Defence Statutory Bodies & Commissions/Committees Closing in 4 days TDR #57677358

Tender For Special Repair To Conversion Of Lt O/H Line Into Ug Cable With Connected Accessories At Lower Block And Uper Block Of 92 Bh At Bb Cantt, Srinagar.

Issued by Statutory Bodies & Commissions/Committees · srinagar, Jammu and Kashmir
Tender Value
42.71 Lakhs
Estimated cost
Bid Submission
07 Oct 2026
4 days left
EMD
85500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
srinagar → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Conversion Of Lt O/H Line Into Ug Cable With Connected Accessories At Lower Block And Uper Block Of 92 Bh At Bb Cantt, Srinagar.

BOQ

Name of Work:- SPECIAL REPAIR TO CONVERSION OF LT O/H LINE INTO UG CABLE WITH CONNECTED ACCESSORIES AT LOWER BLOCK AND UPER BLOCK OF 92 BH AT BB CANTT, SRINAGAR.
Sl. No. Item Description
1Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, pipes etc. and getting out all excavated material in any type of soil, complete all as specified and directed.
2Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and as directed.
3Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point, complete all as specified and directed.
4M&L for locally available river sand in trenches 15 cm below cable and 8cm above / around UG cable for cable protection, in duct under and above the cables including punning around cable, complete all as specified and directed.Note: - Punned thickness shall only be measured and paid.
5Supply and laying GI pipe 'light grade' 40 mm in trenches, under floors, roads, along poles for protection of cables with all necessary fittings and sealing ends, complete all as specified and directed.
6Supply and laying GI pipe 'light grade' 50 mm in trenches, under floors, roads, along poles for protection of cables with all necessary fittings and sealing ends, complete all as specified and directed.
7Supply and laying GI pipe 'light grade' 80 mm in trenches, under floors, roads, along poles for protection of cables with all necessary fittings and sealing ends, complete all as specified and directed.
8Supply and laying unreinforced PCC Cable protection cover, class LV, type-1 flat with size 250 x 150 x 40 mm laid flat width wise, complete all as specified and directed.
9Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 240 sq mm 3.5 core, complete all as specified and directed.
10Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 185 sq mm 3.5 core, complete all as specified and directed.
11Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 150 sq mm 3.5 core, complete all as specified and directed.
12Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 95 sq mm 3.5 core, complete all as specified and directed.
13Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 70 sq mm 3.5 core, complete all as specified and directed.
14Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 50 sq mm 3.5 core, complete all as specified and directed.
15Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 25 sq mm 4 core, complete all as specified and directed.
16Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 25 sq mm 2 core, complete all as specified and directed.
17Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 16 sq mm 2 core, complete all as specified and directed.
18Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 10 sq mm 2 core, complete all as specified and directed.
19Supply, laying and testing cable XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross- sectional area 6 sq mm 2 core, complete all as specified and directed.
20M & L for Copper busbar, weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick outdoor type with ingress protection of IP-54 grade having copper bus bar of rating 450 Amp capacity, 415 volt colour code with neutral including 250 Amp MCCB three phase and netural with encloser with cable gland as per incoming and outgoing cable sizes including indication lamp, angle iron leg and PCC foundation, complete all as specified and directed.
21M & L for Copper busbar, weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick outdoor typewith ingress protection of IP-54 grade having copper bus bar of rating 150 Amp capacity, 415 volt colour code with neutral including 100 Amp MCCB three phase and netural with encloser with cable gland as per incoming and outgoing cable sizes including indication lamp, Angle iron leg and PCC foundation, complete all as specified and directed.
22Material and labour for road cutting of minimum sizes 30cm x 30cm for laying cables etc and making good the disturbed surface to match existing surface using plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregate), complete all as specified and as directed.
23Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with 32x6mm size GI strip as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and directed.
24M&L for earthing work complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level and connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers of galvanised steel and to be protected by GI pipe 15 mm bore light grade & connected to earth test point/main switch board or main control board and also providing charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil all as shown in Electrical Plate No 3 of SSR part -I. and also making arrangment of 20 mm dia bore galvanised iron pipe (medium grade) for water and making funnel, wire mesh,and also including provision of concrete pit cover framing work in PCC (1:2:4) type B-1 using 20mm graded of stone aggregate with XPM (weight not less than 4 Kg/Sqm) and outer frame work of angle iron 25x25x6mm with top concrete pit cover and handle for lifting of cover, complete work all as specified and directed .
25Supply, installation, testing and commissioning of LT Panel board suitable for 415 Volts, 3 Phase 4 wire, 50 Hz AC supply system outdoor type floor mounted along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having copper bus bar of rating 1050 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The panel shall be front and rear both side openable and having inner & outer shells. The inner shell dully compartmented for each control gear, including powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1200mm x 1200mm x 450mm, mounted on angle iron stand made out of angle size 50 x 50 x 6mm grouted in PCC foundation in cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), suitable sizes of cable glands for incoming and outgoing cables sizes with the following switch gears/ accessories:-
26(a) MCCB 630 Amps 4 pole ,50 KA 415 Volts (Incomer ) -01 No(b) MCCB 400 Amps 4 pole ,35 KA 415 Volts (outgoing ) -01 No(c) MCCB 250 Amps 4 pole ,35 KA 415 Volts (outgoing ) -01 No(d) MCCB 200 Amps 4 pole ,35 KA 415 Volts (Outgoing) -01 No(e) Copper Bus bar of capacity 1050 Amps 3 phase and neutral -1 set.(f) Digital type voltmeer 0-500 volts.(g) Digital type Ammeter with CT of suitable ratio for reading upto 400 amps load-01 No(h) Indicating LED lamps R,Y& B -01 set(j) Suitable size of cable gland as per I/C and O/G cables.
27Supply, installation, testing and commissioning of LT Panel board suitable for 415 Volts, 3 Phase 4 wire, 50 Hz AC supply system outdoor type floor mounted along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having copper bus bar of rating 650 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The panel shall be front and rear both side openable and having inner & outer shells. The inner shell dully compartmented for each control gear, including powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1200mm x 1200mm x 450mm, mounted on angle iron stand made out of angle size 50 x 50 x 6mm grouted in PCC foundation in cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate suitable sizes of cable glands for incoming and outgoing cables sizes with the following switch gears/ accessories:-
28(a) MCCB 400 Amps 4 pole ,36 KA 415 Volts (Incomer ) -01 No(b) MCCB 250 Amps 4 pole ,36 KA 415 Volts (Outgoing) -02 No(c) MCCB 200 Amps 4 pole ,36 KA 415 Volts (Outgoing) -01 No(d) SPN 63 Amps, 25 KA 240 Volts (outgoing ) -02 Nos(e) Copper Bus bar of capacity 650 Amps 3phase and neutral -1 set.(f) Digital type voltmeer 0-500 volts.(g) Digital type Ammeter with CT of suitable ratio for reading upto 400 amps load-01 No(h) Indicating LED lamps R,Y& B -01 set(j) Suitable size of cable gland as per I/C and O/G cables.
29Supply, installation, testing and commissioning of LT Panel board suitable for 415 Volts, 3 Phase 4 wire, 50 Hz AC supply system outdoor type floor mounted along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having copper bus bar of rating 1050 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The panel shall be front and rear both side openable and having inner & outer shells. The inner shell dully compartmented for each control gear, including powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1200mm x 1200mm x 450mm, mounted on angle iron stand made out of angle size 50 x 50 x 6mm grouted in PCC foundation in cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate, suitable sizes of cable glands for incoming and outgoing cables sizes with the following switch gears/ accessories
30(a) MCCB 630 Amps 4 pole ,36 KA 415 Volts (Incomer ) -01 No(b) MCCB 400 Amps 4 pole ,36 KA 415 Volts (Outgoing) -01 No(c) MCCB 250 Amps 4 pole ,36 KA 415 Volts (Outgoing) -0 2 Nos(d) SPN 63 Amps, 25 KA 240 Volts (outgoing ) -02 Nos(e) copper Bus bar of capacity 1050 Amps 3phase and neutral -1 set.(f) Digital type voltmeer 0-500 volts.(g) Digital type Ammeter with CT of suitable ratio for reading upto 400 amps load-01 No(h) Suitable size of cable gland as per I/C and O/G cables.
31Supply, installation, testing and commissioning in replacement of LT Panel board suitable for 415 Volts, 3 Phase 4 wire, 50 Hz AC supply system outdoor type floor mounted along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having copper bus bar of rating 450 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The panel shall be front and rear both side openable and having inner & outer shells. The inner shell dully compartmented for each control gear, including powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1200mm x 1200mm x 450mm, mounted on angle iron stand made out of angle size 50 x 50 x 6mm grouted in PCC foundation in cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), suitable sizes of cable glands for incoming and outgoing cables sizes with the following switch gears/ accessories:-
32(a) MCCB 250 Amps 4 pole ,36 KA 415 Volts (Incomer ) -01 No(b) MCCB 200 Amps 4 pole ,36 KA 415 Volts (Outgoing) -03 Nos(c) Copper Bus bar of capacity 450 Amps 3 phase and neutral -1 set.(d) Digital type voltmeer 0-500 volts.(e) Digital type Ammeter with CT of suitable ratio for reading upto 400 amps load-01 No(f) Suitable size of cable gland as per I/C and O/G cables.
33Supply and Erecting in vertical position steel tubular swaged pole type 410 SP-31 (9 metre long) with 300mmx300mm x6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5M from ground level/coping and making 30cm black and white strips with two coats of super enamelled paint up to 1.5M from ground level/coping, complete all as specified and directed.Note:- Earthwork and concrete shall be measured and paid saparatly under respective items.
34M&L for painting of existing steel tubular pole upto 09 mtrs length including clamp and bracket with two coats of aluminium paint after preparation of old painted surface and providing 03 no. alternate strip of 30 cm wide with black and white super quality enamel paint above embeded level and writing pole no. with 02 inch wide letter, complete all as specified and directed.
35Supply and fixing of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including taking down & thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
36Supply & fixing Thermo plastic street light sintex box of size 280 X 170 X 120 mm fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box, complete all as specified and directed.
37Supply and fixing, cable route marker for LT cable duly engraved (LT 1.1 KV cable) on 150 mm dia MS round plate 10mm thik duly painted with yellow colour paint and fix on MS angle of 40mmx40mmx5mm with nuts and bolts and embedded in PCC (1:2:4) concrete block of size 230mmx 230mmx 150mm, including necessary excavation & eathed work, complete as specified and directed.
38Supplying, fixing, jointing and testing LT Service cable PVC insulated, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross sectional area 10 Sqmm x 2 Core, with electric connection lugs, laid in trenches/under floor or fixed naked with walls / on poles/ in ducts / in GI pipes etc. and including taking down old service cable, complete all as specified and directed.
39Supply and laying HDPE DWC Pipe outer dia 90/76 mm. for protection and covering the XLPE cable, complete all as specified and directed.
40Supplying and fixing of flexible type round PVC bedded with PVC insulated and sheathed with multi FRLS cable of 1100 volt grade with multistranded copper conductor wire of size 1.5 Sq.mm 3 core type (Nominal area) ISI Marked, complete all as specified and as directed.
41Supply and fixing of rigid non metalic PVC conduit of size 15/20 mm bore heavy duty with all fitting laid in trenches/ wall including providing clamping arrangment for holding of pipe on wall in proper size of clamps, nut bolt ,and washer etc., complete all as specified.and directed
42Dismaintling old PCC/ tubular Pole from site with complete finishing existing surface, complete all as specified and directed
43Dismantling existing cross arms of any capacity/size of MS channel or angle sections etc., complete all as specified and directed.
44Dismantling existing insulators of any type and any size from pole including pins, complete all as specified and directed.
45Dismantling stay assembly of any type embedded in cement concrete etc., complete all as specified and directed.
46Dismantling and taking down the existing LT over head ACSR or AAC conductor of any description, complete all as specified and directed.
47Notes :-An amount of Rs 68,350.00.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57677358
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42.71 Lakhs
LAST DATE 07-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Conversion Of Lt O/H Line Into Ug Cable With Connected Accessories At Lower Block And Uper Block Of 92 Bh At Bb Cantt, Srinagar.
Basic Detail
Tender No 864/WS-75(T)/2026-27
Bidding Type Tender
Location
City srinagar
State Jammu and Kashmir
Key Dates
Publish Date 23 Sep 2026
Submission Date 07 Oct 2026
Open Date 13 Oct 2026
Finance
Tender Value 42.71 Lakhs
Tender Fee 500
EMD 85500
Exemption Available
Document List
766bb37b-ea18-49b9-9bdb-5b8edb1ab8ac.html
BOQ_886419.xls
Tender75_merged.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

766bb37b-ea18-49b9-9bdb-5b8edb1ab8ac.html

xls

BOQ_886419.xls

pdf

Tender75_merged.pdf

pdf

Tendernotice_1.pdf