Tender For Special Repair/Renovation Of Circuit House In District Gurdaspur (Punjab)
Tender Value
4.90 Crore
Estimated cost
Bid Submission
08 Oct 2026
5 days left
EMD
9.80 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gurdaspur → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair/Renovation Of Circuit House In District Gurdaspur (Punjab)
BOQ
| Sl. No. | Item Description |
| 1 | Special Repair/Renovation of Circuit House |
| 2 | Removing of Doors from Walls |
| 3 | Dismentaling of Cup Boards |
| 4 | Dismentaling of glazed tiles to be carefully removed |
| 5 | Dismantling cement conglomerate floors 25mm to 50mm thick including concrete base |
| 6 | Dismantling Brick work tikle, masonary or tile lining |
| 7 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth |
| 8 | Providing and applying Anti Termite Treatment using post constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 3 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications by drilling holes in the floor slab & along skirting 300 mm apart & 12 mm dia, drilling holes along all possible entry points such as junctions of floor and walls, door frames, sewage lines, entry points , etc. & injecting them with the chemical solution.. |
| 9 | Screed 40mm thick cement concrete 1:8:16 to be laid below the topping. |
| 10 | Providing and laying Laminate wooden flooring (Grade AC3 or AC3+ laminates) 6 mm to 12 mm thick, having core made up of medium-density fiberboard (MDF),which is less resistant to impact damage and less resistant to being dented by heavy furniture, having a décor layer to give each floor its appearance and consisting of one or more sheets of paper impregnated with melamine resin and top ear layer having clear aluminum oxide finish hat protects the decorative layer & imparts the desired level of sheen, from full gloss to low gloss, duly fixed to the base floor using adhesive as approved by the manufacturer. |
| 11 | Providing and laying vitrified floor tiles of size 813 mm x 1626 mm in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) (M.R.) |
| 12 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 13 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge |
| 14 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ). Size 600x600 mm |
| 15 | Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge: Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 16 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete |
| 17 | 20mm thick cement plaster 1:4 in two coat work. |
| 18 | Scraping |
| 19 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 20 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 21 | Wall painting with plastic emulsion paint ofapproved brand and manufacturer to give aneven shade (two or more coats) |
| 22 | Providing & applying granual/silicaduke homogeneous wall finishing system Consisting of two component system of dry Granual (25 kg/pack) made of 92% silice particle, coated with fade resistant pigmants and 100% acrylic co-polymers bonding agent (5 ltr pack) with the applied thickness of coating being between 0.8 to 1.2mm to be applied in single coat on a cured level smooth plastered, as per the shade combination approved and as per manufacturer specification, all complete inclusive of primer on the base |
| 23 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-35 mm thick |
| 24 | Cost of aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fitting. For shutter area upto 0.50 sqm |
| 25 | Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : (CSR 17.49) 300mm x 16mm |
| 26 | Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-incharge (C.S.R 17.64) |
| 27 | Providing & fixing 30mm thick factory made Hollow PVC Profile PVC Flush door shutter consisting of panel of of 20mm thickness,frame made out of M.S. tubes of size of 19mm x19mm x19 guage inserted inside the hollow section of stiles, top and bottom rails and two 19mm x 19mm MS tubes inserted horizontally inside the hollow profile section sing 5mm thick PVC sheet using screws. Hollow PVC profile shall be lipped with 10mm (5mm x 2) thick x 20mm width on stiles and rails using solvent cement. the inner panel shall be laminated with 5mm thick termite proof, water proof and fire retardant Prelam PVC sheet using solvent cement on both the sides of panel etc. complete as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. (CSR 17.65) |
| 28 | Providing and fixing aluminum Wire Mesh including cost of necessary fittings i.e. screws, U Type Beading etc. complete |
| 29 | Renewing glass panes with putty and nails wherever necessary b) Glass panes weighing 10.75 kg/sqm |
| 30 | Providing & fixing1'-6\\" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge |
| 31 | Providing & fixing 12\\" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 32 | Providing and Fixing 9\\" stainless steel handles ISI marked on door & window frames complete in all respect as per directions of Engineer-in-charge |
| 33 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm) |
| 34 | Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality) |
| 35 | Coloured Granite stone tiles 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps |
| 36 | Providing and fixing commercial ply wood 18mm thick |
| 37 | Providing & Fixing decorative high pressure laminated sheet 1mm (2 Star) thick with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046Type S, including cost of adhesive of approved quality |
| 38 | Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge |
| 39 | Spirit polishing two coats including a coat of wood filler on wood work |
| 40 | Providing and fixing facing extruded clay Tile (Glass Reinforced Clay Tiles (GRC)) any size any shade & design on wall with under layer of 12 mm thick cement plaster 1:3 and jointed with neat cement matched with pigment complete as per drawings, specifications and to the entire satisfaction of engineer- in- charge |
| 41 | Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded) |
| 42 | Providing and Fixing ceiling at height upto 4 mtr consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and to the entire satisfaction of engineer-in- charge |
| 43 | Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 44 | Applying bitumen on roof including heating and carrying to roof. |
| 45 | Iron grated doors, including pintle hinges and arrangements |
| 46 | Providing and Fixing Superior Quality Wall paper with 380 GSM Vinyl paper, PLA (Plant Based resin coating wall paper) pasting with CMC Chemical and adhesives complete including sundries as directed and specified complete in all respects |
| 47 | Providing and Fixing Mouldings of Charcol (2400x35x18) mm fixed in frames with silicons and adhesives including sundries as per directed and specified complete in all respects |
| 48 | 2400x35x18mm |
| 49 | 2400x65x18mm |
| 50 | Providing & Fixing decorative laminated sheet 0.72mm thick and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality |
| 51 | Balance work of Construction of 8 Nos. 400 Sft area Quarter in Circuit House |
| 52 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 53 | Cement concrete 1:8:16 with stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 54 | First class burnt brick laid in cement sand mortar 1:5 in foundation and plinth |
| 55 | 40mm thick cement plaster D.P.C. 1:3 with admixture of water proofing compound @ 1kg./ bag of cement. |
| 56 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. |
| 57 | Scraping: Cement plaster/lime plaster |
| 58 | 20mm thick cement plaster 1:5 in two coat work |
| 59 | 20mm thick cement plaster 1:4 in two coat work |
| 60 | 12.5mm thick cement plaster 1:5 in two coat work |
| 61 | Finishing walls with acrylic smooth exterior paint of required shade with two coats applied @ 1.67 litre/10sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm (CSR 16.60) |
| 62 | Cement pointing 1:3 deep variety. |
| 63 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. (CSR 18.4) |
| 64 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers incluidng ramming, watering and consolidated lead upto 1000 metres. (CSR 6.8 c i) |
| 65 | Providing and laying 60 mm thick factory made cement concrete interlocking Paver blocks of M-40 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge. |
| 66 | Screed 50mm thick cement concrete 1:8:16 to be laid below the topping. |
| 67 | Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded). |
| 68 | Khurra on roof as per item No. 13.45 with GI Spouts 100 mm dia fixed in position. |
| 69 | Bottom khurra on ground 1.2 m. x0.6m. consisting of brick on-edge laid ub cement mortar 1:3 over 75 m.m. cement concrete 1:8:16 including 12.5 m.m. thick cement plaster 1:3. |
| 70 | Cement concrete 1:2:4 gola 10cm. x10 cm. quardrant along junction of roof with parapet wall finished smooth, where specially specified. |
| 71 | Dismantling cement conglomerate floors (25mm to 50mm) thick without concrete base.(CSR 8.17) |
| 72 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.). (CSR 14.115a) |
| 73 | Coloured glazed tiles 20cm x 20cm and 5mm thick in skirting and dado on 12mm thick cement plaster 1:3 in base and jointed with white cement slurry in joints including beveled corners. |
| 74 | Black Granite stone tiles 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. (CSR 14.91) |
| 75 | Factory manufactured 35mm thick flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- |
| 76 | Kiln seasoned hollock wood window glazed shutter 35mm thick |
| 77 | Kiln seasoned hollock wood wire guage door & window shutter 35mm thick |
| 78 | Hollock wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them) a) 30mm thick |
| 79 | Supply & Fixing of pressed steel frames (Chowkats) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section(standard design latest) including iron lugs (hold fasts) iron hinges, confirming to P.W.D. specifications including bolts for fixing stops, locknotch provision for receiving tower bolts, Hydraulic spring and finished with one priming coat of approved quality, fixed in position, including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete. (CSR 18.24) |
| 80 | Doors and windows frame of size 118mmx 60mm with 40 mm wide single rebate weighing 3.43 kg per meter. |
| 81 | Doors and windows frame of size 113mmx 60mm with 35 mm wide single rebate weighing 3.38 kg per meter. |
| 82 | Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-incharge (C.S.R 17.64) |
| 83 | Providing & fixing 30mm thick factory made Hollow PVC Profile PVC Flush door shutter consisting of panel of of 20mm thickness,frame made out of M.S. tubes of size of 19mm x19mm x19 guage inserted inside the hollow section of stiles, top and bottom rails and two 19mm x 19mm MS tubes inserted horizontally inside the hollow profile section sing 5mm thick PVC sheet using screws. Hollow PVC profile shall be lipped with 10mm (5mm x 2) thick x 20mm width on stiles and rails using solvent cement. the inner panel shall be laminated with 5mm thick termite proof, water proof and fire retardant Prelam PVC sheet using solvent cement on both the sides of panel etc. complete as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. (CSR 17.65) |
| 84 | Cost of aluminium ftting complete for doors, windows, sush as T-Bolt, handles etc. |
| 85 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 86 | Applying pink primer or aluminium priming coat with ISI marked quality on wood work including preparation of surface knoting and stopping complete as per PWD specification |
| 87 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 88 | Painting two coats including priming coat with symthetic enamel paint in all shades on new wood work metallic or plastered or concrete surface to give an even shade |
| 89 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish |
| 90 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade. |
| 91 | Construction and Renovation 600 sft & 750 Sft quarters in Circuit House at Gurdaspur. |
| 92 | Dismantling cement conglomerate floors 25mm to 50mm thick including concrete base. |
| 93 | Providing and applying Anti Termite Treatment using post constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 3 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications by drilling holes in the floor slab & along skirting 300 mm apart & 12 mm dia, drilling holes along all possible entry points such as junctions of floor and walls, door frames, sewage lines, entry points , etc. & injecting them with the chemical solution. |
| 94 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 95 | Cement concrete 1:8:16 with stone aggregates 20mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 96 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 97 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 98 | Scraping: Cement plaster/lime plaster |
| 99 | 20mm thick cement plaster 1:4 in two coat work |
| 100 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 101 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material |
| 102 | Providingand fixing1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/ Highlighter/ emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottlegreen, black of size 600x300mm as approved by Engineer-in Charge in skirting, risers of steps and dados over 12mm thick bed of cement Mortar 1:4 (1cement: 4 fine sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 103 | Extra labour for projected nosing of stair case ofany shape and design. |
| 104 | Coloured Granite stone tiles 15mm to 20mm thickin skirting, risers of steps, dado walls and pillarslaid in 12.5mm thick cement mortar 1:3 (1cement 3 coarse sand) and jointed with neatcement slurry mixed with pigment to match theshade of stone, including rubbing and polishingincluding labour for fixing dowel pins and cramps. |
| 105 | Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. |
| 106 | Providing & fixing 30mm thick factory made Hollow PVC Profile PVC Flush door shutter consisting of panel of of 20mm thickness,frame made out of M.S. tubes of size of 19mm x 19mm x19 guage inserted inside the hollow section of stiles, top and bottom rails and two 19mm x 19mm MS tubes inserted horizontally inside the hollow profile section using 5mm thick PVC sheet using screws. Hollow PVC profile shall be lipped with 10mm (5mm x 2) thick x 20mm width on stiles and rails using solvent cement. the inner panel shall be laminated with 5mm thick termite proof, water proof and fire retardant Prelam PVC sheet using solvent cement on both the sides of panel etc. complete as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. |
| 107 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. |
| 108 | Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 109 | Wire gauge Hollock wood door shutter without springs housed in chowkhat. |
| 110 | Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. 35mm thick Panelled, glazed or glazed and panelled. |
| 111 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges: 35mm thick |
| 112 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect 5.0mm thick Plate glass (INDIAN) |
| 113 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 114 | Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 115 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm |
| 116 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 117 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 118 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 119 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm) |
| 120 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 121 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 122 | Finishing walls with exterior paint with silicon additives of required shade with two or more coats applied @1.67 litre/ 10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 123 | Wall painting with plastic emulsion paint ofapproved brand and manufacturer to giveaneven shade (two or more coats) |
| 124 | Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded) |
| 125 | Brick tiles |
| 126 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 127 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 128 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 129 | Providing and laying 60 mm thick factory made cement concrete interlocking Paver blocks of M-35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-inCharge |
| 130 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position. |
| 131 | Water proofing of roof terraces, Basements, Retaining Walls, Water tanks etc with Zydex Zycoprime / Elastobar / Equivalent solution so as to form a water-resistant cementitious bonding coat and to form on-site seamless cross-linked elastomeric membrane on the concrete surface to reduce its porosity. Creating a cementitious elastomeric polymeric membrane of Elastobar and Zycoprime/Equivalent after application of Zycosil & Zycoprime Solution in New Construction. Take equal parts of Elastobar and Cement and form a paste. Add little water to the paste to make it brushable. Apply the paste on surface with brush. Leave the surace for drying for at least 4 - 6 hours to get elastomeric membrane. After this application, make one more layer of rough cementatios membrane using mixture of 1 Part of Zycoprime + 1 Part of Cement + 1 Part of fine sand. Apply paste on the surface with a brush to make a rough texture. Now your surface is ready to bond well with tiles/screed. |
| 132 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 133 | Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex completein all respect. |
| 134 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600 x 600 mm |
| 135 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerincharge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 136 | Construction of Dormitory, Electrical Room, Shed & Public Toilet |
| 137 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 138 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 139 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 140 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 141 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 142 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 143 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 144 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 145 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 146 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 147 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 148 | 12.5 mm thick cement plaster 1:4 |
| 149 | 20mm thick cement plaster 1:4 in two coat work |
| 150 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm |
| 151 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material. |
| 152 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. |
| 153 | Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 154 | Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. 35mm thick Panelled, glazed or glazed and panelled. |
| 155 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position Commercial with elm or gurjan facing on both \ Sides with laminated core 35mm thick |
| 156 | Wire Gauge Red meranti wood Normal (15 to 16 kg per cft. Approx.) door shutter without springs housed in chowkats 35 mm thick |
| 157 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect 5.0mm thick Plate glass (INDIAN) |
| 158 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 159 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm |
| 160 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 161 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 162 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 163 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 164 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 165 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @1.43 litre/ 10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 166 | Wall painting with plastic emulsion paint ofapproved brand and manufacturer to giveaneven shade (two or more coats) |
| 167 | Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 168 | Structural steel work in compound girders or Stanchions built up from two or more R.S. joists or channel section or plates & angles etc. including cutting and fixing all lattice bars, stiffeners, gusset plates, bolts, nuts, rivets, welding rod, etc. complete with flange plates, heads, sole plates, angle connections, etc. with hoisting and erecting in position |
| 169 | Applying priming coat with metal primer onnew steel or iron work including preparation ofsurface. |
| 170 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 57 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm (+ 0.05 %) thick |
| 171 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. |
| 172 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 173 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 174 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 175 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position. |
| 176 | Water proofing of roof terraces, Basements, Retaining Walls, Water tanks etc with Zydex Zycoprime / Elastobar / Equivalent solution so as to form a water-resistant cementitious bonding coat and to form on-site seamless cross-linked elastomeric membrane on the concrete surface to reduce its porosity. Creating a cementitious elastomeric polymeric membrane of Elastobar and Zycoprime/Equivalent after application of Zycosil & Zycoprime Solution in New Construction. Take equal parts of Elastobar and Cement and form a paste. Add little water to the paste to make it brushable. Apply the paste on surface with brush. Leave the surace for drying for at least 4 - 6 hours to get elastomeric membrane. After this application, make one more layer of rough cementatios membrane using mixture of 1 Part of Zycoprime + 1 Part of Cement + 1 Part of fine sand. Apply paste on the surface with a brush to make a rough texture. Now your surface is ready to bond well with tiles/screed. |
| 177 | Disposal building rubbish, Earth, malba with a lead of 5 km including loading, unloading etc. complete in all respect. |
| 178 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing |
| 179 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating leadupto 30 metres |
| 180 | 115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure |
| 181 | Providing and laying Mat finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-inCharge : |
| 182 | Outer Improvement |
| 183 | Dismantling of flexible pavements thickness above 50mm by mechanical means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT&H specifications |
| 184 | Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area as per technical clause 201 of MORT&H specifications |
| 185 | Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications |
| 186 | Earth work in excavation in foundations, frenches, etc. in all kinds of soil where pick jumper work lis not involved and not exceeding 2.0 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge |
| 187 | Cement concrete 1:8:16 with 40mm gauge stone aggregate to be used instead of brick ballast. |
| 188 | Precast Cement Concrete Kerb Plain cement concrete M-20 grade precast kerb 250mm high with bottom width 165mm and top width 115mm fixed in position on earth base including carriage to site of work complete as per technical clause 408 of MORT&H specifications |
| 189 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade made by block making machine with strong vibratory compaction and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for Light Traffic Areas such as Pedestrian plazas, shopping complexes, ramps, car parks, office driveways, housing colonies, office complexes, rural roads with low volume traffic, farm houses, beach sites, tourist resorts, local authority footways, residential roads, etc. |
| 190 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. |
| 191 | Public Health |
| 192 | SUB HEAD NO.1, INTERNAL WATER SUPPLY SYSTEM |
| 193 | CONCEALED IN WALL:- P/F Chlorinated Polyvinyl Chloried (CPVC) pipe as per IS 15778 having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 mtr. spacing including jointing of pipe & fittings with one step PVc solvent cement and testing of pipe complete as per direction of Engineer-In-Charge. |
| 194 | SDR 11 CPVC Pipes & Fittings 20mm o/d |
| 195 | SDR 11 CPVC Pipes & Fittings 25mm o/d |
| 196 | EXPOSED ON WALL:- P/F Chlorinated Polyvinyl Chloried (CPVC) pipe as per IS 15778 having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 mtr. spacing including jointing of pipe & fittings with one step PVc solvent cement and testing of pipe complete as per direction of Engineer-In-Charge. |
| 197 | SDR 11 CPVC Pipes & Fittings 32mm o/d |
| 198 | SDR 11 CPVC Pipes & Fittings 40mm o/d |
| 199 | SDR 11 CPVC Pipes & Fittings 50mm o/d |
| 200 | Cutting holes upto 23cm square thorugh B.B. in cement walls or stone masonary wall in cement for pipes, and making good including repointing, replastering and finishing according to existing finish where required. |
| 201 | Through wall 22.86 cm thick |
| 202 | Providing & Fixing in position C.P. Brass flange under various fixtures complete in all respects (as required by the Engineer-in- Charge) |
| 203 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. |
| 204 | C.P. Brass extension piece, 25mm long to 50mm long |
| 205 | Providing & fixing divertors of approval make (to the approval of Engineer-in-charge) for bath & shower system complete in all respects. |
| 206 | Single lever concealed divertor for bath and shower system (highflow) (with body and upper part) |
| 207 | Providing & fixing in position best Indian make PVC flexible tube connection. |
| 208 | PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut |
| 209 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. |
| 210 | Size 75 mm x 75 mm |
| 211 | SUB HEAD NO.2, ESTATE WATER SUPPLY SYSTEM |
| 212 | Providing water connection with grooved coupler and service coupler in Quick coupling pipe line complete in all respect. |
| 213 | In 101.60mm outside diametre pipe line |
| 214 | Providing and fixing in position automatic brass ball cock in tanks. |
| 215 | 32mm i/d Brass ball Cock with rod and plastic ball |
| 216 | Providing & placing in position on terrace at all floor levels HDPE water storage tanks of approved make to the approval of Engineer-in-Charge with cover with suitable locking arrangements and making necessary holes for inlet, outlet & over flow pipes but without fiiting and base support for tanks. |
| 217 | Tanks upto 12x1000 = 12000 ltr. Capacity Triple Layer |
| 218 | Tanks upto 3x 2000 = 6000 ltr. Capacity Triple Layer |
| 219 | Construction of new platforms at terrace including brick work, steel work & concrete work including shuttering material for resting of PVC water storage tanks (as approved by the Engineer-in-charge). |
| 220 | 1000 Ltrs. Capacity tanks. |
| 221 | 2000 Ltrs. Capacity tanks. |
| 222 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-incharge) in PVC Water storage tanks complete in all respect. |
| 223 | G.I. tank nipple 32mm i/d |
| 224 | G.I. tank nipple 40mm i/d |
| 225 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 226 | 25mm i/d Brass Ball valves |
| 227 | 32mm i/d Brass Ball valves |
| 228 | 40mm i/d Brass Ball valves |
| 229 | Repair & White Wash of Existing Pump Chamber including required repair of machinery, electrical panel, plinth protection, door & window as desired by engineer in charge complete in all respects |
| 230 | Disinfection Unit: |
| 231 | Providing Installing testing and commissioning and one no. electronically actuated, diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 leter of bleaching powder solution /sodium hypo solution per hrs under maximum deliver pressure upto 7kg/cm2 and suction left not less than 1.5 meter. ( Milton Roy or Equivalent Make )(as approved by the Engineer-in-charge). |
| 232 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.with Excavation by Manual means |
| 233 | 63mm o/d pipe of 10 Kgf. / sqcm |
| 234 | 90mm o/d pipe of 10 Kgf. / sqcm |
| 235 | 110mm o/d pipe of 10 Kgf. / sqcm |
| 236 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS1410) and Bronze(gunmetal) working parts sluice valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). |
| 237 | 80mm i/d |
| 238 | 100mm i/d |
| 239 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. |
| 240 | Size 0.9 m. x 0.9 m. |
| 241 | Providing and installing in position of domestic water pressure boosting pump of approved make (To the approval of Engineer-in-charge) including all pump accessaries but excluding cost of G.I pipe & specials complete in all respects. |
| 242 | Pressure pump of 1.0 HP with 3300 LPH, 50meter head with C.I pump & 19 litre capacity Tank |
| 243 | SUB HEAD NO.3, INTERNAL SEWERAGE SYSTEM |
| 244 | Providing and fixing in position H.C.I. soil waste vent or antisyphonage pipes to I.S.I. specification of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of lead jointing. |
| 245 | 100mm i/d H.C.I. pipe lines laid complete |
| 246 | 75mm i/d H.C.I. pipe lines laid complete |
| 247 | Providing lead caulked joints to H.C.I. pipes and specials conforming to I.S.I. Specification of E.L.C. manufacture or any other reputed firm including cost of lead yarn, fuel and tools etc. |
| 248 | 100mm i/d (1.36 kg.) |
| 249 | 75mm i/d (1.13 kg.) |
| 250 | Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. |
| 251 | M.S. Holder bats clamps for 100mm i/d H.C.I. pipes |
| 252 | M.S. Holder bats clamps for 75mm i/d H.C.I. pipes |
| 253 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 254 | Single Socket Type B |
| 255 | 110mm o/d single socket SWR UPVC pipe lines laid complete |
| 256 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 257 | For 110mm i/d pipes |
| 258 | Single Tee with Door |
| 259 | Single Tee |
| 260 | Door Elbow 90 degree (all side socket) |
| 261 | Elbow 90 degree (all side socket) |
| 262 | Vent Cowl |
| 263 | Coupler |
| 264 | P Trap/Floor Trap 110mm x 110mm |
| 265 | Single Y-Junction |
| 266 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material. |
| 267 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate to be laid below the topping using mechanical mixer for mixing of material |
| 268 | Cement concrete 1:2:4 |
| 269 | With stone ballast or shingle |
| 270 | mixing by manual means |
| 271 | SUB HEAD NO.4, ESTATE SEWERAGE SYSTEM |
| 272 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. |
| 273 | 160mm o/d pipe |
| 274 | 200mm o/d pipe |
| 275 | 250mm o/d pipe |
| 276 | Excavation manually in trenches with straight or open cutting in built up street/ lane having wall to wall width of street/ lane upto 3.0 metre, for intramural sullage drains, extramural intercepting drains and outfall drains, storm water channels and other work contingent or incident thereto, to full dimensions and depth as shown on the drawings or as shall be required by Engineer in-charge including dressing to correct sections and dimensions according to templates and levels, dewatering of rain water, diversion of traffic. Providing and fixing and maintenance of caution boards, fencing, night signals, for leads upto 15m and for all lifts and subsequent refilling, watering and dressing upto groung level, including removal of surplus spoil from the site upto 15 metre distance complete in all respects. |
| 277 | All classes of soil except rocky |
| 278 | Providing and filling sand grading as per specifications or fine grade around the various sizes of pipes in external work |
| 279 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. with three coats of black bitumastic superior paint of approved manufacture on all C.I. work as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. |
| 280 | 150mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 281 | Construction of brick masonry inspection chambers size as given below upto 0.60 m average depth in 1:5 cement sand mortar, lime concrete with 40 per cent lime mortar 2:3 in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside light duty C.I. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 282 | Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal |
| 283 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 284 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete. |
| 285 | For pipes 100 to 250 mm Diametre |
| 286 | Disilting of manhole including all safety measures, cost of container, T&P and disposal of silt upto 5km complete in all respects. |
| 287 | Depth upto 3 m. |
| 288 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. |
| 289 | Inside size 90x150 cm and 120 cm deep |
| 290 | SUB HEAD NO.5, DISMANTLING |
| 291 | Dismantling Concrete Reinforced cement concrete |
| 292 | 1000 Ltrs. Capacity tanks. = 10x4X1X0.23X1 = 9.20 |
| 293 | 5000 Ltrs. Capacity tanks. = 2x4X1.5X0.23X1.5 = 4.14 |
| 294 | Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 295 | Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 296 | SUB HEAD NO.6, TILES & GRANITE |
| 297 | Providing and fixing 1st quality Vitrified glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 600 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. As per detail attached |
| 298 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. As per detail attached |
| 299 | Size 600x600 mm |
| 300 | Providing and laying Polished Granite stone 18mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 301 | Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 302 | SUB HEAD NO.7, WASHING & SANITARY INSTALLATION |
| 303 | Providing and fixing in position Chinaware Indian Orisa water closet sizes 580mmx440mm (to the approval of the Engineer-in-charge) suite-consisting of 10 ltr. PVC flushing cistern supported on angle iron bracket including cost of long bend 32 mm dia complete in all respect and to the entire satisfaction of engineer in charge. |
| 304 | Providing and fixing in position Chinaware European type water closet P trap or S trap (to the approval of the Engineer-in-charge) suite-consisting of 10 ltr. PVC flushing cistern supported on angle iron bracket, short bend 32 mm dia including cost of solid white cover complete in all respect and to the entire satisfaction of engineer in charge. |
| 305 | Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 306 | Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect. |
| 307 | Providing and fixing jet spray with 2'-6\\" long PVC pipe. |
| 308 | With C.P. Brass nut |
| 309 | Providing and fixing Stainless steel health faucet complete in all respect. |
| 310 | Providing and fixing in position Metropole flush valve push type 32mm size dual flow (Concealed body) with exposed shut off provision and round plate complete in all respect. |
| 311 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. |
| 312 | Providing and fixing in position best Indian make vitreous Chinaware white channel of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete as per required by the Engineer-in-charge. |
| 313 | Providing and fixing partition for different type of urinals. |
| 314 | Chittor Black Slabs 19-20mm thick marble partition size 375mm x 750mm |
| 315 | Providing and fixing in position best Indian make lavatory suites (with full anti-splashrim in vitreous Chinaware consisting of C.P. brass waste 32mm dia, pair of angle iron bracket with one C.P. brass tap complete. |
| 316 | Size 630mm x 450mm x 830mm |
| 317 | Table Top (size 49 x 40 x 15 cm) |
| 318 | Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer-in- charge) complete in all respect. |
| 319 | Providing and fixing vitreous chinaware standard pedestal for wash basin. |
| 320 | Vitreous chinaware standard white pedestal for wash basin. |
| 321 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 322 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. |
| 323 | Providing and fixing in position SS Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed into wall with brass screws complete in all respect. |
| 324 | 35mm dia 600mm (24”) long |
| 325 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick, grade-304 (18/8) with waste coupling complete in all respect. |
| 326 | Rectangular Sink with Deluxe Border Single Bowl Overall Size 700 mm x 555 mm x 230 mm |
| 327 | Double bowl Sink without drain board Overall size 1114 x 490 mm with bowl size 460x385x200mm including waste coupling |
| 328 | Providing and fixing in position C.P. brass overhead shower 1 flow with shower arm with 15mm i/d inlet of approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 329 | Providing and fixing in position paper holders fixed in to wall with C.P brass screws complete in all respects including cutting and making good the walls etc. |
| 330 | Chromium plated brass toilet paper holder |
| 331 | Providing and fixing in position towel rails / ring fixed in with rawl plugs embedded in walls with brass screws, complete in all respects including cutting and making good the walls etc. |
| 332 | C.P. brass towel Rails size 15mm dia 610mm long |
| 333 | C.P brass towel ring |
| 334 | Providing and fixing in position Acrylic shelf with Acrylic guard rails fixed in with rawl plugs with C.P brass screws complete including cutting and making good the walls etc. |
| 335 | CP Acrylic Shelf size 560mmx130mm |
| 336 | C.P. brass Glass Corner with rail 8 mm thickness and height 250 mm |
| 337 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 338 | Providing & Fixing in position best indian make bevelled edge 5mm thick mirror mounted on 4mm thick Cardboard sheet ground fixed in position by means of 4 nos. chromium plated brass screws and washers over rubber washers and rawl plugs embedded in the walls or chromium plated brass clamps with C.P. brass screws (as required by the Engineer-in- Charge) complete including cutting and making good the walls etc. |
| 339 | Size 600mmx450mm |
| 340 | Size 1500mmx600mm or any other size |
| 341 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. |
| 342 | C.P. Brass khunti with 6 pegs |
| 343 | Providing and fixing in position C.P brass Single Lever basin mixer without Popup waste with 450 mm Long Braided Hoses approved make (to the approval of Engineerin- charge) complete in all respect. |
| 344 | Providing & fixing in position 15 mm i/d C.P brass wall mixer of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 345 | C.P brass wall mixer with Telephonic Shower |
| 346 | Providing & fixing in position C.P brass Sink mixer swivel spout (Wall mounted) of approved make (to the approval of Engineerin- charge) complete in all respect. |
| 347 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 348 | C.P. brass Bib cock long nose/ long body foam flow without flange |
| 349 | C.P. brass Bib cock foam flow without flange |
| 350 | Providing & Fixing in postion stop cock / Angle valve (as approved by the Engineer-in-charge). |
| 351 | C.P.brass 15mm angle valve without flange. |
| 352 | C.P.brass 15mm Concealed stop cock with flange. |
| 353 | Providing and fixing in position C.P. brass Tumbler Holder of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 354 | Providing & Fixing in postion liquid soap container of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 355 | C.P. brass liquid soap container |
| 356 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will beallowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 357 | SUB HEAD NO.8, PREMIUM RANGE INSTALLATION |
| 358 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 359 | Note:-To be provided only for VIP Installations and with prior approval of the Engineer-in-charge. |
| 360 | C.P. Brass fittings: |
| 361 | C.P. Brass Pillar Cock foam flow |
| 362 | C.P. brass Bib cock with Wall flange |
| 363 | C.P.brass 15mm Angular stop cock with Wall flange |
| 364 | C.P. brass 15mm Concealed stop cock with adjustable wall flangewith seal. (Outer +Inner Body) |
| 365 | C.P. brass 3-Hole Basin Mixer Without Popup Waste System |
| 366 | C.P. Brass Wall mixer with Non telephonic shower arrangement. |
| 367 | C.P. brass overhead shower Φ180mm round shape single flow with shower arm with 20mm i/d Inlet and 300mm long round shape with 900 bend with flange. |
| 368 | C.P. Brass Accessories: |
| 369 | C.P. brass towel rail 600 mm long |
| 370 | C.P brass towel ring square |
| 371 | C.P. brass soap dish holder with glass dish |
| 372 | C.P. brass toilet roll holder with flap |
| 373 | C.P. Glass Shelf 600mm long |
| 374 | C.P. brass towel rack 600mm long with lower hangers |
| 375 | SUB HEAD NO. 9, AIR CONDITIONERS, WATER COOLER , R.O. & GEYSER |
| 376 | AIR CONDITIONERProviding and Installing of Split Type wall mounted Air Conditioning Unit with latest inverter Technology of 2.00 tonne Capacity, 5 star Rating with 230 Volts single phase supply with nature friendly refrigerant R32 gas including 3mtr copper insulation pipe, which is capable of performing the following functions:- (i) cooling capacity of 20813 to 24,000 British Thermal Units (BTUs) per hour(ii) Dehumidifying mode(iii) Air Circulation (iv) Filtering including installation charges. (v) ISEER of 5.05(vi) Airflow and temperature Proper airflow can help eliminate hot and cold spots in your home, making all the rooms closer to your desired temperatureAs desired by the Engineer-in-charges Complete in all Respect. As per Analysis Attached |
| 377 | AIR CONDITIONERProviding and Installing of Split Type wall mounted Air Conditioning Unit with latest inverter Technology of 1.50 tonne Capacity, 5 star Rating with 230 Volts single phase supply with nature friendly refrigerant R32 gas including 3mtr copper insulation pipe, which is capable of performing the following functions:- (i) cooling capacity of 17813 to 18,000 British Thermal Units (BTUs) per hour(ii) Dehumidifying mode(iii) Air Circulation (iv) Filtering including installation charges. (v) ISEER of 4.93(vi) Airflow and temperature Proper airflow can help eliminate hot and cold spots in your home, making all the rooms closer to your desired temperatureAs desired by the Engineer-in-charges Complete in all Respect. As per Analysis Attached |
| 378 | OUTDOOR UNIT STANDProviding and Fixing Heavy Duty Mild Steel Outdoor unit stand for Air Conditioning Outdoor unit. (Powder Coated) complete in all respect as desired by the Engineer-in-charge:- |
| 379 | COPPER PIPESupplying & Installation of heavy duty hard soft copper refrigrant piping from indoor to outdoor unit including all required fitting, as desired by the Engineer-in-charges Complete in all Respect. As per Analysis Attached |
| 380 | AUTOMATIC VOLTAGE STABLIZERSupply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- as desired by the Engineer-in-charges Complete in all Respect. |
| 381 | Automatic Voltage Stablizer 5 KVA for 2.0 TR Capacity Air Conditioners |
| 382 | Automatic Voltage Stablizer 4 KVA for 1.5 TR Capacity Air Conditioners |
| 383 | MCB ARRANGEMENTSSupply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- as desired by the Engineer-in-charges Complete in all Respect. |
| 384 | MCB Double Pole 6-32amp. (10kA, Curve- C) |
| 385 | PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE: |
| 386 | Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 387 | Overall size 4.0sq.mm (84/0.3mm), 3Core |
| 388 | CASING & CAPPINGSupply & erection of Best Quailty HD PVC Casing 'n' Capping (Double Lock) Batten type ISI marked for covering the copper pipe, drain pipe & wiring arrangements including cost of bends (L), (U), (T) & inspection boxes etc., where necessary including other petty material complete in all respects, as desired by the Engineer-in-charge:- |
| 389 | PVC Casing 'n' Capping Size 50mm x 16mm |
| 390 | CUTTING HOLES IN WALLCutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required complete in all respects, as desired by the Engineer-in-charge:- |
| 391 | Through wall 22.86 cm thick |
| 392 | UPVC PIPELINEProviding and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. |
| 393 | uPVC Pipe 10 Kgf/cm2 |
| 394 | 25mm i/d Vertical Drain pipe |
| 395 | uPVC Pipe 6 Kgf/cm2 |
| 396 | 40mm i/d Horizontal Drain pipe |
| 397 | Providing and fixing in position storage type automatic electric water heater pressure/ non pressure type thermostatically controlled single phase, vertical wall mounted of approved make (to the approval of engineer in-charge) with thermostats, inner container of stainless steel complete with 1 mtr three core flexible cord with plug, non plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. |
| 398 | 25 Litre capacity water heater |
| 399 | WATER COOLERProviding & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. |
| 400 | Water Cooler Full Steel Body 60/80 ltr Capacity without Stablizer |
| 401 | AUTOMATIC VOLTAGE STABLIZERSupply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- as desired by the Engineer-in-charges Complete in all Respect. |
| 402 | Automatic Voltage Stablizer 5 KVA for Water Coolers |
| 403 | UV FILTERProviding & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) includingcarriage and fixing in position complete in all respect. |
| 404 | SUB HEAD NO.11, FIRE FIGHTING |
| 405 | Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect.6kg Capacity |
| 406 | RECESSED AIR CONDITION SUPPLY TERMINAL POINTS: |
| 407 | Wiring air condition supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases:- |
| 408 | Wiring AC supply terminal points having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 409 | Wiring Computer terminal points having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16/20Amp. universal Socket (shuttered), 2Nos. 16/20Amp. switch with indiicator and 2No. blanking plate (Modular accessories). |
| 410 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: |
| 411 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:- |
| 412 | Wiring fan point (Without fan box) |
| 413 | Wiring fan point (With fan box) |
| 414 | Wiring light point |
| 415 | Wiring call-bell point |
| 416 | Wiring 6Amp. wall socket point |
| 417 | Wiring 6Amp. Plug control comprising wall socket point |
| 418 | Wiring 16/20Amp. power plug control point |
| 419 | Wiring light point with double control switches. |
| 420 | REPLACEMENT OF WIRES, COVER FRAMES, MODULAR SWITCHES, CONCEALED METAL BOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPE ACCESSORIES) Derived from 34.01: |
| 421 | Replacement of PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (Derived From CSR 34.01). |
| 422 | Wiring fan point (Without fan box) |
| 423 | Wiring light point |
| 424 | Wiring 6Amp. Plug control comprising wall socket point |
| 425 | Wiring 16/20Amp. power plug control point |
| 426 | PVC INSULATED FR COPPER CONDUCTOR CABLES: |
| 427 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 428 | Overall size 1.5sq.mm (Un-sheathed) |
| 429 | Overall size 2.5sq.mm (Un-sheathed) |
| 430 | Overall size 4sq.mm (Un-sheathed) |
| 431 | Overall size 6sq.mm (Un-sheathed) |
| 432 | Overall size 10sq.mm (Un-sheathed) |
| 433 | Overall size 16sq.mm (Un-sheathed)( For Sub Main )(Ground floor,First floor & Solar Main) |
| 434 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE): |
| 435 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part- 1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 436 | Overall size 185sq.mm (3½ Core) Un-armoured (Loose) |
| 437 | Overall size 70sq.mm (3½ Core) Un-armoured (Loose)(for VTP&N light) |
| 438 | Overall size 120sq.mm (3½ Core) Un-armoured (Loose)(for VTP&N Power) |
| 439 | Overall size 16sq.mm (4Core) Un-armoured (Loose)(for dormetary) |
| 440 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: |
| 441 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, MS saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 442 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 443 | Heavy Gauge PVC Conduit Pipe 32mm dia. (Flushed) ( for Sub Main & approach to First floor )& Solar |
| 444 | G.I. EARTHING: |
| 445 | Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 446 | Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length)( for dormetry TPN 4 way box) |
| 447 | G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH): |
| 448 | Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (On Surface) with sockets, elbows and MS saddle clamps including painting etc. |
| 449 | Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface) |
| 450 | COPPER EARTHING: |
| 451 | 8 SWG COPPER EARTHING : |
| 452 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 453 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long (for 2 no. VTP&N 8 way power+light) |
| 454 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- |
| 455 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface) |
| 456 | COPPER EARTHING (Upto 8 metre in Length): |
| 457 | Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation:- |
| 458 | Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length)(for main cubical panel) |
| 459 | COPPER EARTHING STRIP (As Additional Length): |
| 460 | Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc:- |
| 461 | Additional Length 20mm x 3mm thick Copper Tape |
| 462 | SUPPLY AND ERECTION OF WIRING ACCESSORIES: |
| 463 | Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc:- |
| 464 | Bakelite Batten Holder (Large size) |
| 465 | Call Bell 220/230 volts AC Ding Dong |
| 466 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: |
| 467 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 468 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 469 | MCB Double Pole 50, 63amp. (10kA, Curve-C) |
| 470 | MCB Triple Pole 50, 63amp. (10kA, Curve-C) (for VT&N 8 way light & power) |
| 471 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 472 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: |
| 473 | Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 474 | SP&N Double Door Distribution Board 8 way each(for security check post) |
| 475 | SP&N Double Door Distribution Board 12 way each(for quartrer) |
| 476 | TP&N Horizontal Double Door Distribution Board 4 way each( for 1 no dormetary & 16 no. main building) |
| 477 | Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- |
| 478 | TP&N Double Door Vertical DB's 8 way each (With provision of FP MCCB 160amp.)(for light) |
| 479 | TP&N Double Door Vertical DB's 8 way each (With provision of FP MCCB 200-250amp.)(for power) |
| 480 | ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure): |
| 481 | Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connection on both sides of switch with sutiable size of thimbles as per PWD General Specifications:- |
| 482 | On Load Change Over Switch Four Pole 200amp., 415volts (With Sheet Enclosure) |
| 483 | SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS): |
| 484 | Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus-bar strips of suitable length and cross-sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site:- |
| 485 | Bus Bar Chamber 200amp., 415volts Overall Dimensions (780mm x 510mm x 215mm) nominal |
| 486 | MCCB's (MOULDED CASE CIRCUIT BREAKER): |
| 487 | Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 488 | MCCB Four Pole 160amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting (for light) |
| 489 | MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting.(for power) |
| 490 | MCCB Four Pole 400amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting(for main) |
| 491 | MS SHEET ENCLOSURE FOR MCCB's: |
| 492 | Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 493 | MS Sheet Enclosure having provision for MCCB 200-630Amp.with extended rotary handle (Approx. Size 750mm x 300mm x 250mm) |
| 494 | OVER HEAD DISTRIBUTION ALUMINIUM CABLES, ACSR CONDUCTORS, CLAMPS, JUMPERS & JOINT KITS: |
| 495 | Wiring over-head line in PVC insulated & PVC sheathed two single core aluminium conductor cable overall 1100 volts grade binding with G.I. wire 2mm dia. (14 SWG) with brass/ aluminium link clips complete in all respect as approved and desired by the Engineer In-Charge at site. |
| 496 | PVC insulated & PVC sheathed aluminium conductor cable Overall Size 16mm² (1/1.40mm) Twin Core(for 13 no quarter) |
| 497 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: |
| 498 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 499 | Double Walled Corrugated HDPE Pipe 63/ 51mm (Outer/ Inner dia.)(for dormetary) |
| 500 | Double Walled Corrugated HDPE Pipe 120/ 103.5mm (Outer/ Inner dia.)(for pspcl to cubical panel) |
| 501 | CUBICAL PEDESTAL: |
| 502 | Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- |
| 503 | Cubical Size 1400mm high, 1200mm wide and 500mm deep with platform dimensions 1300mm x 600mm x 450mm |
| 504 | Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. besides the lighting fixture manufacturer should have inhouse NABL accredited lab. |
| 505 | Supply and erection of BEE 3 star rating AC Ceiling Fan 1200mm (48\\") Suitable for 230 V single phase with double ball bearing copper wound full aluminium body ,3 no.s blades white in colour .The mounting type is down rod mount .The product should possess a minimum air deleveryof 210 CMM .The rated speed of the product must be minimum of 300 revolution per minute and 5 no.s of speeds .the approximate weight of the product should be 4kg and 189gms without packing or higher .the product should have a manufacturer`s guarantee / warranty of minimum 2 years .the product should be complete in all respects with fan motor blade set doen rod canopy set. shackle kit .twisted wire etc. incluyding erecection & testing of ceiling fans having connection With PVC insulated PVC sheathed two single core copper conductor ( FR ) cable 0.75 sqmm. complete in all respects and desired by the engineer-in charge at site |
| 506 | Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 507 | Supply and erection of recessed mounted 36 WATT LED panel 2x2 (including constant LED driver) with CRACA sheet having efficency of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3% with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory |
| 508 | Supply and erection of slim Recessed mounted, Round downlighter 18 watt with pressure die cast or extruded aluminium housing& Polycarbonate diffuser with surge protection 10 KV and efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3% housing & driver shall be of same brand, ,supported with LM 79 repports not more than 2 years old from NABL/UL accredited Labortory complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 509 | Supply and erection of Wall Fan Plastic Body 400MM, 16\\" Including flexible wire & petty material etc. for connections and test complete in all respect as approved and desired by the Engineer in-charges at site. |
| 510 | Campus Lighting & Security Lighting |
| 511 | Supply and erection of PVC insulated PVC sheathed 3 core round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 512 | Overall size 1.5sq.mm (48/0.20mm), 3Core |
| 513 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE): |
| 514 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part- 1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 515 | Overall size 10sq.mm (4Core) Un-armoured (Loose) |
| 516 | XLPE INSULATED ARMOURED CABLES (ON SURFACE): |
| 517 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 518 | Overall size 10sq.mm (2Core) Armoured (On-Surface) |
| 519 | G.I. EARTHING: |
| 520 | Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 521 | Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) |
| 522 | Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be grouted upto complete length vertically:- |
| 523 | GI Earth rod 20 mm dia., 3 mtr. Long |
| 524 | SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS): |
| 525 | Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus-bar strips of suitable length and cross- sectional area mounted on DMC/ SMC moulds at sufficient distance enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site:- |
| 526 | Bus Bar Chamber 63amp., 415volts Overall Dimensions (300mm x 345mm x 120mm) nominal |
| 527 | MCCB'S (MOULDED CASE CIRCUIT BREAKER): |
| 528 | Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (Conforms to IEC:60947-2) having Ics=100%, Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of thimbles etc:- |
| 529 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 530 | MS SHEET ENCLOSURE FOR MCCB'S: |
| 531 | Supply & Erection of indoor type MCCB enclosure of suitble size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 532 | MS Sheet Enclosure having provision for MCCB 40- 160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 533 | TIMER: |
| 534 | S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre- fixed timings complete in all respect as per satisfaction of Engineer-in-charge:- |
| 535 | Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C- Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) |
| 536 | PAINTING INCLUDING LABOUR AND MATERIAL: |
| 537 | Painting of Galvanized iron pipe pole including bracket with two coats of aluminium paint (With brush):- |
| 538 | Overall Length 6.1 Metre |
| 539 | Painting of G.I./ Conduit pipes with two coats of approved paint (With brush) including cleaning the surface etc:- |
| 540 | Painting of G.I. Pipe 15mm and Conduit Pipe 20mm dia. |
| 541 | GI PIPE POLES & BRACKETS: |
| 542 | GI PIPE POLES: |
| 543 | Supply and erection of G.I. pipe ‘A’ quality of suitable length and dia. conforming to IS:1239 (Part I) 1979, including fixing up to a given depth below G/L, the hole of excavation about 30cm dia. and given depth to be filled in up to 15cm below G/L with 1:2:4 cement concrete including painting of pole with two coats of approved aluminium paint as required:- |
| 544 | GI Pipe Pole 6.1 metre Long, Dia. 80mm, Planting Depth 120cm with Pit Depth 135cm. |
| 545 | SINGLE ARM BRACKETS FOR GI PIPE POLE: |
| 546 | Supply and erection of G.I. Pipe (A-Class) Single arm bracket of suitable length to give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the existing surface/ wall with 2nos. MS flat clamp 25mm x 5mm, 30cm long and 4nos. fastner 10mm x 75mm long with two coats of an approved aluminium paint complete in all respect as approved by the Engineer-in-charge at site:- |
| 547 | Single Arm Bracket 1 metre Long GI Pipe 40mm Dia. |
| 548 | CEMENT CONCRETE MUFFS: |
| 549 | Making of Cement Concrete muff of suitable size and length with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole sufficient to completely flush a SMC FRP (Glass Fibre reinforced polyester sheet moulding compound confirming to IS:13410) Junction Box conform to IS:14772, inner dimensions 250mm x 200mm x 100mm (Outer dimensions 295mm x 255mm x 120mm) with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's). The FRP Box is to be fixed with the pole by a MS flat clamp of size 20mm x 2mm thick. PVC pipe 40mm dia. (2No.x0.60m) should be provided for incoming and outgoing cables. The outer surface of the muff shall be finished with pure cement & two coats of white snowcem complete in all respect as approved and desired by the Engineer In-Charge at site:- |
| 550 | Cement Concrete Muff of Overall Size 450mm dia., 80cm Long |
| 551 | Supply and erection of SMC FRP (Glass Fibre reinforced polyester sheet moulding compound conforming to IS:13410) Junction Box (Recessed/ On surface) conform to IS:14772, robust constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site. |
| 552 | SMC FRP (Glass Fibre reinforced polyester sheet moulding compound confirming to IS:13410) Junction Box conform to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement |
| 553 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: |
| 554 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 555 | Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) |
| 556 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES: |
| 557 | CUBICAL PEDESTAL: |
| 558 | Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable with 4no. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth to be erected in the 1:2:4 cement concrete mixture, the platform of 150mm high from ground level & 450mm thick & 150mm from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- |
| 559 | Cubical Size 1200mm high, 900mm wide and 350mm deep with Platform Dimention 1000mmx450mmx450mm |
| 560 | Supply & Erection of LED Post Top 40/45 Watt with IP 65 Protection (including LED Driver) having efficacy of LED fixture more than 100 lumens per watt and operating voltage between 240 to 270 volt, Input AC Frequency 50 Hz +- 3% complete along with erection of the same with, testing, complete in all respect as per approved /desired by the engineer in charge of work at site The Certification and Specification of The Led fitting should be as approved by of O/o Advisior( Technical) Govt. of Punjab Letter No: AT/2021/GL/1410-1422 Dated 06-05-2021 Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 561 | Supply and erection of LED Flood Light 120 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single driver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection). THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab |
| 562 | Supply & Erection of 45 Watt Street Light New generation energy saving and Enviornment friendly long life LED Street light made up pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection and impact resistance of IK07. Input AC Frequency Hz +- 3% complete along with erection of the same with, testing, in all Respect and efficacy of LED Fixture minimum 120 limens per watt complete in all respect as per approved /desired by the engineer in charge of work at site The Certification and Specification of The Led fitting should be as approved by of O/o Advisior( Technical) Govt. of Punjab Letter No: AT/2021/GL/1410-1422 Dated 16-05-2021 Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 563 | EPABX |
| 564 | Supply, installation, testing & commissioning of Hybrid IP PBX System having following features: hybrid communication system supporting integration of Analog, SIP, PRI and GSM connectivity with capability up to 64 IP extensions and cabinet supporting up to 64 TDM ports; equipped with 1 GHz processor and Linux-based operating system; supporting multi-level 8 port auto attendant with features including auto call-back (busy and no reply), basic call handling, broker’s call, call forward (external), call hold, call park, call pickup (selective/group) and call split; supporting call transfer, call waiting/call camp on, CLI-based routing, 3-party conferencing, distinctive ring (SLT), executive ring, abbreviated dialing and extended abbreviated dialing, hunt group, last number redial, least cost routing, MSN-based routing, smart callback and support for third-party SIP phones; supporting meet-me conferencing and ad-hoc conferencing with concurrent TDM-IP calls up to 20 channels (maximum); supporting GUI-based system configuration and management with remote programming through PC connectivity and web interface for live status; supporting advanced features including multi-level auto attendant, multiparty conferencing, VMS/remote VMS access, internal voice prompts and system log for maintenance; system features including call billing, class of service, date and time setting, day/night mode (manual/auto), flexible numbering, jun landing with time zone and voice guidance with time zone; supporting 8 SIP-PRI accounts with simultaneous 2 service providers and 4 channel voice mail with 4-hour storage and remote mailbox access; operating voltage 210–240V AC at 50 Hz with power backup provision 24V with 7Ah × 2 batteries; connectivity through RS232 PC port and Ethernet interface; operating temperature up to 50°C; compact cabinet design with dimensions approximately 360 mm × 160 mm × 464 mm (W × H × D) and weight approx. 6 kg (without cards); complete in all respects including supply, installation, testing and commissioning as approved and directed by the Engineer-in-Charge at site. |
| 565 | Supply, installation, testing & commissioning of 50 Pair MDF Box with Krone Modules having following features: MDF designed to terminate 50 telephone pairs and comprising five (5) numbers of 10-pair Krone modules (disconnect type preferred); MDF enclosure of outdoor type fabricated from powder-coated CRCA (Cold Rolled Close Annealed) steel with minimum IP55 protection as per IEC 60529 against dust and low-pressure water jets; provided with hinged door and locking arrangement such as cam lock with key or quarter-turn lock for protection against unauthorized access; equipped with cable entry and exit points with suitable grommets or glands to maintain IP rating and protect cables; provision for earthing/grounding terminal; adequate internal space for proper cable management, bending radius and dressing; Krone modules of LSA-PLUS or equivalent IDC type suitable for termination of solid copper conductors ranging from 0.4 mm to 0.8 mm diameter (26 AWG to 20 AWG) with minimum insertion life of 200 insertions without degradation of connection quality; modules mounted using snap-in or screw-in arrangement on standard back-mount frame inside MDF box; all components shall be new, unused, of highest quality and fully compatible with standard telecommunication infrastructure; suitable for continuous operation in climatic conditions including high temperature, humidity and dust; complete in all respects including supply, installation, testing and commissioning as approved and directed by the Engineer-in-Charge at site. |
| 566 | Supply, installation, testing & commissioning of Analogue Telephone Instrument having following features: single line analog telephone compatible with standard PSTN and PBX systems operating on loop start signaling; supporting DTMF dialing with keypad having minimum 12 numeric keys and additional function keys; equipped with adjustable ringer volume control (high/low/off) and selectable tone/pulse dialing mode; supporting features including last number redial, flash (hook switch) for call transfer, pause function and mute function; provision for wall mounting and desktop use; equipped with electronic ringer with clear audible indication; handset with ergonomic design and durable cord; telephone body made of high-quality ABS plastic material; line interface through RJ11 port with standard 2-wire connectivity; low power consumption powered directly from telephone line (no external power required); compatible with PBX systems, MDF termination and telecom infrastructure; suitable for continuous operation in indoor conditions; complete in all respects including supply, installation, testing and commissioning as approved and directed by the Engineer-in-Charge at site. |
| 567 | Supply, installation, testing & commissioning of IP Telephone Instrument having following features: support for minimum 4 SIP lines with SIP hotspot capability and support for up to 6-way local conferencing; equipped with 2.4-inch color LCD display with resolution 320 × 240 pixels; supporting HD voice on handset and speakerphone with wideband and narrowband codecs including G.711a/u, G.723.1, G.726, G.729A/B, iLBC, G.722 and Opus; full duplex acoustic echo cancellation with noise reduction features including VAD, CNG, BNE, AGC and PLC; supporting DTMF in-band, RFC2833 and SIP INFO; supporting features including call hold, resume, call waiting, intercom, caller ID display, speed dial, anonymous call, call forward (always/busy/no answer), call transfer (attended/unattended), call parking and pickup (server dependent), redial, do-not-disturb, auto answering, voice message (server dependent), hot line and hot desking; local phonebook capacity minimum 1000 entries, remote phonebook (XML/LDAP) 1000 entries and call logs (incoming/outgoing/missed) up to 600 entries; equipped with programmable DSS/soft keys, blocked/allowed list and voice message waiting indication (VMWI); supporting dual 10/100 Mbps Ethernet ports with bridged PC port and integrated PoE with optional external power supply; supporting IPv4/IPv6, DHCP, PPPoE, VLAN, LLDP, QoS, 802.1X authentication, VPN (L2TP/OpenVPN) and network time synchronization; supported protocols including SIP 2.0 over UDP/TCP/TLS, RTP/RTCP/SRTP, STUN, DHCP, SNTP, FTP/TFTP, HTTP/HTTPS, TR-069 and AES128/AES256 encryption; deployment and management through auto provisioning (FTP/TFTP/HTTP/HTTPS/DHCP Option 66/SIP PNP/TR-069), web management portal, configuration import/export and firmware upgrade; equipped with keypad of 36 keys including 4 soft keys, 9 function keys, 3 line keys with LED indicators, navigation keys, numeric keypad and volume control keys; interfaces including RJ9 ports for handset and headset, dual RJ45 ports (network and PC), DC input (5V/0.6A) and security slot; power consumption approximately 0.84–1.43W (adapter) and 1.32–2.09W (PoE); operating temperature 0°C to 45°C and humidity 10% to 95%; installation options desktop stand (adjustable angles) and wall mounting; device dimensions approximately 169 × 203.6 × 172.7 mm (45° stand) and 169 × 194 × 181 mm (50° stand); complete in all respects including supply, installation, testing and commissioning as approved and directed by the Engineer-in-Charge at site. |
| 568 | RECESSED MODULAR TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS: |
| 569 | Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases:- Accessories |
| 570 | Wiring Telephone socket point RJ11 (one module) |
| 571 | Supply and erection of telephone cable with solid bare copper conductor, special grade PE insulation, paired, polyster taped, nylon rip cord, FR PVC sheathed, conforming to TEC Specification No. G/WIR-06/03 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 572 | Telephone Cable 0.5 Sq.mm, 2 Pair |
| 573 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: |
| 574 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, MS saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 575 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 576 | Solar Power Generation System: (6 KW.) |
| 577 | Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimumcapacity including required quantities of SPV modules (High power density Monocrytalline based single module of capacity +500 watt) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter with 2Nos. GI Chemical earthing with suitable size GI strip upto string inverter and AC & DC distribution panel), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Provision of Lightening Arrestor & 2 Nos. GI chemical earthing with suitable size GI strip upto Lightning arrestor, Hot dip galvanized MS Mounting Structures (1No. GI Chemical earthing with suitable size GI strip upto mounting structure) should be designed to withstand the speed for the wind Zone of the location (150 Km/hr-170 Km/hr) Complete in all respect with transportaion, fabrication, labour & Civil Work etc Features :-1. Solar PV Module warranty 25 Years & certified under IS/IEC 61730 I & II IS/IEC 61701 & IS/EC 14286 2. Power Conditioning unit (string solar inverter) & certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 60529 3. Structure 25 Years service life with AMC & certified under IS 2062 2011 4. Complete Plant insurance for the period of 5 Years (Excluding Theft of the Material) 5. Annual Maintenance contract for the period of 10 Years. |
| 578 | #The work will got done from approved MNRE (Misitry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) contractor #The capacity of solar power plant my increase or decrese as availability of site it can also be totally removed from executive end The Rate are inclusive of all taxes including GST |
| 579 | DIESEL GENERTAOR SET 125 KVA (SILENT) |
| 580 | Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 125 KVA / 100KW (Approx.).It should be air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard).ENGINE: The Diesel engine developing 155 BHP (Approx.) for giving a power rating as per ISO 8528- Part-1 (With CPCB-IV Norms amended upto date) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level, suitable self-starter for 12 V/ 24 V DC, battery charging alternator unit and voltage regulator, Lubrication oil cooler, Lubrication oil filters with replaceable elements.ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication, Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply.ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor: 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum dass insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use. |
| 581 | ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack. The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption. The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc. with 2 year warranty from the date of installation. complete in all respect as desired by engineer at site:-The Generator set should be instaaled at site on the suitable size existing plinth of RCC as per specifacation DG set as per satisfacation of the Engineer-in-Charge at site. The model of engine will be decided by the Engineer in Charge.MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HR fuses of suitable rating. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine. All the components in the control panel shall be properly mounted, duly wired and labeled.Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter, battery charger complete in all respect as desired by engineer at site:- |
| 582 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE): |
| 583 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part- 1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 584 | Overall size 120sq.mm (3½ Core) Un-armoured (Loose) |
| 585 | COPPER EARTHING: |
| 586 | COPPER EARTHING (Upto 8 metre in Length): |
| 587 | Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 588 | Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length) |
| 589 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: |
| 590 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 591 | Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender