Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - For The Work Of Pd And Tan Delta Testing At Various Sub Stations Under Etc Azamgarh; Substation; Service Provider - Following Testing Works Are To B
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - For The Work Of Pd And Tan Delta Testing At Various Sub Stations Under Etc Azamgarh; Substation; Service Provider - Following Testing Works Are To Be Conducted For Health Monitring Of Various Current Transformers In 400Kv And 220Kv Bays At Different Sub Stations Under Etc Azamgarh. Partial Discharge Test Of Both Ehf ( Extra High Frequency) And Hf ( High Frequency) Methods With Help Of Duly Calibrated Test Kit. The Work Also Includes The Cost Of Carriage And Operation Of Test Kit Including Preparation And Submission Of Test Results In Specified Formats After The Completion Of Test. The Test Results Should Clearly Mention The Health Of Cts And Suggestion For Action Taken Regarding The Same. (Voltage Level 400Kv ) 400Kv S/S Azamgarh - Ct 30 No., Pt/Cvt 21 No.400Kv S/S Kasara-Mau - Ct 30 No. Pt/Cvt 24 No.400Kv S/S Ballia - Cvt 06 No.(Voltage Level 220Kv ) 220Kv S/S Azamgarh - Ct 24 No., Pt/Cvt 18 No.220Kv S/S Azamgarh-Ii -Ct 18 No., Pt/Cvt 12 No.220Kv S/S Rasara -Ct 12 No., Pt/Cvt 21 No. (Voltage Level 132Kv ) 400Kv S/S Kasara-Mau -Ct 45 No., Pt/Cvt 33 No.Etd Azamgarh -Ct 26 No., Pt/Cvt 14 No.Etd Mau -Ct 30 No., Pt/Cvt 22 No.Etd Ballia -Ct 26 No., Pt/Cvt 09 No.400 Kv Ct , 400 Kv Pt/Cvt , 220 Kv Ct , 220 Kv Pt/Cvt , 132 Kv Ct , 132Kv Pt/Cvt , Capacitance And Tan Delta Measurement Testing Of Cts With The Help Of Duly Calibrated Test Kits To Be Arranged By The Contractor Including The Cost Of Carriage And Operation Of Test Kit Including Preparation And Submission Of Test Result In Specified Formats After The Completion Of Tests. The Tests Shall Include Capacitance, Tan Delta & Ir Value Measurements (To Be Conducted By Duly Calibarated Test Kit). The Works Shall Include The Cost Of Carriage Of Test Kit, Manpower Involved In Testing And Submission Of Test Reports In Specified Formats.(Voltage Level 400Kv ) 400Kv S/S Azamgarh - Ct 30 No., Pt/Cvt 21 No.400Kv S/S Kasara-Mau - Ct 30 No. Pt/Cvt 18 No.400Kv S/S Ballia - Cvt 06 No.(Voltage Level 220Kv ) 220Kv S/S Azamgarh-1 - Ct 18 No., Pt/Cvt 12 No.220Kv S/S Azamgarh-Ii -Ct 18 No., Pt/Cvt 12 No.220Kv S/S Rasara -Ct 12 No., Pt/Cvt 21 No. 400 Kv Ct , 400 Kv Pt/Cvt , 220 Kv Ct , 220 Kv Pt/Cvt , Visit Charges (From Company To Upptcl) Including The Cost Of Carriage Of All The Test Kits Required For Activities A Particulary Bay Of Cts . The Test Required In A Particular Bay Shall Be Completed In A Single Visit As Per Availabity Of Shutdown / Bay Condition .
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Following Testing works are to be conducted for health monitring of various Current Transformers in 400kV and 220kV Bays at Different Sub Stations under ETC Azamgarh. Partial discharge Test of both EHF ( Extra High Frequency) and HF ( High Frequency) methods with help of duly calibrated test kit. The work also includes the cost of carriage and operation of test kit including preparation and submission of test results in specified formats after the completion of test. The test results should clearly mention the health of CTs and Suggestion for action taken regarding the same. (Voltage level 400kV ) 400kV S/s Azamgarh - CT 30 No., PT/CVT 21 No.400kV S/s Kasara-Mau - CT 30 No. PT/CVT 24 No.400kV S/s Ballia - CVT 06 No.(Voltage level 220kV ) 220kV S/s Azamgarh - CT 24 No., PT/CVT 18 No.220kV S/s Azamgarh-II -CT 18 No., PT/CVT 12 No.220kV S/s Rasara -CT 12 No., PT/CVT 21 No. (Voltage level 132kV ) 400kV S/s Kasara-Mau -CT 45 No., PT/CVT 33 No.ETD Azamgarh -CT 26 No., PT/CVT 14 No.ETD Mau -CT 30 No., PT/CVT 22 No.ETD Ballia -CT 26 No., PT/CVT 09 No.400 KV CT | Following Testing works are to be conducted for health monitring of various Current Transformers in 400kV and 220kV Bays at Different Sub Stations under ETC Azamgarh. Partial discharge Test of both EHF ( Extra High Frequency) and HF ( High Frequency) methods with help of duly calibrated test kit. The work also includes the cost of carriage and operation of test kit including preparation and submission of test results in specified formats after the completion of test. The test results should clearly mention the health of CTs and Suggestion for action taken regarding the same. (Voltage level 400kV ) 400kV S/s Azamgarh - CT 30 No., PT/CVT 21 No.400kV S/s Kasara-Mau - CT 30 No. PT/CVT 24 No.400kV S/s Ballia - CVT 06 No.(Voltage level 220kV ) 220kV S/s Azamgarh - CT 24 No., PT/CVT 18 No.220kV S/s Azamgarh-II -CT 18 No., PT/CVT 12 No.220kV S/s Rasara -CT 12 No., PT/CVT 21 No. (Voltage level 132kV ) 400kV S/s Kasara-Mau -CT 45 No., PT/CVT 33 No.ETD Azamgarh -CT 26 No., PT/CVT 14 No.ETD Mau -CT 30 No., PT/CVT 22 No.ETD Ballia -CT 26 No., PT/CVT 09 No.400 KV CT |
| 2 | 400 KV PT/CVT | 400 KV PT/CVT |
| 3 | 220 KV CT | 220 KV CT |
| 4 | 220 KV PT/CVT | 220 KV PT/CVT |
| 5 | 132 kV CT | 132 kV CT |
| 6 | 132kV PT/CVT | 132kV PT/CVT |
| 7 | Capacitance and Tan Delta Measurement Testing of CTs with the help of duly calibrated test Kits to be arranged by the contractor including the cost of carriage and operation of Test Kit including preparation and submission of test result in specified formats after the completion of tests. The tests shall include capacitance, Tan Delta & IR value measurements (To be conducted by duly calibarated test Kit). The works shall include the cost of carriage of Test Kit, Manpower involved in testing and submission of test reports in specified formats.(Voltage level 400kV ) 400kV S/s Azamgarh - CT 30 No., PT/CVT 21 No.400kV S/s Kasara-Mau - CT 30 No. PT/CVT 18 No.400kV S/s Ballia - CVT 06 No.(Voltage level 220kV ) 220kV S/s Azamgarh-1 - CT 18 No., PT/CVT 12 No.220kV S/s Azamgarh-II -CT 18 No., PT/CVT 12 No.220kV S/s Rasara -CT 12 No., PT/CVT 21 No. 400 KV CT | Capacitance and Tan Delta Measurement Testing of CTs with the help of duly calibrated test Kits to be arranged by the contractor including the cost of carriage and operation of Test Kit including preparation and submission of test result in specified formats after the completion of tests. The tests shall include capacitance, Tan Delta & IR value measurements (To be conducted by duly calibarated test Kit). The works shall include the cost of carriage of Test Kit, Manpower involved in testing and submission of test reports in specified formats.(Voltage level 400kV ) 400kV S/s Azamgarh - CT 30 No., PT/CVT 21 No.400kV S/s Kasara-Mau - CT 30 No. PT/CVT 18 No.400kV S/s Ballia - CVT 06 No.(Voltage level 220kV ) 220kV S/s Azamgarh-1 - CT 18 No., PT/CVT 12 No.220kV S/s Azamgarh-II -CT 18 No., PT/CVT 12 No.220kV S/s Rasara -CT 12 No., PT/CVT 21 No. 400 KV CT |
| 8 | 400 KV PT/CVT | 400 KV PT/CVT |
| 9 | 220 KV CT | 220 KV CT |
| 10 | 220 KV PT/CVT | 220 KV PT/CVT |
| 11 | Visit Charges (From company to UPPTCL) including the cost of carriage of all the test kits required for activities a particulary bay of CTs . The test required in a particular bay shall be completed in a single visit as per availabity of Shutdown / Bay Condition . | Visit Charges (From company to UPPTCL) including the cost of carriage of all the test kits required for activities a particulary bay of CTs . The test required in a particular bay shall be completed in a single visit as per availabity of Shutdown / Bay Condition . |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender