Tender For Proposed Special Repair Works For The Existing District Environmental Engineer Office Building Tamil Nadu Pollution Control Board At Arumbakkam In Chennai City
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Oct 2026
2 days left
EMD
65700
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Proposed Special Repair Works For The Existing District Environmental Engineer Office Building Tamil Nadu Pollution Control Board At Arumbakkam In Chennai City
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: The Superintending Engineer / Chennai Circle Name of Work: Proposed Special repair works for the existing district Environmental Engineer office building Tamil Nadu Pollution Control Board at Arumbakkam in Chennai city Contract No: SE/CC/DB/ 3106 /2026 Bidder Name : BOOKLET - 4TENDER CODING SHEET ( BOQ) CONTAINS : 19 Pages( RATES TO BE FILLED UP BY THE TENDERER IN THIS CODING SHEET )SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make Qty Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against 1 No Item Quoted Currency in INR / Other Currency Rate exclusive of GST in Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Rate exclusive of GST in words AMOUNT Rs. P. AMOUNT Rs. P. TOTAL AMOUNT In Words |
| 2 | DM-PT-WE-INDismantling the damaged pressed tiles in cement mortar and weathering course in lime concrete without affecting the adjacent structures in all floor |
| 3 | CN-TEC-WC-NS) Weathering Course with concrete broken brick jelly 20mm gauge in pure burnt lime stone slaked and screened (No Sand) |
| 4 | TL-RO-PT-CM 1:3) Finishing top of roof with one course of Pressed Tiles of approved superior quality of size 23cmx 23cmx20mm thick laid over weathering course in CM 1:3 |
| 5 | PA-CE-WW-SL 2C) White washing two coats using clean shell lime slaked |
| 6 | DW-D-W-FRemoving the damaged broken door/window /ventilators |
| 7 | JN-UPVC W-UPVC-OP W) Supplying and fixing in position of UPVC window of casement type( open) for all sizes |
| 8 | JN-V-UPVC-LV) Supplying and fixing in position of UPVC Ventilator louvered ventilator type for all sizes |
| 9 | MW-MS-GR) M.s Grills |
| 10 | PA-Ex-IW-2C EP) Painting - New \\"iron work\\" |
| 11 | PA-IN-OWP-2C EP) Painting the old wood work with two coats of approved Ist class synthetic enamel paint including thorough scrapping |
| 12 | PA-IN-MP-OW) Providing wooden Melamine polish for old wood work |
| 13 | PA-IN-PEP-OW 2CPainting the old walls with two coats of 1st class ready mixed emulsion paint of best approved quality colour and shade including thorough scrapping the old plastered surface |
| 14 | PA-Ex-EEP-OW 2C) Painting old walls two coats with Exterior emulsion paint of first class quality paint of approved colour and shade for outer wall and other similar works including through scrapping |
| 15 | FW-SS-SCA-F&RProviding, erecting and removing the safe pipe scaffolding and/ or H frame |
| 16 | DM-R-FCRemoving the Existing False Ceiling with out affecting the adjacent Structures etc., |
| 17 | IN-FC-BFC-TkSupplying, fabricating, erecting and fixing Calcium Silicate Board False Ceiling using Perforated Sheets (10mm thick) upto a ceiling height of 4.5m from floor levelIN-FC-Ca2Si-10mm Pere) Calcium Silicate Board 10mm thick (Perforated sheet) false ceiling |
| 18 | IN-PW-MOD-HHMODULAR LINEAR PARTITION (Half Height ) Main & Return Frame: 30/50/60 mm thick panelHalf Height Partition - 1.20m Height (900mm Ht Panels + 300mm Ht Glass) |
| 19 | IN-WP-WPC-18mmProviding wall panelling using Prelaminated WPC (Wood Polymer composite) board sheet with the thickness of 18mm (+/- 1mm) & minimum of 0.70 Density |
| 20 | EW-AS-Dr-ER) Earth work excavation for Open foundation for drains (Excluding Refilling) (Drain having bed width upto 1.25 metre).EW-AS-Dr-ER-2m) a) 0 to 2m depth |
| 21 | CN-FB-PCC-1:5:10) Plain cement concrete 1:5:10 for Foundation & Basement |
| 22 | BW-PW 114mm-CB-CM 1:4) Brick partition wall in Cement Mortar 1:4 114mm thick for super structure in the following floors using chamber burnt bricks of size 9”x4¼”x3” (23x11.4x7.5cm)BW-PW 114mm - FB-CB-CM 1:4a) In Foundation and Basement |
| 23 | PL-OU-CM 1:5-12mm) Plastering in C.M. 1:5, 12 mm thick |
| 24 | PL-IN-CM 1:4-12mm) Plastering in C.M. 1:4, 12 mm thick |
| 25 | CN-FB-PCC-1:2:4) Plain cement concrete 1:2:4 using 20mm gauge |
| 26 | PL-FL-CM 1:4-20mm) Plastering the top of flooring in CM 1:4, 20 mm thick |
| 27 | DM-FL-TI-CMDismantling the damaged floor finish and dadooing walls in cement mortar with Mosaic tilex / Glazed tiles / Cuddapah slabs without affecting the adjacent structures |
| 28 | TL-WL-GZT-CM 1:2) Supplying and fixing of Colour glazed tiles using Grout (Tile Joint Filler), C.M 1:2, 10mm thick |
| 29 | TL-FL-CT-CM 1:3) Supplying and fixing of colour Ceramic Tiles Anti skid using Grout (Tile Joint Filler). |
| 30 | PL-CL-CM 1:3-10mm thick) Special ceiling plastering in cement mortar 1:3, 10 mm thick |
| 31 | SA-IN-EWC-C) Supplying and fixing EWC superior variety (Colour) 500mm with PVC SWR grade 'P' or 'S' trap |
| 32 | WS-EX-ASTM-PVC) Supplying, laying, fixing and jointing the following PVC pipes as per ASTM D - 1785 of schedule (40/60/80)WS-EX-ASTM-32 PVC a) 32mm dia ASTM D schedule 40 threaded PVC pipe with necessary PVC/UPVC specials |
| 33 | WS-EX-ASTM-25 PVC b) 25mm dia ASTM D schedule 40 threaded PVC pipe with necessary PVC/UPVC specials |
| 34 | WS-IN-ASTM-20 PVC CONCLD c) 20mm dia ASTM D schedule 40 threaded PVC pipe with necessary PVC/UPVC specials |
| 35 | SA-Ex-SWR P-DiaSupplying and fixing the following dia PVC (SWR) pipe SA-Ex-SWR P-75a) 75mm dia PVC SWR pipe including all required PVC specials etc., all complete., |
| 36 | SA-Ex-SWR P-110b) 110mm dia PVC SWR pipe including all required PVC specials etc., all complete., |
| 37 | SA-Ex-SWR P-160c) 160mm dia PVC SWR pipe including all required PVC specials etc., all complete., |
| 38 | SA-Ex-SWR P-50) Supplying, laying and concealing the 50mm dia PVC (SWR) pipe with ISI mark confirming to IS 13952:1992- type 'B' for waste water line |
| 39 | SA-IN-WB-P) Supplying and fixing of porcelin Wash hand basin (white without pedastal), superior variety of size 550x400mm with all accessories |
| 40 | SA-IN-WB-OSe).Oval Shape wash hand basin |
| 41 | SA-IN-Spl.-Fit) Supplying and fixing of best approved quality of following CP water supply/Sanitary fittings confirming to ISI specification SA-IN-CP-2WBCa) CP Two Way Bib Cock with Health Faucet |
| 42 | WS-IN-HCP-LBT) Supplying and fixing of half turn C.P Long body Tap of 15mm dia of best quality |
| 43 | WS-IN-HCP-SBT) Supplying and fixing of 15mm dia half turn C.P Tap (Short body Tap) of Best quality |
| 44 | SA-IN-FBU-PSupplying and fixing of approved brand Porcelain Flat Back urinal superior variety |
| 45 | SA-IN-NT-PVC) Supplying and fixing of PVC Nahani Trap not less than 75mm 4 way / 2 way (Superior variety) |
| 46 | SA-Ex-SFRC-S) Supply and delivery at site and fixing of SFRC manhole cover with frame with locking arrangementSA-Ex-SFRC-600 x 600) b) 600mm x 600mm |
| 47 | DM-R-PBLaying charges for removing the existing paver block |
| 48 | FL-FB-SDsupplying and filling in foundation and basement with Stone dust in layers of 150 mm thickness well watered, rammed and consolidated complying with relevant standard specifications |
| 49 | RW-PB-D-RMHSupplying and fixing of Rubber Moulded Hydraulic Pressed Paver Bloc of approved quality and make of building front and back sideRW-PB-D-RMH - 83a) 83mm thick |
| 50 | DW-DMB-PCCDismantling the damaged Plain cement concrete flooring without affecting the adjacent structures |
| 51 | BW-FB&S-CB-CM 1:5) Brick work in CM 1:5 using chamber burnt bricks of size 9”x4½”x3” (23x11.4x7.5 cm)BW-FB-CB-CM 1:5 ) a) Foundation and basement |
| 52 | CN-F&S-RCC-M30) Providing and laying in position, Standardised Concrete Mix M-30 GradeCN-FB-RCC-M30) a. In Foundation and basement |
| 53 | RE-CRS-Fe550-CO) Supplying, fabricating and placing in position of Ribbed Tor Steels for reniforcement Fe550D (Corrosion resistant reinforcement) of all diameters for reinforcements for all floors |
| 54 | EL-IN-OCEP-OLP) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with 5 amps flush type switch [Open Wiring]EL-IN-OEP-WCRa) Light point With Ceiling Rose |
| 55 | EL-IN-OCEP-FP) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point (Open wiring) |
| 56 | EL-IN-OCEP-SLP) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable ISI mark for STAIRCASE LIGHT POINT (Open wiring) |
| 57 | EL-IN-OCEP-CP) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark conforming to IS: 694/1990, 1.1K.v. grade cable for 5 amps. 5 pin plug socket point at convenient places (Open wiring) |
| 58 | EL-IN-CEP-SBI) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself. |
| 59 | EL-IN-EP-PS) Supplying and fixing of 15 Amps 3 pin flush type plug using ( PVC Box , Fire Retarded Box) |
| 60 | EL-IN-OWR-2x1.5m2) Run off the 2 wires of 1.5 sqmm copper PVC insulated single core cable [ Open Wiring ] |
| 61 | EL-IN-OWR-2x2.5m2) Run of main with 2 wires of 2.5 sq.mm. PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark grade cable in fully concealed [Open wiring] |
| 62 | EL-IN-OWR-2x4m2) Run off the 2 wires of 4sqmm copper PVC insulated single core cable [Open Wiring] |
| 63 | EL-IN-EF-AC Plug - 20A) Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) |
| 64 | EL-IN-EF) Supply and delivery of following Electric Ceiling fan with ISI markEL-IN-EF-48\\"F) a) 48\\" Electric fan 1200mm sweep |
| 65 | EL-IN-EF-AC) Charges for assembling and fixing of ceiling fan |
| 66 | EL-IN-EF-EFSupplying and fixing of following dia sweep AC exhaust fan of approved ISI QualityEL-IN-EF-EF300b) 300 mm dia sweep AC exhaust fan |
| 67 | DM- R-EF-EPL/CF&TLRemoving the damaged electrical pipe lines without affecting the adjacent structure |
| 68 | DM-R-EF-LP&SWRemoving the damaged light point with ceiling rose, without ceiling rose, 5Amps switch board itself and convenient place |
| 69 | EL-IN-EF-MOD-SWITCHSupplying and fixing of 5 Amp flush type switch and 5 Amp/15amp 3 pin flush type wall socket for light & fan |
| 70 | DW-DMB-RCC -MMDismantling the existing damaged RCC with out affecting the adjacent structures |
| 71 | CN-SS-RCC-P/R TRTPatch Repair Treatment : Providing and applying of Renderoc SP 40, shrinkage controlled |
| 72 | CN-SS-RCC-CR FIIL Attending the Crack by cutting the cracks for 3 to 5mm width and applying crack filler and finishing the surface with some painting etc., |
| 73 | MW-MS-GR-ANTAnticorrosive treatment for window grills |
| 74 | PA-Ex-OIP-2C EPPainting the old iron work with two coat of approved Ist class synthetic enamel paint including thorough scrapping |
| 75 | LF-PL-10P-G+4Design, Supply, Delivery, Installation,Testing, and Commissioning of Passenger Lift (Brand: Johnson / Kone / OTIS or equivalent) of capacity 10 Persons with 5 Floors / 5 Stops / STAINLESS STEEL (1.5 mm) Car Cabin Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysOct 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender