as specified and directed.
133S&F 20mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, laid in trenches complete all as specified and directed.
134Refixing only old retrieved serviceable 15mm bore Galvanised Medium Grade Steel Water Tubing and fixed to walls,and ceilings or laying in floors in new or old position with and including new fittings and connections complete all as specified and directed.
135Refixing only old retrieved serviceable 20mm bore Galvanised Medium Grade Steel Water Tubing and fixed to walls,and ceilings or laying in floors in new or old position with and including new fittings and connections complete all as specified and directed.
136S&F 15mm bore Bib Taps, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed.
137S&F 15mm bore Bib Taps, long body, swan neck movable, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed.
138S&F in repairs 15mm bore fancy type, chromium plated, Stop valves, cast copper alloy, with long shank and cup concealed type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
139S&F in repair 15mm bore Angle/Angular stop Valves, fancy type, chromium plated, cast copper alloy, with flange, one way turn, screwed down high pressure, with crutch or butterfly handle, screwed for iron pipe complete all as specified and directed.
140S&F in repairs 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and directed.
141S&F in repairs 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and directed.
142S&F in repair pressure Jet spray of chromium plated steel for EWC seats with and including including PVC connection and CP fittings complete all as specified and directed.
143S&F in repairs 15mm bore Pillar Taps, fancy type, chromium plated, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
144S&F in repairs 32mm bore PVC waste pipe of suitable length to waste coupling pipe attached with rubber ring joints/ PVC threaded cup, fixed to waste coupling of sinks / WHBs/urinal of required length complete all as specified and directed.
145S&F in repairs 32mm bore Waste fittings of chromium plated brass for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
146S&F in repairs 15mm PVC connections 450mm long heavy duty with brass nuts adaptors and washers and rubber gaskets at both ends complete all as specified and directed.
147S&F 15mm PVC connections 600mm long heavy duty with brass nuts adaptors and washers and rubber gaskets at both ends complete all as specified and directed.
148S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. hoisted and fixed complete as specified in SSR Part-I. complete all as specified and directed.
149S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. hoisted and fixed omplete as specified in SSR Part-I. complete all as specified and directed.
150S&F in repars 20mm bore Ball valves high pressure of PTMT withepoxy coated Aluminium rod & high density plastic float ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210gms./25mm-455gms/ 40mm- 690 gms) complete all as specified and directed.
151S&F 20mm bore Ball valves high pressure of PTMT withepoxy coated Aluminium rod & high density plastic float ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210gms./25mm-455gms/ 40mm- 690 gms) complete all as specified and directed.
152S&F in repars 15/20mm dia galvanised iron nipple for old or new PVC water tank complete all as specified and directed.
153S&F in repairs Wash Hand Basins, Vitreous China (flat back) white of size 550mm X 400mm including cutting for and pinning in ends of brackets or erecting stand including waste fittings, 32 mm bore PVC flush pipe with long screwed shucks and fly nuts and including PVC discharge pipe complete all as specified and directed.
154S&F in repairs Vitreous China Squatting Pan, \\"Orissa pattern\\", size 580x440mm white/ coloured with integral foot rests (excluding flushing cistern, flush pipe and waste pipe), including trap and connection to trap, and to flushing pipe, anti-syphonage pipe, etc.complete including all joints and making good to floors complete all as specified and directed.
155S&F in repairs Vitreous China Wash Down Water Closet Pan (pedestal pattern) complete, white/ coloured including seat and cover, trap, including connection to drain (or outgoing pipe), and to flushing pipe, anti-syphonage pipe, etc. etc.complete including all joints and making good to floors complete all as specified and directed.
156S&F in repairs 10 litres capacity low level PVC valveless syphonic action type flushing cistern with inlet ball valve, float and flush handle complete all as specified and directed.
157S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified complete all as specified and directed.
158S&F Corner glass shelves 225mm radius,6mm thick as per sample for bath room, fixed on suitable support all as directed complete all as specified and directed.
159S&F in repairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
160S&F in repair Stainless steel plate rack of standard pattern & of size 900 x 750 x 250 mm.The thickness of stainless steel sheet shall be 1.00 mm & grade of sheet shall be 304 AISI including fixing to wall with 4 Nos 50mm screws & PVC rawl plugs complete all as specified and directed.
161S&F in repairs grating doom 125mm dia of PTMT with waste hole of PTMT. (Minimum weight 40gms) complete all as specified and directed.
162S&F in repairs grating doom 100mm dia of PTMT with waste hole of PTMT. (Minimum weight 40gms) complete all as specified and directed.
163S&F 100 mm dia Chromium plated brass shower rose with 125mm long CP arms, with or without swivel joints, including fixing complete to steel pipe or union complete all as specified and directed.
164S&F 600mmx450mm size of specified thickness looking mirror, bevelled edge of selected quality glass with aluminium frame made of channel around, mounted on 6mm thick commercial ply or AC building board, fitted to wooden plug with chromiumplated brass screws and cup washers complete all as specified and directed.
165S&F in repairs 20mm dia brass chromium plated tubular towel rail 600mm long between flanges type \\"D\\", with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms)complete all as specified and as directed.
166S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
167S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
168S&F in repairs CP brass Toilet Paper Holder with Flap fixed to wall with CP brass screws and PVC gutties complete all as specified and directed.
169S&F in repair Plastic water closet Seat Cover (Whitecolour), black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging deviceSeat Cover for pedestal pattern complete all as specified and directed.
170S&F in repairs 20mm dia mild steel epoxy powder coated curtain rod with fancy type brackets including with all fittings rings @ 10 nos per RM , bulbs, finials, fixed with PVC rawl plugs and CP steel screws complete all as specified and directed.
171S&F in repairs PVC Bathroom cabinet with mirror of size 450x 600mm fixed to wall with chromium plated steel screws and PVC gutties complete all as specified and directed.
172S&F central hole basin mixer for wash hand basin including all fittings ie including connection pipe as per manufactures specification complete all as specified and directed.
173S&F 15mm bore chromium plated brass Wall mixer wall ( over head shower type) mounted for mixing hot and cold water screwed down for pipe with provision of overhead shower complete with 115 mm long bend pipe on upper side, connecting legs and wall flange complete all as per manufacturer's instruction and as directed.
174Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
175M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) drawn in and through and including non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and new GI sunken boxes of suitable size for mounting Modular fittings i.e. cover plates with frame, GI metal flush boxes, switches / bell pushes / sockets, fan regulator etc including continuous earth wire cable of size 1.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for One light/fan/Bell Point controlled by one single pole one way switch. Note:- Cutting chases for conduits and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. Switches, ceiling roses, pendants, regulators, sockets, bell push and bells junction boxes and modular fittings switches, ceiling roses, pendants, regulators, bell push and bells, sockets,junction boxes, cover plates with frame , GI metal flush boxes shall be measured and paid for separately.
176ditto all as per item No 175 above but for One 3 pin socket outlet 5/6 Amp on the same board controlled by one single pole one way switch
177ditto all as per item No 175 above but for One 5/6 Amps socket outlet independent controlled by one single pole 5/6 Amp switch.
178M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 2.5 Sqmm (nominal area) drawn in through and including non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and new GI sunken boxes of suitable size for mounting Modular fittings i.e. cover plates with frame, GI metal flush boxes, switches / bell pushes / sockets, fan regulator etc including continuous earth wire cable of size 2.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for one 3/5 pin 15/16 Amps switch socket out let on the independent board controlled by one single pole one way switch. Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully.
179S&F Modular Switch, one way, 6A, 1 module complete all as specified and directed.
180S&F Modular Switch, one way, 16A, 1 module complete all as specified and directed.
181S&F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
182S&F Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
183S&F Modular white cover plate with frame, 1 module complete all as specified and directed.
184S&F Modular white cover plate with frame, 2 module complete all as specified and directed.
185S&F Modular white cover plate with frame, 3 module complete all as specified and directed.
186S&F Modular white cover plate with frame, 4 module complete all as specified and directed.
187S&F Modular white cover plate with frame, 6 module complete all as specified and directed.
188S&F Modular white cover plate with frame, 8 module complete all as specified and directed.
189S&F Modular Metal Flush Box, 1 module complete all as specified and directed.
190S&F Modular Metal Flush Box, 2 module complete all as specified and directed.
191S&F Modular Metal Flush Box, 3 module complete all as specified and directed.
192S&F Modular Metal Flush Box, 4 module complete all as specified and directed.
193S&F Modular Metal Flush Box, 6 module complete all as specified and directed.
194S&F Modular Metal Flush Box, 8 module complete all as specified and directed.
195S&F Modular Bell Push 6A, I module complete all as specified and directed.
196S & F Modular step type regulator,120 W - 2 module complete all as specified and directed.
197S & F Modular Dummy switch- 01 module complete all as specified and directed.
198S&F Ceiling Roses Ceiling rose, 3 phase/PVC/polycarbonate, isolated body omplete all as specified and directed.
199S&F Lamp holder PVC/Polycarbonate,isolated with back plate suitable for batten fittings ISI marked complete all as specified and directed.
200S&F bell, Ding Dong AC. 230 Volts, single pole complete all as specified and directed.
201Cutting holes/ opening 300mm diameter for fixing exhauist fan, grouting bolts, fixing with nuts and washers and making good in cement mortar (1:4) and finshing surface to match with existing surfaces complete all as specified and directed.
202Supply, hoist, fix and connect Ceiling Fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
203S&F 300mm sweep Exhaust Fan, steel body AC single Phase. 230V with blades and frame and louvers with Copper winding complete all as specified and directed.
204S&F 300mm sweep Exhaust Fan, sturdy Engineering plastic body with louvers with blades and frame and louvers with Copper winding AC single Phase. 230V , 1200 RPM, 50 Hz complete all as specified and directed.
205S&F LED tube light fitting 1x18 W, 4 feet long, decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient 230V, complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Cat Part No. LHEXBLP7UN1W018 of Make - Havells or equivalent as specified in Appendix \\"B\\" of Particular Specfications, complete all as specified and directed.
206S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed.
207S&F in repairs sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired VTPN DBs (Verticle type)fitted with ABS frame, TPN DBs, 415 Volts 200Amps rated bus bar,Neutral link,Earth bar and Din rail, 4 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified.
208S&F in repairs sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 Volts 200 Amps rated bus bar,Neutral link,Earth bar and Din rail, 8 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified.
209S&F Moulded Case Circuit Breaker (MCCB) Four Poles (FP) current carrying capacity 100Amp, 415 Volts, breaking capacity 16 KA with adjustable thermal and magnetic settings, complete all as specified and directed.
210S&F Miniature Circuit Breaker (MCB) Single Pole (SP) current carrying capacity 6 to 32 Amp, 240V, breaking capacity 10 KA, type 'B' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
211S&F Miniature Circuit Breaker (MCB) Single Pole and Neutral (SPN) current carrying capacity 32 Amp, 240V, breaking capacity 10 KA, type 'C' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
212S&F Miniature Circuit Breaker (MCB) Single Pole and Neutral (SPN) current carrying capacity 40 Amp, 240V, breaking capacity 10 KA, type 'C' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
213S&F in repairs Single Pole two Pin and Earth Plug and Socket including one single pole MCB 20 Amp fixed in and including sheet Metal enclosures, including taking down, complete all as specified and directed.
214M&L for submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size 4.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 4.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cable single core for continuous earthing complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 4.0Sqmm and one run of 4.0Sqmm PVC insulated copper conductor single core (2x4.0Sqmm+1x4.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run)
215S&F in repairs submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size 6.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 6.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cable single core for continuous earthing including taking down existing submain wiring and conduits etc complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 6.0Sqmm and one run of 6.0Sqmm PVC insulated copper conductor single core (2x6.0Sqmm+1x6.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run)
216Supply, lay, test, joint and commission LT XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 35 Sqmm x 3.5 core, 1100 Volts grade (1.1 KV earthed system); laid in trenches/under floor/through ducts, fixed on pole complete all as specified and directed. Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe shall be measured and paid separately under respective items of BoQ.
217Supply, lay, test, joint and commission LT XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 25 Sqmm x4 core, 1100 Volts grade (1.1 KV earthed system); laid in trenches/under floor/through ducts, on Hill / fixed on pole complete all as specified and directed. Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe shall be measured and paid separately under respective items of BoQ.
218Supply and lay 40mm bore galvanised pipe light grade of ISI marked for passing of cable fixed to poles/walls/laid under floor/ laid in trenches as cable protection complete with and including fittings as required compete all as specified and directed.Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid separately under respective items of BoQ.
219M&L for Sand cushioning using sand suitable for plaster works to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep punned to 10cm after laying and stretching the cable complete all as specified and directed. Note : 18 cm punned thickness shall be measured and paid.
220Supply and lay cable protection cover with Bricks; common burnt clay building bricks, sub-class ‘B’ designation 75, (size 23cmx11.5cmx7.5cm) putting accross the cable with width of protection cover equal to length of brick, abutting to each other for cable protection complete all as specified and directed.
221M&L for Earthing complete with Galvanised Iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at (Earth pit not less than 2.25m deep below ground level) a depth not less than 2.25m below normal ground level with top edge of earth plate at depth not less than 1.5m below normal ground level surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using 4mm dia galvanised earth wire by means of bolts, nuts, check nuts and washers of galvanized iron and protected by 15mm bore GI pipe light grade connected to main switch board or main control board and 20mm bore GI pipe light grade for watering and including funnel, wire mesh, 80mm thick pre-cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4Kg/Sqm in lieu of CI cover, PCC (1:2:4) type B-1 pit/chamber including all necessary excavation: and earth work, form work, disposal of surplus soil to a distance not exceeding 50m all as specified and al shown in Electrical Plate No.3 of MES Standard Schedule of Rates 2009 Part-I complete all as specified and directed.Note:- (i) The unit rate shall deemed to include for Test point, PCC pit, 4mm dia GI earth wire from top of the earth plate up to 7.5m above ground level. In case 15mm bore GIprotection pipe required is less than 7.5m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate.(iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57689691
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 21-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Building No Np-14, Np-21, Np-17 And Np-16 In The Aor Of Age B/R-Ii Under Ge (West) Ferozepur
Basic Detail
Tender No CWE/FZR-77/2026-27
Bidding Type Tender
Location
City Firozepur
State Punjab
Key Dates
Publish Date 28 Sep 2026
Submission Date 21 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee 1000
EMD 2.24 Lakhs
Exemption Available
Document List
9d2324d8-9317-4aa2-aa69-484781d750a8.html
BOQ_886736.xls
Tender77.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 21, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 17 days
Oct 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

9d2324d8-9317-4aa2-aa69-484781d750a8.html

xls

BOQ_886736.xls

pdf

Tender77.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders