Housing Urban and Rular Development Government Departments Closing in 6 days TDR #57680058

Tender For Supply Installation Testing and Commissioning of Air Conditioning System With Allied Electrical Work At Doctor Room Of The Ground Floor Of Woodburn Block And Surgical Store At Ground Floor Main Building In Ipgme&R -Sskm Hospital,Kolkata-El

Issued by Government Departments · Kolkata, West Bengal
Tender Value
5.90 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
6 days left
EMD
11800
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Air Conditioning System With Allied Electrical Work At Doctor Room Of The Ground Floor Of Woodburn Block And Surgical Store At Ground Floor Main Building In Ipgme&R -Sskm Hospital,Kolkata-Electrical Work

BOQ

Name of Work:- SITC of Air conditioning system with allied electrical work at Doctor room of the ground floor of Woodburn Block and surgical store at ground floor Main building in IPGME&R -SSKM Hospital,Kolkata-Electrical Work
Sl. No. Item Description
1Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original with Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating [ OGeneral / Mitsubishi Heavy / Mitsubishi Electric]
2Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazingincluding accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required (Rajco / Ryoku / Mandev)
3a) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
4b) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
5S& L of 4 Core 2.5sq. mm.FRLS copper control Cable (As Control Cable from ODU to IDU ) (Make : Havells / Gloster / Polycab).
6SITC of Drain piping with 25 MM PVC (Sch-40) pipes with fittings duly insulated with 9MM thick Nitrile rubber section, Vapour barrier with necessary quantities of supports, flanges, bends, elbows, fittings, nut-bolts, gaskets etc (Make:Supreme / Oriplast / Approved Make)
7Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.
8100 mm width X 50 mm depth X 1.6 mm thickness
9Supply, design, fabrication, installation of MS structural work for supports as per site requirement (As per direction of E.I.C)
10Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/HFFR PVC insulated copper conductor single core cable (Make:Havells / Polycab / Gloster) in surface/ recessed medium class PVC conduit (Precision/Polycab, MMS/HMS type), with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. class-C.
11Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLSH/HFFR PVC insulated copper conductor, single core cable (Make:Havells / Polycab / Gloster) in surface/ recessed medium class PVC conduit (Precision/Polycab, MMS/HMS type) as required.
122 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.
132 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
142 X 4 sq. mm + 1 X 4 sq. mm earth wire
15Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Anchor) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
16Supply & Fixing 240 V, 25 A Modular starter (North-West / Crabtree / Legrand) on 2 module GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc
17Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. etc.(Make:North-West / Crabtree / Legrand)
18Supply & Fixing 20A plug top (Make: Anchor / North-west).
19Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(Make:Dowells)
202 X 4 sq. mm + 1 X 4 sq. mm
212 X 2.5 sq. mm + 1 X 2.5 sq. mm
22Supply & Fixing of of 230V, 50Hz, 400 mm sweep heavy duty full metal body cabin fan having wattage ≤ 90 Watt, RPM ≤ 1325, Air Displacement (In CFM) ≥ 3550 complete with all accessories. (Make - Orient/Crompton/ EPC/Cinni) (for wood burn)
23S & F 250V 25A Timer controller for AC machine in SS double door 2+10-way DB enclosure (Make:- L&T, encloser cat no DBSPN012DD) or equvalant) with S&F following electrical accessories & front door locking arrangement with all connection by finishing the ends of 2x4 & 1x2.5 copper wire dowells solderless socket by crimping method as to GS earthing attachment on wall incl necessary connections as per direction of EIC :- i) 10kA, C-Curve, 240V, 25A ,DPMCB (LT/Schnider/ABB Elegance) --- 1 Noii) 24 Hr programmable Digital/Analog Timer (LT make cat no 67DDT0) ---- 1 Noiii) 3 pole power contractor (LT make cat no MNX 22/230V) with 1 NO +1 NC additional contact block ---- 2 set iv) 2 Moduler AC motor stater (Make:- Legrand/Myrius) ---- 1 No. v) 2 Module plate with cover (Make :- Legrand/Myrius) -- 1 No vi) 20A Auto-Off-Bipass SPDT toggle switch (Approved/reputed make) ---- 1 No. vii) 10A SPST Moduler type switch (Make :- Legrand/Myrius) - 1 No.viii) Outgoing connector make ELMAX (Approved/reputed make) - 1 No(for wood burn)
24Supply and replacement of Sealed Lead Acid Battery (FR Type) for UPS, including disconnection and removal of the existing batteries placed in racks. The service includes connecting the new batteries with the existing connectors, with the replacement of sockets and screws if necessary, and the removal of the old batteries as directed by the EIC. (The cost is inclusive of carriage charges and the 'buy-back' cost of the old batteries.)
2512V,150Ah Sealed Lead Acid Battery (FR Type) (Make: Exide EP 150-12 / Amara Raja as approved by EIC)
26The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill.If any refurbished material is supplied and installed, penal action will be taken as per existing rules
27Defect Liability Period - 2 (Two) years
28Make & model of each and every material to be approved by EIC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57680058
AUTHORITY Government Departments
TENDER VALUE 5.90 Lakhs
LAST DATE 05-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Supply Installation Testing and Commissioning of Air Conditioning System With Allied Electrical Work At Doctor Room Of The Ground Floor Of Woodburn Block And Surgical Store At Ground Floor Main Building In Ipgme&R -Sskm Hospital,Kolkata-Electrical Work
Basic Detail
Tender No WBPWD/EE-I/KSHED/T45/26-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 24 Sep 2026
Submission Date 05 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value 5.90 Lakhs
Tender Fee Ref. Documents
EMD 11800
Exemption Not Available
Document List
b7489736-d41f-4536-9402-cc71d1774238.html
BOQ_5163323.xls
TenderForm.pdf
Tendernotice_1 (41).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

b7489736-d41f-4536-9402-cc71d1774238.html

xls

BOQ_5163323.xls

pdf

TenderForm.pdf

pdf

Tendernotice_1 (41).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders