Bids Are invited for Hand Dryer - Power Consumption Heater On 545 To 585W Power Supply Ac 240V Drying Time 15 Sec Weight 3.0Kg Noise Level 49Dbmaterial Plastic (Pp) Size 245W X 154D X 226H Mm , Hand Dispenser - Liquid Sanitizer Capacity Of The Unit 5L Mode Of Operation Automatic Mist Mode Usage Contactless Weight 3.5 Kg Dimensions 296 Mm X 235 Mm X 372Mm Electrical Input 230V Ac 5 Power Consumptionidle Mode 3Vawhen Spraying 12Va Approx Mounting Style Wall Mount Table Top , Multipara Monitor - Display 8.4 Inch To 12.1 Inch High Resolution Color Tft Lcd Screen Supporting 7 Or More Simultaneous Waveformsstandard Parameters 3 Lead Or 5 Lead Ecg Heart Rate Hr Non Invasive Blood Pressure Nibp Blood Oxygen Saturation Spo2 Pulse Rate Pr Respiration Rate Resp And Dual Channel Temperature Optional Advanced Parameters Invasive Blood Pressure Ibp Etco2 Mainstream Sidestream Microstream And Anesthetic Gas Monitoring Agm Patient Categories Configurable Modes Suitable For Adult Pediatric And Neonatal Patients Including Oxycrg Measurements Alarms And Memory Audible And Visual Adjustable Alarms With 72 Hours Or More Of Tabular And Graphical Trend Data Storage , White Film For Glass - Material Typically Durable Polyvinyl Chloride Pvc Or Specialized Polyester With Static Cling Or Self Adhesive Backing Privacy Level Offers 95 Percent To 100 Percent Two Way Privacy Protection Blocking Unwanted Views From Both Inside And Outside Uv And Heat Control Blocks Roughly 95 Percent To 97 Percent Of Harmful Uv Rays To Prevent Furniture Fading And Reduces Glare With Basic Thermal Insulation For Summer And Winter Installation Available As Non Adhesive Static Cling Applied Using Water Or Soapy Water Or Self Adhesive Glue Backing Leaving No Sticky Residue Upon Removal Common Sizes Standard Rolls Range From 16 To 24 Inches In Width And 48 To 80 Inches In Length Easily Trimmable With A Utility Knife , Surgical Tray 10 Inch X 12 Inch - Dimensions 12 Inches X 10 Inches Approximately 305 Mm X 254 Mm With A Depth Of 2 Inches Approximately 51 Mmmaterials High Grade 304 Stainless Steel Rust Resistant And Polished Mirror Finish Or Enamel Coated Metal White And Non Porous Surface Sterilization Fully Compatible With Standard Steam Autoclave Cycles And Chemical Disinfection Design Features Rectangular Shape With Raised Edges Or Ribs For Condensate Run Off And Optional Matching Fitted Lids To Maintain Sterility During Transport And Storage , Surgical Tray 12 Inch X 15 Inch - Dimensions 15 Inches X 12 Inches X 2 Inches 381 Mm X 305 Mm X 51 Mm Material Premium 304 Grade Stainless Steel Austenitic Highly Corrosion And Rust Resistant Thickness Approximately 0.6 Mm Heavy Duty Wall Construction To Maintain Structural Rigidity Under A Full Procedure Set Finish Mirror Polished Finish With Smooth Rounded Edges For Enhanced Hygiene And Easy Cleaning Sterilization Fully Reusable And Engineered To Withstand Standard High Temperature Steam Autoclave And Prevacuum Cycles , Surgical Tray 8 Inch X 6 Inch - Dimensions 8 X 6 Inches Approximately 203.2 X 152.4 Mm With A Standard Depth Of About 2 Inches Material Premium Medical Grade 304 Stainless Steel Which Resists Rust And Corrosion From Frequent Sterilization Thickness Usually Around 0.6 Mm To Hold Its Shape Securely Without Excess Weight Lid Includes A Matching Fitted Lid That Seats Inside The Rim To Protect Tools From Contamination During Storage And Transport , Epsotomy Scissors - Overall Length Typically Ranges From 14 Cm To 24 Cm Commonly 5.5 Inches 14 Cm 6 Inches 15 Cm Or 8.5 Inches 21 To 24 Cm Material High Grade Medical Or Surgical Stainless Steel Often Martensitic Or German Stainless Steel For Corrosion Resistance And Durability Blade Design Angled Sideways Or Curved To The Side To Optimize Visibility And Follow Natural Perineal Contours Tip Configuration Blunt Blunt Blunt Sharp Or Rounded Tips To Facilitate Safe Blunt Dissection And Prevent Accidental Piercing Of Nearby Tissue , Stadiometer - Measuring Range 20 Cm To 210 Cm Approximately 0.5 To 6.9 Ft Suitable For Children Above 2 Years And Adultsgraduation Accuracy 0.1 Cm Or 1 Mm Precision Increments Scale Graduations Dual Metric Centimeters And Millimeters And Imperial Inches And Feet Markings Oriented Parallel To The Board Board Width Approximately 5.5 Cm Wide Vertical Measuring Column Or Backplate Material Construction Durable Medical Grade Material Suitable For Regular Clinical Use , Autoclave Element - Power Rating Wattage Commonly 1000W 1 Kw For Small Portable Units 2000W 2 Kw To 3000W 3 Kw For Standard Medical Laboratory Benchtop Units And Up To 6000W 6 Kw Or Higher For Large Industrial Or Horizontal Autoclaves Operating Voltage Standard 220V To 230V Ac Single Phase Or Higher For Industrial Multi Phase Setups Material Composition High Grade Stainless Steel Ss304 Or Ss316 Or Brass For Corrosion Resistance And Thermal Tolerance Inside Water Heating Chambers , Surgical Drum Medium - Material High Grade Stainless Steel Typically Ss 304 Grade For Rust And Corrosion Resistance Dimensions Medium Sizes Diameter 9 Inches Approx 228 Mm Height 6 Inches Or 9 Inches Approx 150 Mm To 228 Mm , Surgical Drum Large - 20 X 12 For Heavy Hospital Use Sterilization Fully Autoclavable Designed To Withstand High Temperature Steam Cycles Ventilation Precision Perforated Sliding Band Or Side Bottom Vent Clusters That Open For Steam Penetration During Autoclaving And Close For Sterile Storage Locking Mechanism Heavy Duty Drop Down Hasps Side Clips Or A Secure Single Cl Latch To Maintain Internal Sterility During Transport Application Used For Sterilizing And Storing Gauze Pads Surgical Cotton Bandages And Medical Instruments In Operation Theatres And Clinics , Surgical Drum Small - 11 X 9 Heavy Hospital Use Sterilization Fully Autoclavable Designed To Withstand High Temperature Steam Cycles Ventilation Precision Perforated Sliding Band Or Side Bottom Vent Clusters That Open For Steam Penetration During Autoclaving And Close For Sterile Storage Locking Mechanism Heavy Duty Drop Down Hasps Side Clips Or A Secure Single Cl Latch To Maintain Internal Sterility During Transport Application Used For Sterilizing And Storing Gauze Pads Surgical Cotton Bandages And Medical Instruments In Operation Theatres And Clinics , Nebulizer Machine - Particle Size Mmad 1 To 5 Um Micrometers Which Ensures The Mist Reaches The Lower Airways Effectively Medication Capacity 6 Ml To 10 Ml Max Volume In The Medicine Cup Nebulization Rate 0.2 Ml Min To 0.4 Ml Min For Steady Mist Output Noise Level Typically Between 45 Db To 60 Db Depending On Whether It Is A Compact Or Standard Compressor Model Power Supply Ac Power Adapter 220V 110V Or Battery Options For Portable Units Weight Ranges From 150G To 250G For Compact Travel Units Like The Omron Healthcare Nebulizer Up To 1 Kg For Heavier Clinical Grade Compressors , Bp Cuff - 37 To 50 Of Arm Circumference Roughly 12 16 Cm For Standard Arms Bladder Length 75 To 100 Of Arm Circumference Long Enough To Encircle The Arm Without Overlapping Excessively Accuracy Standards Devices And Cuffs Should Comply With Validation Protocols Like Iso 81060 2 , Elbow Tap - Operation Hands Free Wrist Or Elbow Activated Long Lever Handle Body Material Robust Corrosion Resistant Brass Finish Polished Chrome Or Silver Connection Size Standard 15Mm 1 2 Bsp Male Inlet Threads Valve Type Quarter Turn Ceramic Disc For Smooth Leak Free Operation Mounting Types Pillar Cock Deck Mounted Vertically On A Sink Or Countertop Bib Cock Wall Mounted Horizontally With An Inlet Flange Pressure Limits Designed For Balanced Water Systems Typically Up To 4 Bar 400 Kpa 60 Ps
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Hand dryer | Power Consumption Heater On 545 TO 585W Power Supply AC 240V Drying Time 15 sec Weight 3.0kg Noise Level 49dBMaterial Plastic (PP) Size 245W X 154D X 226H mm |
| 2 | Hand dispenser | Liquid Sanitizer capacity of the unit 5L Mode of operation Automatic Mist mode Usage Contactless Weight 3.5 kg Dimensions 296 mm X 235 mm X 372mm Electrical Input 230V AC 5Amp Power ConsumptionIdle Mode 3VAWhen Spraying 12VA approx Mounting Style Wall mount Table Top |
| 3 | Multipara monitor | Display 8.4 inch to 12.1 inch high resolution color TFT LCD screen supporting 7 or more simultaneous waveformsStandard Parameters 3 lead or 5 lead ECG Heart Rate HR Non Invasive Blood Pressure NIBP Blood Oxygen Saturation SpO2 Pulse Rate PR Respiration Rate RESP and Dual Channel Temperature Optional Advanced Parameters Invasive Blood Pressure IBP EtCO2 Mainstream Sidestream Microstream and Anesthetic Gas Monitoring AGM Patient Categories Configurable modes suitable for adult pediatric and neonatal patients including OxyCRG measurements Alarms and Memory Audible and visual adjustable alarms with 72 hours or more of tabular and graphical trend data storage |
| 4 | White film for glass | Material Typically durable Polyvinyl Chloride PVC or specialized polyester with static cling or self adhesive backing Privacy Level Offers 95 percent to 100 percent two way privacy protection blocking unwanted views from both inside and outside UV and Heat Control Blocks roughly 95 percent to 97 percent of harmful UV rays to prevent furniture fading and reduces glare with basic thermal insulation for summer and winter Installation Available as non adhesive static cling applied using water or soapy water or self adhesive glue backing leaving no sticky residue upon removal Common Sizes Standard rolls range from 16 to 24 inches in width and 48 to 80 inches in length easily trimmable with a utility knife |
| 5 | Surgical tray 10 inch x 12 inch | Dimensions 12 inches x 10 inches approximately 305 mm x 254 mm with a depth of 2 inches approximately 51 mmMaterials High grade 304 stainless steel rust resistant and polished mirror finish or enamel coated metal white and non porous surface Sterilization Fully compatible with standard steam autoclave cycles and chemical disinfection Design Features Rectangular shape with raised edges or ribs for condensate run off and optional matching fitted lids to maintain sterility during transport and storage |
| 6 | Surgical tray 12 inch x 15 inch | Dimensions 15 inches x 12 inches x 2 inches 381 mm x 305 mm x 51 mm Material Premium 304 grade stainless steel austenitic highly corrosion and rust resistant Thickness Approximately 0.6 mm heavy duty wall construction to maintain structural rigidity under a full procedure set Finish Mirror polished finish with smooth rounded edges for enhanced hygiene and easy cleaning Sterilization Fully reusable and engineered to withstand standard high temperature steam autoclave and prevacuum cycles |
| 7 | Surgical tray 8 inch x 6 inch | Dimensions 8 x 6 inches approximately 203.2 x 152.4 mm with a standard depth of about 2 inches Material Premium medical grade 304 stainless steel which resists rust and corrosion from frequent sterilization Thickness Usually around 0.6 mm to hold its shape securely without excess weight Lid Includes a matching fitted lid that seats inside the rim to protect tools from contamination during storage and transport |
| 8 | Epsotomy scissors | Overall Length Typically ranges from 14 cm to 24 cm commonly 5.5 inches 14 cm 6 inches 15 cm or 8.5 inches 21 to 24 cm Material High grade medical or surgical stainless steel often martensitic or German stainless steel for corrosion resistance and durability Blade Design Angled sideways or curved to the side to optimize visibility and follow natural perineal contours Tip Configuration Blunt blunt blunt sharp or rounded tips to facilitate safe blunt dissection and prevent accidental piercing of nearby tissue |
| 9 | Stadiometer | Measuring Range 20 cm to 210 cm approximately 0.5 to 6.9 ft suitable for children above 2 years and adultsGraduation Accuracy 0.1 cm or 1 mm precision increments Scale Graduations Dual metric centimeters and millimeters and imperial inches and feet markings oriented parallel to the board Board Width Approximately 5.5 cm wide vertical measuring column or backplate Material Construction Durable medical grade material suitable for regular clinical use |
| 10 | Autoclave element | Power Rating Wattage Commonly 1000W 1 kW for small portable units 2000W 2 kW to 3000W 3 kW for standard medical laboratory benchtop units and up to 6000W 6 kW or higher for large industrial or horizontal autoclaves Operating Voltage Standard 220V to 230V AC single phase or higher for industrial multi phase setups Material Composition High grade Stainless Steel SS304 or SS316 or Brass for corrosion resistance and thermal tolerance inside water heating chambers |
| 11 | Surgical drum Medium | Material High grade stainless steel typically SS 304 grade for rust and corrosion resistance Dimensions Medium Sizes Diameter 9 inches approx 228 mm Height 6 inches or 9 inches approx 150 mm to 228 mm |
| 12 | Surgical drum Large | 20 x 12 for heavy hospital use Sterilization Fully autoclavable designed to withstand high temperature steam cycles Ventilation Precision perforated sliding band or side bottom vent clusters that open for steam penetration during autoclaving and close for sterile storage Locking Mechanism Heavy duty drop down hasps side clips or a secure single clamp latch to maintain internal sterility during transport Application Used for sterilizing and storing gauze pads surgical cotton bandages and medical instruments in operation theatres and clinics |
| 13 | Surgical drum small | 11 x 9 heavy hospital use Sterilization Fully autoclavable designed to withstand high temperature steam cycles Ventilation Precision perforated sliding band or side bottom vent clusters that open for steam penetration during autoclaving and close for sterile storage Locking Mechanism Heavy duty drop down hasps side clips or a secure single clamp latch to maintain internal sterility during transport Application Used for sterilizing and storing gauze pads surgical cotton bandages and medical instruments in operation theatres and clinics |
| 14 | Nebulizer machine | Particle Size MMAD 1 to 5 um micrometers which ensures the mist reaches the lower airways effectively Medication Capacity 6 ml to 10 ml max volume in the medicine cup Nebulization Rate 0.2 ml min to 0.4 ml min for steady mist output Noise Level Typically between 45 dB to 60 dB depending on whether it is a compact or standard compressor model Power Supply AC power adapter 220V 110V or battery options for portable units Weight Ranges from 150g to 250g for compact travel units like the Omron Healthcare Nebulizer up to 1 kg for heavier clinical grade compressors |
| 15 | BP cuff | 37 to 50 of arm circumference roughly 12 16 cm for standard arms Bladder Length 75 to 100 of arm circumference long enough to encircle the arm without overlapping excessively Accuracy Standards Devices and cuffs should comply with validation protocols like ISO 81060 2 |
| 16 | Elbow tap | Operation Hands free wrist or elbow activated long lever handle Body Material Robust corrosion resistant brass Finish Polished chrome or silver Connection Size Standard 15mm 1 2 BSP male inlet threads Valve Type Quarter turn ceramic disc for smooth leak free operation Mounting Types Pillar Cock Deck mounted vertically on a sink or countertop Bib Cock Wall mounted horizontally with an inlet flange Pressure Limits Designed for balanced water systems typically up to 4 bar 400 kPa 60 ps |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender