Tender For Provn Of Acs In Jcos & Sainik Mess At Nda Khadakwasla
Tender Value
32.76 Lakhs
Estimated cost
Bid Submission
20 Oct 2026
2 days left
EMD
66000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Provn Of Acs In Jcos & Sainik Mess At Nda Khadakwasla
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply and install Hi wall split type AC units indoor/outdoor complete with cordless remote control unit and with in built air ioniser invertor type compressor, 100% copper tubing of Indoor & Outdoor cooling & condenser unit respectively with CFC free gas for better indoor air quality with 5 star rating and EER 3.2 of capacity 2.0 TR single phase including cabling work, insulation between indoor unit to outdoor unit and provision of MS Brackets for resting of outdoor units (where reqd) or making resting platform of outdoor unit by brick works complete all as directed. Make : Carrier/Daikin/Hitachi/Blue Star. |
| 2 | Supply and install Hi wall split type AC units indoor/outdoor complete with cordless remote control unit and with in built air ioniser invertor type compressor, 100% copper tubing of Indoor & Outdoor cooling & condenser unit respectively with CFC free gas for better indoor air quality with 5 star rating and EER 3.2 of capacity 1.5 TR single phase including cabling work, insulation between indoor unit to outdoor unit and provision of MS Brackets for resting of outdoor units (where reqd) or making resting platform of outdoor unit by brick works complete all as directed. Make : Carrier/Daikin/Hitachi/Blue Star. |
| 3 | S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA Make one of the following : V-Guard/ Vinitec/Sen and Pandit/Microtek/AE/Voltas |
| 4 | M&L for sub main wiring 2 x 4.0 Sqmm for phase and neural, 1 x 4.0 Sqmm for earth wire PVC insulated (heavy duty) 1100 volts grade, FRLSH, with single core copper conductor in & including PVC casing caping of suitable size not less than 25mm (3 run of 4.0 Sqmm cable with PVC casing caping will be measured as one RM) all as specified and directed (from distribution board to metal clad switch socket point near AC).Make: Havells/ Anchor/ Polycab/ Finolex/ Gloster |
| 5 | S&F incl connecting sheet metal enclosure with two pin and earth plug and socket complete, with one single pole MCB 20 Amp.Make: Legrand/ BCH/ Standard/ Havells |
| 6 | M&L for PVC pipe 20 mm dia heavy duty with all fittings and fixing accesssories such as coupler, lock nut, saddle, pipe hook and laid on floor (for drain line) complete all specified and directed. |
| 7 | M&L for high thermal conductivity and corrosion resistance Copper Tube of size 1/4 inch (6mm) with insulation of nitrile rubber of 6mm thickness including all fittings and fixing accesssories used in extended length complete all as specified and directed. |
| 8 | M&L for high thermal conductivity and corrosion resistance Copper Tube of size 1/2 inch (13mm) with insulation of nitrile rubber of 6mm thickness including all fittings and fixing accesssories used in extended length complete all as specified and directed. |
| 9 | M&L for high thermal conductivity and corrosion resistance Copper Tube of size 5/8 inch (16mm) with insulation of nitrile rubber of 6mm thickness including all fittings and fixing accesssories used in extended length complete all as specified and directed. |
| 10 | M & L for making holes by core cutting machine on stone/concrete / brick walls.Dia of hole not exc.50mm and thickness of wall 50cm to 70cm for entry of suction and discharge pipes of AC and making good distarbed surfaces with cement morted and finally finished with plaster of paris and painted the distrubed surfaces with existing type of paint and tint complete all as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 13, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Oct 20, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysOct 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysOct 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender