Communications and Information Technology Government Departments Closing in 18 days TDR #57684305

Tender For Construction Of Civil, Interior Works & Mep Works Of Makeshift Atal Innovation Studio & Accelerator At Bharatpur

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
4.39 Crore
Estimated cost
Bid Submission
14 Oct 2026
18 days left
EMD
8.80 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Civil, Interior Works & Mep Works Of Makeshift Atal Innovation Studio & Accelerator At Bharatpur

BOQ

Name of Work:- Construction of Civil, Interior works & MEP works of Makeshift Atal Innovation Studio & Accelerator at Bharatpur
Sl. No. Item Description
1Part A-Civil works
2Half brick masonry in Superstructure , above plinth level uptofloor V level using bricks of designation 75 Cement mortar 1 : 4 (1 cement : 4 coarse sand) (the rate is inclusive of work upto all floor level including scaffolding & double scafloding )
3Providing and carrying out surface preparation and waterproofing treatment including cleaning of surface, removal of all loose materials, dust, laitance, and filling of cracks using Polymer Modified Mortar (PMM) complete as per specifications.Applying one coat of primer using CICO Hydraguard PMB or equivalent on the prepared surface as per manufacturer’s specifications.Providing and applying two coats of CICO Hydraguard PMB (Polymer Modified Bitumen) waterproofing compound as per TDS including proper drying time between coats.Providing and laying protective plaster using approved Sika sand / coarse sand, cement and suitable admixture, finished with steel trowel to a thickness up to 25 mm, complete in all respects. Curing of protective plaster for a minimum period of 7 days. Contractor and manufacturer shall provide the Warranty certificate of 10 years.
4P & F 1st quality fully body Vitrified Porcelain Polished tiles with skirting of size 600 x 1200mm height, 10 mm thick and on floor and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with CM 1 : 4 as per drawing, Tiles will be laid with 5 mm gap using spacers and gap will be filled with matching color epoxy latictere Size 600 x 1200 mm.
5Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 12 mm thk. Cost includes scaffolding and filling joints between concrete and masonry in cement mortar including racking the joints to form \\"V\\" groove (the rate is inclusive of work upto all floor level including scaffolding & double scafloding )
6Two or more coats on new work including prepartion of basewith primer, putty, lippy etc complete in all respect
7Repairs to plaster of thickness 12mm to 20mm in patches ofarea 2.5 sq. metres and under including cutting the patch inproper shape, raking out joints and preparing and plasteringthe surface of the walls complete including disposal of rubbishto the dumping ground within 50 m lead With cement mortar1 :4 ( 1 cement : 4 coarse sand)
8Renewing glass panes,with putty and nails wherever necessary13.4.1 Float glass panes of thickness 5 mm
9Making holes in stone masonry wall upto 450 mm x 450 mmsize and making good in CM 1:6.
10Making of hole in R.C.C. slab/wall/beams and masonary wall(width up to 450 mm) by core cutting machine complete as perdirection of EI13.34.1 From diameter 100mm to 150mm
11Providing and fixing Granite stone slab mirror polished andmachine edge cut in walls, pillars, steps, Shelves, SillsCounters, Floors etc. laid on 12mm (Av.) thick base of cementmortar 1:3 (1 cement : 3 coarse sand) jointing with whitecement mortar 1:2 (1white cement : 2 marble dust) withpigment to match the shade of the marble slab includinggrinding, rubbing and polishing complete. Jalore (P-white / S-white/ Rosy Pink colour) Above 3601 Cm2 Slabs
12Supply & Fixing Structural Steel (IS 2062): Steel work welded, in built up sections framed work including cutting, hoisting, fixing with anchor bolts / fastners in position and applying priming coat of red oxide in columns, beams and joists, channels angles, tees flats with connecting plates or angle cleats. The rate shall include the cost of primer and two coats of enamel paint (of approved shade) on all structural steel work & scaffolding etc. at all height
13Acoustic Flooring area Concrete floor top finishing using by floater machine.(IPS Flooring) CC1:3:6
14Supplying, planting of Indoor POTTED PLANTS for following plants:
15Arica Palm(4' to 6')
16Philodendron selloum(2' to 3')
17Monastara(3' to 4')
18Brasia golden(2' to 3')
19Name Plates (Direction) - Base of Dye Aluminium with Polycarbonate sheet Both Sides & matter in 300 GSM paper Hanging on Ceiling with Stainless Steel Studs
20Providing, supplying and fixing of Push & Pull Metal Door Signage, comprising SS 304 grade stainless-steel plate of minimum 0.8 mm thickness, size approximately 150 × 50 mm (6\\" × 2\\"), with brushed/satin finish, machine/laser etched or screen-printed “PUSH” and “PULL” lettering/symbols in high-contrast finish, with rounded/chamfered edges, suitable for glass, wooden, aluminium or laminated doors. Signage shall be fixed using high-quality self-adhesive/3M tape or concealed mechanical fixing, including all materials, adhesive, preparation, fixing, labour, tools and tackles, complete as directed by Engineer-in-Charge.
21Dismantling stone slab/ terrazo chip flooring laid in cementmortar including stacking of serviceable material and disposalof unserviceable material within 50 meters lead.
22Dismantling tile work in floors and roofs laid in cement mortarincluding stacking of serviceable material and disposal ofunserviceable material within 50 meter lead: For thickness of tiles 25mm to 40mm.
23Providing and fixing stainless steel railing made of Hollowtubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (wherever required)and fitting the same with necessary stainless steel nuts andbolts complete, i/c fixing the railing with necessaryaccessories & stainless steel dash fasteners , stainless steelbolts etc., of required size, on the top of the floor or the side ofwaist slab with suitable arrangement as per approval ofEngineer-in-charge, (for payment purpose only weight ofstainless steel members shall be considered excluding fixingaccessories such as nuts, bolts, fasteners etc.).(a) Grade 304
24Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10mm and down gauge)including finishing with cement mortar 1:3 (1 cement : 3 finesand) as per standard design :
25Making khurras 450 x 450mm with average minimumthickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1: 3 and one coat of neat cement, rounding edges and makingand finishing the out let complete.
26Providing and fixing uPVC Sliding Windows made from extruded uPVC window profile sections, laminated/colour finish, factory fabricated and complete in all respects as follows:Frame: Made from extruded uPVC window profile section of size 106 × 50 mm (W × H) having outer wall thickness 2.5 mm (±0.2 mm) and 3-box multi-chamber construction, laminated/colour finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three-track configuration, two tracks for sliding window shutters and one track for mosquito mesh shutter. The vertical member of the frame bearing the sliding shutter load shall be provided with aluminium rail/track for smooth operation of shutter rollers. All four corners shall be mitred, cut and thermally welded to form a rigid and watertight frame. Frame shall be milled/provided with suitable drainage and air-equalizer holes for effective drainage of accumulated water towards the external side.Shutters: Sliding window shutters shall be made from extruded uPVC profile section of size 39 × 69 mm (W × H), laminated/colour finish, having outer wall thickness 2.5 mm (±0.2 mm) and 3-box multi-chamber construction, duly reinforced with 1.5 mm thick GI section. Shutter frames shall be mitred, cut and thermally welded at all corners and fitted with uPVC glazing beads of size 22 × 20 mm, complete with inner and outer co-extruded EPDM/TPE-E weather seals.The shutters shall be provided with suitable rollers, handles, locking arrangement and necessary hardware/fittings of approved make. Glazing shall be provided with approved thickness of toughened/clear glass, as specified, including suitable EPDM/TPE-E gasket/sealant.Mosquito Mesh Shutter: Providing and fixing separate sliding mosquito mesh shutter in the third track, fabricated from suitable uPVC/aluminium profile with approved fiberglass/SS mosquito mesh, complete with rollers, handle and necessary fittings.The complete window shall be installed true to line, level and plumb, securely fixed to the masonry/RCC opening using suitable GI/SS fixing screws, cleats, anchor fasteners, etc., including packing, sealing around the frame with approved silicone sealant, making good the adjoining surfaces and all necessary accessories, fittings, labour, scaffolding and incidental works, complete in all respects as per approved shop drawings, manufacturer's specifications and directions of the Engineer-in-Charge.
27SITC of outdoor LED illuminated institute display signage, comprising 3 mm ACP backing panel with GI/MS supporting frame, 3D raised acrylic/SS letters and logo, internally illuminated with IP65/IP67-rated LED modules, complete with SMPS, wiring, connectors, brackets, anchor fasteners and all electrical/fixing accessories; including fabrication, painting, erection, testing and commissioning, complete as per approved design and direction of Engineer-in-Charge
28Providing, supplying and fixing retro-reflective road/place-name signage board, comprising 2 mm thick aluminium sheet, duly edge-folded, with high-intensity Class C/DG retro-reflective sheeting, digitally printed/UV-resistant lettering and graphics, mounted on suitable GI/MS angle/channel frame with GI pipe supports, clamps, bolts and nuts, including excavation, foundation, fixing, painting, transportation and all accessories, complete as per approved design and direction of Engineer-in-Charge.
29Providing and fixing in position collapsible steel shutters withvertical M.S. Channels 20 x 10 x 2mm and bracket with flatiron diagonals 20 x 5mm. size with top and bottom rail of Tiron40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearingcomplete with bolts, nuts locking arrangements inside andoutside stoppers, handles etc. as per specification includingapplying a priming coat of approved steel primer, Including Locks. (To be measured and paid as per outer dimension).
30Providing and fixing expanded grill made of aluminum as perdesign and drawing having members section of size 7.5mm x6.0mm and opening of size 50mmx48mm to aluminumwindow/vent with required screws, Y and H aluminiumsection (as per drawing) at the ends and middle jointsrespectively complete in all respect as per direction ofengineer in charge. Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron)
31Providing and Fixing Chiken wire mesh at the joint ofmasonry members/ R.C.C. Members with Nails complete inall respect.
32Painting exterior surface of Wall with 100% acrylic exteriorpaint of approved brand and manufacture to give an evenshade with two or more coats including prepartion of basewith sand papering, primer, putty, etc complete in all respectincluding scaffolding and safety provision New Work
33Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade :12.46.1 Two or more coats on new work
34Providing corrugated G.S. sheet roofing including vertical /curved surface fixed with polymer coated J or L hooks, boltsand nuts 8 mm diameter with bitumen and G.I. limpet washersor with G.I. limpet washers filled with white lead andincluding a coat of approved steel primer and two coats ofapproved paint on overlapping of sheets complete (upto anypitch in horizontal/ vertical or curved surfaces) excluding thecost of purlins, rafters and trusses and including cutting to sizeand shape whenever required. 1.00 mm thick with zinc coating not less than 275 gm/m2
35Providing and fixing High Pressure Laminate (HPL) ceiling made of standard G.I. Sections framing and HPL planks of size 150mm wide and 4mm Groove inclusive of all hangers, edge members and other clips complete, with planks fixed with proper screws by power drills and joints duly finished ensuring level in line and plumb to take final finish. All inclusive of detailed cut-outs for light fixtures, AC grilles. All Vertical drops will be measured extra as per actuals.The cost to be inclusive of scaffolding, framing, edge profiles and end profiles, colored rivet/screws ( MODE OF MEASUREMENT L x B) .
36Demolishing brick work manually/ by mechanical meansincluding stacking of serviceable material and disposal ofunserviceable material within 50 metres lead as per directionof Engineer-in-charge.14.7.1 In cement mortar.
37Part B- Interior works
38Providing, supplying and fixing factory-made acoustic modular metal wall panelling system comprising minimum 0.50 mm thick GMS/galvanized steel or equivalent metal panels, factory finished with approved powder coating/PVC/Polyolefin finish, in approved size, profile, colour and texture, including perforated/non-perforated panels as required.Panels shall be fixed on a properly aligned GI/CRCA/MS supporting framework comprising channels/struts, wall clamps, brackets, clips, spring-T and necessary fasteners/accessories, securely anchored to the existing wall. The system shall include all required trims, corner profiles, junctions, closures, rockwool or equivalent and provisions for services/accessories, with demountable/replaceable panels wherever required.Complete with supply, fixing, framework, accessories, cutting, levelling, alignment, labour, tools and tackles, finished in all respects as per approved drawings and directions of Engineer-in-Charge.Performance: Suitable fire, acoustic, climatic and low-VOC performance as per project requirements.\\" • Fire (Class) – A• Climate (°C, RH) – 50, 90• Light reflectance (%) – 75• Green (VOC, RC %) – Low, 25\\"
39Providing, supplying and fixing full-height frameless modular glass partition comprising 12 mm thick clear toughened safety glass, with minimal aluminium H-section vertical columns/mullions and U-shaped aluminium channels at top and bottom, securely anchored to floor, wall and ceiling. The system shall be modular, replaceable, expandable and flexible, with provision for electrical/data raceways and integration of solid/acoustic panels wherever required. Complete with suitable gaskets, trims, brackets, fasteners, sealant and all necessary accessories, including cutting, fixing, alignment and finishing, complete as per approved drawings and direction of Engineer-in-Charge.
40Providing, supplying, installing, testing and commissioning of 12 mm thick clear toughened glass door, frameless type, with machine-polished edges, complete with SS 304 grade patch fittings, floor spring, top/bottom patch fittings, pull handle, lock, door stopper, gaskets, sealant and all necessary hardware/accessories, including cutting, drilling, transportation, fixing, alignment and commissioning, complete as per approved drawings and direction of Engineer-in-Charge.
41Supply and installation of acoustically transparent FR-grade stretch fabric acoustic wall/ceiling system, comprising concealed GI framework, 15 mm thick magnesite bonded woodwool acoustic panels, 25 mm thick acoustic infill, FR-PVC/vinyl gripper tracks, backing/base, fasteners, adhesives and all necessary accessories, complete as per manufacturer’s recommendations, including stretching and fixing of fabric to provide a smooth, taut and wrinkle-free finish.Minimum Performance: Fire Class-1, NRC up to 0.90, low VOC, suitable for 50°C/90% RH and minimum 25% recycled content.
42Supply and installation of 102 mm thick high water-resistant and fire-resistant magnesia drywall partition system, comprising GI stud/channel framework with two layers of approved magnesia boards on either side, including 18 mm thick core board and 12 mm thick outer board, complete with 50 mm thick cavity insulation of approved material, chicken wire mesh/cross bracing wherever required, suitable metal fasteners, staggered board fixing, jointing with approved seam kit/AJP, sanding, smoothing and primer finish, complete in all respects as per manufacturer’s recommendations and approved shop drawings.The system shall have minimum technical performance of:Fire resistance: Up to 120 minutesAcoustic performance: STC up to 44Termite resistance: YesLow VOC / hygienic finishLight reflectance: Approx. 80%Green/recycled content: Approx. 30%
43Supply and installation of FR-grade, acoustically transparent stretch fabric acoustic wall system, comprising concealed GI framework, acoustic backing/infill, 15 mm thick magnesite bonded woodwool panels, track bases, FR-PVC gripper tracks, adhesives, fasteners and all necessary accessories, complete with stretching and fixing of fabric to achieve a smooth, taut and wrinkle-free finish, as per manufacturer’s recommendations.Minimum Performance: Fire Class-1, NRC up to 0.95, suitable for 50°C/90% RH, low VOC.
44Providing, supplying, installing, testing and commissioning of factory-fabricated metallic door shutter with pressed steel/GI door frame, overall door size upto 3.50 Sqm, comprising suitable gauge/thickness steel sheet shutter with internal reinforcement/stiffeners, suitable infill where required, continuously welded and properly ground construction, factory-finished with approved powder coating/PU paint, complete with heavy-duty hinges, lockset, tower bolts/door bolts, handles, door stopper, required fasteners, anchorages and all necessary hardware and accessories. Door frame shall be of suitable gauge pressed steel/GI section with mitred/welded corners, provision for fixing to masonry/RCC/steel structure, and finished to match the shutter. The complete door assembly shall be plumb, level, rigid, smooth in operation and properly aligned, including transportation, erection, fixing, sealant, touch-up painting and all labour, materials, tools and tackles, complete as per approved drawings, specifications and direction of Engineer-in-Charge.
45Providing, supplying and fixing designer metal baffle ceiling system comprising minimum 0.80 mm thick CRCA/GMS or extruded aluminium baffles, of approved size, profile, module and design, CNC formed/extruded and powder coated with approved colour and finish, having powder coating thickness of 70–80 microns minimum, suspended at approved centre-to-centre spacing (typically 150 mm c/c) from compatible powder-coated CRCA/GI/GMS carrier channels and suspension framework using approved threaded rods, hangers, interlocking clips, nuts, bolts and fasteners.The ceiling system shall include all necessary mother channels, carrier channels, strut framework, suspension components, clamps, end caps, connectors and accessories, complete with self-interlocking/fixing arrangement as required. Provision shall be made for perforated metal strips/panels or matching infill panels between baffles, wherever required, for concealing services and enhancing aesthetics.The complete system shall be accurately levelled, aligned and securely fixed to the true ceiling, including all cutting, drilling, fabrication, fixing, finishing, labour, scaffolding/access arrangements, tools and tackles, transportation and all incidental works, complete as per approved drawings, manufacturer's recommendations and directions of Engineer-in-Charge.The system shall comply with the required fire performance (Class 1 or equivalent), low VOC/green building requirements, and be suitable for the specified environmental conditions. The ceiling shall be of an approved proprietary system or equivalent, with all components compatible with each other and designed to provide a neat, uniform and durable finished appearance. System: Proprietary designer metal baffle ceiling system comprising compatible baffles, carrier/support framework and suspension system, complete as per approved drawings and manufacturer's recommendations.
46Providing, supplying and fixing designer acoustic metal false ceiling system comprising factory manufactured perforated metal ceiling panels of approved size/profile, manufactured from minimum 0.50 mm thick GI/GMS steel sheet, with approximately 20% perforation and backed with black acoustic fleece/tissue, having NRC not less than 0.70, or as approved by the Engineer-in-Charge.Panels shall be square/tegular edged, downward accessible/removable and securely fixed using a compatible GI/GMS powder-coated exposed T-grid/carrier system comprising main runners, cross runners, wall angles, torsion springs/clips, suspension rods/wires, anchor fasteners and all necessary accessories. The suspension system shall be designed as per manufacturer's recommendations and suitable for the required plenum height and service loads.Metal panels shall be factory finished with approved colour using polyester powder coating/coil coating over suitable pre-treatment, providing a uniform, durable and corrosion-resistant finish. The complete ceiling system shall be fire resistant and suitable for Seismic Zone V, supported by valid test certificates from recognized/reputed laboratories and complying with relevant IS/BS standards.The system shall have valid applicable GreenPro/GRIHA/green-building certification and the manufacturer shall possess ISO 9001:2015 certification and demonstrated experience in supplying similar metal acoustic ceiling systems in India.The item shall include complete suspension arrangements, levelling, alignment, cutting and framing/provisions for light fittings, HVAC diffusers/grilles, smoke detectors, speakers, sprinklers and other services, edge trims, jointers, clips and all necessary accessories, labour, tools, tackles, wastage and incidentals, complete in all respects as per approved drawings, manufacturer's specifications and instructions of the Engineer-in-Charge
47Providing and fixing calcium silicate board false ceiling at all heights including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the calcium silicate board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting of thickness of calcium silicate board as below:- 8mm thick
48Providing and fixing Grid type false ceiling of 14 mm thick Acoustical with fine fissured tiles/ Mineral fibre high density tiles with butt edges false ceiling tiles of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge. ( The tiles should of 90 % RH avg. NCR 0.55 light reflectance> 80% thermal conductiveity K = 0.052-0.057 w/m K colour white. Fire performance class 0/class I(BS 476) with warranty against sag)
49SITC of Designer Acoustic Flooring To avoid distraction of operators because of unwanted noise generated from movement of chairs/people in the control/office room it is necessary that the proposed flooring shall damp such impact noises. Acoustic flooring (shall reduce impact sound by 14dB (ISO 717-2)). It shall be twin-layer linoleum built up from minimum 2mm acoustic laminate and a 2mm corkment backing. Flooring shall be decorative type of approved shade, pattern, texture and design and of approved manufacturer. Dimensions shall be as per the final approved design and site requirement. Flooring shall be laid over concrete floor with laying compound strictly as per manufacturer’s specification. The designer acoustic flooring shall be Greenguard gold tested / certified. The necessary certificate / test report valid on the bid date and to be submitted at the time of drawing approvals. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
50SITC of Designer Privacy film for glass partitions & glass door The film to be installed on clear glass to provide the look of sandblasted glass. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
51SITC of manual roll-down roller blinds for windows, comprising approved quality fabric fixed on an aluminium roller tube, with manual operating control mechanism, aluminium powder-coated bottom bar for proper weighting and alignment, including necessary brackets, end caps, fittings, fixing accessories and complete fabric installation. Where required, provision of suitable aluminium top rail/head box shall be provided for improved appearance and concealment of the roller mechanism. Fabric, colour, texture and finish shall be as approved by the Engineer-in-Charge. Complete in all respects as per approved drawings, specifications and direction of Engineer-in-Charge.
52SITC of 3-Seater Sofa The top shall be of Upholstery with PU Finish. The sofas are made of solid wood base, reinforced with supportive addendum in the seat. Engineered wood panels form/support the overall design structure, they synergise with the solid wood to offer unparalleled life to the product. Foam padding of multi- density and varying thicknesses provide cushion for the sofa. PU foam used is made Hennecke foam plants using German Technology capable of producing the high-quality flexible polyurethane foam. It provides unparalleled comfort, ease of use and durability. The foam used is 32 Density for seating areas and 28 Density for backrest. The supersoft foam used is in seating areas in 32-35 Density High-resilience (HR) foam which is unique and rarely used by manufacturers. Webbing: Interwoven high tensile elastic bands for optimum comfort and endurance. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
53SITC of 2-Seater Sofa The top shall be of Upholstery with PU Finish. The sofas are made of solid wood base, reinforced with supportive addendum in the seat. Engineered wood panels form/support the overall design structure, they synergise with the solid wood to offer unparalleled life to the product. Foam padding of multi- density and varying thicknesses provide cushion for the sofa. PU foam used is made Hennecke foam plants using German Technology capable of producing the high-quality flexible polyurethane foam. It provides unparalleled comfort, ease of use and durability. The foam used is 32 Density for seating areas and 28 Density for backrest. The supersoft foam used is in seating areas in 32-35 Density High-resilience (HR) foam which is unique and rarely used by manufacturers. Webbing: Interwoven high tensile elastic bands for optimum comfort and endurance. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
54SITC of Single Seater sofa chair Single Seater sofa chair without Arm, SS Base Stand, Gas Lift, Leatherette Tapestry. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
55SITC of Center unit (Type 1) 1. Centre unit for sofa, toughened glass, 12mm thick, chrome plated pipe frame. 2. Approximate minimum dimensions – 1200mm(W) X 600mm(D) X 450mm(H) Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
56SITC of Chair Type 1 High Back with Mesh Backrest, Adjustable Armrest, Gaslift for seat height adjustment, Standard 5-prong nylon base, Seat: Fabric, Backrest – Mesh Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
57SITC of Chair Type 2 Medium Back, Mesh Back, Silver Epoxy Backbone, Synchronized Mechanism, 3-Way Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong nylon Base, Seat - Fabric and mesh backrest. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
58SITC of Chair Type 3 Low back visitor model ABS for seat, Mesh back with extra lumber Support with fine tuning for depth adjustment, with fixed armrest, silver epoxy cantilever base Upholstery: Black Fabric Seat & mesh backrest. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
59Providing, supplying and installing linear workstation desk of approximate size 900 × 600 × 750 mm (W×D×H), comprising 25 mm thick E1-grade pre-laminated particle board tabletop with matching edge banding and aluminium flip-up cable access. The structure shall comprise 40 × 30 mm CRCA powder-coated beams, sharing cable tray of approximately 300 × 120 mm, triangular perforated CRCA powder-coated modesty panel and powder-coated aluminium die-cast slant legs/CRCA concealed legs of suitable sections. Complete with removable 18–25 mm thick fabric acoustic panels with aluminium frame, having acoustic performance up to NRC 0.70, serving as privacy/acoustic screens. Including cable management, electrical/data provisions, brackets, connectors, fasteners and all necessary accessories, complete in all respects as per approved design and direction of Engineer-in-Charge.
60Providing, supplying and installing metal storage cabinet of approximate size 900 × 450 × 1200 mm (W×D×H), fabricated from minimum 0.8 mm thick CRCA steel sheet, duly powder coated for durability and corrosion protection. Cabinet shall be provided with openable hinged metal shutters with concealed/recessed handles, cam-locking arrangement with individual keys and height-adjustable shelves suitable for storage of files, documents and office materials. Complete with all necessary hinges, shelves, locks, fittings, fasteners and accessories, including fabrication, assembly, transportation and installation, complete as per approved design and direction of Engineer-in-Charge.
61Providing, supplying and installing executive cabin desk with side/back runners, comprising 25 mm thick pre-laminated MDF/particle board tabletop with matching edge banding and flip-up cable access, supported on powder-coated CRCA/MS framework and tapered die-cast aluminium legs. The desk shall include a powder-coated perforated CRCA modesty panel and integrated storage units with 18 mm thick pre-laminated board, drawers/shutters and suitable handles. Complete with cable management, brackets, hardware, fasteners and all necessary accessories, including fabrication, assembly, installation and finishing, complete as per approved design and direction of Engineer-in-Charge.Approx. Table Size: 2100 × 1000 × 750 mmSide Runner: 900 × 450 × 750 mmBack Runner: 2100 × 450 × 750 mm
62Providing, supplying and installing open collaborative conference/meeting table of approved design, suitable for 4 to 13 persons, comprising 25 mm thick pre-laminated particle board (PLPB) tabletop with matching edge banding, rounded edges and aluminium flip-up cable access/power provision. Table shall be supported on powder-coated CRCA/MS structural framework and PLPB gable legs, with suitable modesty panel and integrated cable management trays. The table shall be self-standing, ergonomically designed and complete with necessary brackets, fasteners, electrical/power provisions and accessories, including fabrication, assembly, installation and finishing, complete as per approved drawings and direction of Engineer-in-Charge.Approx. Size: As per approved design (up to 5200 × 1800 × 750 mm)
63Providing, supplying and fixing digitally printed self-adhesive vinyl poster/graffiti graphics on walls, panelling surfaces and Sunboard surfaces, comprising high-quality, UV-resistant vinyl film of approved thickness and finish, digitally printed with approved graphics/design in high resolution, including printing, surface preparation, adhesive application/self-adhesive backing, providing and fixing 5 mm thick Sunboard/PVC foam board, mounting/fixing of printed vinyl on Sunboard, alignment, cutting, trimming, edge finishing and installation, including matte/gloss lamination wherever required, complete with all materials, labour, tools, accessories and necessary supports/fixtures, as per approved design and directions of the Engineer-in-Charge.Make: 3M or equivalent approved make.
64Providing and fixing ceramic writing board of size upto 2400 × 1200 mm, comprising high-quality ceramic-coated writing surface fixed on 12 mm thick plywood backing, with 25 × 40 mm beechwood/approved wooden beading frame all around, duly polished/finished. Complete with suitable wall fixing arrangements, concealed fasteners, corner joints, edge finishing and all necessary accessories, including labour, tools and tackles, complete as per approved design and direction of Engineer-in-Charge.
65Providing, supplying and fixing of AISA Logo of approximate size 1000 × 1000 mm, fabricated from laser-cut high-grade AISI 316 stainless steel, with smooth edges, brushed/mirror finish as approved, including necessary backing/support, concealed fixing arrangement, SS hardware, templates, cutting, fabrication, polishing, transportation, installation and all necessary accessories, complete as per design/details provided by the Engineer-in-Charge.
66Providing, supplying and fixing wall poster of size 2' × 3' (600 × 900 mm), comprising 3 mm thick clear acrylic sheet with high-resolution UV printing in mirror/reverse impression on rear side, with white backing layer for enhanced opacity and colour, fixed on wall/panelling using 3M or equivalent high-strength double-sided adhesive tape, including surface preparation, cutting, finishing, fixing and all necessary materials, labour and accessories, complete as per approved design and direction of Engineer-in-Charge.Unit: Each
67Providing, supplying, printing and fixing main exterior signage board comprising 3 mm thick ACP sheet mounted on 1.5\\" × 1.5\\" MS square pipe frame with suitable heavy MS angle supports, duly fabricated and painted. The signage shall display AISA Logo in embossed 3D acrylic letters, with remaining text/matter in 3 mm thick black and red acrylic cut letters (non-illuminated), as per approved design. The item shall include MS framework, ACP cladding, acrylic letters/logo, printing, fabrication, transportation, erection, fixing, necessary hardware, supports and all labour, complete in all respects as directed by Engineer-in-Charge.
68Providing, supplying and fixing inaugural plaque comprising 3 mm thick black acrylic sheet of approved size, with golden acrylic/metallic finish letters and logo, laser/CNC cut and fixed neatly on the plaque, including backing/support, adhesive/concealed fixing, edge finishing, cutting, fabrication and all necessary accessories, complete as per approved design and direction of Engineer-in-Charge.
69P & F PVC Storage Tank ISI Marked (IS : 12701) indicatingthe BIS license No), of approved make with cover, 25mm dia1M long G.I. over-flow pipe & 25 Cm. long wash out pipewith plug & socket, including making connection etc.,complete of approved design 500 ltr capacity
70Providing, supplying and fixing modular office cabin name plate of approved size, comprising aluminium/acrylic frame with interchangeable/replacement name strip or sliding insert, allowing easy change of occupant/name without dismantling the complete plate. Name insert shall be provided with UV-printed/engraved lettering on acrylic/PVC sheet, with suitable wall mounting arrangement, SS screws/spacers, end caps and all necessary accessories, complete as per approved design and direction of Engineer-in-Charge.
71Providing, supplying and fixing rectangular water/door mat made of durable Polyvinyl Chloride (PVC) material, in approved grey colour, with anti-skid and water-resistant properties, suitable for entrance/doorway use, including cutting, laying/fixing and all necessary accessories, complete as per approved quality and direction of Engineer-in-Charge.
72Providing all Drawings, Architectural, Structural & MEP Consultancy Services for AISA, Bharatpur, including preparation and revision of site/layout plans, architectural, structural and working drawings, and MEP designs/drawings covering electrical, HVAC, fire-fighting, plumbing, drainage, ELV/ICT and allied services, along with necessary coordination, technical support and submission of drawings in CAD/PDF formats. The consultancy services shall also include necessary revisions, modifications and technical support until the final As-Built Drawings are prepared, updated and duly finalized, incorporating all site-level changes and executed works.
73Part C- Road, Culvert & Compound wall
74Providing and laying Brick work with common burnt clay bricks of class designation 7.5 in superstructure above plinth level upto all floor in all shapes and sizes in : Cement mortar 1 : 4 (1 cement : 4 coarse sand) (the rate is inclusive of work upto all floor level including scaffolding & double scafloding )
75Plaster on new surface on walls in cement sand mortar 1:4including racking of joints etc. complete fine finish
76Finishing wall with water proofing cement paint of approvedbrand and manufacture and or required shade to give an evenshade including all scaffolding: New work (Two or more coats applied @ 3.84 kg/10 sqm).
77Providing and fixing steel gate, grating , and grills made ofangles, tees, square bars, flats,or black pipe with holdfast andfittings complete as per design and drawing including cuttingwelding and fabrication with priming coat of red oxide
78Providing and fixing cow catcher made of R.S. joist angleschannels MS rounds including cutting welding and fabricationwith priming coat of red oxide (as per design).
79Earth work in excavation by mechanical means (Hydraulicexcavator )/ manual means over areas (exceeding 30cm indepth. 1.5m in width as well as 10 sqm on plan) includingdisposal of excavated earth, lead upto 50m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed : All kinds of soil
80Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate20mm nominal size).
81Random Rubble stone masonry for with hard stone infoundation and plinth in Cement Sand mortar above 30 CMthick wall in:Cement Mortar 1:4 ( 1-Cement : 4-Sand).
82Centering and Shuttering with plywood or steel sheetsincluding strutting, propping bracing both ways and removalof formwork for foundation , footings, strap beam, raft , basesof columns etc.
83Providing and laying damp-proof course with cement concrete gradeM-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proofcompound complete as per specification . 50mm thick.
84Providing and laying in position Ready mix concretemanufactured in fully automatic Batching Plant andtransported to site in transit mixer for having continousagitated mixer, manufactured as per approved mix design ofspecified grade of RCC work including pumping of R.M.C.from transit mixer to site of laying , exculding the cost ofcentering, shuttering and reinforcement with all lead and liftincluding cost of admixtures in recommended portion as per IS9103 to accelerate/ retard setting of concrete, improveworkability without impairing strength and durability as perdirection of Engineer in charge. All works upto floor V floorM20 grade Design Mix by using cement as per codalprovision.
85Filling available excavated earth (excluding rock) in trenches,plinth side of foundation etc. in layers not exceeding 20 cm. indepth, consolidating each deposited layer by ramming andwatering including lead up to 50 meter and with all lift
86Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300-1 and 300-2 for subgrade construction as per MoRTH Specification Clause 305.3.4
87Providing, supplying and transporting approved graded sandy soil suitable for road embankment from approved source, including excavation, loading, transportation, unloading, spreading and all leads and lifts, complete as per MoRTH specifications and as directed by Engineer-in-Charge CBR > 6
88Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300-1 and 300-2 with a lead upto 50 m as per MoRTH Specification Clause 305.3
89Providing laying spreading and compacting specified graded sand, gravel (crushed stone) as per Table 400-1,400-2 or any other course material as per design mix, as per CBR in sub base course including premixing the material at OMC in wet mix plant, carriage of mixed material spreading in uniform layers with motor grader F.E loader on a prepared base and compacting with vibratory roller to achieve desired density (as per I.S.2720) including all material, labor, machinery, lighting guarding, barricading and maintenance of diversion complete.[MoRTH specification : Clause 401]. By mechanical meanswith a lead of 1 Km. for garding I
90Providing and laying of paver block as per IS 15658 : 2006(Indian standard for precast concrete block for pavingspecification)and IRC : SP:63-2004 (guidelines for the use ofinterlocking concrete block pavement) M-35,60mm thick to be used in light traffic (Light traffic isdefined as a daily traffic up to 150 commercial vehiclesexceeding 30 KN laden weight, or an equivalent up to 0.5million standard axles (MSA) for a design life of 20 years (Astandard axle is defined as a single axle load of 81.6 KN) likepedestrian plazas, shopping complexes ramps, car parks, officedriveways , housing colonies, office complexes, rural roadswith low volume traffic, farm houses , beach sites, touristresorts, local authority footways, residential roads, etc.(A) Category A Denated units to key into each other on four faceszigzag shape as per IRC SP 63:2004
91Supply & fixing of M-20 grade precast cement concrete Kerb or Dand upto 60 cm length over 20 mm thick base of cement mortar 1:6 including jointing earth work, pointing & jointing withcement mortar 1:4 of size (20 x 25) x 30 cm
92Clearing jungle including uprooting of rank vegetation, grass,brush wood, trees and saplings of girth upto 30 cm measuredat a height of 1 m above ground level and removal of rubbishupto a distance of 50 m outside the periphery of the areacleared.
93Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 2905. 1200 mm Dia
94Supplying,fitting,andplacingHYSDbarreinforcement(PrimarySteel)inFoundation,SubstructureandsuperstructureatanylevelcompleteasperdrawingandMoRTHspecificationsClauses 1009,1600 and 2302
95Pre Cast U/Semi circular Drains (Outer size 600x400 mm,wall thickness 80 mm)Providing and fixing Precast concreteUdrains (M-30 Grade) ofdifferent sizes (Manufactured with fully mechanised dry castprocess with forced action mixer whose arms revolve alongthe main axis and rotate about its own axis also, havinghumidity sensor for moisture control of w/c ratio in concretemix. Manufactured with Steel moulds (Milled andmanufactured in CSI diamond or CSI Nitro process foraccuracy) on steel base plate of min 16 mm thick; HavingVibration and pressing action both together with the help ofmultiple synchronised vibrators. Power of hydraulic stationshould be minimum 50KW for compaction and cured incontrolled chambers having humidity control and automatedair circulation system) including hoisting and setting inposition with cement mortar 1:3 (1 Cement : 3 Coarse Sand),cost of required centering, shuttering complete and spreading25mm thick sand underneath.
96Supplying and Filling in plinth with river sand under floorsincluding watering ramming consolidating and dressingcomplete including cost of sand
97Part D- Washrooms work
98Providing and fixing 1st quality Heavy Duty Vitrified Glazed MAT tiles on floor, skirting and steps, minimum 10 mm thick, water absorption ≤0.08%, conforming to IS 15622, laid with 20 mm thick cement mortar 1:4, including grouting of joints with white cement and matching pigment, complete.
99Providing and fixing 1st quality standard glazed ceramic tiles conforming to IS 13753 & IS 15622, size 200 x 300 mm, on walls etc., laid on neat cement slurry and finished with flush pointing in white cement mixed with matching pigment, complete (excluding cement plaster).
100Providing and laying waterproofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like, including cement slurry with waterproofing compound, 20 mm cement plaster 1:3, bitumen treatment and 400 micron PVC sheet, including rounding of junctions, complete.
101Providing and fixing superior quality CP brass single lever wash basin mixer with 450 mm long copper connection pipe, complete.
102Providing and fixing premium quality low level flushing cistern of 10 litres capacity PVC with PVC bend as per IS 7231, complete.
103Providing, supplying and fixing urinal flushing arrangement comprising approved quality CP brass/SS flush valve or sensor-operated automatic flushing system, including flush pipe, spreader, control valve/sensor, necessary connectors, brackets, isolation valve and all required plumbing connections, fittings and accessories, complete in all respects as per approved design and direction of Engineer-in-Charge.
104Providing and fixing CP health faucet with 1 m long tube and hook, complete.
105Providing and fixing plain floor trap, 110 mm dia, complete.
106Providing and fixing Nahani trap with jali, 4 inch/110 mm dia, complete.
107Providing and fixing premium quality bottle trap, 32 mm internal portion, 250 mm long wall connection pipe and wall flange, complete.
108Providing and fixing superior quality CP brass angular stop cock with long thread, 15 mm nominal size, complete.
109Providing, supplying and fixing toilet cubicle partitions of approved make and design, comprising compact laminate/compact HPL panels of suitable thickness, including aluminium/SS supporting framework, pilasters, head rails, adjustable legs, brackets, hinges, stays, locks, handles and all necessary hardware and accessories. Panels shall be moisture-resistant, scratch-resistant and suitable for toilet/wet-area application, complete with cutting, fabrication, fixing and finishing as per approved drawings and direction of Engineer-in-Charge.
110Providing, supplying and fixing toilet cubicle door of approved make and design, comprising compact laminate/compact HPL panel of suitable thickness, complete with SS/aluminium hinges, indicator bolt/latch, handle, coat hook, door stopper, fixing brackets and all necessary hardware and accessories, including cutting, fabrication, installation and finishing, complete as per approved drawings and direction of Engineer-in-Charge.
111Providing and fixing factory-made P.V.C. door frame of size 50 × 47 mm, with 5 mm wall thickness, made of extruded rigid PVC foam sheet, mitred and joined at corners, with MS brackets and 19 × 19 mm MS reinforcement, EPDM rubber gasket and necessary fixing screws, complete as per manufacturer's specification and direction of Engineer-in-Charge.
112Providing and fixing to existing door frames 30 mm thick factory-made solid panel PVC door shutter, consisting of MS tube frame, PVC C-channel framing, PVC sheet panelling, lock rail, top and bottom rails, solvent-cement joints and all necessary fittings, complete as per manufacturer's specification and direction of Engineer-in-Charge, for W.C. and bathroom door shutter..
113Providing and fixing automatic hand dryer of approved make and suitable capacity, complete with electrical connection and mounting accessories.
114Providing and fixing stainless steel sanitary waste bin of approved size and quality, complete.
115Providing and fixing CP brass twin peg/coat hook of approved quality, complete.
116Providing, supplying and fixing complete set of accessibility accessories for accessible toilet, comprising SS 304 support rails, toilet paper holder, robe/coat hook, door safety fittings and other necessary accessibility accessories, including brackets, fasteners, wall fixing and installation, complete as per approved drawings, accessibility guidelines and direction of Engineer-in-Charge.Make: CERA / Jaquar / Hindware / Kohler or equivalent approved make
117Providing and fixing 3-layer PP-R pipes SDR 7.4, UV stabilised and antimicrobial, fusion welded, including PP-R plain and brass threaded fittings, clamps at 1 m spacing and testing of joints; concealed internal work including cutting chases and making good, 20 mm OD PN-16.
118Providing and fixing rigid PVC Pipe (IS: 4985 marked), Class-II (4 kg/cm²), of approved quality/make, including joining the pipe with solvent cement, rubber ring and lubricant, complete as per direction of Engineer-in-Charge.110 mm dia
119The BSR description is rigid PVC pipe, IS:4985 marked, Class-II (4 kg/cm²), including joining with solvent cement, rubber ring and lubricant. 160 mm dia
120Providing and fixing rigid PVC vent pipe of approved quality including necessary fittings, clamps/supports and vent cowl, 75 mm dia, complete.
121Providing and fixing floor drain waste connection including required PVC pipe, fittings, jointing material, clamps and connection to soil/waste line, complete.
122Providing and fixing water supply connection to sanitary fixture including required PPR/CPVC pipe, fittings, valves and connection complete.
123Testing and commissioning of complete internal plumbing installation including pressure testing of water-supply lines, leakage testing of waste/soil lines and rectification of defects, complete.
124Providing and fixing sealant, sleeves, clamps, supports, hangers and miscellaneous plumbing fittings/accessories required for complete installation, including fixing and making good, complete.
125Providing, cleaning and repairing existing septic tank, including removal and disposal of accumulated sludge/sewage by suitable mechanical/manual means, cleaning and washing of tank, removal of deposited silt, minor repairs to internal plaster/masonry/concrete surfaces, repair/replacement of damaged inlet/outlet connections, sealing of leakage points, making good of joints and surfaces, cleaning of inspection chambers/manholes and disposal of waste at approved location, complete in all respects as per site condition and direction of Engineer-in-Charge.
126P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge
127Oval shape 450x350 mm
128P & F Liquid Soap Container with brackets complete of approved make:
129Synthetic Material of approved quality/make:
130P & F lst quality WVC Urinal (IS:2556 mark) with 25mm diaG.I. waste pipe, dome waste couplings, concealed ironbrackets or screws etc complete.Mini stall size 455x385x350mm
131P & F White Vitreous China Double Syphonic EuropeanW.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of(IS : 2556 Mark) of 10 litre capacity complete with allnecessary internal fittings including cutting and making goodthe wall and floor.
132P & F WVC Wash basin (Ist quality IS:2556 Mark) ofapproved make with C.I. brackets duly painted 1 No. 15 mmC.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass wastecoupling of approved make, P.V.C Waste pipe with PVC nut32 mm complete including cutting & making good the wall : Size 610 mm x 510 mm
133Part E- MEP Works
134Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling & heating, having 100% hermetically sealed inverter type twin rotary/Scroll Compressor(s) with and minimum two compressors , above 14 HP modules, microprocessor based Controller, Side / top discharge type condensing unit(s), with R-410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The EER/COP (W/W) at 100% load with AHRI conditions shall not be less than 3.8 etc. complete as required.
13514 HP to 26 HP
136Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down valve in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor).
1372.4 TR (Cooling Capacity 8700 Watt)
1384.0 TR (Cooling Capacity 14000 Watt)
139Supply, installation, testing and commissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 with 7 mil Glass Cloth and 3 coats of anti UV paint (on area which is exposed to weather) including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes.
14028.6 mm O.D., wall thinkness ≥ 1.2mm (insulation – 19 mm thick)
14115.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
14212.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
1439.5 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
144Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes.
14525 mm
14632 mm
14740 mm
148Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with and comfort washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down valve in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor)
1491.6 TR (Cooling capacity 5600 watt)
1502.0 TR (Cooling capacity 7000 watt)
151Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes.
15225 mm
153Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler with hermetically sealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick) and tank (0.5 mm thick) , stainless steel water tray,minimum two nos Brass Chrome plated faucets and suitable drainage system complete in all respect with required height MS fabricated and Painted Angle iron frame ( Cost of frame to be paid Extra )complete in all respect of the following capacity.
154cooling capacity 40 Ltr./Hr. and storage capacity 80 Ltrs
155SITC of RO water system with Filteration stages = Particilate filter- Membrane life enhancer filter- sediment filter- pre carbon filter- RO membrane filter- post carbon filter. Input power rating -230V AC, 50Hz, percentage of rejection TDS-90% or better, having following features (a) Double purification by RO with ESS or latest technology with TDS indicator. (b) Spin welded RO membrane housing to prevent tempering. (c) Push fit component for leak proof performance. (d) Fully automatic operation with auto start and auto off. (e) SS/ABS construction for corrosion free lifespan. (f) Equally suitable for water from all borewells, overhead storage tanks, water tankers and even municipal taps. (g) RO membrane flushing - Auto flush@ every start, every stop and every one hour of working for one minute, complete in all respect with following capacity.
156Purification capacity - 50LPH, duty cycle 270-500 liters/day
157Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required.
158Short point (up to 3 mtr.)
159Medium point (up to 6 mtr.)
160Long point (up to 10 mtr.)
161Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.
162On board
163Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required.
164S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required.
16520 mm
16625 mm
16732 mm
16840 mm
169Supply and fixing following size of Pre Galvanized (275 GSM) floor raceways / Under floor trunking with/ without partion, including common cover, joint sleeve, cross over junction Box etc. as required.
17075 mm x 38 mm x 1.5 mm
171Supply and fixing following Pre Galvanized (275 GSM) Adjustable Junction Box for floor raceways / Under floor trunking etc. as required.
172Junction Box 200 mm x 200 mm x 40-75 mm with Galvanized Lid
173Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.
1743x 1.5 sq.mm
1752 x 2.5 sq. mm. + 1x1.5sqmm
1762 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
1774 x 10.0 sq.mm
1784 x 16.0 sq.mm
1792 x 6.0 sq.mm
180DISTRIBUTION BOARDS
181Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required.
182Single pole MCB (With B / C curve tripping characteristics)
1836 A to 32 A rating
184Double pole MCB (With B / C curve tripping characteristics)
1856 A to 32 A rating
186Triple pole MCB (With B / C curve tripping characteristics)
18740 A rating
18850/63 A rating
189Four pole MCB (With B / C curve tripping characteristics)
19050/63 A rating
191Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 25 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.
192Two pole 100/300mA sensitivity
19340 A rating
194Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed / Acrylic) Distribution board with Metal end box made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, complete with 100 amp. insulated copper bus bar/shorting link , brass neutral link with shrouds, brass earth link , door earthing arrangement, color coded interconnecting wire set of minimum 10.0 sqmm size and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required.
195Metal door (single phase) IK-09 and IP-43 with Metal end box
19616 Way
197Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box
1986Way {8 Incomer + 6 Sub Incomer (2+2+2) + 18 out going }
199Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB up to 63 Amps. as outgoing ,made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with insulated 125/160/200/250 Amp. copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required.
200Double door IP-43 & IK-09 with Provision of Incomer MCCB up to 125 A Rating with Metal end box
2016 Way
202SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate.
2034 pole MCCB With Thermal Magnetic release
204125 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
205Lighting
206SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmissivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
207Recessed Mounting
208Minimum lumen output 4320 lm
209SITC of IP-20 LED Recessed / Surface Mounted, Round / Square backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS compliance 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
210Recessed Mounting
211Minimum lumen output 1600 lm
212Minimum lumen output 1950 lm
213EARTHINGS
214SITC of Copper Bonded rod Earthing with high tensile strength (more than 600 N / sq.mm low carbon steel rod molecularly bonded with Copper thickness (250 microns) and confirming to UL 467 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :-
215(a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole
216(b)Earth enhancing compound to ensure the moisture content and electrical conductivity, 25 kg for 3000 mm. The compound shall be tested form NABL accredited lab for low resistivity (less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content in accordance with IEC 62561-7
217© Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt
218(d) Place Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm.
219(e) Testing of earth resistance for value of 5 ohms or less as required.
220(f) Test certificates for confirming above standards from OEM is mandatory.
22125 mm thick and 3 Mtr. Long
222Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.
223Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required.
2248 SWG tinned copper Wire
2258 SWG G.I. ( Hot Dipped ) Wire
226Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping double the width of strip and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.
22725mm x 3mm copper strip
228CABLING WORK
229Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.
2306.0 Sq. mm
2312 core
23295.0 Sq. mm
2333.5 core
234Providing & Fixing of 400 mm Sweep BLDC technology Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Double Wall bearing with front and back 120 or more ribs guard; Three no. blades, noise level should be <= 75 dB, including fixing with anchor bolts, making connection testing etc. as required. ( With Remote )
235Wall mounting type with Service value 2.0 CMM /W, Min. Air Delivery 71 CMM
236Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.
237150mm x 50mm x 1.6mm
238SITC of following capacity BIS certified (if applicable) 3Phase Input, 1Phase Output Online double conversion VFI-SS-111 IGBT based UPS (Rack/Tower 3U) with 0.99 Input power factor & unity Output factor(KVA=KW), having Input side Internal / External Isolation Transformer, voltage & frequency range of 305-485V & 40-70 Hz and output voltage & frequency of 230V+/-1% & 50 +/- 0.1 Hz.UPS should have EPO,dust filter & conformal coated boards, Overall efficiency of upto 96% at rated voltage & frequency, Overloading of < 105% continious,106-110% 60 mins, 111 - 130% 10 mins,131 - 155% 1 min, THDv of < 1% for Linear & < 3% for Non linear load.UPS should have LED Panel with Auto rotating LCD display showing real time UPS status with other parameters like Input, Output, Bypass - Voltage/ Frequency/Current, Output -VA/W/power factor/load percentage, Battery -Voltage/ Current/Status of charge/Remaining backup time percentage/ Self test.UPS should have protection from Input High / Low; Over Load;Short Circuit; Over Temperature and give audible alarms on Battery Mode;Low Battery;Fault;Over Load & Bypass Mode.UPS Monitoring through communication port RS 485. SMF Batteries for 30 min back up with MS Rack and necessary cable for UPS to Batteries Installation. UPS should have CE, ROHS, IEC62040-1,2&3 compliance and should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location Etc. as required.
23920KVA UPS with 20160 VAH Battery
240LAN Services:
241DATA ,CCTV & TELEPHON WORK
242SITC of IP Based 5MP Dome camera: 1/2.8\\" or larger Progressive Scan CMOS Sensor with resolution:(2560 x 1920) @30 fps. Should Support H.264, H.265, MJPEG, Quad/Triple streaming profiles, Frame rate upto 1-30 fps, 120dB WDR, 2DNR/3DNR, BLC. Camera should support Open standard to support ONVIF (PROFILE S, PROFILE G, PROFILE T), 1/1 Audio In/Out or better and 1/1 Alarm In/Out or better, onboard storage upto 512GB (SD card not included). The camera supports advanced Video Analytics (VA) including motion detection, and alarm should be trigger on Tampering, Network disconnect, IP address conflict. CCTV should have password protection, privacy mask, IP address filtering, Metal Housing, Vandal-proof housing, IP67, IK10, DC 12V & PoE, Complete with Junction box for cable management. Operating Conditions within -20°C to 60°C or better. The MAC address of Camera/NVR must be registered in the name of OEM. Regulatory approvals include FCC, BIS/UL, CE. CCTV cameras must be BIS Registered Cyber Security Certified by STQC as per IoTSCS and meet the Essential Requirement (ER) issued by MeitY for security. The CCTV OEM should have its service/ support center in Rajasthan.
2432.8/3.6/4 mm lens with 30 meter IR range
244SITC of 3.5\\" 4TB internal HDD for cctv recording ,capable for 24x7 operation, hdd rpm capacity shoud be 7200 rpm or better, Buffer should be 512 MB as required of following size.
245SITC of 8CH NVR for 2/5/8 MP cameras with minimum 1 SATA HDD Support with minimum 10 TB Capacity (minimum 10TB Capacity per slot - Hard Disk Not Included), minimum 1 HDMI output port, Video comression - H.265/H.264/JPEG, 1/1 Audio In/Out. NVR should support minimum 80 Mbps throughput bandwidth (40 Mbps incoming bandwidth), ONVIF compliance (Profile S/G/T). Recording resolutions up to 4K/8MP, minimum 2 USB Ports, minimum 1 Ethernet Ports (RJ-45) 10/100/1000Mbps. The system shall operate in 0°C to +50°C or better with BIS, FCC, CE. The CCTV OEM should have its service/ support center in Rajasthan.
246Supply & Installation of IP-20 & IK-08 , Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\\" angles with wall mounting provision on wall. Accessories like: 1 No of 19\\" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19\\" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.
2479 U Rack with Width 600 mm & Depth 400 mm + 100 mm
24815 U Rack with Width 600 mm & Depth 400 mm + 100 mm
249Supply, Installation, & Testing of 19\\" 1U Rack Mounted/ surface mounted aluminum/ CRCA powder coated, OS2 Single mode glass Fiber Optic Cable Patch panel/LIU loaded with flangeless/screwable duplex adapters for SC/LC/SN/CS type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleeves, screws, nuts to install the panel for rackmount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge.
25012 Ports
251Supply, Installation, & Testing of Indoor duplex Singlemode patch cord (9/125 µm (OS2) made of glass fiber optic with LSZH jacket, F8 2.0x4.1 mm, yellow, singlemode G652.D (9/125 µm (OS2) Mounted on both sides with SC/LC/SN/CS type Duplex connectors in acc. with IEC 61754-20. Zirconia (ceramic) ferrule with a PC polished endface geometry, connectors should be tuned in accordance with IEC 61755-3-1 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment, duplex clip and white plastic dust cover, should comply to delta IL < 0.2 dB after 500 mating cycles, there should be an optional Visual coding, mechanical coding and lock protection on the patch cords which can be added on later stage. patch cords's performance should be acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, as per requirements.
252Single Mode Patch Cord 3 Mtr.
253Fiber Fusion Splicing with OTDR/OLTS Testing of Fiber Single/ Multi mode (per splice) of glass Fiber Optic Cable including jointer box and cleaning the cable and making splice as per standard practice complete in all respect.
254Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required.(For Each SM Fiber) all switches & related Fiber modules should be of same make & category for seamless integration with each other of Enterprise class.
25510 G SFP + Single Mode/Multi Mode
256Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).
257Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord
2581 Mtr
2592 Mtr
260Supply, Installation, Testing and Commissioning of Rack mounted 19\\" 1U, 24 Port loaded, CRS chasis, powder coated, sheet steel, High-impact, flame retardant, thermoplastic, UL Listed, Modular Patch Panels with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required. All as per pre approved by Engineer in charge.
261Modular Patch Panel Loaded with Cat -6 I/O
262Supplying, installation, Testing and commissioning of following capacity 24 port POE Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snooping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.0Ǫ,Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snooping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.0P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.0p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.0ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
263Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, U/UTP (Unscreened/Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by LSZH Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies ranging from 250 to 500 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect.
264Supply and Installation of unshielded/360 degree shielded PCB based Information outlets made of high impact plastic body with ABS, Flammability rating UL 94 V-0 with provision for protection against dust in jack or Faceplate, suitable for Cat 6/6A application complying to latest amendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat 6/6A standards at frequencies 250/ 500 MHz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have toolless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA 568 C.2 & ISO/IEC 11801 or latest standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocol (VOIP) Specifications in existing modular/MS Boxes along with necessary connections as required. All as per pre approved by Engineer in charge.
265Cat 6, Un-sheilded Information Outlet
266SITC of following diagonal size professional Display, 4k Resolution, Brightness(Typ.) 440 nit and above , Contrast Ratio-2000:1 and above, Viewing Angle(H/V)-178/178, Response Time(G-to-G) 8ms, Input: RGB- Analog D-SUB, Video- HDMI 2.0 (2), HDCP- HDCP 2.2, Audio- Stereo mini Jack, USB- Only F/W upgrade, Outputs: RGB- DP1.2(Loop- out), Audio- Stereo mini Jack, External Control- RS232C(in/out), RJ45, External Sensor Detachable type(IR Ambient). Operation Hour 24/7. mounting bracket etc. as required.
267Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC type Fire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM / External NABL Accrediated Lab is to be submitted.
268SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-
269(a) Thickness of CRCA sheet shall not be less than 1.6 mm upto 450 mm length/ width of any compartment and be 2.0 mm above 450 mm, load bearing structure shall be 2.0 mm thick sheet supported by base M.S. channel if required, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided
270(b) complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side(Inner & Outer side) of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.
271[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )
272(d) Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.
273(e) All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.
274(f) Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )
275(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.
276(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI type Test certificates for Temp. rise test, Short circuit test for 50 kA and IP test is to be submitted)
277Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator, with short circuit withstand capacity of 31 MVA for 1 Sec. , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves.
278Electrolytic grade Aluminium bus bar 6010 grade
279Providing & Fixing of IS: 13875 & IEC :61326/IEC:62053-22 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT opertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.
280Three phase AMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS Meter
281SITC of wall type following zone (each zone accessing minimum 20 units (detectors/ devices )) Conventional Type microprocessor based with LCD display EN / LPCB/ UL listed / approved main control panel fabricated from 16 SWG CRCA sheet steel sealed maintenance free (SMF) batteries of min2X7AH of 12 V or as required.including the cost of all accessories, Etc. as required.
2822 Zone
283SITC of EN / LPCB/ UL certified conventional type Hooter cum strobe rated 80 dB 3 mtr. for audible annunciation and 115 cd flashing at 1 Hz for visual Indication including the cost of all accessories,Etc. as required.
284SITC of EN / LPCB certified conventional photo thermal multi criteria detectors of photo-optic sensing chamber, 12 / 24 volt D.C., visual alarm indicator (LED's) \\"Blink \\" in stand by and \\"Steady - red\\" in alarm complete in all respects with base as required.including the cost of all accessories Etc. as required.
285SITC of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output only at CW (5700K to 6500K) , internal surge protection of 4.0 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
2861170mm(+/-10%) LED batten with min. lumen output 2200 lm
287Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass with suitable lenses on LED / integrated lens diffuser to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated metal case potted driver as a unique BIS R number (as per IS 15885) having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate(Fitting & driver both have separate BIS R number). The System level Luminaire efficacy >=130 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , LED driving output current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K as required.
288High Power LED Flood Light Minimum lumen output 6500 lm
289Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. .
290P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra).
291110 mm
292Supply, Fabricating & installing following sizes of perforated Powder coated MS cable tray with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.
293150mm x 50mm x 1.6mm
294Providing & Fixing of ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required.
295250 mm sweep Minimum Air Delivery 750 Cum / hour
296Supply , Installation , Testing and commissioning of 4 MP Varifocal Bullet Network Camera -1/1.8'' Progressive Scan CMOS, 2680 ×1520 at 25fps, 2.8 to 12 mm Varifocal Auto iris lens, 0.001 Lux at F1.2, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), Support H.265, H.264, MJPEG, 140db WDR, BLC, HLC, Defog, EIS, Distortion Correction, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 50m, Support on-board storage up to 256 GB (SD card not included), Alarm : 2 inputs & 2 outputs, Audio: 1 input & 1 output, IP67, IK10, Edge Analytics- Line crossing detection, Intrusion detection, Scene change detection, Audio exception detection, Defocus detection, Motion detection, Face Recognition, Hard Hat Detection, Face Counting, Queue Management, audio exception detection, Video tampering, Region entrance detection, Region exiting detection, UL, FCC, CE certified. as per detail specifications and Preferred makes enclosed in rfp
297Providing & Fixing of IK07 IP65 protected Top/Bottom mounted LED Post top Luminarie top & bottom made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with powder quoted reflector. The System level Luminous efficacy ≥ 80 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . LED Driving output current <750mA as required.
298Minimum lumen output 3200 lm Post top Luminarie
299Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required.
30040 mm Dia.
301Providing & Fixing of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes.
302250 x 200 x 115 mm
303SITC of Radiator Cooled Silent DG Set (As per latest CPCB-IV+ emission norms) having specifications as per A, B, C, D, E, F & G :
304A) Diesel Engine : Turbo charged Diesel Engine ( conforming to BS:649/5514), multi cylinder, dynamically balanced flywheel, electric start of suitable BHP at 1500 rpm capable of taking 10% over loading for one hour after 12 hours of continuous operation., Dry exhaust mainfold with silencer and Diesel oxidation catalyst & selective catalyst reduction system (isolated from main DG chamber), up to 1.50 M exhaust piping (with LRB insulation & Alum. cladding ) as required .Diesel engine should have Precise emission control by treatment with Diesel exhaust fluid (DEF)/Aqueous urea tank (above 82.5 KVA) as per CPCB 4+ norms
305B) Alternator : AC Brush less SPDP Synchronous alternator rated of appropriate KVA, 415 volts at 1500 rpm, 3 phase, 50 Hz, ac supply with 0.8 lagging power factor. Alternator conforming to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).
306C) Canopy : CPCB / ARAI approved Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from CRCA sheet steel (structure) including sidewals & filled with glasswool (96Kg/m3) /PU Foam. as per IS8183 and the thickness of the doors should be 28/40/50/85 mm as per rating . All doors/opening are sealed with neoprene /EPDN gaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs along with DEF tank (as per OEM standards). There should be provision of protection and tripping of DG set for temperature greater than 50 degree centigrade. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. in open free field environment as per ISO 8528 part 10 duly certified by authorised agency etc.
307D) Instruments : Electronic / Mechanical governor, Manual & electric Start ,Batteries with battery charger, Electronic fuel system, advanced after treatment system (ATS), Exhaust gas recirculation(EGR) System along with Diesel oxidation catalyst(DOC) and Selective catalytic reduction (SCR) , supply module and DCU to control and monitor DEF. Engine instruments panel should have microprocessor based Genset monitoring system capable of displaying Running Hour, RPM, lubbrication oil pressure indication, lubrication oil temperature, battery charging indication, overspeed indication, fuel level etc. The control Panel should equipped with MCCB/ACB of suitable rating.
308E) Base frame and foundation : Both the engine and alternator shall be mounted on suitable base frame made of MS channel & coupled through a flexible coupling or close coupled which shall be installed on existing cement concrete foundation and vibration isolation arrangements as per recommendation of manufacturer.
309F) First filling of the FUEL Tank and DEF tank shall be done by contractor.
310G) DG set will be offered for Inspection and Testing at OEM's Works ( as per approved QAP ) in presence of Departmental Engineers .In case of 13 hour running testing at OEM's works, cost of actual consumables will be reimbursed.
311Note: 1. During the DLP, the contractor shall arrange for servicing of the DG set through authorized dealer of OEM, as per the manufacturers guidelines. The actual cost of consumables used during servicing will be reimbursed to the contractor by the end user department.2. Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration.
312125 KVA at 0.8 pf 415V 50Hz 3-ǿ with 4 Cylinder Engine
313Providing, Fixing, Jointing, Testing & Commissioning of Medium duty MS B class pipes conforming to IS 3589 / 1239 part-I for DG Exhaust applications (beyond 1.5 Mtr. length) including cutting, welding etc & fittings like elbows,flanges, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts . including the cost of thermal insulation with 50 mm thick layers of LRB rock wool as per IS : 8183-1993 (64 kg/m3 density) & 26 SWG aluminium sheet claddings etc complete as required complete in all respect. (Cost of Steel Structure for Exhaust pipe will be paid Extra). .
31480 mm dia
315SITC of Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos of required size 4 pole AC1 duty Power Contactors with 2 no. of required size 4 pole MCCB with Icu=100% Ics 25KA breaking capacity upto 200KVA & 50 KA above 200 KVA rating with adjustable O/L & fixed Short circuit, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: ( M S / RCC structure required for AMF panel will be paid extra )
316100 to 140 KVA
317Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more required complete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of size complete in all respect. .
318Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.
319up to 6 KVAR
32010 KVAR
32120.0 KVAR
32225.0 KVAR
323Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, life expectancy greater than 100000hrs (temp class - 25 D) in 440 V including making connections, testing etc. as required.
324Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank)
325Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 27 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required.
326Red/yellow/Green colour
327Providing & Fixing of CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc. as required .
328Providing & Fixing of Current Transformer confirming IS 2705-I (1992) with secondary terminal and shorting Block , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required .
329Ring type tape wound CT
330C T Class 1, Ratio 200/5 to 600/5, Burden 10 VA
331All in All maintence of the items including UPS system, VRV Air conditioning system , DG Set,RO and Water cooler, Electrical Panels, DB , DB accessories, Earthing system , active and passive networking items and CCTV system, fire detection etc. as per the manufacturer guidelines and as installed at site including consumables and spare parts.
3321st Year after completion of 1 year Warranty period from date of completion of project
3332nd Year after completion of 1 year Warranty period from date of completion of project
3343rd Year after completion of 1 year Warranty period from date of completion of project
3354th Year after completion of 1 year Warranty period from date of completion of project Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57684305
AUTHORITY Government Departments
TENDER VALUE 4.39 Crore
LAST DATE 14-10-2026
Authority
Authority Name Rajcomp Info Services Limited
Work Description Tender for Construction Of Civil, Interior Works & Mep Works Of Makeshift Atal Innovation Studio & Accelerator At Bharatpur
Basic Detail
Tender No F3.3(583)/RISL/PUR/2026/412
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 24 Sep 2026
Submission Date 14 Oct 2026
Open Date 15 Oct 2026
Finance
Tender Value 4.39 Crore
Tender Fee 5000
EMD 8.80 Lakhs
Exemption Available
Document List
BOQ_1061765.xls
d697e3d5-6e9d-44f5-ba26-e0959e7f3be4.html
RFP.pdf
Tendernotice_1 (76).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Oct 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1061765.xls

html

d697e3d5-6e9d-44f5-ba26-e0959e7f3be4.html

pdf

RFP.pdf

pdf

Tendernotice_1 (76).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders