Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #57677535

Tender For Providing Of Certain Infrastructure At Lgj Mil Stn

Issued by Statutory Bodies & Commissions/Committees · bathinda, Punjab
Tender Value
44.83 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
10 days left
EMD
89660
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
bathinda → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Providing Of Certain Infrastructure At Lgj Mil Stn

BOQ

Name of Work:- PROVN OF CERTAIN INFRASTRUCTURE AT LGJ MIL STN
Sl. No. Item Description
1Surface dressing n.exc 15 cm deep in hard/dense soil etccomplete all as specified and directed by Engineer-in-Charge.
2Demolition concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
3Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
4All as per item No 3.00 above but exc 1.5 mtr and n.exc 3.0 mtr complete all as specified and directed.
5M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation, filling & mass concrete complete all as specified and directed.
6M&L for Formwork to sides of concrete foundations, footings , bases of concrete foundations, bases of columns, raft and raft beams, sides and soffits (if any) for rough finished surfaces complete all as specified and directed.
7M&L for formwork to sides of pillars, columns etc; rough finish surface of concrete square, rectangular or polygonal complete all as specified and as directed by Engineer-in-Charge.
8M&L for formwork to sides and soffits of floor or roof beams, beam hunchings, girders, bressummers, lintels, cantilevers, etc. also splays between floors and beams, etc. rough finish surface of concrete flat complete all as specified and directed.
9M&L for formwork to chajjas, troughts and similar items including edges rough finish surface of concrete flat complete all as specified and as directed by Engineer-in-Charge.
10M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200 mm thick (horizontal or sloping) rough finish surface of concrete flat complete all as specified and as directed by Engineer-in-Charge.
11M&L for fromwork to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n.exc 20 cm wide, rough finished surfaces of concrete complete all as specified and as directed by Engineer-in-Charge.
12M&L for RCC M-25 (Design Mix) using 20mm graded stone aggregrate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, pillers etc.complete all as specified and directed.Note : Reinforcement shall be measured and paid seperately.
13M&L for RCC M25 (Design Mix) using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed.Note : Reinforcement shall be measured and paid seperately.
14M&L for RCC M-25 (design mix) using 20mm graded stone aggregrate in Chajjas; complete all as specified and as directed by Engineer-in-Charge.Note : Reinforcement shall be measured and paid seperately.
15M&L for RCC M-25 (Design Mix) using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.Note : Reinforcement shall be measured and paid seperately.
16M&L for RCC M-25 (Design Mix) using 20mm graded stone aggregate as in slabs supported on wallls , beams and columns in floors , roofs , landings , balconies, canopies, deck slab and in shelves and the like complete all as specified and directed.Note : Reinforcement shall be measured and paid seperately.
17S&F for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
18All as per item No 17 above here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
19M&L for brickwork with fly ash bricks, old size bricks, straight or curved on plan exc. 6 m mean radius built in cm 1:6 complete all as specified and directed.
20Returning, filling in, including spreading levelling including watering & well ramming in layers n. exc 25 cm all complete as specified in soil complete all as specified and directed.
21Removing excavated materials n.exc 50 m and depositing where directed at leveln.exc. 1.50 m above the starting point complete all as specified and directed.
22M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
23M&L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc.15cm thick,watered and rammed to a true surface in Broken stone or boulders (15cm compacted thickness) complete all as specified and directed.
24M&L for 75mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub-base complete all as specified and directed.
25M&L for damp proof course 40 mm thick in Cment concrete 1:2:4 type B-0 to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.
26M&L for 75 mm thick PCC, (1:3:6), type C-1, using 20 mm graded crushed stone aggregate as in plinth protection finished even and smooth with using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and as directed by Engineer-in-Charge.
27M&L for rendering 15 mm thick on other than fare faces of brick work or concrete surfaces in cement mortar (1:6) including finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
28M&L for rendering 15 mm thick on outer faces of brick work or concrete surfaces in cement mortar 1 :4 including finished even and smooth complete all as specified and directed by Engineer-in-Charge.
29M&L for rendering 5 mm thick on concrete surface in ceiling surfaces in cement mortar 1:3 complete all as specified and directed by Engineer-in-Charge.
30M&L for two coats of acrylic distemper on new plastered surfaces of walls paint over 1.5 to 2.5 mm thick wall care putty over a coat of primer including preparation of surfaces complete all as specified and as directed by Engineer-in-Charge.
31M&L for applying two coat of weather proof exterior emulsion paint ( shade as approved by GE) with highlighter of any approved shade, @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/ cantilevers/balcony etc surfaces over wall care putty (thickness very from 1.5 to 2.5 mm as required for desirable smoothness and levelling of surfaces in two or more layers) on newly plastered surfaces of wall including preparation of surface complete all as specified and directed by Engr-in-charge
32M&L for 3 coats of white wash on newly plastered surfaces incl preparation etc. complete on ceiling complete all as specified and directed by Engr-in-charge
33Material and labour for applying 10mm thick rendering /screed in cement mortar (1:4) including mixing of liquid WPC in mortar @ as per manufacturer instruction per bag of cement of 50kg and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. Note :- WPC shall be measured & paid separately as Supply only under relevant item.
34OVERLAY- PU BASED ELASTOMERIC LIQUIED MEMBRANE SYSTEM FOR EXPOSED ROOF : Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index not less than 106 as per (ASTM E1980-19)/tear strength ~20 N/mm (Free film, 14 days, +30 degree C) (ASTM D624) and tensile strength >= 2 N/mm2 (ASTM D4541), elongation 350 to 400% as per ASTM D412 and crack bridging ability upto 2mm.(a) After proper surface preparation, Apply one coat of Primer for PU coating as per manufacturers specification.(b) Apply 1st coat of ShaliUrethane® BTD (white) @ 650 gm / m²(minimum) or equivalent by brush / roller while prime surface is tacky, Spread waterproofing reinforced Glass Fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry. (c ) Apply 2nd & 3rd coat of ShaliUrethane® BTD (white) @ 650 gm / m² (minimum) or equivalent by brush/roller. Make : Fosroc/Sika/Choksey/Bostik/STP/ Asian Paints/Berger PaintsNote : (i) The Minimum dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat. (ii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE.(iii) The manufacturer/authorised applicator shall give a warranty for the performance & durability for 10 years.
35Supply only liquid water proofing compound all as specified and directed by Engr-in-Charge.
36M&L for providing double charge vitrified coloured tiles (approved shade), area of each tile exceeding 0.36 Sqm but not exceeding 1.44 Sqm, having thickness more than 8mm, premium quality having water absorption less than 0.08%, straight edge, stain free, glossy finish, square marbonite, laid as in floors/skirting etc., set and jointed including using type-2 adhesive (Medium Thick Bed Fixing) confirming to IS-15477:2019, fixed the tile using spacer 5mm or as per manufacturer’s instruction and joint filled with epoxy grout matching with the colour of tiles including necessary cutting as per site requirement, complete all as specified and as directed.
37All as per Item no 36 here in before, on vertical surfaces such as skirtings ,set & jointed in neat and pointed in epoxy grout to match the floor tiles, over & including 10 mm thick screed in cement mortar (1:4) complete all as specified & directed by Engr-in-charge.
38M&L for joint free Non- skid coloured ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. Set & jointed in neat cement slurry & jointed in coloured cement to match the colour of tiles over & including 15 mm thick screed bed in cm 1:4 and pointed in epoxy grout to match in floor complete all as specified & directed by Engr-in-charge.
39M & L for Ceramic wall tiles as per IS 15622: 2017 and IS 13712: 2019, group B III, glazed, unpolished, rectified, 300x600mm, minimum 8 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed.
40M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps jambs, pillers, window -cills cooking platforms and like in cement mortal (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, cutting and moulding edges complete all as specified and directed.
41M & L for Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24 mm X 38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross “T” of size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm centre to centre to form a grid of 1200 mm x 600 mm and secondary cross “T” of length 600 mm and size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 mm X 600 mm panel to form grids of 600 mm X 600 mm and wall angle of size 24 mm X 24 mm X 0.4 mm. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 mm X 37 mm X 25 mm X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 mm X 30 mm X 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications and as directed by Engineer-in-charge.
42M & L for 4 mm thick plain fibre cement flat sheets type B, any category as per IS 14862: 2000 (non-asbestos) building boards, cured in HPSC (high pressure steam curing ) process, highly chemical stabilised, design and texture as approved of Make Armstrong/Everest/ Ramco, fixed to timber/GI /Aluminium framework with screw in ceilings flat or sloping complete all as specified and as directed.
43M & L for Providing and fixing factory made uPVC white colour double shutter (one glazing and one gauzing) openable window area exc. 1.00 Sqm but not exceeding 2.00 sqm each made of extruded profiles with wall thickness of 2.3mm(+-0.2mm) with or without provisioning of opening for cooler. Window profile with hollow section with multi chamber. Frame (60mm x58mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket.1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, including supply and fixing following items :-(a) casement handle made of zinc alloyed (white powder coated)(b) Stainless steel But Hinges - 03 Nos Each shutter (c) transmission gear made of mild steel with multi point locking system. (d) 5mm thick toughenend glass and 0.36mm nominal dia of stainless steel guaging with selected quality glass/mesh complete all as specified & directed by Engineer-in-Charge.
44M & L for Providing and fixing factory made uPVC white colour openable ventilator window area not exc. 1.00 Sqm each made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket.1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, including supply and fixing following items :-(a) casement handle made of zinc alloyed (white powder coated)(b) Stainless steel But Hinges - 03 Nos Each shutter (c) transmission gear made of mild steel with multi point locking system. (d) 5mm thick toughenend frosted glass and 0.36mm nominal dia of stainless steel guaging with selected quality mesh complete all as specified & directed by Engineer-in-Charge.
45M&L for framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spiles; framed guard bars; barred iron doors; ladders; framed balusteres; walk ways, railings; framework of water tanks and similar work confirming to Fe. 290, Gde-E-165 with complete all as specified and as directed by Engineer-in-Charge.
46M&L for preparation of new steel surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
47S&F powder coated aluminium frame for doors, windows, ventiators with one or more rebates including jointing cleats for fixing with powder coating on aluminium sections, minimum thickness of powder coating shall be 50 micron as per the specification, complete all as specified & directed by Engr-in-charge.. Make of Al section : Jindal/Hindaco/Nalco
48S&F Powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/m (min thick 1.50 to 1.80 mm including necessary joining cleats, glazing clips, rubber neoprene packing, 150mm Alumn handle 2 Nos in each door, 100mm SS hinges (3 Nos), mortise lock (01 No), 150mm Alumn tower bolt (02) anodised aluminum snap beading screws etc.minimum thickness of powder coating shall be 50 micron as per the specification, complete all as specified & directed by Engr-in-charge..
49S&F 5 mm thick tinted glass glazing to aluminium door and the like in square exc. 0.50 sqm in each pane complete all as specified & directed by Engr-in-charge. Please Enable Macros to View BoQ information
50S&F 5 mm thick tinted glass glazing to aluminium door and the like in square exc. 0.50 sqm in each pane complete all as specified & directed by Engr-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57677535
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44.83 Lakhs
LAST DATE 14-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing Of Certain Infrastructure At Lgj Mil Stn
Basic Detail
Tender No CA NO CWE SGNR/TOKEN-40 OF 2026-27
Bidding Type Tender
Location
City bathinda
State Punjab
Key Dates
Publish Date 23 Sep 2026
Submission Date 14 Oct 2026
Open Date 15 Oct 2026
Finance
Tender Value 44.83 Lakhs
Tender Fee 500
EMD 89660
Exemption Available
Document List
BOQ_886482.xls
ee6417ce-1cb2-4801-8fcd-76fb08c9250b.html
Tendernotice_1.pdf
Tender_40.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Oct 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_886482.xls

html

ee6417ce-1cb2-4801-8fcd-76fb08c9250b.html

pdf

Tendernotice_1.pdf

pdf

Tender_40.pdf

Disclaimer