Tender For Repair & Renovation Of 08 School Building Of C Bell Bay Namely Gsss C Bell Bay, Gps C Bell Bay, Gps C Bell Bay Jetty, Gps Rajiv Nagar Gms Govind Nagar, Gsss Vijayanagar, Gps Laxmi Nagar And Gps Chingen In Gni Project.

Issued by Government Departments · Nicobars, Andaman And Nicobar Islands
Tender Value
6.78 Crore
Estimated cost
Bid Submission
13 Oct 2026
16 days left
EMD
13.56 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nicobars → Andaman And Nicobar Islands
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair & Renovation Of 08 School Building Of C Bell Bay Namely Gsss C Bell Bay, Gps C Bell Bay, Gps C Bell Bay Jetty, Gps Rajiv Nagar Gms Govind Nagar, Gsss Vijayanagar, Gps Laxmi Nagar And Gps Chingen In Gni Project.

BOQ

Name of Work:- Repair & Renovation of 08 School Building of C bell Bay namely GSSS C bell Bay, GPS C bell Bay, GPS C bell Bay Jetty, GPS Rajiv Nagar GMS Govind Nagar, GSSS Vijayanagar, GPS Laxmi Nagar and GPS Chingen in GNI Project.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2All kinds of soil.
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:
51:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
61:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
71:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
8Centering and shuttering including strutting, propping etc.and removal of formwork for
9Foundations, footings, bases of columns, etc.
10Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
11Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth.
12Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
131:2:4 (1 cement:2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources)
14Centering and shuttering including strutting, propping etc. and removal of form for
15Foundations, footings, bases of columns, etc. for mass concrete
16Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
17Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement with1 :1.5:3 (1 cement: 1.5coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
18Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
19Thermo-Mechanically Treated bars of grade Fe-500D or more.
20Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
21Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.
22Float glass panes
234 mm thick glass pane (weight not less than 10 kg/sqm).
24Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
2535 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
2630 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
27Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
28Fixed to steel windows by welding
29Fixed to openings /wooden frames with rawl plugs screws etc.
30Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
31Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378)
32100x58x1.90 mm
33Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378)
34250x16 mm
35Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
36Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed torequired colour or shade, with nuts and screws etc. complete:
37300x16 mm
38250x16 mm
39Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
40250x10mm
41200x10 mm
42150x10mm
43100x10 mm
44Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
45125 mm
46100 mm
47Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
48Twin rubber stopper
49Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
50Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer- in-Charge.
51Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing.
5230 mm thick plain PVC door shutters
53Providing and fixing factory made uPVC glazed/ wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sashand mullion/ coupler (where ever required) extruded profiles having minimum wall thickness of 1.70mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part1 to 14, plastic packers, plastic cap sand necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/ mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcementand cross sections of uPVC profiles to be as per design approved by Engineer-in-Charage. Wiremesh/ Glazing of plain/ toughened/l aminated/ double glass unit with/ without high performance coatings as per design requirements and conforming to IS:3548 & IS:16231 shall be paid separately. Note:-Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed> 45 m/secas perIS875 — Part3 (ii)Sites with structure height more than 20m for all wind speeds
54Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
55Using R2 series with frame (40mm & above) x (40mm & above) & sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto1.2metre).
56Using R3 series with frame (55mm & above) x (40mm & above) & sash (30mm& above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system (Height upto 1.8m).
57Two track four panels sliding windows with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on three panels along with multi-point locking system, nylon rollers with SS 304 body.
58Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (55 mm & above) (Height upto 1.8m).
59Using R4 series with frame (64 mm & above) x (45 mm & above) & sash (44 mm & above) x (55 mm & above) (Height above 1.8m).
60Three track three panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
61Using R2 series with frame (70 mm & above) x (40 mm & above) & sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre).
62Using R4 series with frame (115 mm & above) x (45 mm & above) & sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on two end panels along with multi-point locking system. (Height above 1.8 metre).
63Two track four panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on three panels along with multi-point locking system, adjustable nylon rollers with SS 304 body.
64Using R3 series with frame (55mm & above) x (40mm & above) & sash (30mm & above) x (74mm& above). (Height upto 2.5 metre).
65Three track three panels sliding door with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on two panels along with multi-point locking system, adjustable nylon rollers with SS 304 body.
66Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (74mm & above). (Height upto 2.5 metre).
67Fixed window/ ventilator without mullion/ transom.
68Using R1 series with frame (33mm & above x (35mm & above). (Height upto 0.90 metre)
69Using R3 series with frame (55mm & above) x (45mm & above). (Height upto 2.5 metre)
70Fixed window/ ventilator with mullion /transom.
71Using R1 series with frame (33 mm & above) x (35 mm & above) & mullion (33 mm & above) x (50 mm & above). (Height upto 0.90 metre)
72Ventilator Casement window single panel with or without fixed panel with S.S. 304 friction hinges as per size and weight of sash, single point locking zinc alloy (zannak) powder coated handles.
73Using R1 series with frame (33 mm & above) x (35 mm & above) & sash /mullion (33 mm & above) x (50 mm & above). (Height upto 0.90 metre).
74Casement window double panels with fixed mullion with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles.
75Using R3 series with frame (55 mm & above) x (45 mm & above) & sash (55 mm & above) x (65 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 1.8 metre).
76Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/top hung uPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge.
77250 x 19 x 1.9 mm
78Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
79Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
80Extra for providing and fixing steel beading of size 10 x 10 x 1.6 mm (box type), approved shape and section with screws instead of glazing clips and metal sash putty, in steel doors, windows, ventilators and composite units.
81Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
82Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
83Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
84Hot finished welded type tubes
85Electric resistance or induction butt welded tubes
86Providing and fixing mild steel round holding down bolts with nuts and washerplates complete
87Providing and fixing bolts including nuts and washers complete.
88Providing and fixing carbon steel galvanised ( minimum coating 5 micron) (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
8910 x 80 mm
90Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :
914.0 mm thick glass panes
92Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
9340 mm thick with 20 mm nominal size stone aggregate
94Extra for making chequers of approved pattern on cement concrete floors, steps, landings, pavements etc.
95Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
96Medium shade pigment using 50% white cement 50% Grey cement
97Dark shade pigment using ordinary cement.
98Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
99Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement:4 Coarse sand), jointing with grey cementslurry@ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
100Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
101Glazed Vitrified tiles Matt/ Antiskid finish of size
102Size of Tile 600 x 600 mm
103Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.
104Size of Tile 500x500 mm
105Size of Tile 600x600 mm
106Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete :
1071.60 mm thick with zinc coating not less than 350 gm/m2
108Providing and fixing plain multipurpose cement board (Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).
1096 mm thick Cement fiber board as per IS: 14862
110Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
111Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
112Ridges plain (500 - 600mm)
11312 mm cement plaster of mix:
1141:4(1 cement: 4 fine sand)
1156 mm cement plaster of mix:
1161:3(1 cement :3 fine sand)
117Neat cement punning.
118Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
11912 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand):
120Flush Band
121Distempering with 1st quality acrylic distemper (readymixed) having VOC content less than 50gram/ litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour:
122New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50gram/litre
123Finishing walls with Acrylic Smooth exterior paint of required shade .
124New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm
125Applying priming coat:
126With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywoo
127With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
128Paintting with oil type wood preservative of approved brand and manufacture:
129New work (two or more coats)
130Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
131Two or more coats on new work
132Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
133Two or more coats on new work
134Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade:
135Two or more coats on new work
136Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
137Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
138Old work (one or more coats)
139Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
140With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre
141Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
142One or more coats on old work
143Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :
144One or more coats on old work.
145Finishing walls with Acrylic Smooth exterior paint of required shade :
146Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
147Old work (One or more coat applied @ 0.90 ltr/10 sqm)
148Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
149With cement mortar 1:4 (1 cement : 4 fine sand)
150With cement mortar 1:4 (1 cement : 4 coarse sand).
151Renewing glass panes, with wooden fillets wherever necessary:
152Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
153Providing and fixing bright finished brass hard drawn hooks and eyes :
154200 mm
155Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In- Charge.
156Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
157Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
158Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
159Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, hold fasts etc. complete and stacking within 50 metres lead:
160Of area 3 sq.metres and below
161Of area beyond 3 sq. metres
162Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead:
163Of area 3 sq. metres and below
164Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead :
165Of sectional area 40 square centimetres and above
166Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
167Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge.
168Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
169For thickness of tiles 10 mm to 25 mm
170For thickness of tiles above 25mm and upto 40mm
171Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
172G.S.Sheet
173Asbestos Cement sheet
174Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
175Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials nearthe site and disposal of unserviceable materials within 50 metres lead.
176Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required
177W.C. pan with ISI marked white solid plastic seat and lid
178Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
179Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
180Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
181White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
182White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
183Providing and fixing white vitreous china water closet squatting pan (Indian type) :
184Orissa pattern W.C. pan of size 580x440 mm
185Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fitting sand fixtures complete.
18610 litre capacity - White
187Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350mm or 340 x 410 x 265 mm sizes respectively.
188Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
189Semi rigid pipe
19032 mm dia
191Providing and fixing 100 mm sand cast Iron grating for gully trap.
192Providing and fixing 600 x 450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P.brass screw sand washers complete.
193Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall
19420 mm nominal dia Pipes
19525 mm nominal dia Pipes
196Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall
19715 mm dia nominal bore
198Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
19920 mm dia nominal bore
20025 mm dia nominal bore
201Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
20225 to 40 mm nominal bore
203Providing and fixing brass bib cock of approved quality :
20415 mm nominal bore
205Providing and fixing brass stop cock of approved quality :
20620 mm nominal bore
207Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
20825 mm nominal bore
20920 mm nominal bore
210Providing and fixing uplasticised PVC connection pipe with brass unions :
21130 cm length
21215 mm nominal bore
213Providing and fixing uplasticised PVC connection pipe with brass unions :
21445 cm length
21515 mm nominal bore
216Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
21720 mm nominal bore
21825 mm nominal bore
219Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
220Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931
22115 mm nominal bore
222Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
22315 mm nominal bore
224Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
22515 mm nominal bore
226Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms.
227Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
228Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge
229Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
230Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
231Providing and fixing in position facia and eaves board with 18mm thick wooden plastic compound (WPC) board 30cm wide sheet including fixing with nuts and bolts etc complete.
232Extra for Providing an fixing flat aluminium wind ties of 40x5 mm ( Weight 0.54 kg/mtr)
233Anodised aluminium (anodised transparent or dyed to required shade according toIS:1868, Minimum anodic coating of grade (AC 15).
234Constructing Cement Concrete 1:3:6 (1 : Cement : 3 Coarse sand : 6 Graded stone aggregate 40 mm nominal size) RCC top slab with 1:1.5:3 mix (1 : Cement : 1.5 Coarse sand : 3 Graded stone aggregate 20 mm nominal size) foundation concrete 1:4:8 mix (1 : Cement : 4 Coarse sand : 8 Graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 : Cement : 3 Coarse sand) finished with floating coat of neat cement and making channel in cement concrete 1:2:4 (1 : Cement : 2 Coarse sand : 4 Graded stone aggregatee 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design.
235Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg):
236Constructing soak pit 1.20 x 1.20 x 1.20 m filled with builbing rubbish, domolished concrete waste materials including uPVC pipe 110mm dia and 1.20 m long complete as per standard design.
237Providing and fixng soil, waste and vent UPVC pipe conforming to HSN code 3917 single socket type- B, including solvent joint etc, Complete as per the direction of Engineer-in-charge.
238110mm dia
239Providing and fixing UPVC (SWR) moulded fitting/ accessories conforming to HSN code 391740 including joint with solvent etc, Complete as per the direction of Engineer-in-charge.
240Plain bend of required degree 110 mm
241Providing and fixing G.I. Socket of 15 mm nominal bore diameter in G.I. pipes including threading, cutting, and jointing with pipe using approved threading compound complete as per specifications and direction of Engineer-in-charge.
242Providing and fixing 2 IN 1 C P Brass Bib cock with Health Faucet (Jaguar or equivalent) and flexible pipe of approved quality confirming t0 IS 8931. (15 mm nominal bore)
243Providing wood work in frames of doors, windowns, clerestory windows and other frames, wrought framed and fixed in position with hold fast or dash fasteners of required dia and length( hold fast lugs or dash fasteners shall be paid for separately)
244Superior hard wood Category- II (A)
245Providing and fixing 35mm thick glazed shutter for window with kiln seasoned and chemically treated superior hard wood cat-II (B) using 10 Kg/Sqm 4mm thick glass and stainless steel butt hinges and screws including the cost of panelling as per the direction of Engineer-in-charge. a) With Kiln seasoned and Chemically treated superior Hard wood Cat-II (A)
246Providing and fixing 35mm thick panelled, glazed or panelled & glazed shutters for door including anodised aluminium butt hinges with necessary screws and panelling with 12mm thick marine ply (BWR) conforming to relevant specification complete with wooden cleats & blocks as directed by Engineer in charge. a) With superior hard wood including seasoning and chemically treated ( Cat-II A )
247Providing Wood work in frames of trusess, purlins, rafters, ties post fixed in position etc. complete. Superior hard wood Cat-II (A) (Black Chuglam, Thingan, Toungpelnes, Pylnma, Koko and Mahwa).
248Providing and fixing 35 mm thick glazed shutters for doors, windows and clerestory windows using 10 kg/sqm (4mm thick) glass panes including anodised aluminium butt hinges(Anodix coating not less than grade AC 10 as per IS:1868) with necessary screw etc, complete.
249With Kiln seasoned and Chemicaly treated Superior Hardwood Cat-II(A)
250Providing and fixing glazing in wooden door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge
251Float glass panes
2524.0 mm thick glass panes (weight not lessthan 10 kg/sqm).
253Providing cement concrete surface drain including earth work in excavation 10 cm thick base concrete and 23 cm thick side walling with 1:3:6(1 cement: 3 sand : 6 graded stone agg. 40 mm nominal size) finishing with 1:4(1 cement : 4 sand) including floating coat of neat cement including drain and its top and exposed surface including earthwork in excavation and disposal of surplus earth etc., to complete a) 23 cm x 23 cm
254Providing and fixing CPVC ball valve of approved quality :as per the direction of Engineer-in-Charge.
25520 mm dia nominal
25625 mm dia nominal
257Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C
258Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
259Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
260a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
261b) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
262Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
263a) 5/6 A switch
264c) 15/16 A switch
265b) 3 pin 5/6 A socket outlet
266d) 6 pin 15/16 A socket outlet
267Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
268Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
269a) 3 Module (100mmX75mm)
270b) 6 Module (200 mm x 75 mm)
271Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
272Supplying and fixing brass batten/ angle holder including connection etc. as required.
273Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
274Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
275Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator)
276a) 16 way , Double door
277Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
278a) 8 way (4 + 24), Double door
279Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
280a)Single pole
281Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
282a)63 A
283Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete, connections, testing and commissioning etc. as required.
284a)40 A
285b)63 A
286Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
287Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
288Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
289Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
290Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
291Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
292Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ DWC pipe as required.
293Upto 35 sq. mm
294Above 35 sq. mm and upto 95 sq. mm
295Above 185 sq. mm and upto 400 sq. mm
296Supplying and fixing cable route marker with 10 cm X 10 cm X 5mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
297Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
29863 mm dia (OD-63 mm & ID-51 mm nominal)
299160 mm dia (OD-160 mm & ID-135 mm nominal)
300Supplying and fixing of 4 Pole MCCB of Make: Legrand , Model: DPX³ 160 MCCB 4P with breaking capacity of Icu 25 kA (400 V~), rated current of 160A with thermal magnetic protection unit as per legrand Cat No. 4200 57 or equivalent as incomer MCCB in the VTPN distribution board as required as directed by Engineer-in-charge
301Supplying and fixing of 3 Pole MCCB of Make: Legrand , Model: DPX³ 160 MCCB 3P with breaking capacity of Icu 16 kA (400 V~), rated current of 100A with thermal magnetic protection unit as per legrand Cat No. 4200 05 or equivalent as outgoing MCCB in the VTPN distribution board as required as directed by Engineer-in-charge
302Supplying and fixing of 8 way ( 8+24) double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of Make: Legrand , Model: Ekinox 507727 , 8 Way VTPN Distribution Board or equivalent conforming to IEC 61439-3, with 100 A Copper Busbar for each phase, With 2 Earthbar, 2 Neutral bar and Cable ties for Cable management, fully insulated busbar & shrouded Neutral bars , with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP/TP MCB's as outgoing i/c all connections and cable termination as required as directed by Engineer-in-charge
303SITC of indoor type, single front and floor mounted cubical panel board of size suitable size, preferably G-Frame Panel Board with enclosures, non extendable type L.T - 3 phase 440V , 320A Incoming Panel Board, 8 way with load bearing member & gland plate of 2mm thick CRCA MS Sheet, non-load bearing members of 1.6mm thick CRCA MS Sheet, IP54/IP56 Protection, with cable entry opening, terimination though cable alley, with copper bus bar of Current Density 1.0-1.2A/sqmm with 360A Capacity, earth and neutral busbar of suitable sizing having short circuit level of 36kA with colour coded heat shrinkable PVC sleeves, Powder coacted painting, with copper control wiring , CT, Power Wiring, bus bar supports, accessories and termination as required in complete shape and directed by Engineer in Charge.
304320 Amps , 4 Pole MCCB, 36kA Breaking Capacity of Make: Legrand DPX3 630, Model Code: 4220 06 or equivalent - 01 No.
305100 Amps , 4 Pole MCCB, 36kA Breaking Capacity of Make: Legrand DPX3 160, Model Code: 4200 95 or equivalent - 03 Nos.
30663 Amps , 4 Pole MCCB, 36kA Breaking Capacity of Make: Legrand DPX3 160, Model Code: 4200 93 or equivalent - 05 Nos.
307Meter Modules i/c indicator lamps, ON/TRIP lamps, Ammeter, Voltmeter, 02 Nos. Selector Switch for Ammeter and Voltmeter , 03 Nos. CT Coil 400/5 A Class, Control Fuse - 01 Unit
308Copper bus bar strip of rated load 360A - 01 Set
309Inter connection with PVC copper cable of suitable size etc. as required.-1 Job
310Supplying of following sizes of XLPE insulated armoured Aluminium conductor cable of 1.1 KV grade conforming to IS: 7098 (Part-I) and IS No. 1554 (Part-I) 1988 as applicable Make: CCI/ Gloster/ Havells/ Polycab/ Finolex as required as directed by Engineer-in-charge
311a) 25 Sq.mm x 4 Core
312b) 35 Sq.mm x 4 Core ( For 63A Outgoing Feeder )
313c) 70 Sq.mm x 4 Core ( for 100A Outgoing Feeder)
314d) 300 Sq.mm x 4 Core ( for 320A Incoming Feeder)
315Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in wall/ceiling along with clamping arrangemen as required in complete shape and directec by Engineer-in-charge
316a) 50 mm dia (OD-50 mm & ID-38 mm nominal)
317a) 63 mm dia (OD-63 mm & ID-50 mm nominal)
318Supplying of AC Ceiling Fan (1200 mm) Sweep with Socket Type Electronic regulator i/c wiring down rod of standard length (upto 30 cm) with all accessories etc., as required. Similar to make Crompton Empower 50 - 1 Star (ISI Marked) or its equivalent etc., as required as directed by Engineer-in-charge
319Supplying of prewired LED tube lamp 20 W Essential Bright Batten Similar to make Philips Cat :BN170C LED20S-6500 SU L120 or Similar in make :Havels,Syska ,Bajaj,Crompton. etc as required and directed in Engineer-in-charge
320Supplying, Installation, Testing and Commissioning of LED Bulkhead fitting 10W Similar to Havells HEXA 10 W Cat No. HEXAFT10WLED857SSYMBOPC or similar in bajaj, philips, crompton etc as suitable for indoor and outdoor applications as required and directed by Engineer-in-charge
321Supplying and Fixing of LED Lamp 10W B22 of Make:Havells LED Adore10W or similar etc., as required for Batten Holder as directed by Engineer-in-charge
322Supplying and Fixing of exhaust fan 200 mm sweep Light Duty Make:- Havells Smart Ventilair White Colour or similar etc complete with all accessories etc. asdirected by Engineer-in-charge
323Supplying and fixing of SMC Sintex box of inside dimension 350 mm x 250mm x 138 mm Code No. GSJB-3425, etc or equivalent make as required and directed by Engineer-in-charge
324Supplying and fixing of Fire Extinguisher ABC Powder extinguisher (ISI marked 6 Kg) capacity brand Lifeguard or Equivalent , wall bracket fixing with suitable , screws etc. as reqd. ISI marked Confirming to ISI 15683:2016 along with Fire Fighting Equipment Certificate for Test and Warranty as required as directed by Engineer-in-charge
325Supplying and fixing of ISI marked CO2 type Fire extinguisher of 4.5 Kg(catridge type) brand Lifeguard or Equivalent fitted with control valve and high pressure 1 mtr long discharge hose and horn complete with initial gas charge with carrying handle and wall mounting bracket, fixing with suitable, screws etc. Confirming to ISI 15683:2016 along with Fire Fighting Equipment Certificate for Test and Warranty as required as directed by Engineer-in-charge
326Replacement of non-functioning AC Ceiling Fan (1200 mm) Sweep with new one i/c connections ,all accessories etc as required. Similar to make Crompton Empower 50 - 1 Star (ISI Marked) or its equivalent etc., as required as directed by Engineer-in-charge
327Replacement of non-functioning LED tube lamp batten with new one Similar to make Philips Cat :BN170C LED20S-6500 SU L120, 20W or Similar in make :Havels,Syska ,Bajaj,Crompton. etc as required and directed in Engineer-in-charge
328Replacement of non-functioning LED Bulb with new one of Make:Havells LED Adore10W or similar etc., as required for Batten Holder as directed by Engineer-in-charge
329SITC of LED Solar Light of Make: Philies 25W LWD Solar Street Light, Model: BRC010 LED40S/765 All-in-One Solar Street Light for Energy-Efficient Outdoor Lighting, Cool White 6500K, IP65 Waterproof or equivalent i/c all accessories on the exisiting streetlight poles as required as directed by Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57682691
AUTHORITY Government Departments
TENDER VALUE 6.78 Crore
LAST DATE 13-10-2026
Authority
Authority Name Andaman Public Works Dept
Work Description Tender for Repair & Renovation Of 08 School Building Of C Bell Bay Namely Gsss C Bell Bay, Gps C Bell Bay, Gps C Bell Bay Jetty, Gps Rajiv Nagar Gms Govind Nagar, Gsss Vijayanagar, Gps Laxmi Nagar And Gps Chingen In Gni Project.
Basic Detail
Tender No 23/EE/CD/CB/2026-27
Bidding Type Tender
Location
City Nicobars
State Andaman And Nicobar Islands
Key Dates
Publish Date 24 Sep 2026
Submission Date 13 Oct 2026
Open Date 14 Oct 2026
Finance
Tender Value 6.78 Crore
Tender Fee Ref. Documents
EMD 13.56 Lakhs
Exemption Not Available
Document List
5dad82d5-ca10-4fc1-8995-cb5a9d2c882e.html
BOQ_26259.xls
Instructions-to-bidders.pdf
Tenderdocumentallschool.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Oct 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

5dad82d5-ca10-4fc1-8995-cb5a9d2c882e.html

xls

BOQ_26259.xls

pdf

Instructions-to-bidders.pdf

pdf

Tenderdocumentallschool.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders