Public Administrative Department Local Bodies Closing in 13 days TDR #57680919

Tender For Repair And Maintenance Of All Electrical, Mechanical And Civil Installations Along With Comprehensive Operation, Maintenance And Upkeep Of All Electrical, Mechanical And Allied System/Installations For A Period Of Five Years In The Multi-L

Issued by Local Bodies · Delhi, Delhi
Tender Value
4.41 Crore
Estimated cost
Bid Submission
08 Oct 2026
13 days left
EMD
8.83 Lakhs
Bank guarantee accepted
Document Fee
1770
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of All Electrical, Mechanical And Civil Installations Along With Comprehensive Operation, Maintenance And Upkeep Of All Electrical, Mechanical And Allied System/Installations For A Period Of Five Years In The Multi-Level Underground (Mlug) Car Parking At Model Town Under Keshav Puram Zone.

BOQ

Name of Work:- Repair and maintenance of all Electrical, Mechanical and civil installations along with comprehensive operation, maintenance and upkeep of all Electrical, mechanical and allied system/installations for a period of five years in the Multi-level underground (MLUG) car parking at Model town under Keshav puram zone.
Sl. No. Item Description
1SECTION-1: Electrical Installations
2Complete Repair and Servicing of 2nos. 125 KVA DG Set (make: Cummins) i/c repair and Painting of Canopy complete with all Spares, accessories etc as reqd.
3Complete Repair and Servicing of 2nos. 25 KVA DG Set (make: Cummins) i/c repair and Painting of Canopy complete with all Spares, accessories etc as reqd.
4Earthing with GI earth plate 600x600x6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc.(but without charcoal/ coke and salt) as required.
5Earthing with copper earth plate 600x600x3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc.(but without charcoal/ coke and salt) as required.
6Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
7Providing and fixing of 25mm X 5mm Copper strip in surface or in recess connections etc. as required
8Providing and fixing of 25mm X 5mm GI strip on surface or in recess for connections etc. as required
9Providing and fixing of 25mm X 5mm Copper strip in 40mm dia G.I pipe from earth electrode i/c connection with GI nut, bolts, spring , washers excavation and re-filling etc as required
10Providing and fixing of 25mm X 5mm GI strip in 40mm dia G.I pipe from earth electrode i/c connection with GI nut, bolts, spring , washers excavation and re-filling etc as required
11Providing and fixing 6SWG G.I wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
12Supply, installation, testing and commissioning of 160 KVA capacity (continuous loading) 11/0.433 KV Delta/Star, step down, 3 Phase, 50 Hz, Dyn 11 vector group, Cast Resin / VPI (vacuum pressure impregnated) Dry Type, copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better) AN (air natural) cooled transformer suitable for indoor applications with Offload Tap Changer/ On Load Tap Changer (OLTC) ( upto 500 KVA offload and above 500 KVA On Load Tap Changer) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, insulation class F (minimum), suitable for environment conditions class E4, suitable for fire behaviour class F1, climate class-C1, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade with necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers, bus trunking arrangement on LV side complete with all accessories and safety provisions as per relevant IS Code, The transformer shall be provided with standard fittings/accessories as per relevant IS and mentioned below, protection alarm/tri protection, 3 nos. of Polymeric Zinc Oxide surg Arrestors on HV Side. Winding Temperature scanne (Digital) with alarm/Trip contacts with RTD Sensors per LV winding and space for mounting differential protection CT's in LV chamber with neutral brought out separately including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/HT Panel for safety tripping, complete as confirming to IS-2026 Part-11, i/c supplying and grouting of suitable M.S. Channel with all accessories, complete in all respects as required at site as per CPWD specifications. Design ambient condition: a) air temperature 50 °C, b) Relative Humidity 90% Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. The transformer should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. All testing shall as per relevant IS Code. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551/NEMA Standard. Fitting and Accessories: The following fittings shall be provided: a) Two earthing terminals with the earthing symbol b) Rating and terminal marking plates; c) Thermometer pocket with cap; d) Lifting lugs for the complete transformer as well as for core and winding assembly; e) Bi-directional flat rollers (for transformers above 200 kVA); f) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); g) Arcing horns or suitable rating lightning arrestors for HT side 3 Nos. for transformers up to 200 kVA; h) Bird guard; i) Jacking pads (for transformer above 1 600 kVA); j) Name Rating & Diagram Plate. k) Monogram Plate.i) Additional neutral separately brought out on bushing for earthing Level 3, 160 KVA (losses at 50% loading <770watt, losses at 100% loading < 2200watt).
13Supply of 11 KV grade XLPE (E) insulated and PVC sheathed armoured aluminium conductor cable as required conforming to technical specifications. 3C x 185 sqmm.
14Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size. A 2C x 6 Sqmm
15B 2 x 10 sq.mm
16C 4 x 25 sq.mm
17D 3.5c x 35 sq.mm
18E 3.5c x 50 sq.mm
19F 3.5c x 95 sq.mm
20G 3.5c x 150 sq.mm
21H 3.5c x 240 sq.mm
22Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.A Upto 35 sq. mm
23B Above 35 sq. mm and upto 95 sq. mm
24C Above 95 sq. mm and upto 185 sq. mm
25D Above 185 sq. mm and upto 400 sq. mm
26Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.A Upto 35 sq. mm
27B Above 95 sq. mm and upto 185 sq. mm
28Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required:Upto 35 sq. mm (clamped with 1mm thick saddle)
29B Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
30C Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
31D Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
32Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.A Upto 35 sq. mm (clamped with 1mm thick saddle)
33B Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
34C Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
35D Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
36Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
37Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
38Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. A 2 X 10 sq. mm (19mm)
39B 4 X 25 sq. mm (28mm)
40C 3½ X 35 sq. mm (32mm)
41D 3½ X 50 sq. mm (35mm)
42E 3½ X 95 sq. mm (45mm)
43Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.A 150 mm width X 50 mm depth X 1.6 mm thickness
44B 300mm width X 50mm depth X 1.6mm
45C 450mm width X 62.5mm depth X 2.0mm
46Supplying and fixing of following ways surface/ recess mounting, vertical type 415 volts, TPN MCB distribution board of sheet steel, dust protected,duly powder painted, inclusive of 200 amps tinned copper bus bar,common neutral link,earth bar, din bar for mounting MCB's, (but without MCB's and incomer) as required. A 4 way( 4+12 ), Double door
47B 8 way ( 4+24 ), Double door
48Supplying and fixing 5 A to 32 A rating Single pole, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required
49Supplying and fixing 63Amp rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
50Supply of corrugated & chequered rubber mat for electrical purposes exceeding IS: 5424/69 Black or red in 1M X 2M of size 25 mm thickness
51Supplying and fixing of signages on aluminium sheet 2.0 mm (+-10%) fixing on wall/ceiling complete in all respect a) safety instruction chart in word.
52SITC of 3mm (Min.) ACP sheet based, acrylic Raised letters LED board with 1\\"x1\\" M.S. square pipe box type frame, pipe frame all open sides covered by G.I. Sheet properly.
53Providing & fixing M.V. Danger notice plate of 200 mm x 150 mm, made of mild steel at least 2mm thick and vitreous enameled white on both sides, and with inscriptions in signal red colour on front side as required.
54Providing & fixing H.T. Danger notice plate of 250 mm x 200 mm, made of mild steel at least 2mm thick and vitreous enameled white on both sides, and with inscriptions in signal red colour on front side as required.
55Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed steel conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
56Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
57Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.A 3 x 1.5 sq mm
58B 3 x 2.5 sq mm
59C 3 x 4 sq mm
60D 3 x 6 sq mm
61Supplying and fixing of 25mm sizes of steel conduit long with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
62Supplying and fixing of 25mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
63Supplying and fixing following size/modules,GI box along with modular base & cover plate for modular switch in recess etc.as required., 1 or 2 Module (75mm X 75mm)
64Supplying and fixing following size/modules,GI box along with modular base & cover plate for modular switch in recess etc.as required., 4Module (125mm X 75mm)
65Supplying and fixing following size/modules,GI box along with modular base & cover plate for modular switch in recess etc.as required., 6Module (200mm X 75mm)
66Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connection but excluding modular plate etc.as required., 5/6 amps switch
67Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connection but excluding modular plate etc.as required., 15/16 amps switch
68Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connection but excluding modular plate etc.as required., 3 pin 5/6 amps socket outlet
69Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connection but excluding modular plate etc.as required., 6 pin 15/16 amps socket outlet
70Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate etc.as required.
71Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS: 10322 with driver as per the requirement with Driver efficiency > 85% Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD <10%, P. F .>=0.95. IP20, CRI >= 80 , UGR (Unified Glare Rating) <= 19 , Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000 deg * K / 4000 deg * K / 5700 deg * K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing, complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >= 120 <135 Im/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90 deg * C ) ,Powder Coated CRCA Sheet Body (Thickness > 0.50 mm), 36 Watt.
72Supplying, Installation, Testing & Commissioning of 45 watt Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66.IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 Im/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
73LED Batten light (System lumen efficacy ≥120 <135 Im/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS 10322 with driver (Replaceable) as per the requirement Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C. internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.20.95, IP20, CRI ≥80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K/5700°K /6500°K(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 Im/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).,Powder Coated CRCA Sheet Body (Thickness > 0.50 mm), 18-22 watt
74LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt)Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) 50Watt
75P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
76Fabrication, supply & erection of 4.0 mtr height minimum 3 mm thick bottom dia of 130 mm and to dia of 70 mm base plate of size 225x225x12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor - 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB 'C' characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS. code etc as reqd.
77Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L) x450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1400 mm (approx) -6 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 16 mm dia,600 mm long, J type i/c 2 nos. template anchor plates of size 225mmx225mmx3mm and providing DCW HDPE for cable entry and exit as required for 3 m and 5 mtr pole.
78Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap and 250 mm long 32 mm dia galvanised pipe with tightening bolts complete as required.
79Fabrication, supplying and fixing class B galvanised double overhang arm bracket made out of 250mm long galvanised top tube with cap and 250mm long 32 mm dia galvanised pipes with tightening bolts complete as required.
80:Fabrication, supplying, installation, testing and commissioning of openable Signage made of electrocut computerised automated individual letters in hindi & English, total Covering Area and design as per direction of Engineer in charge, Letters to be made from powder coated sheet with 100-150 mm bottom profiles bended along 4-5mm thick sheet of unbreakable Acrylic Sheet to be used in front which will be pinned to the profile. Approved Color, Vinyl (UV) to be used for Colorful look on the front of Acrylic sheet, Letters back should be duly powder coated/painted with Primer & two coats of approved Color Enamel or Duco paint. The signage shall have a system for easy graphic changes and easy access for maintenance. The illumination source shall be of LEDs or approved equivalent modules with individual current regulator/power supply driver module for every signage complete with all internal wiring etc along with connectors for connections to achieve required and uniform illuminations,specifications and design as per the directions of Engineer in charge. LED specification :Lumen output : 2500 lumens/sqmtr (minimum) radiance angle : 120 degree and above Illumination should be uniform and suitable arrangement should be made for installation of the whole structure using Gi pipes, angles etc but excluding foundation work.
81SECTION-2: CCTV
82Supplying Installation Testing and Commissioning of 4MP IP IR Dome Camera having following specifications and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB, Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.7234) Wide Dynamic Range:- WDR (120dB or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps , Sub streams minimum: 720P@25/30 fps7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption IP/MAC filtering, HTTPS, trusted upgrade9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.10) Recording Management: Format SD, overwrite, storage management, video to NAS device,11) Alarm Trigger Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection12) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPOE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,13) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port
8315) Audio: It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input-12 VDC (via power adapter) and PoE (802.3af) to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VDC/POE (802.3af)/ePoE18) Housing/ Enclosure: IP67 weather proof, IK10, Metallic body19) Operating Condition: Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 4MP @ 25/30fps@1440P (2560 x 1440) Dome Camera with 2.8/ 3.6/ 6/8/12 mm fixed lens (as per site requirement).
844MP IP IR Outdoor Bullet CameraSupplying Installation Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera having following specifications and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB, Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition (Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum): Video: H.265-or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.7234) Wide Dynamic Range:- WDR (120dB or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming configurable Main stream: 4MP (2560×1440)25/30fps Sub streams minimum: 720P@25/30 fps7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.10) Recording Management: Format SD, overwrite, storage management, video to NAS device,11) Alarm Trigger: Motion/tampering detection network disconnection detection; IP conflict detection; memory card state detection; memory space detection12) Network Protocol: SFTP, IPv6, IPv4, DNS, RTCP, NTP, RTP, HTTP, HTTPS, SNMP-TCP/IP, PPPOE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,13) System Capability: ONVIF, Camera shall support open source VMS
8514) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio: It should support 1 x Built-In Mic and 1/1 Alarm In/Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input-12 VDC (via power adapter) and PoE (802.3af) to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE18) Housing/ Enclosure: IP67 weather proof, IK10,Metallic body19) Operating Condition: Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS4MP @ 25/30fps@1440P (2560 x 1440) Outdoor Bullet Camera with 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement)
86Supplying Installation Testing and Commissioning of 16 Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below:1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth.2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support3) Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk4) Intelligent auto power on when power resumes after power outage5) Storage: It should support minimum 2 SATA Slots with 16TB capacity/ Slot.6) Connectivity Interface: 1 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS2327) Backup Interface: Its should have 2 Nosx USB port (1x USB3.0, 1xUSB2.0)8) Video Output Ports: 1x HDMI and 1 VGA9) Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic11) Web & Mobile Application: Web, Mobile app (For iPhone, iPad, Android Phone) for alerts and viewing.12) Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S. Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need.13) Standards: CE, FCC, RoHS and BIS Certified14) Power Supply: Should support 12VDC, 4Amp or AC100-240V, 50/60Hz Power supply.15) Operating Condition: Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing)16) The VMS, NVR application shall support all the features & functionalities of the offered cameras.
8717) VMS should consist of Base license and Channel Licenses. VMS should be provided with camera Licenses, with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage 19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20) Must support Resolution: 7680x4320 (8K), 3840*2160, 1920×1080, 1280×1024,1280×720, 1024×76821) Must support recording resolution upto 32MP22) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode23) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page24) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email. address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm25) It should support Network Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting. Convert multiple recording files to one avi/MP4 file.26) General Al Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.27) Alarm Notifications based on Motion detection video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan
8828) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 29) Built-In Artificial Intelligence: NVR should have Al :-built-in 2 Channel face detection and recognition, Minimum 4 Channel perimeter protection, Minimum 8 Channel Smart Motion Detection30) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec.31) Face & Human Attributes Search: Search Pictures/Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.32) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes.33) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception34) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.35) General Al Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection,Violence Detection.36) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency37) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics for 16 Channel Network Video Recorder (NVR) having display split: Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16
89Supplying, Installation, Testing and Commissioning of 42 inch size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available. contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°% 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system). Key Board, Optical Mouse, etc. as required.
90Hard Disk DriveSupplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 6 TB
91Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range: -5° to +60°C, Bending Radius: < 4 X Cable Diameter at -5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.A One run of cable
92B Two run of cable
93C Three run of cable
94SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch
95Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN//DE. The operating efficiency of the UPS systems shall be ≥95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 °C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3). The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo-Tag of manufacturing location etc 3KVA
96Supplying and fixing 24U Rack with 4 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.25mm Powder Coated CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 5nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required
97Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 6U Rack
98SITC of IP65 box (without PoE switches) of dimention 310mmX160mmX140 mm on pole or wall with suitable arrangement for support/installation of 8 port Giga PoE switch and 1 no. 15/16 amp modular switch socket set
99SECTION-3: Fire Fighting
100Supplying and fixing of single headed internal hydrant valve with instantaneous Gun metal/stainless steel couplings of 63mm dia with cast iron wheel ISI marked conforming to IS:5290 (Type A) with blank Gun metal/stainless steel cap and chain as required. single headed Gun metal
101Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585(b) 20 mm nominal internal dia gun metal globe valve & nozzle.(c) Drum and brackets for fixing the equipmets on wall.(d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 Mtrs.
102Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with Gl wire, rivets etc. conforming to IS 636 (type-A) as required: Stainless steel (Grade 304)
103Providing & fixing 63 mm dia Gun-metal branch pipe with 20 mm (nominal internal diameter) size Gunmetal nozzle conforming to IS:903, suitable for instantaneous connection to interconnect hose pipe coupling as required. Stainless steel (Grade 304)
104Providing and fixing , testing and commissioning of butterfly valve of rating PN 1.6 with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets, conforming to I.S:13095 of following sizes as required. 150mm dia
105Supplying & fixing Fire Brigade connection of cast iron body with Gunmetal male instantaneous inlet couplings complete with cap and chain as required for for suitable dia MS pipe connection, conforming to IS:904 as required. Three Way - 150 mm dia MS pipe
106Supplying & fixing Fire Brigade connection of cast iron body with Gunmetal male instantaneous inlet couplings complete with cap and chain as required for for suitable dia MS pipe connection, conforming to IS:904 as required. Four Way- 150 mm dia MS pipe
107Supplying, fixing and testing of hose cabinet of size 30\\"X24\\"X 10\\" made of 2mm thick MS sheet with 6mm thick glazed glass doors i/c necessory locking arrangements suitable to accommodate external hydrant with sluice valve, 2nos- 15mtr long hose pipe, 1no- branch pipe, mounted on the wall OR raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect as regd
108Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
109Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 150 mm
110Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
111Providing, installation, testing and commissioning of gun metal valves of following sizes as reqd. a 25 mm dia
112providing and fixing 0-14 Kg pressure gauge complete as required
113Providing and fixing ABC (Aluminium Phosphate) Power type fire extinguisher of 6 kgs capacity complete in all respect with ISI mark i/c fixing arrangement etc as required.
114supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged)
115Providing, laying , Testing & Commissioning of \\"C' class heavy duty Mild Steel pipe conforming to IS 3589/IS 1239 including welding fittings like tees, elbows, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of reqd shade complete as reqd.A 200 mm dia
116B 150 mm dia
117C 100 mm dia
118D 80 mm dia
119E 65 mm dia
120F 50 mm dia
121G 40 mm dia
122H 32 mm dia
123I 25 mm dia
124Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 Deg.C with required accessories.A Pendent type
125B Horizontal Side Wall sprinkler
126Providing, fixing testing and commmissioning of Installation Control Valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges,emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc. of 150 mm dia as required.
127(a) Supplying, testing installation, and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required:(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018.(d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e)Suitable cement concrete foundation duly plastered with anti vibration pads .Rating 2280 lpm at 56 meter Head. Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point
128(a) Supplying, installation, testing commissioning of electric driven pressurisation pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required (Jockey Pump)(b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required(C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018(d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads.Rating 180 lpm at 56 m Head
129Providing and fixing, testing and commissioning of stainless steel strainer 200mm dia fabricated out of 1.6mm thick stainless steel sheet with 3 mm. dia holes with stainless steel flange, ( tested at 20Kg/cm2) complete including nuts, bolts, gaskets etc as required.
130Providing and fixing , testing and commissioning of butterfly valve of rating PN 1.6 with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets, conforming to I.S:13095200mm dia (gear operated)
131B 150mm dia
132C 80mm dia
133Providing and fixing , testing and commissioning of dual plate non return valve of following sizes conforming to I.S: 5312 of rating PN 1.6 complete with rubber gaskets, nuts, GI bolts, washers, etc.as required.A 150mm dia
134B 80mm dia
135Providing and fixing of suitable flexible neoprene rubber expansion joint, single arch with integral rubber flanges tested at 20 Kg/cm2 with SRR drilled as per BS-10, Table-D, complete ec as reqd. of following sizesA 200mm dia
136B 150mm dia
137C 80mm dia
138Supplying and fixing of signages on aluminium sheet 2.0 mm (+-10%) fixing on wall/ceiling complete in all respect a) safety instruction chart in word.
139SITC of 3 mm (Min) ACP sheet based acrylic raised letters LED board with 1\\"X1\\" M.S. square pipe box type frame, pipe frame all open sides covered by G.I sheet properly
140Supply of lead acid battery 180 AH fully charged etc as complete as required (warranty 24 months.)
141Supply of Submersible Sewage Pump 2 HP/1.5 KW/3 Phase/2800 RPM, Disharge and Head not less than 10 mtr head and 250 LPM discharge, 50mm Hose Outlet Solid Handling:35 mm Casing: Cast iron ASTM A48 Class 30 (FG 200) Shaft:431 Stainless steel Hardware: 304 stainless steel 'O' rings: Nitride rubber Mech. seals: TC/TC (Upper & Lower) Cable: Waterproof/oil proof EPR insulated double sheathed copper conductor flexible cable fitted with strain relief grip. 15 mtr length of 6 core. (4 core of 1.5 sqmm + 2core of 1 sq mm)
142Supply, Installation, Testing, and Commissioning of a Clean Agent Gas-Based Fire Suppression System suitable for enclosed spaces such as electric panels, closed cabinets, and server racks. The system includes the following components and features: Clean Agent Gas Suppression System Suitable for up to 2 cubic meter volume, Clean Agent Type: FK-5-1-12 with zero Ozone Depleting Potential (ODP), Electrical non-conductive and environmentally safe gas, Capacity. 2 kg seamless cylinder (PESO Approved) with nickel-plated brass valve with gauge and heat sensing tubing providing automatic discharge under 10 sec. Pre-pressurized to 13/16 bar at 21 degree celcius. Storage and Operating temperature range -20 degree celcius to +60 degree celcius. Fire detection tube: Pneumatic Heat detection tube made by special modified poly-amide (PA), UL approved, having burst temperature +100°C to +120°C, inner diameter 4 mm, outer diameter 6 mm, pressurized with nitrogen at 15 to 18 bar pressure for automatic detection and suppression system etc. End of line adapter along with pressure gauge working pressure 25 bar (UL approved/Peso approved). T- connector: T connection suitable for 4/6 mm. diameter pressurized tubes, brass nickel plated material with maximum working Nos. 0 bar pressure to 25 bar pressure (UL approved/Peso approved). fittings are made by brass/stainless steel. End of Line Plug: used for fitting at tube end to terminate the point. Fitting made by brass nickel plated material. Pressure Switch to monitor Pressure drop in the tube and able to work at 15 bars. Micro processor based hybrid master control unit for connecting each system with electronic hooters and productivity input to Scada/Fire Alarm System including all necessary connections, Power backup: 12V, 7.2 Ah SMF batteries (2 nos.), Real time event log stores. Operating Pressure: 15 bar, Max Working Pressure: 20 bar, Burst Pressure: 100-120°C, Operating Temperature Range: -20°C to +60°C, etc. complete with all the accessories as required, LPCB Standard Certification: LPS 1666: Issue 1.0, Valve Certification: TPED certificate (EN ISO 10297:2006/CE Marked), Test Reports and OEM marking included, Warranty: 3 years
143Section-4: Fire Alarm
144Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. 10 loop panel
145Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required
146Supplying, installation, testing & commissioning of fire fighter telephone headset complete as required
147Supplying, installation, testing & commissioning of fire fighter phone jack complete as required
148Supplying, installation, testing & commissioning of fault isolator complete with base as required
149Supplying, installation, testing & commissioning of addressable fire control module complete as required
150Supplying, installation, testing & commissioning of addressable phone control module complete as required
151Supplying, installation, testing & commissioning of addressable manual call point complete as required.
152Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
153Supply, Installation, Testing and Commissioning of pure IP at core server based voice solution 20 IP users License, 01 Nos. IP Operator Console ,Speed Dial, Music on Hold, Internal/ External ring difference ,Call Barring, Call Pickup, T, Should Support with all accessories complete as reqd.
154Supply, Installation, Testing & Commissioning of CAT6A U/UTP information outlet (I/O) I/O Faceplates with box, 1 port configurations, design for better aesthetics , Cover and Base Plastic Material 86 x 86mm for I/O fixing at user side etc. complete as required.
155Supply, Installation, Testing & Commissioning of loaded Cat6A 24-Port 1U Universal Modular Straight Patch Panel preloaded with cable support Bar (with slots to tie individual cable properly at the Support Bar), Stainless Steel Rear Metal Frame, Individual Port Transparent Shutter and Labelling, , RoHS Compliant, Individually Replaceable Port IO, for CAT6A cable termination at rack end etc. complete as required.
156Supply, Installation, Testing & Commissioning of CAT6A LSZH patch cord U/UTP Unshielded 24AWG Bare Copper Stranded Flexible Conductor, 1 Mtr for rack side switch to jack panel connectivity etc. complete as required.
157Supply, Installation, Testing & Commissioning of CAT6A LSZH patch cord U/UTP Unshielded 24AWG Bare Copper Stranded Flexible Conductor, 2 Mtr from IO to end user connectivity etc. complete as required.
158SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100/1000) slot long distance switch complete as reqd.
159Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 6U Rack
160Supplying and fixing of following sizes of medium class PVC conduit /baton along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25 MM
161Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range: -5° to +60°C, Bending Radius: < 4 X Cable Diameter at -5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. A One run of cable
162B Two run of cable
163C Three run of cable
164Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
165Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required
166Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
167Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface /recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.A speaker cable single pair, 2-core, 1.5 sqmm
168B speaker cable Two pair, 2-core, 1.5 sqmm
169C speaker cable Three pair, 2-core, 1.5 sqmm
170Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required.
171Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
172Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
173Supplying Installation Testing Commissioning of Client PC System comprising of PC Hardware with minimum11th Gen Intel® 17 processor CPU E5-2640 x64 (or better), compatible with dual and quad core processors minimum 3.1 Ghz and 8GB or higher RAM, Hard Drive Space of 256 GB SSD or better, Video card and monitor capable of 1920 x 1080 pixel resolution or better with Ethernet adapter (10/100/1000 Mbps with RJ-45 connector) with 2 GB or higher Graphics card suitable for BMS System complete etc. as required.
174Supplying, Installation, Testing and Commissioning of 42 inch size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available. contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°% 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system). Key Board, Optical Mouse, etc. as required.
175Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP4 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
176Supplying, installation, testing & commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required
177Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required
178Supplying, Installation, Testing and Commissioning of SIM Based Industrial Cellular Router with dual SIM support, 4G LTE/5G connectivity, minimum 2 x Gigabit LAN ports and 1 x Gigabit WAN port, VPN (IPSec/OpenVPN/L2TP/PPTP), Firewall, VLAN, QoS, DHCP, IPv4/IPv6, SNMP, HTTPS, SSH, remote cloud management, automatic SIM failover, Network Address Translation (NAT), Port Forwarding, Virtual Server, DMZ, Dynamic DNS (DDNS), Static Routing and secure remote access for field devices and surveillance systems, industrial operating temperature (-20°C to +60°C), dual power input, LTE antennas, surge protection, DIN rail mounting, CE/FCC/RoHS certified, complete with all accessories, installation, testing and commissioning as required.
179Section-5: BMS
180Supplying Installation Testing Commissioning of Central Control Server System comprising of Intel® Xeon® CPU E5-2640 x64 (or better) compatible with dual and quad core processors, Windows 11 (Professional, Enterprise, Ultimate, 64 bit), Windows Server 2013 R2 (Standard, Enterprise, 64 bit) 16 GB or more, Video card and monitor capable of displaying at 1024 x 768 resolution or better. Latest Microsoft Licence Version Operating System Loaded with MS OFFICE 2019 Professional, Word, EXCEL, Power Point, Outlook Express, Microsoft Team official version lifetime licences suitable for running BMS software complete etc. as required.
181Supplying Installation Testing Commissioning of LaserJet printer having printing resolution 1200 X 1200 dpi, (dot/inch) or better, 21 to 30 ppm printing speed (LaserJet) complete etc. as required
182Supplying Installation Testing Commissioning of Client PC System comprising of PC Hardware with minimum11th Gen Intel® 17 processor CPU E5-2640 x64 (or better), compatible with dual and quad core processors minimum 3.1 Ghz and 8GB or higher RAM, Hard Drive Space of 256 GB SSD or better, Video card and monitor capable of 1920 x 1080 pixel resolution or better with Ethernet adapter (10/100/1000 Mbps with RJ-45 connector) with 2 GB or higher Graphics card suitable for BMS System complete etc. as required.
183Supplying Installation Testing Commissioning of Necessary Software (UL listed) Packages containing Building Management with Capability of Collection, Storage, Processing and Controlling all the Data. Software shall support Open Standard Protocols like XML, BACnet, Modbus, Lon works etc. and without the use of Proprietary Protocols, with Enterprise Level Database Like MS SQL complete Lifetime Licenced & capable to collect, store & access all points from Fire Alarm Systems, IT Systems, Automation Systems, HVAC System, Lift, Energy management, Water Management System, etc. to create & monitor historical & event data, event management data, alarm management data & reporting data, Email Alerts for Critical alarms for all the systems. The scope includes additional software required by BMS software (to enable a standard Web browser) to be resident on the DDC/client machine (manufacture-specific browsers shall not be acceptable). User log-on identification and password shall be required & a minimum three-layered security system(User interface Level, Application Level and Data Base Level) to be deployed for safety. The supplied computer software shall employ object-oriented technology (OOT) for representation of all data and control devices within the system. This data shall reside on a server for all database access (Systems requiring proprietary database and user interface programs shall not be acceptable). All components and controllers supplied under this contract shall be true \\"peer-to-peer\\" communicating devices (Components or controllers requiring \\"polling\\" by a Master / Global / Host to pass data shall NOT be acceptable). Physical connection of BACnet/MOD BUS devices shall be via Ethernet at all levels. The License must be provided by default. The BMS software shall be complete in all respect to cater the following different numbers of points managed in the installation. upto 500 points included.
184Supplying Installation Testing Commissioning of IP Based DDC controller capable of fully \\"stand alone\\" operation i.e. In the event of loss of communication with other DDC's or Control Station, they shall be able to function on their own. The controllers shall consist of dual/quad core 32 bit microprocessors with EPROM based operating system on BACNET. The network Topology shall not allow single point failure. Each DDC on field level shall have embedded TCP/IP (10/100Mbps) connectivity so that it can be hooked into the Local Area Network (LAN) provided by the client or on dedicated network Each DDC can be accessed from the Graphical User Interface (GUI) or from a standard Web browser (WBI) by connecting the server alongwith inbuilt web browser. All controllers shall accept 230V+/- 10%, 50Hz Uninterrupted power supply provided by end user. Controller shall support DHCP addressing over Local Area Network (LAN) so that the static IP requirements get reduced however a single static IP shall be provided for system so that it can be hosted on to internet in consultation with end user. The microprocessor based DDC's shall be provided with power supply, analoge to Digital and Digital to analoge converters with memory and capacity to accommodate input/output (I/O) hardware points (with or without an expansion board). Each DDC should have own board and shall accept 0-10 V/4-20mA input signal having Minimum 20% spare capacity considered for expansion. Each DDC on field level should have minimum 128MB RAM & 64MB Flash memory. Following type of All controllers should be mandatorily BTL approved with B-BC profile complete etc. as required. DDC controller-type-l (Support upto 32 points)
185Supplying Installation Testing Commissioning of following sizes Powder coated wall mounted lockable and secure enclosure for DDC panel made of 16 SWG sheet steel IP -55 rated with proper internal mounting accessories for DDC such as DIN Rails, terminal block for cable terminations, well dressed for all internal cabling, ferruling, tagging etc. The DDC panels shall have power supply and connections for other peripheral equipment, switchgear protections, isolation transformer, earthing, relays, fuses, auxiliary power output socket & lamp etc. as required 500mmX500mmX200mm
186Supplying Installation Testing Commissioning of following sizes Touchscreen Color portable operator terminal capable of connecting to one of the controllers on the communication bus and view parameters of the complete system. The terminal should be capable of viewing/changing parameters and trends, the specified parameters as per requirement etc. as required., 4\\" Touch screen
187Supplying Installation Testing Commissioning following type 3rd party Integration unit to provide the interface between Ethernet LAN and the 3rd party field control devices or any other devices which need to be integrated. These shall also provide supervisory capability of functions over the devices connected to it. The purpose of using these units should be limited to integrate the devices only. The Unit must have two onboard Ethernet port, minimum 2/3 on board RS485 ports. The Integration unit should have inbuilt 4GB memory for program storage. The Unit must communicate over TCP/IP with communication speed of 10/100MBPS. The Integration unit should be capable of handling multiple protocol simultaneously such as Bacnet, Modbus, SNMP restricted to single protocol. All integrators should be mandatorily BTL listed. The integration unit shall be housed in suitable size sheet steel enclosure made of 1.6mm thick CRCA sheet, lockable front door with glass, arrangement for cable entry and duly powder coated complete etc as required , upto 500 points.Fire Detection & Alarm System
188Supplying Installation Testing Commissioning of following Field Devices including connection etc. as required, water differential pressure (DP) switch for pump status
189Supplying Installation Testing Commissioning of following Field Devices including connection etc. as required, High/low level switch for tank level monitoring
190Supplying Installation Testing Commissioning of following Field Devices including connection etc. as required, water pressure sensor, accuracy +/-0.3% FSL
191Supplying Installation Testing Commissioning of following Field Devices including connection etc. as required, water level sensor
192Supplying Installation Testing Commissioning of following Field Devices including connection etc. as required, water flow switch
193Supplying Installation Testing Commissioning of following Field Devices including connection etc. as required, Outside Temp & Humidity Sensor with radiation shield. Measuring Range: Temp: -15 to 50 deg C & RH 0-100%, Accuracy: +/- 1 C +/-3%
194Supplying Installation Testing Commissioning of following Field Devices including connection etc. as required,Wall/Ceiling Mount CO Sensor
195Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range: -5° to +60°C, Bending Radius: < 4 X Cable Diameter at -5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.A One run of cable
196B Two run of cable
197Supply of XLPE insulated PVC innersheathed, copper conductor armoured cable 650V/1100V Grade as per IS 7098 of following size- 2 core 1.5 sqmm
198Supply of XLPE insulated PVC innersheathed, copper conductor armoured cable 650V/1100V Grade as per IS 7098 of following size- 4 core 1.5 sqmm
199Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 8X1.5 sq. mm.
200Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sqmm
201Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
202Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
203Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
204Supplying and fixing of 25 mm size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
205Section-6: HVAC
206Supplying, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation to IS: 655 and approved drawings and specifications of following sheet thickness complete as required.24 Gauge (0.63 mm thckness)
207Supplying, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation to IS: 655 and approved drawings and specifications of following sheet thickness complete as required.22 Gauge (0.8 mm thckness)
208Supplying, Fixing, installation, testing and commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. in confirmation to SMACNA/IS and as per specifications complete etc. as required 200 mm dia.
209Supplying and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminium sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound in confirmation to SMACNA/IS and as per specifications complete etc. as required.
210: Supplying, Fixing, installation, testing commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required
211Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc. as required
212Supplying, Fixing, installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required
213Supplying, Fixing, installation, testing and commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required
214Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted Gl volume control damper with enthalpy sensor and necessary control wire for integration within AHU room complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required. Damper
215Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted Gl volume control damper with enthalpy sensor and necessary control wire for integration within AHU room complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required. Actuator
216Section-7: Boom Barrier
217Supply, Installation, Testing and Commissioning of Premium Quality Swing type Barriegate/Boom Barrier complete in all respects (Civil/Electrical), having electromechanical drive unit with 100% duty cycle, boom of rectangular/oval/hexagonal shape made up of aluminium, Telescopic Arm Length 3 to 6 meter, Opening And Closing Time (3-6 Sec), Noiseless operation with auto Cooling system, Motor working time- 6 million times, operated by Radio Receiver with 1 remote control & Pushbutton, Colours options. available Yellow & Grey, Motor motion Control -Limit Switch & balanced Double spring system, should have Left/Right version interchangeable onsite, not to be one side fixed, housed in Steel Housing box, Working Voltage/frequency 220+-10% V, 50/60 Hz +-5% Hz AC/12V DC/24V DC, The boom barrier should have IP-54/IP-55 & weight of barrier 40-50 kg with Reflecting LED & light Tapes in Length, Rated Power/Torque/frequency: 100-150W, Torque 40-100 Nm, 50/60Hz, manual operation in case of power failure, including Civil foundation works (PCC)(foundation of minimum size 450mmLx450mm Wx3500(100 mm above ground level) (NS using M15 grade concrete)), The name of the MP/MLA/Councilor etc is to be written with their constituency with enamel paint of suitable size, CE/UL/BIS Certified including following accessories: a) PC Safety Anti accident Device (IR Sensors), b) Dual Channel Loop Control Detector including Induction Coil for Auto close operation, c) 3 Way Opening switch controller (Push Button), d) 2 Way traffic light 8\\" dia in Polycarbonate housing with minimum 2500mm mounting MS pole. (Excluding 3 core X 1.5 sqmm cable)
218Section-8: LIFT
219Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required:-10 passenger (680 Kg) (i) Speed-1 MPS,(ii) Floors-4 (-3,-2,-1,G),(iii) Travel-11.6 Meters (approx.),(iv) Stops & opening- 4 stops and 4 openings,(v) Controller: A.C. variable voltage & variable frequency(vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required.,(vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/without attendant,(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system(ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting.,(x) The car flooring should be smooth and antiskid as approved by engineer-in-charge.,(xi) Type of doors(a) Car: Power operated, centre / side opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish).(b) Landing doors: stainless steel scratch proof(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car.(xiii) Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.(xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder.(xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency.(xvi) An appropriate technological support be provided (Through emergency messaging services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness.(xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided
220PART-B: COMC
221Mobility / Internet Connectivity Charges. (To be reimbursed on Actuals)
222Providing of following Labour for day to day operation and maintenance of fire fighting equipments in Municipal Car parking i/c required T&P etc. on daily basis on all the days in a year (required maintenance material will be provided by Contractor) as required as per terms & condition of the Tender/contract complete as required. (a) One operator- Skilled. ( in three shift of 08 hours each day for one year.)
223Providing following Labour for day to day maintenance of Electrical Installation in Municipal Car parking i/c required T&P etc. on daily basis on all the days in a year (required maintenance material will be provided by Contractor) as required as per terms & condition of the Tender complete as required. (a) One Wireman- Skilled. (in three shift of 08 hours each day for one year.)
224Comprehensive Annual Maintenance of DG Sets (02 nos. of 125 KVA & 02 nos of 25KVA), Substation (630 Amps VCB Panel), HT Panel, Transformer (160KVA), Main LT Panel(630 amps) & other Electrical Panels, Fire Fighting system I/c main electric Hydrant Pumps (2850 lpm), Diesel Engine Pump(2850 LPM) and 180 LPM Jockey Pumps and pressurization pump, Fire Alarm system(10 Loop) & PA system, Gas flooding system, Fire Extinguishers, Electrical works, CCTV system, Ventilation System and Boom Barriers, EPBAX system, BMS, Boom barrier and 10 passenger lift complete with other associated Systems complete with all accessories (as attached in inventory) of systems l/c carrying out preventive/periodic maintenance servicing and attending all minor/major breakdown and faults along with repairs and replacement of defective parts of above systems as required. (CMC are valid after defect liability perA iod)For Ist Year
225For 2nd Year
226For 3rd Year
227For 4th Year
228For 5th Year
229Repair of MCD Multi level Underground Car Parking in Model Town-II in Ward No.68/KPZ Model Town.
230Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
231Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
232Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
233Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.
234Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
235Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand)
23612 mm cement plaster of mix :1:4 (1 cement: 4 fine sand)
237Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
238Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
239Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
240Distempering with 1st quality acrylic distemper (ready mixed ) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour:New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
241Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
242Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
243Painting with synthetic enamel paint of apprved brand and manufacture to give an even shade:Two or more coats on new work
244Welding by gas or electric plant including transportation of plant at site etc. complete.
245Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
246Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge.
247Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size) derived from natural sources.
2481:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources: 10 graded stone aggregate 40 mm nominal size) derived from natural sources.
249Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
250Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in- charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
251Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
252Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
253Applying priming coat:With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood
254Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : (Copper oxidised as per IS 1378)300x16 mm
255Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : (Copper oxidised as per IS 1378)250x10 mm
256Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : (Copper oxidised as per IS 1378)125 mm
257Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
258Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.NOTE: Item no 8.31 is brought from Sub Head 11 i.e. Flooring, Item No 11.36
259Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm
260Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
261Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
262Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter
263For pipes 250 to 300 mm diameter
264Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm witha pair of 15 mm C.P. brass pillar taps
265Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
266Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
267Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.75 mm diameter
268Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler75 mm
269Bend 87.5°75 mm bend
270Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe32 mm dia
271Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
272Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White
273Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size) derived from natural sources
274Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
275Carriage of material by mechanical transport including loading, unloading and stacking: 22 km leadLime, moorum, building rubbish 22 km lead
276Manufacturing, supplying and fixing retro reflective sign boards made which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing, specification and direction of Engineer-in-charge.Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm
277Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.
278Providing and fixing post delineators made of ABS round body fitted with 2 nos 100 mm dia high reflective reflectors and mounted on MS pipe of 65 mm dia duly powder coated anti-rust and anti theft steel to be installed as per direction of Engineer-in-charge.
279Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
280Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
281Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns
282Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size) derived from natural sources.
283Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57680919
AUTHORITY Local Bodies
TENDER VALUE 4.41 Crore
LAST DATE 08-10-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Repair And Maintenance Of All Electrical, Mechanical And Civil Installations Along With Comprehensive Operation, Maintenance And Upkeep Of All Electrical, Mechanical And Allied System/Installations For A Period Of Five Years In The Multi-Level Underground (Mlug) Car Parking At Model Town Under Keshav Puram Zone.
Basic Detail
Tender No TC/ENGG./EEE/KPZ/2026-27/21.1
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 24 Sep 2026
Submission Date 08 Oct 2026
Open Date 08 Oct 2026
Finance
Tender Value 4.41 Crore
Tender Fee 1770
EMD 8.83 Lakhs
Exemption Not Available
Document List
0bd05955-c433-4511-9d75-3c816e81c09b.html
BOQ_340529.xls
EligibilityCriteriatendercondition.pdf
MCD_GCC_2026Latestcirculars.pdf
Tenderconditionforcivilwork.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Oct 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

0bd05955-c433-4511-9d75-3c816e81c09b.html

xls

BOQ_340529.xls

pdf

EligibilityCriteriatendercondition.pdf

pdf

MCD_GCC_2026Latestcirculars.pdf

pdf

Tenderconditionforcivilwork.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders